Loading...
HomeMy WebLinkAbout017-260-163m 011-410-163 $ER1 WEIBEL, Garey 141 Alm Bluffs Dr., Chico New Single Family 011-410-163 PERMI' WEIBEL 141 Alm Bluff Dr., Chic Cont; Robert Hill New Pri Swimming Pool (217- 2W-/63 COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION " 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. APPLICATION AND PERMIT 97-0118 ASSESSOR PARCEL NUMBER 011-41-0-163 ZONING BUILDING PERMIT OWNER GARY WEIBEL TELEPHONE SQ. FT. OCC. BUILDING VALUATION 1216 6,080 OWNER'S MAIUNG ADDRESS 141 ALM BLUFFS DRIVE CHICO CONTRACTOR'S NAME JAMES SERRAO CONST TELEPHONE CONTRACTORS MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNI(NOWN Total Valuation $ Filing Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 90.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDINGADDRESS PERMITFEE $ 110.00 PLUMBINGPERMIT Filing Fee 20.00 Each Trap 7.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP Solar or heat pump water heater 23.00 Water piping 15.00 USEOFSTRUCTURE SF ❑X Duplex ❑ Mobilehome ❑ Other SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other CY Describe Work: UNDERFLOOR AREA CONV TO STG — Mobile Home I S I G W 1 920.00 PERMITTEE $ Contractor ELECTRICAL PERMIT Filinq Fee 20:00 Main Service / OOOV OR LESS 200A OR LESS ) 23.00 Main Service ( 200A TO I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. 1 R y 2 License Class %3 Lic. No. Lv CP OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR ADDNS. ( a ACC. BLDS. ) SO. 3.52 FT. NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 POER APPARATUS LIGHTS (a SINWGLE OUTLET CIR. ) 15.00 Ex. Occup. (OUTLET OR FIXTURES ) sA� s2a @ 1.00 o Ex. Occup. ( OUTIETs RES D.)EA) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ Contractor WORKERS' COMPENSATION DECLARATION I h-dreebby affirm under penalty of perjury one of the following declarations: A►/ I have and will maintain a certificate of consent to self -insure for workers' Y compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0-1'have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 9 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forth ith comply with tho provisions. X Date H'L 3 Signa re of Applicant - Owner 06ftntractor ❑ Agent An SHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee Is OCC i1 CONST. TYPE VNTOTAL FEE $ 145.00 HAZ. D. FEES IMP FLOOD CDF PARCEL X PD HD ISSUE This permit is hereby issued under the of the Butte County Code and/or indicated above for which fees have By PERMITEXPIRESON I applicable provisions Resolutions to do work been paid. Date (Date) Receipt No. 209554 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT ��� �o�- a�fe fo �j�' �f,��t i� d�, s f;�,e �nr�r �o�d 5���lsf'or� rE� � �� _ ca,��s�r��e �l� o�� �o� �as�t�8' Mon. Tues. Wedn. Thurs. Fri. Sat. Sun. Employee Employee Number Position December 30 Decembe 31 January 1 January 2 January 3 January 4 January 5 Vieira, Michael C. 32103 Manager 9.25 4.50 9.00 8.30 7.50 Rutherford, Scott 25153 Supervisor, BI 3.00 6.00 5.50 Kellogg, George 33294 PI Ck Engr. 4.50 7.25 6.50 Taylor, Rod 27027 Suprvsg. BI 7.00 7.00 7.00 8.00 Barron, Bill 27232 Suprvsg. BI Aznoe, Gary 29359 BI -II 2.00 0.50 League, Bart 29986 BI -II Gibbons, Glenn 27838 BI -II 12.00 6.00 12.00 6.00 Nelson, Carl 29358 BI -II 12.00 6.00 Wasney, Dave 29256 BI -II Sexton, Linda 27766 BPCII Whitney, Martha 33401 BPCII Brown, Gary 33295 CEO Johnson, Scot 29669 CEO 21.00 18.50 18.00 -12.00 Larsen, Brian 31281 Admin Analy 3.00 Brandel, Anne 23854 SBISS Sperling, Donna 9953 OA -III Mefford, Alice 24981 Pmt App Lawson, Jud 31295 OA -III Total 21.00 18.50 1 18.00 1 21.00 41.30 1 25.00 Mon. Tues. Wedn. Thurs. Fri. Sat. Sun. Employee Employee Number Position 1 January 6 January 7 January 8 January 9 January 10 January 11 January 12 Vieira, Michael C. 32103 Manager 9.25 4.50 Rutherford, Scott 25153 Supervisor, BI 3.00 Kellogg, George 33294 PI Ck Engr. 4.50 7.25 6.50 Taylor, Rod 27027 Suprvsg. BI 7.00 7.00 7.00 8.00 Barron, Bill 27232 Suprvsg. BI Aznoe, Gary 29359 BI -II 2.00 0.50 League, Bart 29986 BI -II Gibbons, Glenn 27838 BI -II 12.00 6.00 Nelson, Carl 29358 BI -II �oE Ar(:::y 7_,, COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538- 541 _ PERMIT NO. APPLICATION AND PERMIT - - - - -- ASSESSOR PARCEL NUMBER %D i (TELEPHONE ZONING BUILDING PERMIT OWNER SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS CONTRACTOR'S NAME TELEPHONE CONTRACTORS MAILING ADDRESS Fireplace CONSTRUCTION LENDER U404OWN Total Valuation i$ Fling Fee $ 20.00 LENDER'S MAIUNG ADDRESS Permit Fee $26,00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS PERMITFEE $//0,()6 PLUMBINGPERMIT Filing Fee 20.00 Each Trap .00 LOT NO. SUBDNISIONSNAME PARCEL MAP Solar or heat pump water heater 23.00 USE OF STRUCTURE SF X Duplex ❑ Mobilehome O Other - SPECIFY Water piping — 15.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outofs 15.00 Building sewer 15.00 TYPE OF WORK New O Addition O Remodel O Utilities O Installation ❑ Other ❑ Describe Work: .30X I + 2 (p K � l + BOX 15- Mobile Home ISIXW @20.00 PERMITFEE $ Contractor ELECTRICAL PERMIT Filinq Fee 20.00 Main ServiceOOOV OR LESS ( zooA OR LESS ) 23.00 Main Service ( zooA TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: O 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NEW CONST. DWELLING OCCURS oR AooNs. ( s ACC. BLos. ) O. 3.5¢ FT. NEW CONST. MULTI.OUTLET NON.RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS 8 SINGLE OUTLET CIR. J E Occup. (OUTLET OR FIXTURES ) . zo p I.00 SAL Q .SO Ex. Occup. ( OFIXEEDTs tR sE .OR 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ ,O0 Contractor MECHANICAL PERMIT Filing 9 Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor O Agent An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ ccT. TYPE V ( TOT L FEE $ HAz. o. FEES IM FLOOD CDF PAR EL PD HD ISSUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMITEXPIRESON the applicable provisions Resolutions to do work been paid. Date (Date) Receipt No. J 5 1 WHITE-D.O.S.-B. D. ANARY-ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT 011-41=ni E a 0 WEIBEL 141 AlSF:;,(-under) - '' l 4,,,,e - u .b'/ . Lj Id a����� . 0 A f------------ e-trc-l- Aqcr" &-R—c tAJ 6-T � o r) e RESIDENTIAL 95-2565 011-410-163 WEIBEL, GAREY 141 ALM BLUFF DR, CHICO .NEW S F OFFICE COPY Address GAS Ly Date IC' j`_ / W Date JOB FINALED (Dat / z Signature V=OK O = Not OK =Applicable Nott Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements - Setbacks - Easements 2. Footings; Soils-Size-Dep"pacing-Connectors-Steel 2. Soils,; Special MH Support Sketch 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer; Location-Test-Fall-C/O-Concrete 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 4. Water, Location-Test-Easement Needed (Sketch) 5. Alum. Awn.; Columns-Connec0ons-Splice-Decal-Enclosures 5. Electricity; Location-Clearances-Gmd-/ /Amp-Concrete 6. Carports; Windows -Doors 6. Gas; Location-Test-Wrap; / /"L'ft. / /Nat. or/ PL"ft./ /LPG 7. Electric 7. Well Clearance & Disconnect 8. Frmg.; Sils-AnchorsStuds-Rftrs-Trusses 8. Utility Clearance 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing Date Card B-1 Date Card B-1 Date Cana B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements- Setbacks Easements Card B-1 Date Card B-1 2. Footings; Size-.Spacing-Mamage Line POOLS (Plans) OK except #'s 3. Gas; MHTest-DemandVaKeConnector 1. Setbacks -Easements 4. Electricity; MH Test-Crossovers-Breakers-Clearances 2. Soils; Compaction -Structure Stability 5. Drain; MH Test-Fall-flex Connector 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 6. Water; MH Test-Regulator-Connector 4. Elec.; Receptacles and Lighting, Distance-GFI 7. Water and Sewer Connected-C/O to Grade-HD Approval 5. Elec.; Pool Lighting; 15 Volts-GFI 8. Gas and Electricity Tagged 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 9. Tie Downs-Type-Installation Cert. 7. Elec.; Bonding; Metal w/6 -Circulating Equip. -Heater 10. Exits; Insp.-Sketch 8. Elec.; Grounding; Equip. w/3 Circulating Equip. -Pool Lghtg. • Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 11. Cert of Occupancy 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils-Size-Dep"pacing-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns-Connec0ons-Splice-Decal-Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/6 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/3 Circulating Equip. -Pool Lghtg. • Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK O=Not OK = Not Applicable Not Ready RESIDENTIAL = Date UNP EELOOR (Plans) OK except If's Zoning -Setbacks -Easements -Flood- ope 2. Ftg,-Main; Soils-Elec. Grnd.-/ " Ftg. Depth Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ft orches & Decks; Soils -Steel-/ /Ftg. Depth temwalls, Main; Steel-Blockouts-Wrapped 6. S walls, Garage; Steel - Brock outs -Wrapped Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date I Card B-1 Date Card B-1 Date �W-1 if Ij gJard B- /J Date Card B-1 Date PLU GING (Permit) OK except n's 16. er Htr.: Vent -Ac ss -Combustion Air -Baffle ter Pipe: & Anchor -Nail Protection D-- V ;Test -Fittings & Anchor -Nail Protection----------------------- -- - -- .Shower Pan; Test First Floor -Tub Access ---- -- 20.Oeub & Shower. Second Floor Tub Accesspe: Size & Anchors -- -------------------------------.............. -------- - - - -------------------------------------------- _6j - - - - -- ------- -- ---- -- ----------- -------- Date �S _6j Card B-1 Date Card B-1 ---� -- ------------- - --------------- -.. -- -- -- Date Card B-1 Date Card B-1 Date ELEC CAL (Permit) OK except a's Fixture & Transformer Clearance -Ins. Protection --------------- ---- -------------------------- ---------------- Elec. Receptacles Spacing -Lights Lights -&- at -Do -ors ------------ Siz .Boxes & No. of Conductors -Stapled - o ex Installed Close to Edge of Studs & C J. Equip. Ground made-up wrMech. Fastners-Bond Gas &Water 2 App Dance CircuIs in Kitchen & Conductor SizerGFI _ 28. Subfeed Wire Size ga. Cu or AI-A.C. Wire Size • r ga. Cu or At ----------------`--------- ------------------------ -- 29. Range Circ. r ' ga. Cu or AI -Oven Circ. , / ga. Cu or Al. 3�I ulated Neutral ❑ Yes ❑ No 3�vice-Riser Conductors & Ground -Main Disconnect uip Clearances Panels-Motors-Mech. Equip, Clothes Closet Light -Shower Light -Spa Light --- - ------ 60r - ........................ ... 9�y ok................... --------------- --- --- .. .. ....... . .... .. Date'Card 1 Date Card B-1 - -- -� 5 ......... - ...--- -- --- Date Cartl B-1 Date Card B-1 Date MECIW61CAL (Permit) OK except a's Ducts Insulation & Support ------- - -- /A ...... ; nt Fan: Exhaust above insulation Condensate Dram &Overflow. Size &Grade rnance-Vent: Access -Comb. Air -Return Air Vent -115 ouUel Attic -Access-& Platform if.Furnance in Attic Dat��'7 (/ Cartl B- Date Card B-1 ( l ---- --- . . .. . .. .. . Date Card B- Date Card B-1 Date FRA"G (Plans) OK except a's 3 % .. Proper Mater al & Anchors 9� s tuds-Nailing. Spacing & Bracing -Plates -Sound r�ngWalls. over Girders &FloorNailing Stop in Walls (rat proof) - . Fv _Stops Furred Ced ngs-Stags-Chases-Tub ------------- ..._. e -St . .. eaders & Beam -Size &Bearing (Single & Duplex) Date RAMING (Continued) HHangers-Post Caps-Anchors-Connectors ties-Purlin-roof Brac-Truss-Shthng.-Ring. - 4�Y replace Ties or Type A Flue -Fireplace Throat clearance 48. A Access; Size & Romex Protectign-Draft Stop -Ins. Baffles ------------ --Bdrm Windows or Exiting Doors -Sill Hgt. & Dimensions ---------- - - yG�rage Fire Protection Framing ......... - -5r1y�� operty Line Firewall & Openings _ /52 t. Doors -One 3 -Check Garage -3rd Story, 2 Exits - - ---- - 93 lair Width -Headroom -Rise -Run -Landing -Fire Protection t ood on Roof Overhang -Attic Vents -Raft Outriggers (y % Si g -Nailing Veneer 5 fa_ co Mesh -Drip Screed -Fd. Vents-Underflr. Access 37. Glagn g Area -Glass Protection-Skylights-Plastic g hWalls: Nailin Bolts n ion-Walls-Ceilings141, — nfiltration_Walls_Windows--J=3 ----------------------------------- ------------------------------------------------- - Date Card B-1 Date Card B-1 ------------------------------------------ Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except a's 6 -/Ext. Steps -Door & Sidelight Protection -Landings —_ ke -Smoke Detector --------------------- Furnace: Vents -Clearance -Comb. Air -Connector- - oomEx Garage: Above Floor -Ducts -Meth. Protection — edriting .e!5'._G.F.I & Bath Fixtures & Tub Access -Spa lec. & Subpanel: Breaker Sizes & Labels --------------------- ... ..__ -fairs Rl - - ----- - ------------------------- ire lace or Stove: Clearances -Hearth Elec. Outlets at -Wood -Panel: Int. & Ext. ...... .. .r_ - -- ------------------- ------------- Kit---- &Appliance; Grnd.-Air Gap -Cooking Clearance Ele�c. Outlets & Receptacles at Kit. Counter -- -- 4.2'Gara eFire Door Swing -Landing -Closer --- ------------ ----- ---- ----- A C. Duct in Garage -Damper ----------------- ---- -------------------------- Ir. Htr : Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection ...... - -- --------------- ----- lb.. Elec. & Mech. Equip. Listed for Location 7 Receptacles in Garage: (G.F.I.)-Romex Protection . _-- ion -Foam -Looked in A(Uc ❑ Yes Guar hafts & Dec -k _ Const ruction -Post Caps dn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clea a Looked under Floor ❑ Yes -- ----------------�-- ---- - -- -- u No: ollowing instl - ive ,Yes ❑ No: Walks Yes PI cars Yes ❑ No ... - ----------------------- _ Stucco .Brown -Finish C Unit: Disconnect. Electrical, Plumbing - - ------------------------------------ ents Above Roof. Plbg.-Appliance-Fireplace.-Clearance to Ope rigs __ _ _ _ Water Well: Disconnect. Electrical, Plumbing -- _- — - xter �flec. Trim: G F.I Receptacle -Underground I. on Throughout House GI rotechon -- -- ------------------------------------------- -- ----------- orr tions from Previous Inspections - --- -------------------------- dY a st-Meters Tagged: Gas -Electric . .. - - ------ ------------------------------ W 2r &Sewer Connected -C-- to Grade- -- Approval Energy Compliance Certificate -Other Certificates - --- -------- Date Card B 1 _Date CardB-1 Date` Card B -t Date - -- -Card B -t ---------- Datj/����% Card B-1 Date Card B-1 Comments fat Final E.H. USE ONLY Plot PLa Attaclml Floor Plan AmwW Smt to B.D. TO: Building Department J FROM: Environmental Health SUBJECT: Sanitation Clearance -Myw� :hL6S P( Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for bedroom mobile ome. Other Hold final for: S Final clearance O.K. for: `,�-, NO L) -M`. En ironmental Health Specialist Date R/92 CORRECTION NOTICE OWNER i 0 n A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is complete you have any questions pertaining to this matter, or need additional explanation, please con ct i%office immediately. I FIA Date l -�J S /7(p Inspector REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 - - -- 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER i 0 n A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is complete you have any questions pertaining to this matter, or need additional explanation, please con ct i%office immediately. I FIA Date l -�J S /7(p Inspector REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE c 113C L ER PERMIT NO. A routine inspec ion indicates that the following violations of Butte County Ordinances exist at the above ad ess and should be corrected. Please notify this office when correction of work is complete If you have any questions pertaining to this matter, or need additional explanation, pleas. co act this office immediately. Date / 5 Inspector REV 10/92 R r ENGINEERED WOOD SYSTEMS i A i Certifficate'd Conformance. Certificate 041227 THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural wood products identified below and marked with a collective mark of American Wood Systems (AWS) were manufactured in accordance with the specifications indicated below. . M, ANSI Standard A190.1-1992, for Structural Glued Laminated Timber Job Name WESTERN BUYERS INC. Job Location ELK GROVE, CALIFORNIA WB -23404 Customer's Order No. Date .1-25-96 Mfgr's Order No 09-03866 Signature 92o�oT- Title QUALITY CONTROL SUPERVISOR companyUOISE CASCADE CORP • Address P • -0. BOX 50 oats BOISE, IDAHO 83728 IT IS HEREBY. CERTIFIED that the structural glued laminated timber production of the above- named manufacturer which carries a collective mark of American Wood Systems (AWS) is subject _ 44.,Ao..regular audit by, American Wood Systems, such audit consisting of the inspection with reasonable frequency of the 'manufacturing process, with adequate sampling to verify the quality of glulam construction and the adequacy of glue bond. W 00D .•••,�GPHOR �v F Q = SEAL = y' O���L �s NG,�� �• . iby Thomas G. Williamson Executive Vice President AMERICAN WOOD SYSTEMS - A RELATED CORPORATION OF APA A Pi4 crr� Attachment Number 1 TO CERTIFICATE OF CONFORMANCE NO. 041227 DATED ' Job Name WESTERN BUYERS INC. Job Location ELK GROVE, CALIFORNIA WB -23404 1-25-9609-03866 Customer's Order No. Dated Mfgr's Order No. The following identifies the members and gives the basic specifications that were used on this job: Lumber Species: DOUGLAS FIR/LARCH Member Adhesive Appearance Identification Quantity Size Combination Type Grade Camber *** SEE ATTACHED ORDER ACKNOWLEDGMENT FOR EXACT SPECIFICATIONS. *** BOISE CASCADE CORPORATION Company Mill Quality 6ontrol Supervisory Date AMERICAN WOOD SYSTEMS — A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION Boise Cascade Timber. and Wood Products Group P.O. BOX 62 • BOISE, IDAHO 83707 .397 . -.O.B. FREIGHT PREPAID COPIES TO: ACKNOWLEDGMENT 'x'1/25/96 1 09-03866-00 CUSTOMER ORDER NO. ORDER DATE B723404 1/25/96 SHIP WEEK OF 1/29/96 LOAD: .LEGAL COMMON CARRIER TRUCK SPECIAL INSTRUCTIONS- ---- SPECIFICATIONS ---- *DOUGLAS FIR/LARCH *EXTERIOR GLUE *STRESS '2400-F V-8 EXCEPT COLUMNS *ARCHITECTURAL ROUGH SAWN APPEARANCE - S3S EXCEPT AS NOTED *INDIVIDUAL WRAP *ENDS AND SIDES SEALED *A.P.A./E.W.S.CERTIFIED *ONE END SQUARE ONE END WILD *CAMBER 2000' RADIUS EXCEPT AS NOTED *NO SHOP DRAWING * ****** NOTE TO MILL ***** * *SELECT WOOD FOR APPEARANCE - NO PUTTY- * *ANSI A190.1-1983 REPLACES VOLUNTARY PRODUCT STANDARD PS 56-73. SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF b Boise Cascade ACKNOWLEDGMENT Timber and Wood Products Group CUSTOMER ORDER DATE[AGE P.O. BOX 62 • BOISE, IDAHO 83707 397 1/25/96 2 09-03866-00 ERMS CUSTOMER ORDER NO. ORDER DATE 2% CD ADF 15 DAYS NET 16 DAYS ADI 02 B-23404 1/25/96 ,=.O.B. SHIP WEEK OF FREIGHT PREPAID 1/29/96 COPIES TO: SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF MILL DELV BDFT TOTAL EST. PCS MARK SIZE LENGTH PRICE PRICE / PC BDFT WGHT CUSTOM.ARCHITECTURAL BEAM 10 A 5-1/8 X 6 X-12' 48 480 869 CAMBER: ZERO \ COL NET SIZE 5-1/8 X 5-1/8, ROUGH Sk,WN S4S, #5 LAYUP 4 B 5-1/8 X 6 X 14' 56 224. 405 CAMBER: ZERO \ COL • NET SIZE, 5-1/8 X 5-1/8, ROUGH SAWN S4S, #5 LAYUP 1 C 5-1/8 X 12 X 8' 64 64 116 CAMBER: ZERO \ V-8' 1 D 5-1/8 X 18 X 11' 132 132 239 CAMBER: ZERO \ V-8 2 E 5-1/8 X.18 X 13' 156 312 565 CAMBER: ZERO \ V-8 3 F 5-1/8 X 18 X 16' 192 576 1043 CAMBER: ZERO \ V-8 0 . 4 G 5-1/8 X 18 X 17' 204 816 1477 CAMBER: ZERO \ V-8 3 H 5-1/8 X 18 X 21' 252 756 1368 CAMBER: ZERO \ V-8 2 I 5-1/8 X 18 X 23' 276 552 999 CAMBER: ZERO \ V-8 SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF Boise Cascade, ACKNOWLEDGMENT Timber and Wood Products Group CUSTOMER ORDER DATE[AGE ORDER/INVOICE NC P.O. BOX 62 • BOISE, IDAHO 83707 397 1/25,/96 3 09-03866-00 IT ERMS CUSTOMER ORDER NO. ORDER DATE 2 CD ADF 15 DAYS -NET 16 DAYS ADI 02 B-23404 1/25/96 .=.O.B. SHIP WEEK OF FREIGHT PREPAID 1/29/96 COPIES TO: MILL DELV BDFT -TOTAL EST. PCS MARK SIZE LENGTH PRICE PRICE / PC `BDFT WIGHT 2 J 5-1/8 X 18 X'30' 360 720 1303 MILL AMOUNT FREIGHT MISC CHG 840 1520 672 1216 213 386 416 753 540 977 TOTAL BOARD ESTIMATED AMOUNT PIECES FOOTAGE WEIGHT 40 7,313 13,236 SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF CAMBER: ZERO \ V-8 2 K 5-1/8 X 18 X 35' 420 CAMBER: ZERO \ V-8 2 L 5-1/8 X 18 X 28' 336 CAMBER: \ V-8 2 M 6-3/4 X 7-1/2 X 16' 107 CAMBER: ZERO \ COL NET SIZE 6-3/4 X 6-3/4, ROUGH `SAWN S4S, #5 LAYUP 1 N 6-3/4 X 18 X 26' 416 CAMBER: ZERO \ V-8 CUSTOM ARCHITECTURAL BEAM 1 0, 5-1/8 X 18 X 45' 540 CAMBER: \ V-8 MILL AMOUNT FREIGHT MISC CHG 840 1520 672 1216 213 386 416 753 540 977 TOTAL BOARD ESTIMATED AMOUNT PIECES FOOTAGE WEIGHT 40 7,313 13,236 SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF A PA E 1r, 4, r, "Ne Attachment Number 2 TO CERTIFICATE OF CONFORMANCE NO. 041227 DATED . Job Name WESTERN BUYERS INC. Job Location ELK GROVE, CALIFORNIA WB -23404 1-25-96 09-03866 Customer's Order No. Dated Mfgr's Order No. The following gives the additional specifications that were used in the manufacture of the members on this job: 1. Lumber Species DOUGLAS FIR/LARCH Grading rules WCLIB #16 2. Moisture Content 3. End Joint 4. Adhesive 5. Gluing Paragraph 154 th,:•u 154C Grades 24T 22T 20T L1 1-21) L2 L3 Slope of grain 1:16 1:14 1:12 1:08 Range 9-12% Variation per member 5% HORIZONTAL FINGER JOINT Conforms to ASTM 2559-82 Type PENACOLITE R-300 Pressure 100 psi minimum Glue spread 60-61 lbs. 6. Fabrication Conforms to specification of BOISE CASCADE CORPORATION Company specifications. Batch No. CB -270-1 Pressure Period 12 fours minimum Ai'dSI Standard A190.1-1983 Mill Quality - Control Supervisor Z Z3 -- `/ Date AMERICAN WOOD SYSTEMS — A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION t ♦x .. `r iYYIT ] . 111111:40, Eel 104 14:11V M1191MOT61 . APA Certificate of Conformance Certificate 041267 THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural wood products identified below and marked with a collective mark of American Wood Systems (AWS) were manufactured in accordance with the specifications indicated below. XZf4ANSI Standard A190.1-1992, for Structural Glued Laminated Timber 101 Job Name WESTERN BUYERS INC. Job Location ELK GROVE, CALIFORNIA WB -234162-09-96 09-03905 Customer's Order No. Date Mfgr's Order No DOUGLAS FIRAARCH, EXTERIOR GLUE, 240OF—VB, ARCHITECTURAL APPEARANCE, (ROUGH SAWN), INDIVIDUAL. WRAP, ENDS & SIDES SEALED, ZERO CAMBER. signature 9 d`- C�a Title QUALITY CONTROL SUPERVISOR CompanyBOISE CASCADE CORP. Address P. 0. BOX 50 Date 13 ` q1, BOISE, IDAHO 63726 IT IS HEREBY CERTIFIED that the structural' glued laminated timber production of the above- named'manufacfurer which carries a collective mark of American Wood Systems (AWS) is subject L to regular audit by American, Wood Systems, such audit consisting of the inspection with reasonable frequency of the mnufacturing process, with adequate sampling to verify the quality of glulam construction and the adequacy of glue bond. �00NW004e N p�4� Q t ! � SEAL g yby . Thomas G. Williamson Executive Vice President ING�O?,•, AMERICAN WOOD SYSTEMS - A RELATED CORPORATION OF APA A P.4 ��"w Attachment Number 1 TO CERTIFICATE OF CONFORMANCE NO., 041267 DATED Job Name Job Location Customer's Order No. WESTERN BUYERS INC. WB -23416 Dated 2-09-96 ELK GROVE, CALIFORNIA Mfgr's Order No. 09-03905 The following identifies the members and gives the basic specifications that were used on this job: Lumber Species: DOUGLAS FIR/! ARCH Member Adhesive Appearance Identification - Quantity Size Combination Type Grade • Camber *** SEE ATTACHED ORDER ACKNOWLEDGMENT FOR EXACT SPECIFICATIONS. *** BOISE CASCADE CORPORATION Company —AlZ //;" Mill Quality ontrol Supervisor �- 13-2& Date AMERICAN WOOD SYSTEMS — A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION Boise Cascade Timber and Wood Products Group P.O.'BOX 62 • BOISE, IDAHO .83707 ACKNOWLEDGMENT CUSTOMER ORDER DATE AGE ORD OICE NE 396 2/09/96 1 09-03905-00 CUSTOMER ORDER NO. ORDER DATE .O.B. SHIP WEEK OF FREIGHT PREPAID 2/26/96 COPIES TO: G CRANDLEMIRE LOAD: LEGAL COMMON CARRIER TRUCK SPECIAL INSTRUCTIONS.. * *---- SPECIFICATIONS ---= * *DOUGLAS FIR/LARCH *EXTERIOR GLUE *STRESS 2400-F•V-8 ' *ARCHITECTURAL APPEARANCE - ROUGH SAWN 3 SIDES *INDIVIDUAL WRAP. *ENDS & SIDES SEALED *A'.P.A./E.W.S.CERTIFIED *ONE END SQUARE ONE END WILD *ZERO CAMBER *NO SHOP DRAWING * * *ANSI A190.1-1983 REPLACES VOLUNTARY PRODUCT STANDARD PS 56-73. * *SELECT LAMS FOR APPEARANCE, NO.PUTTY, ******* SUBJECT TO ALL TERMS AND CONDITIONS ON REVERSE SIDE HEREOF r P i � � � ' F +;� �� APAKrV%7' Attachment Number 2 TO CERTIFICATE OF CONFORMANCE NO. 041267 DATED Job Name WESTERN BUYERS INC. Job Location ELK GROVE, CALIFORNIA WB -23416 2-09-96 09-03905 Customer's Order No. Dated Mfgr's Order No. The following gives the additional specifications that were used in the manufacture of the members on this job: 1. Lumber Species DOUGLAS FIR/LARCH Grading rules WCLIB #16 2. Moisture Content 3. End Joint Paragraph 154 thea 154C Grades 24T 22T 20T L1 L2D L2 L3 Slope of grain 1:16 1:14 1:12 1:08 Range - 8-12% _ Variation per member 5 HORIZOI4TAL FINGER JOINT 4. Adhesive Conforms to' ASTM 2559-82 specifications. Type PENACOLITE R-300 Batch No. CB -270-1 5. Gluing Pressure 100 psi minimum Glue spread 62 1 bs . 6.1 Fabrication Conforms to specification of BOISE CASCADE CORPORATION Company Pressure Period 12 hours minimum ANSI Standard A190.1-1983 Mill Quality Control Supervisor --/3-�� Date AMERICAN WOOD SYSTEMS - A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION APPLIED ':"Y ANNE TESTING '::°9 G:,:,.:CONSULTANTS Report of Field or Shop Welding Inspection REPORT TO: Jim Serrao ATC FILE NO: 96559 1051 Four Acres Court OSA FILE NO: Chico, CA 95926 APPLICATION NO: PROJECT: Weibel Residence - Lot 15, Alm Bluff Drive, Chico WELDING PERFORMED AT: Jobsite 02-08-96 Materials 5050 Engineering Cohasset Road Testing and Chico, CA Inspection 95926 Crane (916) Certification 891-6625 WELDER'S NAME SOCIAL SECURITY NO. CERTIFIED BY DATE William E. Jones 555-78-3806 Peabody Machine 06-15-84 David R. Martin 573-84-4939 Applied Testing 09-28-92 PLANS, SPECIFICATIONS OR SHOP DRAWINGS BY: Lenn Goldman and Associates Shop Drawings by Tink, Inc. DATED: August 1995 Miller Big 40 E7018, 1/8" dia. EQUIPMENT USED: Miller Legend ELECTRODE: E7018, 1/8" dia. PROCEDURE USED: Flat single -bevel groove weld with backing. SMAW WORK IN PROGRESS: Beam -to -column connections at Columns MK1A and MK2A per details 1,2 and 3 on Sheet 10 of the approved project drawings. REVISIONS OR CLARIFICATIONS None. ITEMS COMPLETED THIS DATE: C.P. beam -to -column connections at Cols. IA and 2A completed this date. Total of 4 C.P. connections completed today. REMARKS: All welds good quality' and in accord with approved plans and AW `- Z1 CONTINUED O WELDING IN PECTOR HEIDELBERG GRAPHICS F► I INN APPLIED SOCIAL SECURITY NO. Materials Engineering 5050 Cohasset Road TESTING Testing and Chico, CA 06-15-84 Inspection 95926 CONSULTANTS 09-28-92 Crane (916) PLANS, SPECIFICATIONS OR SHOP DRAWINGS BY: Lenn Goldman and Associates Certification 891-6625 of Field or S REPORT TO: Jim Serrao 1051 Four Acres Court Welding Inspectior ATC FILE NO: 96559 OSA FILE NO: Chico, CA 95926 APPLICATION NO: PROJECT: Weibel Residence - Lot 15, Alm Bluff Drive, Chico WELDING PERFORMED AT: Jobsite 02-07-96 WELDER'S NAME SOCIAL SECURITY NO. CERTIFIED BY DATE William E. Jones 555-78-3806 Peabody Machine 06-15-84 David R. Martin 573-84-4939 Applied Testing 09-28-92 PLANS, SPECIFICATIONS OR SHOP DRAWINGS BY: Lenn Goldman and Associates Shop Drawings by Tink, Inc. DATED: August 1995 Miller Big 40 EQUIPMENT USED: Miller Legend E7018, 1/8" dia. ELECTRODE: E7018, 1/8" dia. PROCEDURE USED: Flat single -bevel groove weld with backing. SMAW WORK IN PROGRESS: Beam -to -column connections' at Columns MK1A, MK1B, MK2A and MK2B per Details 1,2 and 3 on Sheet 10 of the approved project drawings. Total 16 connections. REVISIONS OR CLARIFICATIONS None. ITEMS COMPLETED THIS DATE: C.P. beam -to -column connections at Cols. 1B and 2B completed this date. C.P. connections at Cols 1A and 2A continue in progress. Total of 12 C.P. connections completed today. REMARKS: All welds good quality and in accord with approved plans and AWS DFfa.�,,, CONTINUED ❑ WELDING INSP CTOR Lao HEIDELBERG GRAPHICS of Field or Shop Welding I Kg Materials 5050 Engineering Cohasset Road Testing and ' Chico, CA Inspection 95926 Crane (91 6) Certification 891-6625 REPORT TO: Jim Serrao ATC FILE NO: 96559 1051 Four Acres Court OSA FILE NO: Chico, CA 95926 APPLICATION NO: PROJECT: Weibel Residence - Lot 15, Alm Bluff Drive, Chico WELDING PERFORMED AT: Jobsite 02-08-96 WELDER'S NAME SOCIAL SECURITY NO. CERTIFIED BY DATE William E. Jones 555-78-3806 Peabody Machine 06-15-84 David R. Martin 573-84-4939 Applied Testing 09-28-92 PLANS, SPECIFICATIONS OR SHOP DRAWINGS BY: Lenn Goldman and Associates Shop Drawings by Tink, Inc. DATED: August 1995 Miller Big 40 EQUIPMENT USED: Miller Legend E7018, 1/8" dia. ELECTRODE: E7018, 1/8" dia. PROCEDURE USED: Flat, Vert. and O.H. fillet and FBG welds. SMAW. WORKINPROGRESS: Fillet and flare groove welded TS and WF beam connections as shown in Details 5 (revised), 14 and 15 on Sheet 10 of the approved drawings. REVISIONS OR CLARIFICATIONS Detail 5 on Sheet 10 revised by the Engineer to provide moment connections across Columns MK3A and MK3B.' See attached drawing. ITEMS COMPLETED THIS DATE: All work described above completed today. REMARKS: All welds good quality and in accord with approved plans and AWS /O-T� CONTINUED ❑ 14:14;:f 10196 WELDING I SPECTO �`��' SAO 10 HENEIaERG GRAPHICS _ y p l r TYP. I/4 III III PL5/8" x O'.— 4" x I'— 10" TYP. F—v TOP BOTTOM PTY1/4 TYP. I I . FEssloo," I I 1/5"-(P WEEP HOLE TYP co .rqj� civic ,Q T5, 5EE PLAN OF CAVE ' TS MOMENT GONNEr., T 1 Oil REVISED 1.1/2" = 1'_0" ■■MEN^mmu■■ ■ENEM ■■!E■ NE■l 1■NE ► 1 /00 AAL/b-1 Materials 5050 Engineering Cohasset Road Testing and Chico, CA Inspection 95926 Crane (916) Certification 891-6625 HEIDELBERG GRAPHICS DEC -211995 09:51 FROM ?J 2��5 December 21, 1995 TO = ' 8956512 P.01 NGINEERING it Er�pineer5 • pIann'ers • Surveyors post 11`" bran diaxtta�15�'��>r Department of Development Servii s peg�� BUILDING DEPARTMENT S 1469 Humboldt Road pax «Is Chico, CA. 98928 - .Atte; Dave Wasney Subject: Weibel Residence A_; Dear Mr. Wasey. ti The wntractor has requested that a of the two #4 bas in the top of the foundation be- Wet set `� lv pryvidr, rows to vibrate. Wei is tereby approve this change 'The #4 'bar will be wet set sareeded. ' immediately after the concrete co, vibrated and Very Truly Yours, TE COUNTY DEPARTMENT. NQRTHSTAR ENGiNEMUNG A O V E D Mjchael McEnespy ,IMR sloe 12 - 2.1 EXP. 2 r 7671 Date It a I post -it! Fax N016___ From r 20 NCLARAT6­601IUE f CHICO, CALIFOFiMA 95926 916-P� 3-1600 - j �rrV.oma�m/I�aaq�'0®►�lAr � .- s... Z r OWN ER : ,( REC ' D BY LIP DATE: 4] AP# Q l f (U, �% 3 PERMIT NUMBER:' Q5 -256S TIME: 0-6 _RESIDENTIAL COMMERCIAL Cl Z(o (,, 000a00000000000000000000000000000000000000000000a0000000000000000000000000000000000000000o0000C FROM DATA SHEET REQUIRED BEFORE PERMIT ISSUANCE REQUESTED BY PLAN CHECKER ENGINEERING OTHER/COMMENT: a 000000 a 000000000000000000000000000000a0000 OOa 00000000 a Oa000000000 000000000000000000 a0 a a OOOOOOa REQUESTED BY CORRECTION NOTICE _YES NO ITEM: LOCATION IN BUILDING WHERE CHANGE OCCURS:- �000000000000000000000000000000000000000000000000000000000000000000 000 000000 0000o0ooeeeeee.,�.- MA MAIL TO CALL #: WHEN APPROVED PROCESS AS FOLLOWS FOR PICKUP AT THE DELIVER WITH NEXT INSPECTION \ Ica 0000000000000aa000000000CIO Go* 0000000000000000000alga 000 REVISED PC FEES PAID: RECEIPT# OFF! 06-000000000000000000oo0oo00o00000000000 $23.00 $46.00 NOT REQ INSULATION CERTIFICATE JIM SERRAO k ALM BLUFFS DRIVE CHICO NUMBER AND STREET CITY BUTTE COUNTY DESCRIPTION OF INSULATION 1. ROOF MATERIAL THICKNESS (INCHES) 2. CEILING BATT OR BLANKET TYPE BATTS THICKNESS (INCHES) 12 10 LOOSE FILL TYPE SUBDIVISION CONTRACTOR'S MIN INSTALLED WEIGHT/FT2 LB LOT NUMBER BRAND NAME THERMAL RESISTANCE (R -VALUE) BRAND NAME CERTAINTEED THERMAL RESISTANCE (R -VALUE) 38 BRAND NAME 38 HIGH DENSIT`. MINIMUM THICKNESS (INCHES) MANUFACTURER'S INSTALLED WEIGHT PER SQUARE FOOT TO ACHIEVE THERMAL RESISTANCE 3. EXTERIOR,WALL FRAME TYPE WOOD MATERIAL BATTS THICKNESS (INCHES) EXTERIOR FOAM SHEATHING MATERIAL INSUL-SAFE III THICKNESS (INCHES) 6 4. RAISED FLOOR MATERIAL THICKNESS (INCHES) 5. SLAB FLOOR MATERIAL BATTS- THICKNESS (INCHES) 6j PERIMETER INSULATION DEPTH (INCHES) 6. FOUNDATION WALL MATERIAL BRAND NAME CERTAINTEED THERMAL RESISTANCE (R -VALUE) BRAND NAME CERTAINTEED THERMAL RESISTANCE (R -VALUE) 19 BRAND NAME THERMAL RESISTANCE (R -VALUE) BRAND NAME CERTAINTEED THERMAL RESISTANCE (R -VALUE) 19 BRAND NAME THICKNESS (INCHES) THERMAL RESISTANCE (R -VALUE) DECLARATION I HEREBY CERTIFY THAT THE ABOVE INSULATION WAS INSTALLED IN THE BUILDING AT THE ABOVE LOCATION IN CONFORMANCE WITH THE CURRENT ENERGY EFFICIENCY STANDARDS FOR RESIDENTIAL BUILDINGS (TITLE 24, PART 6, CALIFORNIA CODE OF REGULATIONS) AS INDICATED ON THE CERTIFICATE OF COMPLIANCE, WHERE APPLICABLE. JUNE 4, 1996 DATE 2, 3, 4 ITEM #`S DAN HANSEN BRANCH MANAGER COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - ,Oroville, California 95965 - Telephone (916) 538-7541 -- _ PERRIIT NO. APPLICATION AND PERMIT f�' ��' , ASSESSORPARCELNUMBEA 011-410-163 SR3 ZONING BUILDING PERMIT OWNER GARY WEIBEL 8EPHONE 00 SO. FT. OCC. BUILDING VALUAq N OWNERS MAIUNG ADDRESS PO BOX 660 CHICO, 95927-066011681 R 198,774 359 0 2,464 CONTRACTOR'S NAME UNi�PIOGaN TELEPHONE 700 M 12,600 973 (1, 129623 CONTRACTORS MAIUNG ADDRESS Fireplace M 3,000 CONSTRUCTION LENDER NONE UNIWOWN Total Valuation $ 999, 461 LENDER'S MAIUNG ADDRESS Filing Fee $ 20,00 Permit Fee $ .80 ARCHITECT OR ENGINEER NONE LICENSE NO. Plan Checking Fee $ 711-43 Energy Plan Checking Fee $ 23.0 ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDINGADDRESS 141 ALM BLUFFS DR PERMITFEE $ 848.9 CHICO PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP Solar Or heat pump water heater 23.00 USEOFSTRUCTURE SF ❑X Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 15.0 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New EX Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 2 BR. Mobile Home S G W @20.00 PERMITFEE g Contractor ELECTRICAL PERMIT Filina Fee 20:00 Main Service ( E00v OR LESS ) 200A OR LESS 23.00 23.00 Main Service ( 200A TO I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class I No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NEW CONST. DWELLING OCCUP. OR ( 8 ACC. BLDS. ) SO. 4 3.SQ FT.193. CNS. NEW CONST.LTI.OUTLET NOWRESID. ( BRANCH CIRCUITS ) 97.50 ( 8 POWER APPARATUS ) SINGLE OUTLET CIR. Ex. Occup. (OUTLET OR FIXTURES ) 20 Q +.00 BAL SO Ex. Occup. OUTLETS (RES16°EA ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 196.34 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating 25.00 Cooling 25.00 Hood 6.50 Ventilation PERMITFEE $0.00 Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date /0 "� Signature of Ap icant - KOwner ❑ tontractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee Is 46.00 occ CONST. TYPE VNI TOTAL FEE $ 2 375.2 HA2. D. F I FLO cD p HT E This permit is hereby issued under the of the Butte County Code and/or indicated above for which fees have By PERMITEXPIRESON applicable provisions Resolutions to do work been paid. Date 1 (Date) Receipt No. 186040 - 814.43// /yD20i- L5i60, 99 WHITE-D.D.S.-B.D. CANARY -ASSESSOR P NK-INSPE TOR GOLDENROD -APPLICANT I 7 COUNtYO- BUTTE"D'`D_ E� PARTM.E.N=TOFDEVELOPMENTSERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE,&LIFORNIA95965 -TELEPHONE (916) 538-7541 PERMIT APPLICATIONZATA SHEET OWNER Cr" k, e A. P. No. Proposed Building UseBuilding Inspector7Date l0 f/�/r At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. All items have been submitted. ........................ ..................... 2. Plot plans, 3/4 sets, signed by preparer of plans. .:. , ....^.....:............ . 3. Complete plans, 3/4 sets, signed by preparer of plans. s 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans. ............... 5. Hazardous Material Form . ............................................ 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... 9. Mobilehome data and iia ufacturer's installation instructions, 2 sets. ........... AVi0. Fees of $ -?S ............................. I pact fees as shown on attached schedule. ... California Department of Forestry plan approval/ ees 13. Flood elevation letter (100 year flood) by California ngineer. ............ . 1���<p,4O"Sanitation and plot plan approval &Lilo Health Department . ............ 15. City of Chico plumbing permit . ......................................... Plot plan and business license approval fr m City of Biggs/Gridl y. . ..... ; .. . 17. Planning approval for (A) Use: J (B) Parkin : 18. Contact Land Development about (A) Improvements (B) i ��'Driveway permit (construction approval required prior to occupancy). . X20. Pre -inspection for 1,4,spection req° t p required. . . to Building Inspector (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... . 23. er-Builder Verification (Given to owner Mail to owner ........... . . Recorded copy of Agricultural Acknowledgement Statement . .......... ......: /d 25. Letter of signature authorization . ..................................... . 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ...................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed J and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... 32. Plan check list. ................................................. . 33. �4: O� 34. When bu issue the per it, process as follows: Mail to owner. Mail to contractor. Telephone - and hold for pickup at rQ v ' Q` office. Deliver with inspector. 7 Other Parcel Creation Acreage Applicant Date of Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date - Copy of plans sent Health Dept. Fire Dept. Other Date By The'following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: 4fe— So F76, G'ay. j --A) Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mailountgrby _ Date Plans checked by Date Plans approved by �G Date--2jZ� Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works �1 f O: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance E.H. USE!anY Plot Plan AthcW Floor Plan Att.c6ed Seat to H.D. I / AL ro-J AAh 1 &,qs a L,(l- 10 Owner Location APS Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for o3 bedroom .tee home. Other Hold Final clearance O. K. NOTE: L <—, /Io Environmental Health §peciahst' Date Qro1) 1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. '-- -'' APPLICATION AND PERMIT ASSESSOR PARCELNU 611r-61.16-1,413 -OWNER � BUILDING PERMIT ag,TELEPHONE CC. BUILDING VALUATION ow Aoo CONrRACTOR'9 NAME -/yam` L,CJ TELEPHONE I&, CONTRACTORS MA41N0 AD(R, 3 o o CONSTRu Ewm UNKNOWN LENDER'S MAILING ADDRESS e[ARCHITECT Total Valuation $ Fling Fee $ 20.00 Permit Fee S C Q ARCHITECT q ENGINEER IQ ne LICENSE NO. Plan Checking Fee $ 3 Energy Plan Checking Fee S. 2 0O OR ENGINEERS MARINO ADDRESS Penalty $ BURRING ADDRESS / ' PERMITFEE S g C PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 IDT No: SUBDIVISION'S NAME PARCEL MAP Solar or heat pump water heater 23,00 Water piping 15.00 S O USEOFSTRUCTURE SF'4 Duplex ❑ Mobilehome ❑ Other SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 b0 Building sewer 15.00 p Q TYPE OF WORK New k Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: SCJ Mobile Home IS I GI WL_ @20.00 PERMITFEE Contractor ELECTRICAL PERMIT Filing Fee 20:00 Main Service 000V OR LESS ( 200A OR LESS ) 23.00 Main Servicff�*o-roomc—) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date /'``'-inature of Applicant - ❑ Owner ❑ Contractor ❑ gent -permit is required for excavatioyTs pv rC ne�p n demolition or construction Tes over 3 stories in height. Jfl D — 9 ) CANARY -ASSESSOR PINK-INSPdEgrTOR GOLDENROD -APPLICANT I NEW CONST. DWELLING OCCUR SD. DR AOON ( a ACC. BLEs. ) 3.5� rT. 5 :331 NEW CONST. MULTI.OUTLEi S NON-RESID. ( BRANCH CIRCUITS ) @7.50 APPARATUS ) ( POa SINGLE OUTLET 010. Ex. Occup. ( OUTLET OR FIXTURES) 20 O 1.00 BAL .SO Ex. Occup. FIXED A PLNS. OR 5.00 Temporary S^--'-^ 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ Contractor MECHANICALPERMIT Flin Fee 20.00 FilingFee Heating Cooling OC./ Hood 6.50 Ventilation PERMITFEE $ Q 'v Contractor Mobile Home Installation Fee S Energy Inspection Fee $ L' G CONST TOTAL FEES Z. 1 O. FEES IMP D C SpJ�pjISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMITEXPIRESON (Data) • • ' COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 OWNER 0 PROPOSED BUILDING USE J4Z&w S �' 0 SCHOOL DISTRICT FEES (paid at District Office) A.P. # dZ/ = /l—1 u DATE z REC. # DATE REC .HERIFF FEES (paid at Building Division) Residential...... x =$3, Q 006r7 �Z � unit amt. Commercial (sq. ft.) . x = $ 3. URBAN AREA FEES (paid at Building Division) Residential (per unit). x =$ #units amt. Commercial (sq.ft.).. x =$ . sq. ft. amt. U RECREATION DISTRICT FEES (paid at District Office) C� 5. THERMALITO DRAINAGE DISTRICT FEES $400.00 (paid at Building Division) 6. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 7. WATER TENDER FEES (BATTALION # ) $200.00 (paid at Building Division) 8. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 9. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. L,,.a d DATE APPLICANT 1y�- /x;551. •°R! t W. 4'.. i..�1. +F BUTTS COUNTY PARRS DEVELOPMENT FEE CERTIFICATION FORM CHICO AREA RECREATION AND PARK DISTRICT Assessor Parcel Number(s) e -/% y _ / : Property Owner ( -%'„ � e %J (A i 1_, Project Location/Address � L�% / AA o CZgC;g �r Subdivision Lot Number(s) / Residential Development: (check one) �ew Development _Alteration/Addition Mobilehome(s) _Non -Residential to Residential Total Number of Dwelling Units Comment: Building Department Representative D e Chico Area Recreation /and Park District(CARD) certifies that (Applicant-tJame) (Phone Number) zV �� D (Street Address) City (State Zip .Code) has complied with the requirements of Butte Co. Resolution No. 90-140 by 00 payment for dwelling units @ $1,189 for total payment of $�,,. r. CARD Repr7entative Date PAID BY CHECK NO. REMARKS: a BANK NO. t/ -2. 12 PAID BY CASH RECEIPT NO. LFlo Distribution: White --Applicant Pink --CARD park.fee (form revised 11/90) Yellow --Butte Co. Building Dept. Goldenrod --City of Chico Building'Dept. 10/12/95 3t15PM GG1A#4166 DIECK $1189.00 .r -� 'ti.t. r - .r �� ' . •�:,,,'�`7..]'�r��i.�,. .. ., rrN�;y,�. t*.ray';`,. .vl:-� "w.. �'+..-^sr' ti T.,, r .^n .. . _ tY..-� _ � �".'�,� ( �?tl�. , - �''C%,t , , ,� A ani �;•� ' , ' 'BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (On&FS Per Building) School District T ? -d Building Department No. A.P. Number _ �J / 0— / Jurisdiction: City �ounty Property Owner ct r cy CAJ r_e �j s Property Location/Addres4 /4l/_A/rw Subdivison .�.. �ns Lot No. /S Residential Development Sq:�Footage No. of Living MHI Addition ,�C `(,Group, R) Units �— Commercial/Industrial 0 Sq. Foolagel , New Addition (Including Exterior Roofed Areas) Building Departme t Roe7kfative Date District Identification No. r Co �j�l �� ��, School District certifies that AIVA 1�4,IRL P, 0. J , (Applicant) 5D (o 0 C'16� n�ruw (Street Address) (Ph0502, one Number) V T' P� (City) (State) (Zip Code) t..13z has complied with the requirements of Resolution No. 4� by payment of $ representing ��R 1 -square feet. As 2926 $ FULL MITIGATION $ School District Representative Date Paid by Check # Bank Number _ Paid:by Cash Remarks: If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this prajectR,_ is being reviewed under the California Environmental Quality Act (CEQA), this projec a , be subject toy'f additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.wkt (11/94)amm DEC -21-1995 09:0-71 FROMTO 8956512 PfO1 r�ta�r 1&3 NGINEERING ' vil Er�pineers ! FUnners •, Surveyors December 21, 1995 Department of Development Servi BUILDING DEPARTMENT 1 469 Humboldt Road Chico, CA. 98928 Attn: Dave Wasney Subject: Weibel Residence Dean Mr. Wasney. The contractor has requested that to prvvidr, r wdt to vibrate. Wel immediately after the concrete is Very Truly Yours, . NQRTHSTAR ENI,HNEERING Michael McEnespy band �� uanly��1 m >F�� cam- . rte - w F0a r Its of the two #4 bars in the tap of the foundation be Wet set reby approve this change. The #4 bar wiU be wet set ed. vibrated and screeded. E COUNTY BuILNNG DEPARTKNI APPROVD i 12-7.1 -"i5 7671 "g" IZ-zl post -it® Fax Note . prom rs LE,J Co.IDept. U 1 L'b r Cy Phone!► PhoneR �7 5 a Fax s► Fsox 0 20 DECLARATION ORIVE CHICO, CALIFORNIA 95926 916.893-1600 Tr,T/11 f1 f1� CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... The Weibel Residence Date........ 10/03/95 Project Address........ Lot 15 Alms Bluff Drive Chico ��j o�s�2 Documentation Author... Marty Runnells Building Permit # Company................ Energy Calculation Svcs. i( Telephone .............. (916) 894-8466 Plan -Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File -95219S Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... 3681 sf v Single Family Detached / New Front Facing 0 deg (N) 1 2 Raised Floor (Package E) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall �R 19" 0.065 PLAN FRONT, FRONT -RIGHT, FRONT -LEFT LEFT, LEFT -FRONT, LEFT -BACK TO CRAWLSPACE, BACK, BACK -LEFT BACK -RIGHT, BASEMENT, RIGHT, RIGHT -BACK Door R-0 0.330 ENTRY Wall Rzn/a 0.575 MASSWALL Roof �R--O R-3) 0.025 VAULT Floor R-190.037 RAISED FLOORS1abEdge 0.900 TO EXTERIOR S1abEdge R-0 0.720 TO EXTERIOR SlabEdge R-0 0.500 TO CRAWLSPACE FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Door Front (N) 24.050 70 2 Drapes.Std None Yes Wood Window Front (N) 5.0 0,/800 2 Drapes.Std None Yes None WindowFront 27.0 0.670 2 es.Std None Yes Metal Window �,Front (N,) 172.0 0.670 2 Drapes . Std None Yes Metal Window Front (N) 8.0 0.820 2 Drapes.Std None Yes Metal Window Front (NE) 13.5 0.670 2 Drapes.Std None Yes Metal Window Front (NE) 4.0 0.820 2 Drapes.Std None Yes Metal Window Left (NE) 14.0 0.670 2 Drapes.Std None Yes Metal Window Left (E) 44.0 0.670 2 Drapes.Std None'' 2's�"' Metal Window Left (SE) 48.0 0.720 2 Drapes.Std ' <es Metal Window Back (SE) 53.5 0.670 2 Drapes.Std�A P e;, Metal Window Back (SE) 74.0 0.820 2 Drapes.Std e eta Window Back (SW) 64.0 0.820 2 Drapes.St ��� No Yes Metal Window Back (S) 56.0 0.670 2 Drapes Ne Yes Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.. ........ The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -95219S Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence FENESTRATION SPECIAL FEATURES/REMARKS # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Right (SW) 15.0 0.670 2 Drapes.Std None Yes Metal Window Back (S) 121.0 0.820 2 Drapes.Std None Yes Metal Window Back (SW) 42.5 0.670 2 Drapes.Std None Yes Metal Window Left (SE) 30.0 0.820 2 Drapes.Std None Yes Metal Window Left (SE) 10.0 0.670 2 Drapes.Std None Yes Metal Window Back (SW) 48.0 0.720 2 Drapes.Std None Yes Metal Window Back (S) 48.0 0.720 2 Drapes.Std None Yes Metal Window Right (W) 44.0 0.670 2 Drapes.Std None Yes Metal Skylight Front (N) 6.0.0.800 2 None None None Metal Skylight Left (E) 6.0 0.800 2 None None None Metal Skylight Right (W) 4.0 800 2 None None None Metal 0 THERMAL MASS l/ Area Thickness Type Exposed (sf) (in) Location/Comments ExteriorVert Yes 156 8.0 BASEMENT/WATERFALL S1abOnGrade No 250 4.0 BASEMENT S1abOnGrade Yes 70 4.0 BASEMENT -TYPICAL SlabOnGrade No 564 8.0 CMU RETAINING WALL InteriorHorz Yes 990 1.0 KIT./DIN./MUSIC/BATHS InteriorVert Yes 273 1.0 SHOWER/TUB ENCLOSURES HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type , Efficiency Location R -value Type Gas X0.930--"AFUE Crawlspace R-4.2 Setback ACSplit SEER Crawl space R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Storage_ Gasp-- -��.� �Ppelnsul-aton _ .2_-,,:� 60- EF;. — 50 SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations; and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Lenn Goldmann Name.... Company. Lenn Goldman & Associates Company. Address. 343 W. 4th Street Address. Chico, CA 95928 Phone... (916) 345-1161 Phone... License. Signed ..Ai .y�,Signed . . date ENFORCE NT ENCY Name.... Title... Agency.. Phone... Signed. ate DOCUMENTATION AUTHOR Marty Runnells Energy Calculation Svcs. 1907 Mangrove Ave. Ste D Chico, California 95926 (916) 894-8466 MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... The Weibel Residence Date........ 10/03/95 .Project Address ......... Lot 15 Alms Bluff Drive Documentation Author. Company .............. Telephone............ Compliance Method.... Climate Zone......... Chico .. Marty Runnells Energy.Calculation Svcs. (916) 894-8466 MICROPAS4 by Enercomp, Inc. .. 11 Building Permit Plan Check Date- Field ate Fie d Check/ Date MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration Products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets f certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 7801 thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36, inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. Design- Enforce- er ment COMPUTER METHOD SUMMARY Page 1 C -2R Project Title..... ... The Weibel Residence Date........ 10/03/95 Pr e t Add L t 15 Al Bl -F -F D o� c ress........ o ms u rive Chico Documentation Author... Marty Runnells Company ................ Energy Calculation Svcs. Telephone .............. (916) 894-8466 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... it Field Check/ Date MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 17.41 15.51 1.90 Space Cooling.........: 13.70 15.60 -1.90 Water Heating.......... 7.10 7.02 0.08 Total 38.21 38.13 0.08 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 3681 sf Single Family Detached New Front Facing 0 deg (N) 1 2 ReducedYear Raised Floor 1 42751 cf 3925 sf 3925 sf 884 sf 26.7 0 of FA 11.6 ft BUILDING ZONE INFORMATION (Package E) Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 3681 42751 1.00 Yes Setback 8.0 n/a 1 COMPUTER METHOD SUMMARY Page 2 . C -2R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 503 0.065 R-19 0 90 Yes None PLAN FRONT 2 Door 28 0.330 R-0 0 90 Yes None ENTRY 3 Wall 182 0.065 R-19 320 90 Yes None FRONT -RIGHT 4 Wall 37 0.065 R-19 330 90 Yes None FRONT -RIGHT 5 Wall 236 0.065 R-19 350 90 Yes None FRONT -RIGHT 6 Wall 62 0.065 R-19 355 90 Yes None FRONT -RIGHT 7 Wall 37 0.065 R-19 20 90 Yes None FRONT -LEFT 8 Wall 245 0.065 R-19 25 90 Yes None FRONT -LEFT 9 Wall 37 0.065 R-19 30 90 Yes None FRONT -LEFT 10 Wall 62 0.065 R-19 55 90 Yes None FRONT -LEFT 11 Wall 217 0.065 R-19 90 90 Yes None LEFT 12 Wall 80 0.065 R-19 85 90 Yes None LEFT -FRONT 13 Wall 165 0.065 R-19 115 90 Yes None LEFT -BACK 14 Wall 106 0.065 R-19 90 90 -No None TO CRAWLSPACE 15 Wall 255 0.065 R-19 180 90 Yes None BACK 16 Wall 80 0.065 R-19 135 90 Yes None BACK -LEFT 17 Wall 85 0.065 R-19 140 90 Yes None BACK -LEFT 18 Wall 60 0.065 R-19 145 90 Yes None BACK -LEFT 19 Wall 74 0.065 R-19 150 90 Yes None BACK -LEFT 20 Wall 134 0.065 R-19 170 90 Yes None BACK -LEFT 21 Wall 49 0.065 R-19 175 90 Yes None BACK -LEFT 22 Wall 60 0.065 R-19 200 90 Yes None BACK -RIGHT 23 Wall 160 0.065 R-19 205 90 Yes None BACK 24 Wall 74 0.065 R-19 210 90 Yes None BACK 25 Wall 196 0.065 R-19 225 90 Yes None BACK 26 Wall 49 0.065 R-19 235 90 Yes None BACK 27 Wall 264 0.065 R-19 180 90 Yes None BASEMENT 29 Wall 217 0.065 R-19 270 90 Yes None RIGHT 30 Wall 80 0.065 R-19 260 90 Yes None RIGHT -BACK 31 Wall 113 0.065 R-19 295 90 Yes None RIGHT -BACK 32 Wall 120 0.065 R-19 270 90 Yes None BASEMENT 33 Roof 135 0.025 R-38 320 19 Yes None VAULT 34 Roof 118 0.025 R-38 140 19 Yes None VAULT 35 Roof 291 0.025 R-38 170 19 Yes None VAULT 36 Roof 283 0.025 R-38 350 19 Yes None VAULT 37 Roof 408 0.025 R-38 0 19 Yes None VAULT 38 Roof 367 0.025 R-38 180 19 Yes None VAULT 39 Roof 401 0.025 R-38 90 19 Yes None VAULT 40 Roof 403 0.025 R-38 270 19 Yes None VAULT 41 Roof 87 0.025 R-38 .150 19 Yes None VAULT 42 Roof 87 0.025 R-38 210 19 Yes None VAULT 43 Roof 290 0.025 R-38 205 19 Yes None VAULT 44 Roof 282 0.025 R-38 25 19 Yes None VAULT 45 Roof 301 0.025 R-38 167 19 Yes None VAULT 46 Roof 301 0.025 R-38 167 19 Yes None VAULT 47 Floor 3041 0.037 R-19 0 0 No None RAISED FLOOR 1 ExteriorVert (Thermal Mass) 28 Wall 156 0.575 R-n/a 180 90 Yes None MASSWALL COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -95219S Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 48 SlabEdge 5 0.900 R-0 No TO EXTERIOR 49 SlabEdge 79 0.720 R-0 No TO EXTERIOR 50 SlabEdge 9 0.500 R-0 No TO CRAWLSPACE FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Door 24.0 Wood Hinged 0.570 350 90 0.88 0.78 Drapes.Std 2 Window 5.0✓ 2 None Fixed 0.800 350 90 0.88 0.78 Drapes.Std 3 Window 13.5 2 Metal Fixed 0.670 320 90 0.88 0.78 Drapes.Std 4 Window 13.5 2 Metal Fixed 0.670 20 90 0.88 0.78 Drapes.Std 5 Window 13.0✓ 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 6 Window 13.0✓2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 7 Window 10.5 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 8 Window 20.0✓ 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 9 Window 20.0✓2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 10 Window 31.5 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 11 Window 10.5 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 12 Window 13.0 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 13 Window 13.0 2 Metal Fixed 0.670 0 90 0.88 0.78 Drapes.Std 14 Window 4.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 15 Window 13.5 2 Metal Fixed 0.670 330 90 0.88 0.78 Drapes.Std 16 Window 13.5 2 Metal Fixed 0.670 30 90 0.88 0.78 Drapes.Std 17 Window 4.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 18 Window 4.0 2 Metal Slider 0.820 25 90 0.88 0.78 Drapes.Std 19 Window 14.0 2 Metal Fixed 0.670 355 90 0.88 0.78 Drapes.Std 20 Window 14.0 2 Metal Fixed 0.670 55 90 0.88 0.78 Drapes.Std 21 Window 13.0 2 Metal Fixed 0.670{ 90 90 0.88 0.78 Drapes.Std 22 Window 48.0 2 Metal Slider 0.720 115 90 0.88 0.78 Drapes.Std 23 Window 21.0 2 Metal Fixed 0.670 85 90 0.88 0.78 Drapes.Std 24 Window 10.0 2 Metal Fixed 0.670 90 90 0.88 0.78 Drapes.Std 25 Window 21.0 2 Metal Fixed 0.670 145 90 0.88 0.78 Drapes.Std 26 Window 20.0 2 Metal Slider 0.820 145 90 0.88 0.78 Drapes.Std 27 Window 25.0 2 Metal Slider 0.820 205 90 0.88 0.78 Drapes.Std 28 Window 15.0 2 Metal Fixed 0.670 175 90 0.88 0.78 Drapes.Std 29 Window 15.0 2 Metal Fixed 0.670 235 90 0.88 0.78 Drapes.Std 30 Window 30.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 31 Window 30.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 32 Window 10.0 2 Metal Fixed 0.670 180 90 0.88 0.78 Drapes.Std 33 Window 39.0 2 Metal Slider 0.820 150 90 0.88 0.78 Drapes.Std 34 Window 32.5 2 Metal Fixed 0.670 150 90 0.88 0.78 Drapes.Std 35 Window 32.5 2 Metal Fixed 0.670 210 90 0.88 0.78 Drapes.Std 36 Window 39.0 2 Metal Slider 0.820 210 90 0.88 0.78 Drapes.Std 37 Window 10.0 2 Metal Fixed 0.670 180 90 0.88 0.78 Drapes.Std 38 Window 30.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 39 Window 30.0 2 Metal Slider 0.820 135 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -95219S Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 40 Window 10.0 2 Metal Fixed 0.670 135 90 0.88 0.78 Drapes.Std 41 Window 10.0 2 Metal Fixed 0.670 225 90 0.88 0.78 Drapes.Std 42 Window 48.0 2 Metal Slider 0.720 225 90 0.88 0.78 Drapes.Std 43 Window 6.0 2 Metal Slider 0.820 170 90 0.88 0.78 Drapes.Std 44 Window 15.0 2 Metal Slider 0.820 140 90 0.88 0.78 Drapes.Std 45 Window 25.0 2 Metal Slider 0.820 200 90 0.88 0.78 Drapes.Std- 46 Window 21.0 2 Metal Fixed 0.670 200 90 0.88 0.78 Drapes.Std 47 Window 48.0 2 Metal Slider 0.720 180 90 0.88 0.78 Drapes.Std 48 Window 10.0 2 Metal Fixed 0.670 270 90 0.88 0.78 Drapes.Std 49 Window 21.0 2 Metal Fixed 0.670 260 90 0.88 0.78 Drapes.Std 50 Window. 13.0 2 Metal Fixed 0.670 270 90 0.88 0.78 Drapes.Std 51 Skylight 6.0 2 Metal Fixed 0.800 350 19 0.88 1.00 None 52 Skylight 6.0 2 Metal Fixed 0.800 90 19 0.88 1.00 None 53 Skylight 4.0 2 Metal Fixed 0.800 270 19 0.88 1.00 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Door 24.0 8 n/a 10 .5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 5.0 1 n/a 10 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 13.5 4.5 n/a 3 .33 n/a n/a n/a n/a n/a n/a n/a n/a .4 Window 13.5 4.5 n/a 3 .33 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 10.5 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 20.0 8 n/a 32.5 5 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 20.0 8 n/a 32.5 5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 31.5 4 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 10.5 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a' n/a 14 Window 4.0 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 13.5 4.5 n/a 3 .33 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 13.5 4.5 n/a 3 .33 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 4.0 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 4.0 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 14.0 3.5 n/a 2 .5 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 14.0 3.5 n/a 2 .5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 48.0 8 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 21.0 6.5 n/a 4 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 21.0 6.5 n/a 4 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 20.0 5 n/a 4 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 25.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 15.0 5 n/a 2. .5 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 29 Window 15.0 5 n/a 2 .5 n/a n/a n/a n/a. n/a n/a n/a n/a 30 Window 30.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 31 Window 30.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 32 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 33 Window 39.0 6.5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 34 Window 32.5 6.5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 35 Window 32.5 6.5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 36 Window 39.0 6.5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 37 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 38 Window 30.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 39 Window 30.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 40 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 41 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 42 Window 48.0 8 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 43 Window 6.0 2 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 44 Window 15.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 45 Window 25.0 5 n/a 4 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 46 Window 21.0 6.5 n/a 4 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 47 Window 48•.0 8 n/a 20 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 48 Window 10.0 5 n/a 4 .5 n/a n/a n/a n/a n/a n/a n/a n/a 49 Window 21.0 6.5 n/a 4 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 50 Window 13.0 6.5 n/a 4 .33 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (_in) Cap ivity R -value Location/Comments HOUSE 1 ExteriorVert 156 8.0 28.0 0.98 R-0.0 BASEMENT/WATERFALL 2 S1abOnGrade 250 4.0 28.0 0.98 R-.2.0 BASEMENT 3 S1abOnGrade 70 4.0 28.0 0.98 R-0.0 BASEMENT -TYPICAL 4 S1abOnGrade 564 8.0 28.0 0.98 R-1.5 CMU RETAINING WALL 5 InteriorHorz 990 1.0 24.0 0.67 R-0.0 KIT./DIN./MUSIC/BATHS 6 InteriorVert 273 1.0 24.0 0.67 R-0.0 SHOWER/TUB ENCLOSURES HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE Gas 0.930 AFUE Crawlspace R-4.2 0.880 ACSplit 10.00 SEER Crawlspace R-4.2 0.910 COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... The Weibel Residence Date........ 10/03/95 MICROPAS4 v4.02 File -95219S Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence Tank Type 1 Storage WATER HEATING SYSTEMS Number Tank in Energy Size Heater Type Distribution Type System Factor (gal) Gas PipeInsulation 2 .60 50 SPECIAL FEATURES/REMARKS External Insulation R -value R-10 HVAC SIZING Page 1 HVAC Project Title.......... The Weibel Residence Date........ 10/03/95 ro P t Add L 15 Al B1 ff jec ress........ of ms u Drive Chico Documentation Author.... Marty Runnells Company ................ Energy Calculation Svcs. Telephone .............. (916) 894-8466 Compliance Method....... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field C ec Date MICROPAS4 v4.02 File -952195 Wth-CTZ11S92 Program -HVAC SIZING User#-MP1333 User -Energy Calculation Svcs. Run -3681 SF- Residence GENERAL INFORMATION Floor Area........ ....... Volume ........ ............ Front Orientation.......... Sizing Location............ Latitude ... ...... ........ Winter Outside Design...... Winter Inside Desi!n....... Summer Outside Design...... Summer Inside Design....... Summer Range ................ Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3681 sf 42751 cf Front Facing 0 CHICO EXP STA 39.7 degrees 27 F 17047 70'F n/a 102 F Infiltration ..................... 78 F 8883 37 F n/a Yes Ducts ............................ Yes 2886 Yes 0.20 HEATING AND COOLING LOAD SUMMARY deg (N) Sensible Load .................... 93291 60616 Latent Load...................... n/a 12123 Minimum Total Load 93291 72739 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such, as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 27233 11485 Glazing Conduction ............... 30542 17047 Glazing Solar............ ...... n/a 18214 Infiltration ..................... 27034 8883 Internal Gain .................... n/a 2100 Ducts ............................ 8481 2886 Sensible Load .................... 93291 60616 Latent Load...................... n/a 12123 Minimum Total Load 93291 72739 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such, as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. LAND DEVELOPMENT BUILDING / ENVIRONMENTAL HEALTH - PERMIT CLEARANCE Building Permit No. - OWNERS NAME: NUMBER: PRINT'LAST NAME FIRST COUNTY ZONING DESIGNATION: /2 3 FLOOD ZONE: iC FLOOD MAP: Z S -U . APPROVED: CONDITIONALLY APPROVED:y RESOLVE PROBLEMS PRIOR TO APPROVAL: PARCEL CREATION BY DEEDS OR MAP DEED INFORMATION: DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO LEGAL ACCESS REQUIRED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: YES NO COMMENTS/CONDITION MAP INFORMATION: DATE OF RECORDING JV 4 /99 / ? %Y LOT % BOOK /00 PAGE COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES �o NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DIVISION UNLESS OTHERWISE NOTED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a 2 v ft.building setback from rig ht -of -way/•ee"terh"e of /4" r C -u& 3. Maintain a 100 ft. leachfield setback from all existing wells. 4. Maintain a ft. leachfield setback from 5. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. 6. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. 7. Connect to a public water supply. 8. Connect to a public sewer system. _ 9. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. 10. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ 11. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) 12. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010. 13. A. traffic mitigation fee for each new or additional living unit shall be paid. Pay the amounf `of $71V"-4 •' in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be andle to the PAwwing Dhdsaion. `•" as stated 14. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. 1� 15. Deer Mitigation fees are to be paid; if such fees have been adopted by the Butte County Board of Supervisors. �, z4 u X 16. Pay school impact mitigation fees. X 17. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II of the Butte County Code. _ 18. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. 19. If any cultural resources are encountered during ground disturbing activities, all work shall cease in the area of the find pending examination of the site by a professional archaeologist. This person would then be able to assess the site significance and suggest appropriate mitigation measures. 5Q 20. /vid Gvr`- �- S'a v.�c n• os Gil G�re�.. 22 23 24. 25. AIO 1N3Wd013A30 ONY1 3. inG .:10 AIN1100 5661 £ Z 10 0 a3ni303a LD 9/95 - CAVVP51 TORMS. K\BLDGPERM.CLR COUNTY OF Eur(E BUILUNG DEPT 0 C T 2 5 9995 Garey B. Weibel Post Office Box 41 Chico, California 95927 October 24, 1995 Butte County Building Dept. 7 County Center Drive Oroville, CA 95965 Attn: Alice Re: AP #011-410-163. Residence located at 141 Alm Bluffs Drive, Chico. Please be advised that applicant for building permit, identified above, has deleted the second kitchen, located in the grotto area underneath the house, from the house plan. We no longer desire to build and install a second kitchen. Thank you for your attention to this matter. Sincerely, Garey B. Weibel And when recorded mail to: Building Division #7 County Center Drive Oroville, Ca. 95965 05-35696 MJ 1 95-035696'1 Rec Fee 12.00 I Check 12.00 Recorded I Official Records I County of Butte I ' Candace J. Grubbs I Recorder I 9:55am 16 -Oct -95 I PUBL XX 3 AGRICULTURAL -STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is+adjacent to land or included within. an area zoned for agricultural .purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers, and from the pursuit of agricultural operations including, but not limited to cultivation. plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte. State of California, described as follows: 77-A rgeZ9 Date: fQ•—/Z��� PROPERTY OWNERS: State of California ) County of � � ) On AD / a � before me, �/ ` Z 'y� �� �v 7412y ���%� personally appeared `SKkI-7 ( i�3EG personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized.capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, Bet IIIIIIIIl1111111U111III IIIIIIII IIIII IIUIIII1111IIII11111114 executed the instrument. WITNESS my hand and official seal. �"`� OFF998804111IEAIILIIIII - '. W.Z.J. BROWN D NOTARY PUBLIC • CALIFORNIA N Y^ COUNTY OF BUTTE Signature Seal: MY Commission Expiros July 2o, 1997 W i•11/1111II1111111111IIIIIIIIIUIIIfU1111111111111111111IIUIIINfUUNl3 A.P. A.-1 VOTE TO RECORDER: DO NOT RECORD THIS SIDE � Ar Instructions for recording Agricultural Statement of Acknowledgement: 1. Insert the legal description of the property in the space provided on the other side of this form. The legal description is the narrative description of the property - which will be on your deed. If you don't have access to the deed, the Recorders Office can provide this information. ( The description may be handwritten or typed in the space provided or attached on a separate sheet if more space is required). 2. Property owners must sign in the presence of a Notary Public and have the form notarized. 3. Make a copy of the form and then take the original and copy to the Recorder's Office at 25 County Center Drive, Oroville (the Administration Center building). The Recorder will record both the original and copy. They will keep the original and return the copy to you. Just bring the copy back to the Building Division at 7 County Center Drive. RECORDER'S FEES: $6.00 - 1st. Page $3.00 - Each Additional Page RECORDER'S OFFICE HOURS: 9:00a.m. - 3:00p.m. (Monday - Thursday). OVER 5-35696 �. ORDER NO. BU -148071 BG DESCRIPTION ALL THAT CERTAIN REAL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, COUNTY OF BUTTE, DESCRIBED AS FOLLOWS: PARCEL I• LOT 15, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "THE BLUFFS AT SPANISH GARDEN", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 19, 1985, IN BOOK 100 OF MAPS, AT PAGE(S) 52 THRU 56. EXCEPTING THEREFROM A ONE FOOT NO ACCESS STRIP LOCATED ALONG THE SOUTHERLY BOUNDARY OF THE ABOVE DESCRIBED PARCEL OF LAND AS DEDICATED TO THE COUNTY OF BUTTE, AND AS SHOWN ON THE ABOVE REFERENCED MAP. PARCEL II: AN EASEMENT FOR INGRESS AND EGRESS OVER AND ACROSS SPANISH GARDEN DRIVE AND ALM.BLUFFS DRIVE, AS SHOWN. ON THAT CERTAIN MAP ENTITLED, "THE BLUFFS AT SPANISH. GARDEN"; -WHICH MAP WAS RECORDED IN THE OFFICE OF THE' RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 19, 1985, IN BOOK 100 OF MAPS, AT PAGE(S) 52 THRU 56. EXCEPTING THEREFROM ALL THAT PORTION LYING WITHIN THE BOUNDS OF PARCEL I, DESCRIBED HEREIN. PAGE 4 �Q " LO (7) ..... ..—.......�..— .. .... a., .w��. ..�/ . ..�. , • .mow+ ����tt? { , 1 ctt •r,•'i:, \t.:�. r i^. �'.:..+�•�7.{L'�•lry it�:JlwM�li�W�W�� •g1.7.'+�►'ni j �i[�S.'.' '{ y f.�( �, .%). •�Y :Y..J:i.i� j .... .—•. • �. �' .• • • / Y .. . ' • al'�: :7...• . til ,[ M LOT 14 13 ,� Is VCAL9 I's 200' i ! `► '. : _; ' SHE -.T 3 S EET 4 �f7'.: riAl�`::. x a . SH ET 5 7 i. 7g; 4s SHEET DIAGRAM .21 xo ro to 'II' IHI IE BLUFFS Air SPANESIFIL GARDEN BEING A PORTION OF SECTIONS 3 AND 4 T.21 N.,•R.2 E., M.D.B.aM. BUTTE COUNTY CALIFORNIA 'FOR MIK ASSOCIATES t , RESIDENTIAL 011-410-163 WEIBEL, GAREY f 141 ALM BLUFF DR, CHICO i. CONTR: ROBERT HILL SWIMMING POOL i t 95-2667 1" JOB FINALED (Da Z Z Signature V=OK O = Not OK =Not Applicable Not Ready MOBILE HOMES = Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements - Setbacks - Easements Date 2. Soils; Special MH Support Sketch Date 3. Sewer, Location -Test -Fall -C/O -Concrete Date 4. Water, Location -Test -Easement Needed (Sketch) Date 5. Electricity; Location-Clearances-Gmd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap; / /'1211. / /Nat. or/ /'L"ft./ /LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils-Size-DepthSpacing-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rttrs.-Connectors Shthg: Rfg: Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS Plans OK except #'s et acks-Easements _ of ; Compaction -Structure Stability ool Structure; Steel -Connections -Thickness Dea Men -Linin ec.; Receptacles and Lighting, Distance-GFI 5 ec.; Pool Lighting; 15 Volts-GFI 6. .; Enclosures; Conduit Entries -Terminals -Listed Alec.; Bonding; Metal w/5' -Circulating Equip. -Heater EI ;'Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. oxes Enclosures-Panelboards-Ins. to Main in Conduit Hp6 Department Approval 10 lumb.; Cir. Test -Water Supply Test ` �� I i Date 1 110 17 V Card B- Date Card B-1 Date 1 41 Card B-1 Date Card B-1 �� I J=OK O = Not OK = Not Applicable Not Ready RESIDENTIAL (Single & Duplex) ' =� Date UNDERFLOOR (Plans) OK except ff's Date FRAMING (Continued) 1. Zoning -Setbacks -Easements -Flood -Slope 45. -Hangers -Post Caps -Anchors -Connectors 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth ------------------- - -- - 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 6. Stemwalls, Garage; Steel- Bloc kouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except a's 16. Water Htr.: Vent -Access -Combustion Air -Baffle ---------------------- 17. Water Pipe: Test & Anchor -Nail Protection - ------------------ ------- 18. D.W.V.; Test -Fittings & Anchor -Nail Protection ---- --- -------------------------------------------------------- 19. Shower Pan. Test. First Floor -Tub Access 20. -Test -Tub & Shower. Second Floor -Tub Access 21. Gas Pipe: Size & Anchors -------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 ------------------------------------------------- -------- --- ------ Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except a's 22. Fixture & Transformer Clearance -Ins. Protection -------------------------------------------------------------------------- ----- 23. Elec. Receptacles Spacing -Lights & Switches at Doors 24. Size Boxes & No. of Conductors -Stapled -------------- 25, ----------- 25. Romex Installed Close to Edge of Studs & C J. ------------ ------------------------------------------------------- ....... .. 26. Equip. Ground made up wrMech. Fastners-Bond Gas & Water ----------- - --------- ------------------- ---- _.._... _---... ... .-. - 27. 2 Appliance Circuts in Kitchen & Conductor Size,GFI -- - ----------------------- ------.............. ... ... -- 22. Subfeed Wire Size ga. Cu or AI -A.0 Wire Size ' ga Cu or At ------- ---------- 29. Range Circ r I ga. Cu or AI -Oven Circ. 1 t ga. Cu or At Insulated Neutral ❑ Yes ❑ No -------- --------------------- ---------- ---- 30. Service-R.ser Conductors & Ground -Man Disconnect . --------------------------... 31. Equip Clearances Panel s- Motors- Mech Equip. 32. Clothes Closet Light -Shower Light -Spa Light - - ........ ....... . . ... 33 Smoke Detector --------------- - --- -. ........ ... ... .- .. ......... . . Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except n's 34. A C. Ducts Insulation & Support ------ ....... ... ........... 35. Vent Fan. Exhaust above insulation ------ --- --- -.. .. 36 Condensate Drain & Overflow. Size & Grade 37 Furnance-Vent: Access -Comb Air -Return Air Vent -115 outlet 38 Attic Access & Platform if Furnance in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except n s 39 S Is. Proper Material & Anchors 40 Walls Studs -Nailing. Spacing & Bracing -Plates -Sound 41 Bearing Walls over Girders & Floor Nailing 42 Draft Stop in Walls (rat proof) 43 Fire Stops. Furred Ceilings- Stags -Chases -Tub ------- -- - --- --- ._ ...- 44. Headers & Beam -Sze & Bearing 50. Garage Fire Protection Framing --- --------- ---------------------- 51. Property Line Firewall & Openings _ 52. Ext. Doors -One 3=Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. -Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls: Nailing -Bolts ________ 59. -Insulation -Wal Is-Cei Ii ngs ------------------- - 60. Infiltration -Walls -Windows -- ---------------------------------------------- -- Date Card B-1 Date Card B-1 ------------------ ------------------------ Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except a's 61. Ext. Steps -Door & Sidelight Protection -Landings 62' Smoke Detector ------------- ------------------------------- - - 63. Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor-Ducts-Mech. Protection .. .- ------------------------------- 64. Bedroom Exiting 65 G.F.I.& Bath Fixtures & Tub Access -Spa -- --. . - - - --------------------- 66. Elec. Trim & Subpanel: Breaker Sizes & Labels .--- ----------------------------- 67. Stags & Rails 68 Fireplace or Stove: Clearances -Hearth .._..------------------------------- - 69 Elec. Outlets at Wood Panel: Int. & Ext. ... .. -. ------------------------------ ---------- 70 Kit.Fixt. & Appliance: Grnd.-Air Gap -Cooking Clearance ... _ .. ------------------------------------ -- 71 Elec. Outlets & Receptacles at Kit. Counter ------------------------- ---------- 72 Garage Fire Door: Swing -Landing -Closer ...... ... ... ... .....-------------------- ----- ----- 73. A.C. Duct in Garage -Damper ...... ..................... ------------ -------- 74. Wtr Htr.. Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection . .-..-------------------------------- ---- 75. Plb . Elec. & Mech. Equip. Listed for Location . ...- - ......... --------------------------------- - 76. Elec. Receptacles in Garage: (G.F.I.)-Romex Protection -- --- --- ------------------------------------------------- 7, Insulation -Foam -Looked in Attic ❑ Yes -------------------------------------------- ----- 78. Guard Rads & Deck Construction -Post Caps .. .- --- ---------------------------------------- 79 -------- ---------------------------79 Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes -------------- 80. Following inslld Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No: Planters ❑ Yes ❑ No .. --- ---------------------------------------- 81 .---- ----------------------- 81. Stucco. Brown -Finish . ------------------------------------------- 82 A C Unit. D sconnect. Electrical. Plumbing 83 Vents Above Roof. Plbg -Appliance-Fireplace.-Clearance to Openings ....... - - - _. _..... --------------------- ------ 84 Water Well. Disconnect. Electrical, Plumbing - - ---------------------------- 85 Exterior Elec Trim. G F I. Receptacle -Underground 86 Ventilation Throughout House 87 Glass Protection 88 Corrections from Previous Inspections 89 Gas Test -Meters Tagged. Gas -Electric -- -- -------------------------------------- 90 Water & Sewer Connected -C/O to Grade -HD Approval 91 Energy Compliance Certificate -Other Certificates -------------------------- Date Card B-1 Date Card B-1 -----------------------­--- --------- Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OFDEVELQPMENTSERVICES - 7 County Center Drive - Oroville, California •95965 - Telephone • APPLICATIONAND PERMIT BUILDING DIVISION (916) 538-7541PEFIMIT NO. p P% T ASSESSOR PARCEL NUMBER 1713 1-410-10-1 zONt9 BUILDING PERMIT OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNERS MAIUNG ADDRESS CONTR . 18,000 CONTRACTOR'S NAME ROBERT HILL TELEPHONE m -1 ?6 CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 20,00 Permit Fee $ 189.00 ARCHITECT OR ENGINEER BACHMAN LICENSE NO. Plan Checking Fee $ 23.00 Energy Plan Checking Fee $ HIT ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 141 ALM BLUFF DR CHICO PERMITFEE $ 232.00 PLUMBINGPERMIT Filing Fee 20.00 Each Trap 7.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP Solar or heat pump water heater 23.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other POOL SPECIFY Water piping 15.00 15.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New P Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: MAST^R 91-511 Mobile Home S I G I W @20.00• PERMITFEE $ 35.00 Contractor ELECTRICAL PERMIT Filino Fee 20:00 Main Service OOOV OR LESS ( zooA OR LESS ) 23.00 Main Service ( L..A To I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class 8 ' G53 Lic. No. BJO �3-1 £'3 3$ OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. SO. OR ADDNS. ( 8 ACC. ) 3.5Q FT. NEW CONST, MULTI -OUTLET -OUTLET NON-RESID. ( BRANCH CIRCUITS ) 07.50 ( POWER SINGLE OUAPPARATUS ) 8 TLET CIR. Ex. Occup. (OUTLET OR FIXTURES) IL Q I•50 a 90 Ex. Occup. OUTLETS (REs o.)ea ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc . Wiring _POOL 23.00 23.00 PERMITFEE s 43.00 Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: 9-1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the ,Performance of the work for which this permit is issued. OSI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Q I—P d 1— 0 MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number EGA-`.. ZAZ -7L.,1'2_:7 —!14-- (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X�`-f u�/ Date 0-2A�� Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height.B Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 310 00 HAZ. D. F S IMPFLO CDF '/ PARCEL I. ISSU This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. Date 1-1/-�As_ PERMITEXPIRESON Receipt No. 3.2,' 6 "23 WHITE-D.D.S.-B. D. CANARY -ASSESSOR K -INSPECTOR GOLDENROD -APPLICANT Building Department rU OM: Environmental Health BJECT: Sanitation Clearance L -MLLif)wEL Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for bedroom mobile home. Other !' H_H..USE ONLY 1 5 ✓ •, Plat Plea Attached Plwr Plea AMAW Seat to B.D. / Hold final for: Final clearance O.K. for: NOTE: ' R/92 Health Specialist Date COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - 7 .County Center Drive — Oroville, balifprnia 95965 - Telephone APPLICATION AND PERMIT BUILDING DIVISION (916) 538-7541 PERMIT NO. ASSESSOR PARCEL NUMBER o — 410—leo ZONING BUILDING PERMIT OWNERWE j 15f: L TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS CONTRACTOR'S NAME ZDE�Ee_-r "I Lr L, TELEPHONE ' CONTRACTORS MAILING ADDRESS 4A ---A V j_ Fireplace CONSTRUCTION LENDER NON UNKNOWN Total Valuation $ o ®O�A Filing Fee $ 20,00 LENDER'S MAILING ADDRESS Permit Fee $ O ARCM ECTOR NGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS PERMITFEE $ ' Z PLUMBINGPERMIT Fling Fee 20.00 Each Trap 7.00 LAT NO. S UBDNIS IONS NAME PARCEL MAP Solar or heat pump water heater 23.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 is 0C. Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: �c)L. Mobile Home I S I GI W @20.00 PERMITFEE s 3S. 0 a Contractor ELECTRICAL PERMIT Filinq Fee 20.00 Main Service800V OR LESS ( 200A OR LESS ) 23.00 Main Service ( 200A TO I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class �- GS3 Lic. No. 3774Dq OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: 53"'1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier .LI...10 NEW CONST. DWELLING OCCUP. OR ADDNS. ( 8 ACC. BLOS. ) SO. 3.5¢ FT. NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS ) d SINGLE OUTLET CIR. Ex. Occup. (ourLEr OR FIXTURES ) 2L (L•50 BAIL SO EX. Occup. OUTLETS RESID.FIXED A_LNS. �EA ( � 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring p a 23.00 PERMITFEE $ 3• O Contractor MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number EC_b, 2f 2'7Lo 12'7 - 9 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. a X /' _ Date �U 2`t-�s. Signature of Applicant - ❑ Owner &-Contractor ❑ Agent An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee Is Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ f HAZ. 1 0. FEES I IMP I FLOOD I COF PARCEL PO HOI ISSUE This permit is hereby issued under the of the Butte County Code and/or indicated above for which fees have By PERMITEXPIRES ON applicable provisions Resolutions to do work been paid. Date (Date) Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT I til / Y BY: _I M P— DATE: 11I1G> JOB NO: 1jG�Q& PAGE I2 OF F IoM gip. NorthStar ENGINEERING Civil Engineers • Planners • Surveyors os oTN �J 2,. BUTM COUNTY BUILDING DEPARTMENT - APPROVED 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 1 POOL kWA LL - z""'m U►;MFog ALL M AT i of coMpA�TlO�1 PT. A �o P� , NALL 21 MINIM L�i'_'11 OF T�i� /0 G•��11.I.T C,O'IPA u �A FF N or2TlTT T ~vN 11�1_I✓ I N�- TN15 P?,1 AL 1 � :- NJ VA L V' L -j U o T L S T P. o A P P;-oVA L- P- A -P -A E-,- N �-7-5R-i C-� . �c �� �k`r�4CllEJ f (44Sr A3, BY: JMR NorthStar BUTTE COUNTY au � DATE: 11 /'16 / 95 JOB NO.: 5506. ENGINEERING 4 � �alaff, C M o iq PAGE 3 OF Civil Engineers Planners Surveyors 1 9 1m0 Ij .MAXIMUM SOIL 1211 8.1 LEVEL 0 EVELoMAXIMUM WATER LEVEL- O 0 0 #3 VERTICAL HORIZONTAL 6" O.C. E.W. ON WATERSIDE � 4 0 X #3 VERTICAL 8 HORIZONTAL Q f@ 12" O.C. E.W. ON SOIL SIDE 37 2" CLR, o o 1v 2" CLR. CONCRETE W/ F'c = 2500 PSI D o MIN. lad 28.DAY5 Q Q OPTIONAL CONSTRUCTION JOINT MINIMUM o SOIL ROUNDED CORNER AS NEEDED LEVEL ° 95% RELATIVE COMPACTION (TYPJ. o �o Z Q 0 o 0 0 0 0 - o NOTES: O � U g" 12" OIL- THIS DETAIL IS INVALID " - WITHOUT A LETTER OF APPROVAL STAMPED AND SIGNED BY LRA o ENGINEERING. 2. CONTRACTOR 15 RESPONSIBLE FOR MEETING ALL SETBACK REQUIREMENTS A5 5HOWN ON 5' - p" OTHER PLANS AND PROVIDING COMPACTION N TESTS AS REQUIRED BY OTSR PLAN5. TYPICAL POOL WALL NOT TO SCALE 0 NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: POOL WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-1600 �G. IL�- RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 ---------------------------- ---------- SOIL DATA ---------------------------------------------------- ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 62.4 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1. Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist; Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING:-------- ------ ADDED LATERAL LOADS ------- Vertical load. _ 0-plf Lateral Load Acting ...Ecc. (Toe side +) _ .0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 5.00 ft Toe Width = 0.00 ft Wall Ht. above soil = 0.00 ft Heel Width = 5.00 ft Key Depth = 22.00 in Total Width = 5.00 ft Key Width = 12.00 in Thickness = 10.00 in Key Dist. to Toe = 0.670 ft SUMMARY Pressure @ Toe = 1,490 psf Factors of Safety: Pressure @ Heel = 84 psf Overturning = 4.35 :1 Allowable Press. = 1,500 psf Sliding = 1.80 :1 Eccentricity = 8.94 in Resultant Within Middle Third 1 -Way Shear @ Toe = 0.0 psi Allowable Shear = 85.00 psi 1 -Way Shear @Heel = 8.9 psi ------------- -------------------=--------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,040.0.# Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 888..9 # Factor of Safety = 1.80 (-)Friction = 983.3 # Add'1 Force Req'd = 0 #. ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel--. f'c = 2,500 psi ACI 9.1 Pressure = 2,086 117 psf Fy = 60,000 psi Mu - Upward = .0 3,080 ft-# Using SP @ Heel Yes Mu - Downward = 0 5,250 ft-# -------- Rebar Choices -------- Mu - Design = 0 2,170 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ NoGood'in 14.81 in vu = 0.00 8.87 psi #5 @ NoGood in 22.96 in vn=2(f'c)1/2*.85= 0.00 85.00 psi #6 @ NoGood in 32.59 in Rebar CL To Edge = 3.50 2.50 in #7 @ NoGood in 44.44 in. Depth to steel = 6.50 7.50 in #8 @ NoGood in 48.00 in Ru = Mu/bd^2 = 0.0 42.9 #9 @ NoGood in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ NoGood in 48.00 in NORTHSTAR TITLE: WEIBEL RESIDENCE 6,111 ENGINEERING 0.28 DESCR: POOL.WALL 20 DECLARATION DRIVE 0 .0.00 0 CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-1600 PC1IGJ 0.00 RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- 0 (Factored values shown for concrete stems) 0 0 Pg 2 of.2 0 <-------------- Stem Designs. -------------- > Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 5.00 4.00 3.67 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Concrete 1,200 Thickness (nominal) = 12.00 16.00 20.00 20.00 in Rebar Size = # 3 # 3 # 3 # 3 . 625 Rebar Spacing = 12.00 12.00 12.00 12.00 in Rebar Placed at Edge Edge Edge. Edge 0 DESIGNDATA.....' ....:............................................ 0 fb/Fb + fa/Fa = 0.000 0.004 0.007 0.367 Lateral Load @ Ht. = 0 53 94 1,326 # MOMENT..... Allowable =. 3,375 4,695 6,015 6,015 ft-# I Actual = 0 18 42 2,210 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 85.00. psi Actual = 0.00 0.00 0.00 2.91 psi Embedment Length Req'd = 12.00 12.00 12.00 6.00 Wall Weight _ 150.0 200.0 250.0 250.0 psf Rebar Depth = 10.31 14.31 18.31 18.31 in MASONRYDATA............................................................ f'm = psi Fs = psi Grouting Special Inspection n :Es / Em = Short Term Increase = CONCRETEDATA........................................................... f'c = 2,500 2,500 2,500 2,500 psi Fy = 40,000 40,000 .40,000 40,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- �- Overturning Moments. Resisting Moments -) Origin of Force: # ft ft-# ------- .# ft -------------- ft-# ---------------- -------- Heel Active. Press. = ------ 1,062 1.94 --------- 2,064 Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe = Axial Load on Wall = Load @ Proj. Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = Active Press. -.-------- TOTALS = 11040 ! --->> Distances from front edge of 2,058 3,933 8,962 --------- -------- --------- footing bottom (not key) 1,833 3.33 6,111 -22 0.28 -6 0 .0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0 0.00 0 0 0.00 0 1,200 0.81 967 0 0.00 0 625 2.50 1,562 275 1.17 322 0 0.00 0 Active Press. -.-------- TOTALS = 11040 ! --->> Distances from front edge of 2,058 3,933 8,962 --------- -------- --------- footing bottom (not key) BY: DATE: ct-e2 JOB NO: 5z50*0 PAGE 1(2) OF -,\/ E-7 I er.-- L /i? E7. \x// -\LL Fo P- '5TEF-'L 67'THF-7- ,NFOIZMA,TIOW) Q';olL OAK 111& PsF Z- NorthStar ENGINEERING Civil Engineers o Planners a Surveyors BUTTE COUNTY allILDINODEPARTMENT 4PPROVED '. 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 F S S 1 C 0537HD Do C) r- V-1 cx.3 re --r. LL TEF 0�;OIL MAX IN, &Z Pe7F CU'r6l DE POUL o T HERS) 0 NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: BASEMENT WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/16/95 916-893-1600P�-'----------------------RetainPRO(tm) 2D (C)1989-92 ------------------------------ ENERCALC ------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on.Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in. .....Max. Active = 0 psf Surcharge over Toe- = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel: Yes Soil Density = 110.0 pcf @ Toe. : Yes Soil Ht over Toe = 0.0 in -------= ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral -Load Acting ...Ecc. (Toe side +) = 0.00. in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/.-] = 0.00 ft ...dist'. to end = 0.00 ft Footing Type Line ----------------------- ----- WALL &FOOTING DATA ------------------------- Retained Height = 9.50 ft Toe Width = 3.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.67 ft Key Depth = 32.00 in Total Width = 4.67 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = .3.000 ft SUMMARY Pressure @ Toe = 1,316 psf Factors of Safety: Pressure @ Heel = 113 psf Overturning = 1.97 :1 Allowable Press. = 1,500 psf Sliding = 1.53 :1 Eccentricity = 7.86 in Resultant Within Middle Third 1 -Way Shear @ Toe = 27.4 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.6 psi --------------------- ----------------------------- SLIDING CHECK ---------------------- -------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,638.8 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,680.6 # Factor of Safety = 1.53 (-)Friction = 834.3 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DES.I.GN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,843 158 psf Fy = 60,000 psi Mu - Upward = 6,669 91 ft-# Using SP @ Heel Yes Mu - Downward = 945 586 ft-# -------- Rebar Choices -------- Mu - Design = 5,724 495 ft-# -- Toe -- -- Heel -- One-Way-Shear: - #4 @ 11.80 in 11.70 in vu = 27.40 0.59 psi #5 @ 18.30 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 25.97 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 35.41 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 46.63 in 46.20 in Ru = Mu/bd"2 = 88.0 .6.1 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 .@ 48.00 in 48.00 in L' NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: BASEMENT WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/16/95 916-893-1600 P(yl. 18 RetainPRO(tm) 2D (C) 1989-92 ENERCALC -----------------------------=--- STEM DESIGN ----------------------.------------ (Factored values shown for concrete stems) Pg 2 of 2 <-------------- Stem Designs--------------> Stem Construction Data < At Various Heights Above Ftg. > ---------------------------------------------------------------7------- DESIGN HT. ABOVE FTG. = 12.00 10.00 2.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Concrete Thickness (nominal) _ 6.00 6.00 10.00 10.00 in Rebar 'Size = # .5 # 5 # 5 # 5 Rebar Spacing = 12.00 12.00 12.00 12.00 in Rebar Placed atEdge Edge Edge Edge DESIGNDATA...............................:.......................... fb/Fb + fa/Fa = 0.000 0.000 0.329 0.668 Lateral Load @ Ht. _ 0 0 1,434 2,301 # MOMENT..... Allowable = 5,331 5,331 10,911 10,911 ft-# Actual = 0 0 3,586 7,288 ft-# SHEAR....... Allowable = 85.00 85.00 85.00 85.00. psi Actual = 0.00 0.00 12.06 20.18 psi Embedment Length Req'd = 12.00 12.00 12.00 6.90 Wall Weight = 75.0 75.0 125.0 1.25.0 psf Rebar Depth = 4.19 4.19 8.19 8.19 in MASONRYDATA....................:....................................... f'm = psi Fs = Psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA........................................................... f'c = 2,500 21500 2,500 2,500 psi Fy = 60,000 60,000 60,000 60,000 psi ---------------- - SUMMARY OF FORCES & MOMENTS ---------------------- 1- Overturning Moments. -I- .Resisting Moments -� Origin of Force: # ft ft-# --------- ------- # ft -------------- ft-#. ---------------- -------- Heel Active Press. = ------ 1,654 3.50 5,788 Soil over Heel = 874 4.25 3,717 Toe Active Press. _ -15 0.33 -5 Soil over Toe = 0 0.00 0 Sloped Soil @ Heel = 0 0.00 0 Adjacent Ftg. Load = 0 0.00 0 0 0.00 0 Surcharge @ Heel = 0 0.00 0 Surcharge @ Toe = 0 0.00 0 0 0.00 0 Axial Load on Wall = 0 0 0.00 0 Load @ Proj. Wall = 0 0.00 0 Averaged Stem Wts. = 1,.363 3.40 4,636 Added Lateral Load = 0 0.00 0 Footing Weight = 700 2.34 1,636 Key Weight _ 400 3.50 1,400 Vert. Componant of = 0 0.00 0 Active Press.--------- --------- -------- --------- TOTALS = 1,639 5,783 3,337 11,389 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: BASEMENT WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/16/95 916-893-1600 P�, �� RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 --------------------------------------------------------------------------- ---------- SOIL DATA ------------- -----= ADDED VERTICAL LOADS ------ Allowable Bearing 1,500 psf Axial DL on Stem = 600 plf Active Lateral = 30.0 psf Axial LL on Stem = 400 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in ...Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,0=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht.over Toe 0.0 in -------- ADJACENT FOOTING -------- -----= ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil to start = 0.00 ft At Wall Face [+/-] = , 0.00 ft ...dist. ...dist.'to end = 0.00 ft Footing Type . :.-Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 9..50 ft Toe Width = 3.00 ft Wall Ht..above soil = 2.00 ft Heel Width. = 1.67 ft Key Depth = 32.00•in Total Width _ 4.67 ft Key Width = 12.00 in Thickness = .12:00 in Key Dist. to Toe = 3.000 ft ----------------=-------------- --------------------------- ---- SUMMARY -------------------------------- -------------------------------- Pressure @ Toe = 1,233 psf Factors of Safety: Pressure @ Heel = 625 psf Overturning = 2.32 :1 Allowable Press. = 1,500 psf Sliding = 1.63 :1 Eccentricity = 3.06 in Resultant Within Middle Third 1 -Way Shear @ Toe = 30.0 psi Allowable Shear = 85.00 psi 1 -Way Shear @. Heel = 0.3 psi ------------------------- SLIDING CHECK -=---------------------------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,638.8 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,680.6 # Factor.of Safety = 1.63 (-)Friction = 984.3 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = .2,500 psi ACI 9.1 Pressure = 1,760 892 psf Fy = 60,000 psi Mu - Upward = 7,083 330 ft-# Using SP @ Heel Yes Mu - Downward = 945 586 ft-# -------- Rebar Choices -------- Mu - Design = 6,138 255 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 10.99 in 11.70 in vu = 30.04 0.31 psi #5 @ 17.03 in. 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 24.18 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 32.97 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 43.41 in 46.20 in Ru- Mu/bd-2 = 94.4 3.1 #9 @ 48.00 in 48.00 in Min. Rebar Ratio- 0.0018 #10 @ 48.00 in 48.00 in NGRTHSTAR 0.00 TITLE: WEIBEL RESIDENCE 0.00 ENGINEERING 0.00 DESCR: BASEMENT WALL 600 20 DECLARATION DRIVE 1,363 3.40 700 2.34 400 CHICO, CALIFORNIA 95926 0 JOB #: 5506 BY:JMR @ 11/16/95 916-893-1600 TZo F RetainPRO(tm) 2D (C) 1989-92 ENERCALC - ---------------------------------- STEM DESIGN ---------------------------------- (Factored values shown for concrete stems) Pg 2 of 2 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 12.00 10.00 2.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Concrete Thickness (nominal) = 6.00 6.00 10.00 10.00 in Rebar Size = # 5 # 5 # 5 #. 5 Rebar Spacing = 12.00 12.00 12.00 12.00 in Rebar Placed at Edge Edge Edge Edge DESIGNDATA...... ................................................. fb/Fb + fa/Fa = 0.000 0.000 0.329 0.668 Lateral Load @ Ht. _ 0 0 1,434 2,301 # MOMENT..... Allowable = 5,331 5,331 10,911 10,911 ft-# Actual 0 0 3,586 7,288 ft-# SHEAR...... Allowable = 85.00 85.00 85.00. 85.00. psi Actual = 0.00 0.00 12.06 20.18 psi Embedment Length Req'd = 12.00 12.00 12.00 6.90 Wall Weight = 75.0 75.0 -125.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 8.19 in MASONRYDATA............................................................. f1m _ psi Fs = Psi. Grouting Special Inspection n : E s / :Em = Short Term Increase = CONCRETEDATA............................................................. f'c = 2,500 2,500 2,500 2,500 psi Fy = 60,000 60,000 . 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ------ --------------- origin of Force: Heel Active Press. _ Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load Surcharge @ Heel = Surcharge.@ Toe- Axial oe Axial Load on Wall = Load @ Proj. Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = �- Overturning Moments Resisting Moments -� # ft ft-# # ft ft-# -- - - - - -- - - - - ----- - - - - --- - - - - -- -- - - - --------- 1,654: 3.50 5,788 -15 0.33 -5 0 0.00 0 0 0.00 0 0 0 0.00 0 0 0.00 0 Active Press. --------- TOTALS = 1,639. ! ---» Distances from front edge of 874 4.25 3,717 0 0.00 0 0.00 0 0.00 0 0.00 0. 0.00 600 3.42 1,363 3.40 700 2.34 400 3.50 0 0.00 5,783 3,937. footing bottom (not key) 0 0 0 0. 0 2,050 4,636 1,636 1,400 0 13,439 GEC -04-1995 09:29 FROM November 28, 1995 Job Number 95111T Horton Enterprises P.O. Box 1477 Chico, GA 95927 Subject: Swimming Pool Garey Weibel Home Alm Bluffs Drive -9 n : amount i; California Ladies and Gentlemen: TO 8956512 P.01 Qttl a& &Jr- - LRA ENGINEERI Pr- 1--14115 3230 SUNRISE BLVD., SUITE 5 RANCHO CORDOVA, CA 95742 PHONE: 916-631.4455 NOV 3 0 1995 _ Ilf It is proposed to construct a pool on the downhill side of the subject residence. The site was observed on November 22, 1995. We have also reviewed details prepared by NorthStar Engineering. All foundations must be carried into either compact native soils or engineered fill. The fill must extend a minimum of 3 feet beyond the lower pool wall. The wall foundation must extend deep enough that the footing influence area does not daylight. The fill must be graded to prevent surface water from running down slope across the fill to mitigate erosion. A subsurface drain should be installed next to the pool wall to prevent any water from accumulating underground and saturating the fill. Proper drainage is essential to increase the stability of the slope. Very truly yours, L -RA ENGINEERING Q�oTGJ�Un'� h No. 15555 EV. 12 31-97 Laver L.. Roper, C.E. 15555 LLR:ds OFCf� cc: NorthStar Engineering lab+.951 1 It >fr Post -It"' brand fax -transmittal memo 7611 1 # of pages ► RAV E Fftm JE-FF Co. C� Popt.Phurrolaex j FaxN r d:5 Z Fax# AW.J. x) Ciurfwa Sacramento Walruwt (;leek 916-fiz 7 -.1455 976-929-9267 5 7 0-Q4J-G i :• 3 chiu) Sarna (:nil QM491-0304 408-462-17417 TOTAL P.01 IN RESIDENTIAL PLAN CHECIQNG GUIDE SINGLE FAMILY DWELLING, DUPLEX AND MISCELLANEOUS ONLY OWNER: ��t/ ,�� O BUILDING PERMIT NUMBER: PLAN CHECKER: ASSESSOR PARCEL NUMBER: GENERAL Zoning requirements: (sideyards and number of permitted living units). Valuation. Plans signed by designer. Proper description. ,.Eof work on application. xisting violations on property. aItems on data sheet; (Impact fees, Health, Developer fees, License law, etc.). t.r iRecorded notice of violation. 1. PLOT PLAN: . Complete parcel size and dimensions. Setbacks, sideyards, easements, etc. Other buildings or structures. Grading, fills, and drainage. Flood hazard. Special conditions on creation map, (noise, C.D.F., fire sprinklers, non-combustible, and foundations). FAU & FAS road setback. Building or utilities,across lot lines (Record form). FLOOR PLAN: Complete to scale plan with dimensions. Required windows for light and ventilation (Section 1205). Required windows for second exit (Section 1204). kylights (Chapter 34 & Section 5207). Human impact glass (Section 5406). Required room sizes, ceiling heights (Section 1207). F.C.I. in baths, garage, kitchen, and exterior outlets (Article 210-8): ight fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. Locations of water heater, heating and cooling equipment, other electrical or gas equipment. age firewall, door size, and closer (Section 503(d)(3) ). 1 - 3'0" exterior exit door (Section 3304 (f). replace and wood stove location, alcoves and clearance. S oke detectors (Section 1210). Plumbing ffixtures, water closet clearances and shower size. 1. Standard bracing or engineered design (Table 25V). 2. Unusual shape, size, or split level house requiring lateral design. 3. Clerestory requiring balloon framing and/or engineering. 4. Three story building requiring engineered calculations and plans. 5. Foundation plan complete enough to construct building. 6. Floor construction details complete enough to construct building. 7. Elevations and wall construction details complete enough to construct building. 8. Roof construction details complete enough to construct building. 9. Fireplace construction details and call if necessary. 10. Rafter ties or bearing ridge beam. 11. Garage door or porch header sizes. 12. Stud heights. 13. Adobe soils - special foundation design. 14. Retaining walls requiring design. 15. Special�Inspection required. May 1995 3.2 RESIDENTIAL PLAN CHECKING GUIDE SINGLE FAMILY DWELLING, DUPLEX AND MISCELLANEOUS MISCELLANEOUS ITEMS TO LOOK OUT FOR: y details: landings, rise and run, head clearance, handrails (Section 3306). uardrail details (Section 1711 and 33066). Brick or stone veneer (Chapter 30). erior plaster - weep screeds (Section 4706). Proper roof pitch for roof covering (Chapter 32). Roof covering type - (fire hazard). oam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts. 9 Two exits on three-story dwellings (Section 3303 and see Mezzanines -1716). ttic access and ventilation (Section 3205). Underfloor access and ventilation (Section 2516). Combustion air for fuel burning appliances - L.P.G. requirements. oise requirements on duplexes. nergy design. Flashing at all exterior openings. D.F. responsible area requirements. BY: -J M P, DATE: 11/9"--/ JOB NO: 45r;lo PAGE 9-. OF b - hStar ENGINEERING Civil Engineers • Planners • Surveyors - SCHEDULE g��oW i v 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 For Ke,�- Y n SPT H=o" KEY_�.JHE2EocGulZS !^ jl ��= I /�. i L � ',moi\�Q�• C \\ e DOW L- CI Row) PIAN V) t?.,-�,J >=oo T I G NTS SHA 3L 85, 4:r57 W-01�>AP, Dl s �M��D• 14 �b I o�� f✓1 �,� I 22 IN1FG.5-1� 7 r- P� Eu�o�� aL- . I -J/ M10. ra. EXTto IIJT 2. �XPoS�1� � f�oGK SHALL �� � � �,q N � ►,�J �T P� 1 o�z -i`o PaU � WALL- H[—�-IC.-�HT #r- I- <2 (1Gk6 SFe-�ING Fo le- PTH = olI DE #5 DoI,.ICL. C I Roi.j) GIiJG Fofz KAY DEPTH = I�j1 I2` SHA 3L 85, 4:r57 W-01�>AP, Dl s �M��D• 14 �b I o�� f✓1 �,� I 22 IN1FG.5-1� 7 r- P� Eu�o�� aL- . I -J/ M10. ra. EXTto IIJT 2. �XPoS�1� � f�oGK SHALL �� � � �,q N � ►,�J �T P� 1 o�z -i`o PaU � NORTHSTAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT w����� �(`'iGJ� D�iNGI'i JOB NO. LOCATION LO I K2 AL-" P2LUFF12 p(L. DATE I I - 20_'T�7 CODES: Uniform Building Code, 1991 Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 19.88 Edition AITC, Timber Construction Manual: MATERIALS: Concrete: f'c = 2500 psi @ 28 Days Masonry: f'm = 1500 psi Mortar: f'c = 1800 psi,,Type "S" Grout: f'c = 2500 psi @.28 days Steel Reinforcing: A-615 Grade 40 for #4 and smaller A-615 Grade 60 for #5 and larger \,. Structural Steel: ASTM A-36 �..``. Steel Pipe: ASTM A53 Grade B Steel Tubing: ASTM A500 Grade A or B 1`';itMachine Bolts, Anchor Bolts: ASTM A307 Grade A ;.Wood Connectors: Simpson Strong -Tie or equal. - 5 -;Wood: Light Framing: Const Grade Douglas Fir Struct Lt Framing: #2 Grade D.F. Joists & Planks: #2 Grade D.F. Beams & Stringers: #1 Grade D.F. Posts & Timbers: #1 Grade D.F. - Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Glue -Lam Timber: ANSI/AITC A190.1-1983 Std 25-9 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: psf Floor Live Load: psf Seismic Zone Wind Speed: mph Exposure: — Method 2 used unless otherwise noted. Allowable Soil Bearing (psf) I�Oo ARE SPECIAL INSPECTIONS REQUIRED ? O GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not - the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of 2 O BY: J M ?- DATE: I/ I JOB NO: PAGE 2 OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 D T R N oF: Pc2 ,J 5, L,,::r2 R5:, A L L H �� K -F- Y AT� �HoPzTtE�i I MAPA IT A� A L L o ISI AF -5 L H E�A F- = 31 (Z4.) = 7, 4 K F ,' . g. I �� 2�o PSI 2�- A L- AH rA [�T Fob � �%•�-� I G-� N . I N �"O �oL I D ; ;zo G�= _ . r DDI,J�L HT PA GI HAx.) FoPC, 5--' PSR Fool (2 �0►�1� IZ' GAL.GQ ri0\IS r --,i F., e =,, � oN FoL.Lo 1,J] 1el BY: DATE: JOB NO: PAGE OF NofthStar ENGINEERING Civil Engineers * Planners 9 Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 G A FoR 10' H161H l,,JALA, tAT,. =1.2K LAT�PAL C MIDI-)' Z - 7 of LJ A, L, L- rz 12' H 1 r--� H P= � Y 1: of WALL-. FOIL , K -5Y 755,-FTH F �fF,16-IHT �71,1') 1 IJ F, PT H F, p Tc). G A FoR 10' H161H l,,JALA, tAT,. =1.2K LAT�PAL C MIDI-)' Z - 7 of LJ A, L, L- rz 12' H 1 r--� H P= � Y 1: of WALL-. FOIL , K -5Y 755,-FTH GALGUI.ATIO�J'�7 ON FoLLbW'l�(,q PA��� A L �fF,16-IHT �71,1') 1 IJ FAC, I �J cm,t,,x.) f=o.zrl FOOT 12,' GALGUI.ATIO�J'�7 ON FoLLbW'l�(,q PA��� .z I BY: DATE: 119 C7 JOB NO: (157 PAGE 4 OF NorthStar ENGINEERING Civil Engineers 9 Planners e Surveyors 1 42- r-_ 5i SCHEDULE 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 �� >��J �L �2 Ro �) SPT H NTS /<1 F . - = ,I!��!: `DDf��- it o A fel V I t?.., OF: t=oO T I P<5lL,Jt?--L- WAU- Hr--Ir-;iHT # * P 0 " e� L- (Z Po 5,P�IrJ6j F,9V- IK rl- y DEPTH SPACOC�Fob K-e:,Y P�GPTH = 1Lll 8� �'- O II o.G. .I�o DO►..I�LS o I. Do�„1L� 5I -NA 3L. 4�7 p- 4- 11 d) '�IF:G. EQLI '� L- . �-J/ MN . 6�7.11 5XT5-t-]Glol'� IIJTO 2. EXPO': 7 P- C? G K NORTHS✓TAR ENGINEERING 20 DECLARATION DRIVE TITLE: WIEBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09./95 916-893-1600 PG _r RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------- ------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL.on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill.Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in --------ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) _ .0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) _ *0.00 ft. Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing.Type Line ---------=------------------ WALL & FOOTING DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth = 14.00 in Total Width = 3.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist.: to Toe = 1.500 ft SUMMARY Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. = 1,500 psf Sliding = 1.50 :1 Eccentricity = 4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear. = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.0'0 in (-)Passive Pressure = 586.8 # Factor*of Safety = 1.50 (-)Friction = 491.2 # Add'1 Force Req'd = 0 # _ ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = .1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8. @ 48.00 in 46..20 in Ru = Mu/bd-2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00,:;pn 48.00 in 0 NORTHSI�R TITLE: WEIBEL RESIDENCE. ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95.926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P� ,� ------------- ------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN. Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0.plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over -Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -=-----=---- ADDED LATERAL LOADS ------- Vertical load =. 0 plf Lateral Load Acting ... Ecc. (Toe side +) = 0.00 in - On Stem Above Soil = 0.00 psf Footing�Width (perp). = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil .dist. to start _ 0.00 ft At Wall Face [+/-) = 0.00 ft ...dist. to end = 0.00 ft Footing.Type Line -=-------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2:00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft SUMMARY Pressure @ Toe = 1,362 psf Factors of Safety: Pressure @ Heel = 176 psf Overturning = 2.26 :1 Allowable Press. = 1,500 psf Sliding = 1:.58 :1 Eccentricity = 6.17 in Resultant Within Middle Third. 1 -Way Shear @ Toe = 18.1 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 3.7 psi -- - - - - - - - - - - - - - - - - - - - - - - - - - -- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil.@ Toe Not Used = 0.00 in (-)Passive Pressure = 1,125.0 # Factor of Safety = 1.58 (-)Friction = 769.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------- ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,907 247 psf Fy = 60,000 psi Mu - Upward = 3,261 278 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 ft-# -------- Rebar Choices -------- Mu -Design = 2,841 704 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 18.10 3.68 psi #5 @ 20.26 in 18.13 in vn=2(f1c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd 2 = 43.7 8.7 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in' 48.00 in NORTHS2 R 34.00 in TITLE: WIEBEL RESIDENCE = 5..00 ft ENGINEERING 12.00 in DESCR: RETAINING WALL = 12.00 in 20 DECLARATION DRIVE 3.000 ft ft-# Mu - Design = 6,191 CHICO, CALIFORNIA 9592A ft-# SUMMARY JOB #: 5506 BY:JMR @ 11/09/95 Pressure @ Toe = 916-893-1600 pG 7 ------------- ------------------------------------------------------ psf Factors of Safety: RetainPRO(tm) 2D (C)1989-92 ENERCALC vn=2(f'c)1/2*.85= CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 ----------------------------------------------- ---------- SOIL DATA ------------- 2.07 :1 2.50 -------------------------- ------ ADDED VERTICAL --------- LOADS ------ psf Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral =. 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe _ 0.0 psf Backfill Slope =. 0.0:1 in Surcharge over Heel _ 0.0 psf (horiz:vert,O=Level:) 48.00 in Using Surcharge to resist 0.250 Passive Lateral = 250 pcf overturning @ Heel Yes 0.00 Soil Density = 110.0 pcf @ Toe Yes 1.56 Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load _ 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0..00 in On Stem Above Soil = 0.00 psf_ Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil . ...dist. to start = 0.00 ft At Wall.Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA -------------------------- Retained Height = 10.00 ft Toe Width = 3.00 ft Wall Ht. above soil = .2.00 ft Heel Width = 2.00 ft Key Depth = 34.00 in Total Width = 5..00 ft Key Width =. 12.00 in Thickness = 12.00 in Key Dist. to Toe _: 3.000 ft ft-# Mu - Design = 6,191 940 ft-# SUMMARY Choices -------- Pressure @ Toe = 1,373 psf Factors of Safety: psi vn=2(f'c)1/2*.85= Pressure @ Heel = 170 psf Overturning = 2.07 :1 2.50 Allowable Press. = 1,500 psf Sliding = 1.56 :1 Ru = Mu/bd"2 = Eccentricity = 7.80 in Min. Rebar Ratio = 0.0018 in Resultant Within Middle Third 32.68 in 35.09 in 1 -Way Shear @ Toe = 29.8 psi Allowable Shear = 85.00 psi in 1 -Way Shear @ Heel = 4.8 psi in 48.00 in ----------------------------- @ SLIDING CHECK 48.00 in Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety = 1.56 (-)Friction = 964.6 # Add'1 Force Req'd = .0 # FOOTING DESIGN f'c ---Toe--- --Heel-- . ACI 9.1 Pressure = 1,923 238 psf Mu - Upward = 7,136 251 ft-# Mu - Downward = 945 1,191 ft-# Mu - Design = 6,191 940 ft-# One -Way Shear: Choices -------- vu = 29..81 4.77 psi vn=2(f'c)1/2*.85= 85.00 85.00 psi Rebar CL To Edge = 3.'50 2.50 in Depth to steel = 8.50 9.50 in Ru = Mu/bd"2 = 95.2 11.6 23.97 Min. Rebar Ratio = 0.0018 in #7 f'c = 2,500 psi Fy = 60,000 psi Using SP @ Heel Yes -------- Rebar Choices -------- -- Toe -- -- Heel -- #4 @ 10.89 in 11.70 in #5 @ 16..89 in 18.13 in #6 @ 23.97 in 25.73 in #7 @ 32.68 in 35.09 in #8 @ 43.03 in 46.20 in #9 @ 48.00 in 48.00 in #10. @ 48.00 in 48.00 in NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-160.0 RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 7 ------------------------------------------------------------------------ ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) _ 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1, Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in .On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth = 14.00 in Total Width = 3.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. = 1,500:psf Sliding = 1.50 :1 Eccentricity = 4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ------------ ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 72.0.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factor of Safety = 1.50 (-)Friction = 491.2 #. Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- . f'c = 2,500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu.- Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7. @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-1600 .C� RetainPRO(tm) 2D (C).1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg.l of 2 -------------------------------------------------------------------------7------ ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial.DL on Stem = 0 plf Active Lateral = Axial LL on Stem = 0 plf. .....Slope Active .30.0.psf =. 0.,0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0.:1 Surcharge. over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250.pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0:in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Addll Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] _ .0.00 ft .:.dist. to end = 0.00 ft Footing Type Line ----------------- - ---------- WALL & FOOTING DATA ------------------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 16.00 in Total Width = 4.00 ft Key Width = 12.00.in Thickness = 12.00 in Key Dist. to Toe = 2.000:ft SUMMARY Pressure @ Toe = 1,356 psf Factors of Safety: Pressure @ Heel = 132*psf Overturning = 2.19 :1 Allowable Press. = 1,500 psf Sliding = 1.19 :1 Eccentricity = 6.58 in Resultant Within Middle Third 1 -Way Shear @ Toe = 17.9 psi Allowable Shear. = 85.00 psi 1 -Way Shear @ Heel = 3.9 psi ---------- ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 680.6 # Factor of Safety = 1.19 (-)Friction = 744.2 # Add'1 Force Req'd = 0 # ----------------=----------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f1c = 2,500 psi ACI 9.1 Pressure = 1,898 185 psf Fy = 60,000 psi Mu - Upward = 3,226 239 ft-# Using SP @ Heel Yes Mu -Downward = 420 981 ft-# -------- Rebar Choices -------- Mu - Design = 2,806 742 ft-# -- Toe -- -- Heel -- One-Way.Shear: #4 @ 13.0.7 in 11.70 in vu _ 17.88 3.87 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6. @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 43.1 9.1 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NOR-THSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-89.3-1600 fC:I Id RetainPRO(tm) 2D.(C)1989-92 ENERCALC ----------------------------------=--------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 ------------------------------------------------ ---=------ SOIL DATA ------------- -------------------------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = .0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel : Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = .0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load _ 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in. On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall. = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start - 0.00 ft At Wall Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing Type Line --------------------------=- WALL & FOOTING DATA ------------------ ------ Retained Height = 10.00 ft Toe Width = 2.33 ft Wall Ht. above soil = 2.00 ft Heel Width = 4.00 ft Key Depth = 16.00 in Total Width = 6.33 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2:250 ft SUMMARY Pressure @ Toe = 1,228 psf Factors of Safety: Pressure @ Heel = 678 psf Overturning = 3.60 :1 Allowable Press:. = 1,500 psf Sliding = 1.22 :1 Eccentricity = 3.65 in Resultant Within Middle Third 1 -Way Shear @ Toe = 22.4 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 13.7 psi -------------------------------- SLIDING CHECK------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used =. 0.00 in (-)Passive Pressure = 680.6 # Factor of Safety 1.22 (-)Friction = 1,508.2 # Add11 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe -r- --Heel-- f1c = 2,500 psi ACI 9.1 Pressure = 1,719 950 psf Fy = 60,000 psi Mu - Upward = 4,409 5,405 ft-# Using SP @ Heel Yes Mu - Downward = 570 8,774 ft-# -------- Rebar Choices -------- Mu - Design = 3,839 3,369 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 22.42 13.67 psi #5 @ 20.26 in 18.13 in vn=2(f1c)1/.2*.85= 85.00 85.00 psi #6. @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 59.0 41.5 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in BY: J�- II�-- DATE: II r2 JOB NO: 6 0& PAGE II OF O :R TAINI�J `NO SGA L E% NortlfStar 20 DECLARATION DRIVE ENGINEERING CHICO, CALIFORNIA 95926 Civil Engineers • Planners • Surveyors 916-893-1600 �otJ�T�U�TIo�I; ,JOINT;. FOR PLAINS .T a • p 5-1>z Pte. 4 MIIML4M ExTr-:-N, 51:0 �Ho�N __. F0Z APP IT10�-J AL IN -2 DoL J E 1, A� PG1, 4- A L L ALL FooTlC�. NORTHSTAR ENGINEERING 20 Declaration Drive .Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT W i% �Fi �i % ��.G� JOB NO. LOCATION LoT I,-:2' A LM PPL -U FSS Pg.. [3U 7Te, Co. DATE CODES: Uniform Building Code, 1991 Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: Concrete: f'c = 2500 psi @ 28 Days Masonry: f'm = 1500 psi Mortar: f'c = 1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days Steel Reinforcing: A-615 Grade 40 for #4 and smaller A-615 Grade 60 for #5 and larger Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B Steel Tubing: ASTM A500 Grade A or B =^Machine Bolts, Anchor Bolts • ASTM A307 Grade A �.; y Wood Connectors: Simpson Strong -Tie or equal. 'Wood: Light Framing: Const Grade Douglas Fir Struct Lt Framing: #2 Grade D.F. , Joists & Planks: #2 Grade D.F. Beams & Stringers: #1 Grade D.F. Posts & Timbers: #1 Grade D.F. Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Std 25-9 Glue -Lam Timber: ANSI/AITC A190.1-1983 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: psf Floor Live Load:_ psf Seismic Zone : Wind Speed: 80 mph Exposure: G Method 2 used unless otherwise noted. Allowable Soil Bearing (psf) • ISO O ARE SPECIAL INSPECTIONS REQUIRED ? No GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 . of Z3 BY: ,J -";?- DATE: II �(�J JOB NO: D PAGE: OF a: C 07?1520 Exp.q t A /fin 11-11 1 1 NorthStar Engineering Civil Engineers • Planners • Surveyors 20 Declaration Drive Chico, CA 95926 (916) 893-1600 w TYF. I N ;a HI 8'-O II ,_ o II 41_011 I ,,� f 2 - ' G ao �1 � � �� t✓ P- "72 Z) 24 0 61. 14-11 / �D � 4fG, 7 Ib11 n r o all w TYF. I N ;a RETAINING WALL sip` t. —z- GD`1 T ;LJlJO!-.4! To p�TTONl L4 9 �aNTlr1 ;off I. r� vo` P_AG� Fes,✓KF{LL UNTIL 2-0 DAYS NiiiJ. Z. Go►JGF-FiT Fi �- a DAYS. R- r G ; ALL>✓>z 1 HI 8'-O II ,_ o II 41_011 P- 14-11 / I % o I Oil �: -I_ L (L 1011 . 10) loll RETAINING WALL sip` t. —z- GD`1 T ;LJlJO!-.4! To p�TTONl L4 9 �aNTlr1 ;off I. r� vo` P_AG� Fes,✓KF{LL UNTIL 2-0 DAYS NiiiJ. Z. Go►JGF-FiT Fi �- a DAYS. R- r G ; ALL>✓>z 1 RIC C 0s3590 BY: Ex.0 JOB NO: N•orthStar 20 Declaration Drive DATE: Engineering Chico, CA 95926 PAGE: OF (916) 893-1600 > C11 Civil Engineers - Planners - Surveyors I, 121 -7 4- a p N P F2�16, 1-1 AgoVC- 10'l, CIO V �7 0 0 . C'. N A, O Z r-7 ev 1 11 0. C— P37o 74:5:1 1�1 IQUO —10 c-2 L4 0 L� I (f2 �,J e2 U-JTIL- \,-Jo 7 A\ Al2- RETAINING WALL 0 'IQ ED Hi 101- 11 -oil loll Typ. loll 1011 P37o 74:5:1 1�1 IQUO —10 c-2 L4 0 L� I (f2 �,J e2 U-JTIL- \,-Jo 7 A\ Al2- RETAINING WALL 0 'IQ ED Hi 101- 11 -oil loll -577 loll 1011 P37o 74:5:1 1�1 IQUO —10 c-2 L4 0 L� I (f2 �,J e2 U-JTIL- \,-Jo 7 A\ Al2- RETAINING WALL NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P(a, 4- ------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC ------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- / ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem. = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0,0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist . Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in --------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) _ 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below-Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist..to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------- -------------------- Retained Height = 2.00 ft, Toe Width = 0.50 ft Wall Ht. above soil = 2.00 ftp Heel Width = 1.00 ft Key Depth = 0.00 in Total Width = 1.50 ft Key Width = 0.00 in Thickness = 12.00 in Key Dist. to Toe = 0.000 ft SUMMARY =_______________________________ Pressure @ Toe = 620 psf Factors of Safety: Pressure @ Heel = 244 psf Overturning = 4.20-:1 Allowable Press. = 1,500 psf Sliding = 2.39 :1 Eccentricity = 1.31 in Resultant Within Middle Third 1 -Way Shear @ Toe = 0.0 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 120.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 125.0 # Factor of Safety = 2.39 (-)Friction = 162.1 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 86.9 342 psf Fy = 60,000 psi Mu - Upward = 101 21 ft-# Using SP @ Heel Yes Mu - Downward = 26 29 ft-# -------- Rebar Choices -------- Mu - Design = 75 8 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 0.00 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 1.2 0.1 #9 @ .48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P�.Cj RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- (Factored values shown for concrete stems) Pg 2 of 2 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT..ABOVE FTG. _. 4.00 2.00.. 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Thickness (nominal) = 6.00 6.00 8.00 in Rebar Size = # 5 # 5. # 5 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge: Edge DESIGNDATA .......................................... fb/Fb + fa/Fa = 0.000 0.000: 0.016 Lateral Load @ Ht. = 0 0 102 # MOMENT..... Allowable = 2,793 2,793. 4,188 -ft-# Actual = 0 0 68 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi Actual = 0.00 0.00 0.76 psi Embedment Length Req'd = 12.00 12.00 6.00 Wall Weight = 75.0 75.0 100.0 psf Rebar Depth = 4.19 4.19. 6.19 in* MASONRYDATA............................................................ f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA.............................................................. f'c = 2,500 2,500 2,500 psi Fy = 60,000: 60,000 60,000 psi ------------- - SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments Resisting Moments Origin of Force: # ft ft-# ------- # ----- ft --------- ft-# ---------------- -------- Heel Active.Press. = ------ 135 1.00 --------- 135 Soil over Heel = 73 1.33 .98 Toe Active Press. _ -15 0.33 -5 Soil over Toe = 0 0.00 0 Sloped Soil @ Heel = 0 0.00 0 Adjacent Ftg. Load = 0 0.00 0 0 0.00 0 Surcharge @ Heel = 0 0.00 0 Surcharge @ Toe 0 0.00 0 0 0.00 0 Axial Load on Wall = 0 0 0.00 0 Load @ Proj. Wall = 0 0.00 0 Averaged Stem Wts. = 350 0.8.0 279 Added Lateral Load = 0 0.00 0 Footing Weight _ 225 0.75 169 Key Weight = 0 0.00 0 Vert. Componant of = 0 0.00 0 Active Press. --------- --------- -------- --------- TOTALS = 120 130 648 546 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR:,RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #:-5506 BY:JMR @ 11/09/95 916-893-1600 RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA -------------`- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf,-- Axial DL on Stem = 600 plf Active Lateral = 30.0 psf Axial LL on Stem = 400 plf .....Slope Active = 0.0 `. psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1, Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel : Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in ` -------- ADJACENT FOOTING -------- ------ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 2.00 ft Toe Width = 0.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.00 ft Key Depth = 0.00 in Total Width = 1.50 ft Key Width = 0.00 in Thickness = 12.00 in Key Dist. to Toe = 0.000 ft SUMMARY Pressure @ Toe = 1,065 psf Factors of Safety: Pressure @ Heel = 1,133 psf Overturning = 8.04 :1 Allowable Press. = 11'500 psf Sliding = 3.64 :1 Eccentricity = 0.09 in Resultant Within Middle Third 1 -Way Shear @ Toe = 0.0 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 120.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 125.0 # Factor of Safety = 3.64 (-)Friction = 312.1 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,568 1,669 psf Fy = 60,000 psi Mu - Upward = 197 93 ft.-# Using SP @ Heel Yes Mu - Downward = 26 29 ft-# -------- Rebar Choices -------- Mu - Design = 171 64 ft-# -- Toe -- -- Heel -- one-Way Shear: #4 @ 13.07 in 11.70 in vu = 0.00 0.00 psi #5 @ 20.26 in' 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in *7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd-2 = 2.6 0:8 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #1"0 @ 48.00 in 48.00 in t NORTHSTAR. TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB '#: 5506 BY:JMR' @ 11/09/95 916-893-1600 P(�q- 7 RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- (Factored values shown for concrete stems) Pg 2 of 2 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. _ 4.00 2.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Thickness (nominal) = 6.00 6.00 8.00 in Rebar Size _ # 5 # 5 # 5 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge Edge DESIGNDATA.............................................................. fb/Fb + fa/Fa _ 0.000 0.000 0.016 Lateral Load @ Ht. _ 0 0 102 # MOMENT..... Allowable = 2,793 2,793 4,188 ft-# Actual = 0 0 68 ft-# SHEAR...... Allowable = 85.00. 85.00 85.00 psi Actual = 0.00 0.00 0.76 psi Embedment Length Req'd = 12.00 12.00 6`.00 Wall Weight = 75.0 75.0 100:0 psf Rebar Depth = 4.19 4'.19 6.19 in MASONRYDATA............................................................ f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = . Short Term Increase = CONCRETEDATA.............................................................. f'c = 2,500 2,500 2,500 psi Fy = 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments Resisting Moments -� Origin of Force: # ft ft-# # ft ----- --------- ft-# -=-------------- Heel Active Press. = -------- ------ 135 1.00 --------- 135 ------- Soil over Heel = 73 1.33 98 Toe Active Press. _ -15 0.33 -5 Soil over Toe = 0 0.00 0 Sloped Soil @ Heel = 0 0.00 0 Adjacent Ftg. Load = 0 0.00 0 0 0.00 0 Surcharge @ Heel = 0 0.00 0 Surcharge @ Toe = 0 0.00 0 0 0.00 0 Axial Load on Wall = 0 600 0.83 500 Load @ Proj. Wall = 0 0.00 0 Averaged Stem Wts. = 350 0.80 279 Added Lateral Load = 0 0.00 0 Footing Weight = 225 0.75 169 Key Weight = 0 0.00 0 Vert. Componant of = 0 0.00 0 Active Press. --------- --------- -------- --------- TOTALS = 120 130 1,248 1,046 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 Pte. 8 RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 --------------------------------------------------------------------------=----- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below-Soil ...dist. to start - 0.00 ft At Wall Face [+/-] _ 0.00 ft ...dist. to'end = 0.00 ft Footing Type Line ----------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 4.00 ft Toe Width = 1.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.25 ft Key Depth = 6.00 in Total Width = 2.25 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe 0.750 ft SUMMARY Pressure @ Toe = 891 psf Factors of Safety: Pressure @ Heel = .193 psf Overturning = 2.74 :1 Allowable Press. = 1,500 psf Sliding = 1.63 :1 Eccentricity = 2.90 in Resultant Within Middle Third 1 -Way Shear @ Toe = 2.8 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral'Pressure = 360.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 281.3 # Factor of Safety = 1.63 (-)Friction = 304.8 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- fic = 2,500 psi ACI 9.1 Pressure = 1,247 270 psf Fy = 60,000 psi Mu - Upward = 551 60 ft-# Using SP @ Heel Yes Mu - Downward = 105 141 ft-# -------- Rebar Choices -------- Mu - Design = 446 80 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 2.79 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd^2 = 6.9 1.0 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in I NORTHSTAR 257 TITLE: WEIBEL RESIDENCE -5 ENGINEERING DESCR: RETAINING WALL 0 20 DECLARATION DRIVE 0 0 0.00 CHICO,.CALIFORNIA 95926 0 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 PG,, 0 RetainPRO (tm). 2D (C)1989'-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- 0.00 0 (Factored values shown for concrete stems) 0.00 Pg -2 of 2 0 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 6.00 4.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete 75 Thickness (nominal) = 6.00 6.00 8.00 in Rebar Size = # 5 # 5 # 5 1,697 Rebar Spacing = 24.00 24.00 24.00, in Rebar Placed at Edge Edge Edge DESIGNDATA............................................................... fb/Fb + fa/Fa = 0.000 0.000 0.130 Lateral Load @ Ht. = 0 0 408 # MOMENT ...... Allowable = 2,793 2,793 4,188 ft-# Actual = 0 0 544 ft-# SHEAR...... Allowable = 85.00 85.00 85.00'psi -Actual = 0.00 0.00 4.17 psi Embedment Length Req'd = 12.00 - 12.00 6.00 Wall Weight = 75.0 75.0 100.0 psf Rebar Depth: = 4.19 4.19 6.19 in MASONRYDATA................................................ :............. f'm. = psi Fs = psi Grouting' Special Inspection m: n : Es / Em:- Short Term Increase Short = CONCRETEDATA:........................................................... f'c = 2,500 2,500 .2,500 psi Fy : = 60,000 60,000 60,000 psi --------=---------------- SUMMARY OF FORCES & MOMENTS ----------------------- �- Overturning Moments Resisting Moments -� Origin of Force: Heel Active Press. _ Soil over Heel Toe Active Press.' _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe = Axial Load on Wall = Load @ Proj . Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = ## ft ft-# # ft ft-# 375 1.67 625 -15 0.33 0 0.00 0 0.00 Active Press. --------- TOTALS = 360 ! --->> Distances from front edge of 257 1.96 503 -5 0 0.00 0 0 0.00 0 0 0 0.00 0 0 0.00 0 0. 0 0.00 0 0 0 0.00 0 0 550 1.31 721 0 337 1.13 380 75 .1.25 94 0 0.00 0 --------- -------- 620 1,219 --------- 1,697 footing bottom (not key) NbRTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 Pte, 1Q RetainPRO(tm) 2D (C) 1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 600 plf Active Lateral = 30.0 psf Axial LL on Stem = 400 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,0=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel : Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING ----=--- ----=- ADDED LATERAL LOADS ------- Vertical load 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil, ...dist. to start = 0.00 ft At Wall Face [+/-j = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line - --------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 4.00 ft Toe Width = 1.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.25 ft Key Depth = 6.00 in Total Width = 2.25 ft Key -Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 0.750 ft SUMMARY Pressure @ Toe = 1,089 psf Factors of Safety: Pressure @ Heel = 884 psf Overturning = 4.03 :1 Allowable Press. = 1,500 psf Sliding = 2.04 :1 Eccentricity 0.47 in Resultant Within Middle Third 1 -Way Shear @"Toe = 3.9 psi Allowable.Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------- ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil'Friction = 0.250 Lateral Pressure = .360.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 281.3 # Factor of Safety = 2.04 (-)Friction = 454.8 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,583 1,285 psf Fy = 60,000 psi Mii - Upward = 769 223 ft-# Using SP @ Heel Yes Mu - Downward = 105 141 ft-# -------- Rebar Choices -------- Mu - Design = 664 83 ft-# -- Toe.-- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 3.87 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2_*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to. steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in. Ru = Mu/bd-2 = 10.2 1.0 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in i NORTHSTAR ft TITLE: WEIBEL RESIDENCE ft ----- --------- ENGINEERING -------- 375 DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 1.96 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P�, �I RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------- ------------------- STEM DESIGN ---------------------------------- 0 0.00 (Factored values shown for concrete stems) Pg 2 of 2 0 <-------------- Stem Designs.----------- ---> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 6.00 4.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete 0 Thickness (nominal) = 6.00 6.00 8.00 in Rebar Size = # 5 # 5 # 5 0 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge Edge 1.31 DESIGN DATA........ 0 0.00 ................... fb/Fb + fa/Fa = 0.000 0.000 0.130 Lateral Load @ Ht. = 0 0 408 # MOMENT..... Allowable = 2,793 2,793 41188 ft-# Actual = 0 0 544 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi Actual = 0.00 0.00 4.17 psi Embedment Length Req'd.= 12.00 12.00 6.00 Wall Weight = 75.0 75.0 100.0 psf Rebar Depth = 4.19 4.19 6.19 in MASONRYDATA............................................................. f1m = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA............................................................ f'c = 2,500 2,500 2,500 psi Fy = 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments -I- Resisting Moments -1 Origin of Force: Heel Active Press. _ Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe = Axial Load on Wall = Load @ Proj. Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = # ft ft-# ------- # ft ----- --------- ft-# -------- 375 ------ 1.67 --------- 625 257 1.96 503 -15 0.33 -5 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 600 1.33 800 0 0.00 0 550 1.31 721 0 0.00 0 337 1.13 380 75 1.25 94 0 0.00 0 Active Press. --------- TOTALS = 360 620 1,819 2,497 --------- >> Distances from front edge of footing bottom (not key) t % NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600PG , 12 RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 -of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem _ 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel.: Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below-Soil ...dist.'to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------ ------------- Retained Height = 6.00 ft' Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth - 14.00 in Total Width = 3.00 ft Key Width - 12.00 in Thickness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY Pressure @ Toe 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. = 1,500 psf Sliding = 1.50 :1 Eccentricity = 4.6.4 in Resultant Within Middle Third 1 -Way Shear @ Toe. = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel =. 0.0 psi ------------- ----------------------------- SLIDING CHECK -----7------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factor of Safety = 1.50 (-)Friction = 491.2# Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35..09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd-2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48..00 in NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P� 15 RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- (Factored values shown for concrete stems). Pg 2 of 2 <-------------- Stem Designs--------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 8.00 6.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Thickness (nominal) = 6.00 6.00 10.00 in Rebar Size = # 5 # 5 .#. 5 Rebar Spacing = 24.00 24.00 24:00 in Rebar Placed at Edge Edge Edge DESIGNDATA.............................................................. fb/Fb + fa/Fa = 0.000 0.000 0.329 Lateral Load @ Ht. = 0 0 918 # MOMENT..... Allowable = 2,793 2,793 5,583 ft-# Actual = 0 0 1,836. ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi Actual = 0.00 0.00 7:34 psi Embedment Length Req'd = 12.00 12.00 6.' 00 Wall Weight = 75.0 75.0 125.0 psf Rebar Depth = 4.19 4.19 8:19 in MASONRYDATA.............................................................. f'm = psi Fs = psi Grouting Special Inspection n Es / Em = Short Term Increase - CONCRETEDATA........................................................... f'c = 2,500 2,500 2,500 psi Fy = 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments Resisting Moments -� Origin of Force: # ft ft-# ------- # ----- ft --------- ft-# ---------------- -------- Heel Active Press. = ------ 735 2.33 --------- 1,715 Soil over Heel = 440 2.67 1,173 Toe Active Press. _ -15 0.33 -5 Soil over Toe = 0 0.00 0 Sloped Soil @ Heel = 0 0.00 0 Adjacent Ftg. Load = 0 0.00 0 0 0.00 0 Surcharge @ Heel = 0 0.00 0 Surcharge @ Toe = 0 0.00 0 0 0.00 0 Axial Load on Wall = 0 0 0.00 0 Load @ Proj. Wall = 0 0.00 0 Averaged Stem Wts. = 900 1.89 1,700 Added Lateral Load = 0 0.00 0 Footing Weight = 450 1.50 675 Key Weight = 175 2.00 350 Vert. Componant of = 0 0.00 0. Active Press.-=------- --------- -------- --------- TOTALS = 720 1,710 1,965 3,898 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 F<�,`q, RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 600 plf Active Lateral = 30.0 psf Axial LL on Stem = 400 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) :Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel-: Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- 'Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] _ 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth - 14.00 in Total Width = 3.00 ft Key Width - 12.00 in Thickness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY Pressure @ Toe = 1,217 psf Factors of Safety: Pressure @ Heel = 760 psf Overturning = 2.95 :1 Allowable Press. = 1,500 psf Sliding = 1.71 :1 Eccentricity = 1.39 in Resultant Within Middle Third 1 -Way Shear @ Toe = 11.3 psi Allowable Shear = 85:00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factor of Safety = 1.71 (-)Friction = 641.2 #. Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f1c = 2,500 psi ACI 9.1 Pressure = 1,753 1,095 psf Fy = 60,000 psi Mu - Upward = 1,848 254 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,612 2 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 11.30 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd-2 = 24.8 0.01 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR 0.33 TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 0 20 DECLARATION. DRIVE 0 CHICO, CALIFORNIA 95926 0.00 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600��� 0 RetainPRO(tm) 2D (C)1989-92 ENERCALC ----------------=---------------- STEM DESIGN ---------------------------------- 0 (Factored values shown for concrete stems) 0 Pg 2 of 2 0.00 <-------------- Stem Designs --------------> 0 Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 8.00 6.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Thickness (nominal) = 6.00 6.00 10.00 in Rebar Size = # 5 # 5 # 5 0 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge Edge DESIGNDATA ................ ....... .................................... 2.00 350 fb/Fb + fa/Fa = 0.000 0.000 0.329 0.00 Lateral Load @ Ht. = 0 0 918 # MOMENT..... Allowable = 2,793 2;793 5,583 ft-# Actual = 0 0 1,836 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi Actual = 0.00 0.00 7.34 psi Embedment Length Req'd = 12.00 12.00 6.00 Wall Weight _ 75.0 75.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 in MASONRYDATA............................................................. f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA ................................................... ..... f'c = 2,500 2,500 2,500 psi Fy = :60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments Resisting Moments -� Origin of Force: # ft ft-# --------- # ft ------- ----- --------- ft-# ---------------- -------- Heel Active Press. = ------ 735 2.33 1,715 Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel- Surcharge eel Surcharge @ Toe Axial Load on Wall = Load @ Proj . Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = 440 2.67 1,173 -15 0.33 -5 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 600 1.92 1,150 0 .0.00 0 900 1.89 1,700 0 0.00 0 450 1.50 675 175 2.00 350 0 0.00 0 Active Press. --------- --------- TOTALS = 720 1,710 2,565 .5,048 !--->> Distances from front edge of .footing bottom (not key) NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 FG 110 -------------------------------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in' .....Max. Active 0 psf Surcharge over Toe = 0.0 psf Backfill Slope - 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height- 8.00 ft Toe Width = 2.00 ft - Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.00 ft Key Width = 12.00 in Thickness = 12.00- in Key Dist. to Toe = 2.000 ft _______________ SUMMARY Pressure @ Toe = 1,362 psf Factors of Safety: Pressure @ Heel = 176 psf Overturning = 2.26 :1 Allowable Press. = 1,500 psf Sliding = 1.58 :1 Eccentricity = 6.17 in Resultant Within Middle Third 1 -Way Shear @ Toe = 18.1 psi Allowable Shear = 85:.00 psi 1 -Way Shear @ Heel = 3.7 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,125.0 # Factor of Safety = 1.58 (-)Friction = 769.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,907 247 psf Fy = 60,000 psi Mu - Upward = 3,261 278 ft-# Using SP @ Heel Yes. Mu - Downward = 420 981 ft-# -------- Rebar Choices -------- Mu - Design = 2,841 704 ft-# -- Toe -- -- Heel -- One-Way Shear:. #4 @ 13.07 in 11.70 in vu = 18.10 3.68 psi #5 @ 20.26 in 18.13 in vn=2(f,c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00'in 46.20 in Ru = Mu/bd"2 = 43.7 8.7 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR ft TITLE: WEIBEL RESIDENCE ft ENGINEERING -------- 1,215 DESCR: RETAINING WALL ------- 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 3.42 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P(::�, 17 RetainPRO(.tm) 2D (C)1989-92 ENERCALC ------------------ --------------- STEM DESIGN ---------------------------------- 0 0.00 (Factored values shown for concrete stems) Pg 2 of 2 0 <-------------- Stem Designs --------------> 0.00 Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 10.00 8.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete 0. 0.00 Thickness (nominal) 6.00 6.00 10.00 in Rebar Size = # 5 # 5 # 5 0 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge Edge 0 DESIGN DATA............................................................. 0 . fb/Fb + fa/Fa = 0.000 0.000 0.779 2.00 Lateral Load @ Ht. = 0 0 1,632 # MOMENT..... Allowable = 2,793 2,793 5,583 ft-# Actual 0 0 4,352 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi .Actual = 0.00 0.00 13.90 psi Embedment Length Req'd = 12.00 12.00 8.14 Wall Weight = 75.0 75.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 in MASONRY DATA.................................................:......... f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA... ............ ..................... ..................... f'c = 2,500 2,500 2,500 psi Fy = 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments -I- Resisting Moments -1 Origin of Force: Heel Active Press. _ Soil over Heel = Toe Active Press. _ Soil over Toe Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe. _ Axial Load on Wall = Load @ Proj . Wall = Averaged Stem Wts. _ Added Lateral Load = Footing -Weight = Key Weight = Vert. Componant of = # ft ft-# # ft ft-# -------- 1,215 ------ 3.00 --------- 3,645 ------- ----- --------- 1,027 3.42 3,508 -15 0.33 -5 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0. 0.00 0 0 0 0.00 0 0 0.00 0 1,150 2.39 2,754 0 0.00 0 . 600 2.00 1,200 300 2.50 750 0 0..00 0 Active Press. --------- TOTALS = 1,200 ! --->> Distances from front edge of 3,640 3,077 8,212 --------- -------- --------- footing bottom (not key) L NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 F G1. 18 RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA --=---------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 600 plf Active Lateral = 30.0 psf Axial LL on Stem = 400 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in ..Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill -Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist .Passive Lateral = 250 pcf overturning @ Heel : .Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = O plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ----7-------------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft SUMMARY Pressure @ Toe = 1,45.6 psf Factors of Safety: Pressure @ Heel = 582 psf Overturning = 2.65 :1 Allowable Press. = 1,500 psf Sliding = 1.70 :1 Eccentricity = 3.43 in Resultant Within Middle Third 1 -Way Shear @ Toe = 21.1 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 1.8 psi ----------------------------- SLIDING CHECK ----------------- ------------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,125.0 # Factor of Safety = 1.70 (-)Friction = 919.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN -------------------7---------- ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 2,081 832 psf Fy = 60,000 psi Mu - Upward = 3,746 649 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 ft-# ----=--- Rebar Choices -------- Mu - Design = 3,326 332 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 21.14 1.81 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 51.2 4.1 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in a 0 NORTHSTAR ft TITLE: WEIBEL RESIDENCE ft ----- --------- ENGINEERING -------- 1,215 DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 3.42 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P(�1. I RetainPRO(tm) 2D (C)1989-92 ENERCALC --------------------------------- STEM DESIGN ---------------------------------- 0.00 0 (Factored values shown for concrete stems) Pg.2 of 2 0.00 <-------------- Stem Designs --------------> 0 Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 10.00 8.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete 0.00 0 Thickness (nominal) = 6.00 6.00 10.00 in Rebar Size = # 5 # 5 # 5 Rebar Spacing = 24.00 24.00 24.00 in Rebar Placed at Edge Edge Edge 0.00 DESIGNDATA .... ........................................_.. ............ fb/Fb + fa/Fa = 0.000 0.000 0.779 1,200 Lateral Load @ Ht. = 0 0 1,632 # MOMENT..... Allowable = 2,793 2,793 5,583 ft-# Actual = 0 0 4,352 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 psi Actual 0.00 0.00 13.90 psi Embedment Length Req'd = 12.00 12.00 8.14 Wall Weight = 75.0 75.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 in MASONRYDATA............................................................. f1m = psi Fs = Psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA............................................................ f'c = 2,500 2,500 2,500 psi Fy =. 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments -I- Resisting Moments -1 Origin of Force: Heel Active Press. _ Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe = Axial Load on Wall = Load @ Proj. Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = # ft ft-# # ------- ft ----- --------- ft-# -------- 1,215 ------ 3.00 --------- 3,645 1,027 3.42 3,508. -15 .0.33 -5 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 600 2.42 1,450 0 0.00 0 1,150 2.39 2,754 0 0.00 0 600 2.00 1,200 300 2.50 750 0 0.00 0 Active Press. --------- --------- ---- TOTALS = 1,200 3,640 3,677 9,662 --------- --------- ------------------ !--->> Distances from front edge of footing bottom (not key) 7 NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P(:� Zp RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0'psf.. Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = ,0.0 psf (horiz:vert,O=Level) Passive Lateral = 250 pcf Using Surcharge to resist overturning @ Heel : Yes Soil Density - 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in ` -------- ADJACENT FOOTING =------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil. ...dist. to. start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------ ------- Retained Height = 10.00 ft/ Toe Width = 3.00 ft% Wall Ht. above soil = 2.00 ftp; Heel Width = 2.00 ft/ ' Key Depth = 34.00 in-/ / Total Width = 5.00 12.00 ft-/ in-/ Key Width = 12.00 iri Thickness = Key Dist. to Toe = 3_.000 ft SUMMARY Pressure.@ Toe = 1,373 psf Factors of Safety: Pressure @ Heel = 170 psf Overturning = 2.07 :1 Allowable Press. = 1,500 psf Sliding = 1.56 :1 Eccentricity = 7.80 in Resultant Within Middle Third 1 -Way Shear @ Toe = 29.8 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 4.8 psi ------------ SLIDING CHECK,------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety = 1.56 (-)Friction = 964.6 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ----------------------------,-- ---Toe--- --Heel-- f'c = 2,,500 psi ACI 9.1 Pressure = 1,923 238 psf Fy = 60,000 psi Mu - Upward = 7,136 251 ft-# Using SP @ Heel Yes Mu - Downward = 945 1,191 ft -# --------Rebar Choices -------- Mu - Design = 6,191 940 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 10.89 in 11.70 in vu = 29.81 4.77 psi #5 @ 16.89 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 23.97 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 32.68 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 43.03 in 46.20 in Ru = Mu/bd"2 = 95.2 11.6 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in A. s • NORTHSTAR ft TITLE: WIEBEL RESIDENCE ft-# ENGINEERING ------ 3.67 DESCR: RETAINING WALL 20 DECLARATION DRIVE .1,283 4.42 5,668 CHICO, CALIFORNIA 95926 0.33 JOB #: 5506 BY:JMR @ 11/09/95, 916-893-1600 RetainPRO(tm) 2D (C)1989-92 ENERCALC =-------------------------------- STEM DESIGN ---------------------------------- 0 (Factored values shown for concrete stems) 0 0.00 Pg 2 of 2 0 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > -------------------------.---------------------------------------------- DESIGN HT. ABOVE FTG. = 12.00 10.00 2.00 . 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete Concrete Concrete 0 Thickness (nominal) = 6.00 6.00 10.00 10.00 in Rebar Size = # 5 # 5 # 5 # 5 1,400 Rebar Spacing = 12.00 12.00 12.00 :12.00 in Rebar Placed at Edge Edge Edge Edge DESIGN DATA ..................... ............. fb/Fb + fa/Fa = 0.000 0.000 '0.399 0.779 Lateral Load @ Ht. _ 0 0 1,632 '2,550 # MOMENT..... Allowable = 5,331 5,331 10,911 10,911 ft-# Actual = 0 0 4,352 8,500 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 85.00. psi Actual = 0.00 0.00 13.90 22.53 psi Embedment Length Req'd = 12.00 12.00 12.00 8.09 Wall Weight = 75.0 75.0 125.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 8.19 in MASONRYDATA............................................................. f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETEDATA............................................................. f'c = 2,500 2,500 2,500 2,500 psi Fy = 60,000 60,000 60;000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments .-I- Resisting Moments .-I Origin of Force: Heel Active Press. _ Soil over Heel = Toe Active Press. _ Soil over Toe = Sloped.Soil @ Heel = Adjacent Ftg. Load = Surcharge @ Heel = Surcharge @ Toe = Axial Load on Wall = Load @ Proj . Wall = Averaged Stem Wts. _ Added Lateral Load = Footing Weight = Key Weight = Vert. Componant of = ## ft ft-# # ft --------- ft-# -------- 1,815 ------ 3.67 --------- 6,655 ------- ----- .1,283 4.42 5,668 -15 0.33 -5 - 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0 0.00 0 0 0.00 0 1,400 3.40 4,758 no � 0 750 2.50 1,875 425 3.50 1,487 0 0.00 0 Active Press. --------- --------- TOTALS = 1,800 6,650 3,858 13,789 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 ZZ RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- 0.0 plf Allowable Bearing = 1,500 psf Active Lateral = 30.0 psf .....Slope Active = 0.0 psf .....Max. Active = 0 psf Backfill Slope = 0.0:1 ft (horiz:vert,O=Level) above soil = 2.00 Passive Lateral = 250 pcf Soil Density = 110.0 pcf Soil Ht over Toe = 0.0 in ------ ADDED LATERAL LOADS ------- ...Ecc. (Toe side +) Lateral Load Acting On Stem Above Soil = 0.00 psf Add'1 Lateral Load = 0.0 plf ...dist. to start = 0.00 ft ...dist. to end = 0.00 ft ---------------------------- Surcharge over Toe WALL Retained Height = 10.00 ft Wall Ht. above soil = 2.00 ft ------ ADDED VERTICAL LOADS ------ in Axial DL on Stem = 600 plf Axial LL on Stem = 400 plf ...Ecc. (Toe side +) = 0.00 in Surcharge over Toe = 0.0 psf Surcharge.over Heel = 0.0 psf Using Surcharge to resist psi overturning @ Heel Yes 630 @ Toe Yes psf -------- ADJACENT FOOTING -------- Vertical load = 0 plf ...Ecc. (Toe side +) = 0.00 in Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Ftg. Base-Above/Below Soil 3.93 At Wall Face [+/-] _ .0.00 ft Footing Type Line Third & FOOTING DATA =------------------------ Toe Width = 3.00 ft Heel Width = 2.00 ft Key Depth = 34.00 in Total Width = 5.00 ft Key Width = 12.00 in Thickness. = 12.00 in Key Dist. to .Toe = 3.000 ft = 60,000 psi SUMMARY 7,698 630 Pressure @ Toe = 1,353 psf Factors of Safety: Yes Pressure @ Heel = 590 psf Overturning = 2.38 :1 -------- Allowable Press. = 1,500 psf Sliding = 1.64 :1 6;753 Eccentricity = 3.93 in -- Toe -- Resultant Within Middle Third One-Way Shear: 1 -Way Shear @ Toe = 33.0 psi Allowable Shear = 85.00 psi in 1 -Way Shear @ Heel = 2.9 psi psi #5 @ ----------------------------- in SLIDING CHECK ------------------------------ vn=2(f'c)1/2*.85= 85.00 Ftg/Soil Friction = 0.250 #6 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety = 1.64 29.90 (-)Friction = 1,114.6 # Depth to steel = 8.50 9.50 Add'1 Force Req'd = 0 # ---------------------------- FOOTING 46.20 DESIGN ------------------------------ Ru = Mu/bd"2 = 103.8 --- Toe--- --Heel-- fic = 2,500 psi ACI 9.1 Pressure = 1,928 841 psf Fy = 60,000 psi Mu - Upward = 7,698 630 ft-# Using SP @ Heel Yes Mu - Downward = 945 1,191 ft-# -------- Rebar Choices -------- Mu - Design = 6;753 561 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 9.97 in 11.70 in vu = 33.00 2.86 psi #5 @ 15.45 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 21.92 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 29.90 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 39.36 in 46.20 in Ru = Mu/bd"2 = 103.8 6.9 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in !--->> Distances from front edge of footing bottom (not key) NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 ? 237� Z� RetainPRO (tm) 2D (C) 1989-92 ENERCALC . -------------------- ------ STEM DESIGN ---------------------------------- (Factored values shown for concrete stems) Pg 2 of 2 <-------------- Stem Designs --------------> Stem Construction Data < At Various Heights Above Ftg. > ----------------------------------------------------------------------- DESIGN HT. ABOVE FTG. = 12.00 10.00 2.00 0.00 ft WALL TYPE ABOVE HT. :Concrete Concrete. Concrete Concrete Thickness (nominal) = 6.00 6.00 10.00 10.00 in Rebar Size = # 5 # .5 # 5 # 5 Rebar Spacing = 12.00 12.00 12..00 12.00 in Rebar Placed at Edge Edge Edge Edge DESIGNDATA.............................................................. fb/Fb + fa/Fa = 0.000 0.000 .0.399 0.779 Lateral Load @ Ht. = 0 0 1,632 2,550 # MOMENT..... Allowable = 5,331 5,331 10,911 10,911 ft-# Actual = 0 0 4,352 8,500 ft-# SHEAR...... Allowable = 85.00 85.00 85.00 85.00. psi Actual = 0.00 0.00 13.90 22.53 psi Embedment Length Req'd 12.00 12.00 12.00 8.09 Wall Weight = 75.0 75.0 125.0 125.0 psf Rebar Depth = 4.19 4.19 8.19 8.19 in MASONRY DATA............................................................. f'm = psi Fs = psi Grouting Special Inspection n : Es / Em = Short Term Increase = CONCRETE DATA............................................................. f'c = 2,500 2,500 2,500 2,500 psi Fy = 60,000 60,000 60,000 60,000 psi ------------------------- SUMMARY OF FORCES & MOMENTS ---------------------- I- Overturning Moments Resisting Moments -� Origin of Force: # ft ft-# # ft ------ --------- ft-# ---------------- -------- Heel Active Press. = ------ 1,815 3.67 --------- 6,655 ------- Soil over Heel _ 1,283 4.42 5,668 Toe Active Press. _ -15 0.33 -5 Soil over Toe = 0 0.00 0 Sloped Soil @ Heel = 0 0.00 0 Adjacent Ftg. Load = 0 0.00 0 0 0.00 0 Surcharge @ Heel = 0 0.00 0 Surcharge @ Toe = 0 0.00 0 0 0.00 0 Axial Load on Wall = 0 600 3.42 2,050 Load @ Proj. Wall = 0 0.00 0 Averaged Stem Wts. = 1;400 3.40 4,758 Added Lateral Load = 0 0.00 0 Footing Weight = 750 2.50 1,875 Key Weight = 425 3.50 1,487 Vert. Componant of = 0 0.00 0 Active Press.. --------- --------- -------- --------- TOTALS = 1,800 61650 4,458 15,839 !--->> Distances from front edge of footing bottom (not key) NORTHSTAR ENGINEERING 20'Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT I��E�iI�FiL� JI D�iNGC'i JOB NO. '556 LOCATION LO 1 Irl ALM P2LUFFS D2. DATE CODES: Uniform Building Code, 1991 Edition , - AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: Concrete: f'c = 2500 psi @,28 Days Masonry: f'm = 1500 psi Mortar: f'c = 1800 psi, Type "S" Grout: f'c­ 2500 psi @ 28 days _ Steel Reinforcing: A-615 Grade 40 for #4 and /\ A-615 Grade 60 for #5 and Structural Steel: ASTM A-36 Steel Pipe ASTM A53 Grade. B Steel Tubing: ASTM A500 Grade A or B 1'';`1Machine Bolts, Anchor Bolts: ASTM A307 Grade �((9 'Wood Connectors: Simpson Strong -Tie or equal. Wood: Light Framing: Const Grade Douglas Struct .Lt Framing: #2 Grade D.F. Joists & Planks: #2 Grade D.F. Beams & Stringers:. #1 Grade D.F. �Posts & Timbers. #1 Grade D.F. smaller larger 0 Fir - Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Std 25-9 Glue -Lam Timber: ANSI/AITC A190.1-1983 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: psf Floor -Live Load: psf Seismic Zone : Wind Speed: mph Exposure: — Method 2 used unless otherwise noted. Allowable Soil Bearing (psf) IMOD ARE SPECIAL INSPECTIONS REQUIRED ? Ido GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of 2 0 i BY: JJ`1� NorthStar DATE. II/�� _ 20 DECLARATION DRIVE JOB NO: ENGINEERING CHICO, CALIFORNIA 95926 Lj C>� PAGE 2 of Civil Engineers • Planners • Surveyors 916-893-1600 9 Y w,- D T P- I` -I I O r DOI,.I, Lc:2 R F D. r DTA I N IN Ca ALL Hiz K-�Y �Llf�'IIN�Tr, F- H 7 GAPAG IT 1' of/�" P5-22AP, >3, �U AS AL-I-o�JAaL-t-�, HF,AF� _ . 31 (24) = 7,4- K U ic, -1"A L,5-- 2 E� -�2H �A F- _ 2 7- e7 _e 2. d I Dot J D0Wr,- L U L FDR I' 5 GP.TR = o'!., ►,.J A ��I HT PA GIN �LID�NG Do�,�JI,� S P1A . FO G5-- FE -7-9 FooT 10' CLG���� TIONS oNol�Lo:IJli\l FAc��� BY: —i H?— DATE: III -r5, JOB NO: Cj-"7-069 PAGE 3 OF NorthStar ENGINEERING Civil Engineers o Planners *Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 F,T? 5—, TA r J I t,,] r -q l,J A K-�Y PFPT[i Tc> Ilo 'P A FA C, I T O'K- z v 1 0 L'i -2 c, A F;oP, iol H I (fH I -J A L, L- LAT. F -1.2K LATE, -PAL (Ml�J..) O. f I of �I FO(Z 1.2 H ICS H AL L—" F-- I. g F = -77 I. I K- j OF: WALL Fog- - K -5Y AL - 4 L, V I IJ c3l 0lj � L,,5 i F'A C, I �J C—q (M�X.i F 0 b—, C- FF, lz FOOT I Fap�,J) O.'C2 BY: -I M F`, DATE: 111 I JOB NO: 26�;O PAGE 4 OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 4-2 SG H EiDULE BGLoI.J 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-693-1600 12 Folz K Y D e -PT H= o I O FLAN �/I o� i=oOTIJG N TS Do 1,J15 -:-L :�,G H L. L,JAL�L H E I Ci H T r'IAX,- DO"e-L_ (Z ROk) sPAc-,INc9 Fob KAY DEPTH =oil -W--2- W5HEIGHT SPAGIiJG FOR KaY DEPTH =ILII g� -2i- O II o. G, tJo. DOI,.I�LS IpI II_�II o,� 2,1_�II o,G, 11Q 1,11 r -,T Z Z M Pt;o N .CIIz FIQLAL, 14 MIN. ralI'EXTt it Giol INTO 2. �xPo ,:�2�� �.oGK �HoLL o PaUI� . �j d E NORTHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WIEBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 PG .� RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------• ------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN I Pg 1 of 2 -------------------------------------------------------------------------------- --=------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL.on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in ......Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe 'Yes Soil Ht over Toe = 0.0 in --------ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ..Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0-.00 ft Ftg. CL to Wall_ = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line -------------=--------------- WALL & FOOTING DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil 2.00 ft Heel Width = 1.50 ft Key Depth - 14.00 in Total Width = 3.00 ft Key Width - 12.00 in Thickness = 12.00 in. Key Dist. to Toe = 1.500 ft SUMMARY Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. = 1,500 psf Sliding = 1.50 :1 Eccentricity = .4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ------------=---------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factory of Safety = 1.50 (-)Friction = 491.2.# Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------ ------ --- Toe--- --Heel-- f1c 2,500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One -Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 .psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00;; 48.00 in NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE «.. CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 �� ,� ------------- ------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 ----------------------------7--------------------------------------------------- ----------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem. = 0 plf ....,.Slope Active = 0..0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = . 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes. Soil Density = 110.0 pcf @ Toe Yes Soil'Ht over Toe = 0.0 in -------- ADJACENT FOOTING ------ -----= ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0:00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft. SUMMARY Pressure @ Toe = 1,362 psf Factors of Safety: Pressure @ Heel = 176 psf Overturning = 2.26 :1 Allowable Press. = 1,500 psf Sliding = 1.58 :1. Eccentricity = 6.17 in Resultant Within Middle Third 1 -Way Shear @ Toe = 18.1 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 3.7 psi ----------------------------- SLIDING CHECK ------------- ----------------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in .(-)Passive Pressure = 1,125.04 Factor of Safety = 1.58 (-)Friction = 769.2.# Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,907 247 psf Fy = 60,000 psi Mu - Upward = 3,261 278 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 ft-# -------- Rebar Choices -------- Mu - Design = 2,841 704 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 18.10 3.68 psi #5 @ 20.26 in 18..13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = .43.7 8.7 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in T`• NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 9592A JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 P�=-1 7 ------------- ------------------------------------------------------ RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral =. 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope =. 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level:) Using Surcharge to resist Passive Lateral =. 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -----=-= ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf. Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft -Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start- = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ----------------------:-- Retained Height = 10.00 ft Toe Width = 3.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 34.00 in Total Width = 5.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe =: 3.000 ft SUMMARY Pressure @ Toe = 1,373 psf Factors of Safety: Pressure @ Heel = 170 psf Overturning = 2.07 :1 Allowable Press. = 1,500 psf Sliding = 1.56 :1 Eccentricity = 7.80 in Resultant Within Middle Third 1 -Way Shear @ Toe = 29.8 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 4.8 psi ----------------------------- SLIDING CHECK--------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety = 1.56 (-)Friction = 964.6 # Add'1 Force Req'd = 0 # ---=------------------------ FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c _ 2,500 psi ACI 9.1 Pressure = 1,923 238 psf Fy = 60,000 psi Mu - Upward = 7,136 251 ft-# Using SP @ Heel Yes Mu - Downward = 945 1,191 ft-# -------- Rebar Choices -------- Mu - Design = 6,191 940 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 10.89 in 11.70 in vu = 29.81 4.77 psi #5 @ 16.89 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 23.97 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 32.68 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 43.03 in 46.20 in Ru = Mu/bd"2 = 95.2 11.6 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in 1�� NORTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-1600 8 RetainPRO(tm) 2D (C)1989-92 ENERCALC -----------7------------------------------7------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 ----------------------------------------------------- ---------- SOIL DATA ------------- --------------------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = O plf Active Lateral = 30.0 psf Axial LL on Stem = .0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------.- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral -Load Acting ...Ecc. (Toe side +) = 0..00 in On Stem Above Soil = O.00.psf Footing Width (perp) = 0.010 ft Ftg. CL to Wall _ 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING'DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = .2.00 ft Heel Width = 1.50 ft Key Depth = 14.00 in Total Width = 3.00 ft Key Width = 12.00 in Thi.ckness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY ---------------------------- Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. = 1,500 psf: Sliding = 1.50 :1 Eccentricity = 4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi =---------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factor of Safety = 1.50 (-)Friction = 491.2 # Add'1 Force Req'd = 0.# ---------------------------- FOOTING DESIGN ------------------------------ ---Toe --- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu.- Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in r #7 @ 39.22 in 35.09 in. Depth to steel = 8.50 9.50 in #8 @ 48.00 in. 46.20..in Ru = Mu/bd-2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR TITLE: WEIBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/27/95 916-893-1600-- P�. 1 RetainPRO (tm) 2D (C) 1989.-92' ENERCALC ------------ - ---------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf. Axial LL on Stem =. 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1. Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf, overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = O.plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf- Ftg. Base Above/Below Soil .:.dist. to start = 0.00 ft At Wall Face (+/-] = O.00 ft ...dist. to end = 0.00 ft Footing Type. Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 8.00 ft Toe Width 2.00:ft Wall Ht: above soil = 2.00 ft Heel Width = 2..00 ft Key Depth = 16.00 in Total Width = 4.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft SUMMARY Pressure @ Toe = 1,356 psf- Factors of Safety: Pressure @ Heel = 132 psf Overturning = 2.19 :1 Allowable Press. = 1,500 psf Sliding = 1.19 :1 Eccentricity = 6.58 in Resultant Within Middle Third 1 -Way Shear @ Toe = 17.9 psi Allowable Shear = 8.5.00 psi 1. -Way Shear @ Heel = 3.9 psi ------ -------------------- --- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 680.6.# Factor of Safety = 1.19 .(-)Friction = 744.2.# Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c 12,500 psi ACI 9.1 Pressure = 1,898 185 psf Fy = 60,000 psi Mu - Upward = 3,226 239 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 ft-# -------- Rebar Choices -------- Mu - Design = 2,806 742 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = .17.88 3.87 psi #5 @ 20.26 in 18:13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 43.1 9.1 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.0.0 in 48.00 in NOKTHSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 JOB ##: 5506 BY:JMR @ 11/27/95 916-893-1600 14-�> RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------------------------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN. Pg 1 of 2 --------------------------------------------------------------------------------- ---------- .SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = O.O.psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral 250 pcf overturning @ Heel.: Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = O.00 in On Stem Above Soil = 0.00 psf Footing.Width (perp) = 0.00 ft Ftg. CL to Wall _ 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At -Wall Face [+/-] _ .0.00 ft ...dist. to end = 0.00 ft Footing Type Line ----------------------=----- WALL & FOOTING DATA ------------------------- Retained Height 10.00 ft Toe Width = 2.33 ft Wall Ht. above soil = 2.00 ft Heel Width = 4.00 ft Key Depth - 16.00 in Total Width _ 6.33 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe 2.250 ft SUMMARY Pressure @ Toe = 1,228 psf Factors of Safety: Pressure @ Heel = 678 psf Overturning = 3.60 :1 Allowable Press. = 1,500 psf Sliding = 1.22 :1 Eccentricity = 3.65 in Resultant Within Middle Third 1 -Way Shear @ Toe = 22.4 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 13.7 psi ----------------------------- SLIDING CHECK=------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 680.6 # Factor of Safety = 1.22 (-)Friction = 1,508.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,719 950 psf Fy = 60,000 psi Mu - Upward = 4,409 5,405 ft-# Using SP @ Heel Yes Mu - Downward = 570 8,774 ft-# -------- Rebar Choices -------- Mu - Design = 3,839 3,369 ft-# -- Toe -- -- Heel - One -Way Shear: #4 @ 13.07 in 11.70 in vu = 22.42 13.67 psi .45 @ 20.26 in 18.13 in vn=2 (f' c) 1/.2* . 85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 59.0 41.5 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in a BY: DATE: I qrj JOB NO: 151500 PAGE II OF ,NO '-�;GAL_E NwthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-.1600 F_-- ` 0 Wc-TIoN ,Jo1NT�� L, �l , Fo R PLANS P5 --R- Pte. 4- SST LI Q W1Ho . . FOIZ APP IT loll AL. _INFO t ALL., Foo,Tl NORTHSTAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT LJ IiI F2Fi L, V- 12 �'i N G E, JOB NO. LOCATION L-62-1. 1-`2 Al,M P2I_UFF 2 DP-. DATE 1 1 - 20-19 CODES: Uniform Building Code,. 1991 Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: Concrete: f'c = 2500 psi @ 28 Days Masonry: f'm = 1500 psi Mortar: f'c ='1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days -- Steel Reinforcing: A-615 Grade 40 for #4 and A-.615 Grade 60 for #5 and i!" .�� =\��• Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B Steel Tubing ASTM A50'0 Grade A or B 'Machine Bolts, Anchor Bolts: ASTM A307 Grade A ;;Wood Connectors: Simpson Strong -Tie or equal. smaller larger 1 -'Wood• Light Framing: Const Grade Douglas Fir Struct Lt Framing: #2 Grade D.F. Joists & Planks: #2 Grade D.F. Beams & Stringers: #1 Grade D.F. Posts & Timbers: #1 Grade D.F. Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Glue -Lam Timber: ANSI/AITC A190.1-1983 LOADS: Roof Live Load: Seismic Zone Exposure: — Allowable Soil Std 25-9 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination Method Bearing psf Floor Live Load: Wind Speed: 2 used unless otherwise (psf) I f5oo ARE SPECIAL INSPECTIONS REQUIRED•? C, psf mph noted. GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. -Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of BY: J M F— DATE: jj/clGJ JOB NO: 54;0 & PAGE Z OF NorthStar ENGINEERING Civil Engineers * Planners *Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 <:::2 5-7-A IN INCA (�,-APAC,iVr OF 2q - As A kJ Aa L. E-:, � H aA F- .31 CZ4) = 7,4 K. F-O;Z c5lg A Rl - �lj PSI F UG 7"A 1,5-- A L- c5l-J L, � �H �A P- = 2 -7 -KlScnLT 12, EL A 1C5j H T aLl 4;_7 SPA SIN HAX.) r., F5 --g Food" 7' K iz, 0'. C.,. C4L.GLlL�ATIO\1S oN Fol L,0 1,J I 1J C�., BY: -1 M F, DATE: I I! 9 JOB NO: PAGE OF NwthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 Sc,H�Du� • • m ♦ iso '`rl.. �;; N TS P I. Dol„1���� SNDA 3L 8>✓. I������A� D � �o Dg�l DI 14��GH SI PAPI D TT�'2�►�l TN E 2. E�xPosC-,7 , p - r -2L F;l� � � >✓,� N � I.`J �T P<? I off. To PaU � . S. - I�JAI.I, HT� C r-AxI�lL - SPAGI 0. C, o. Cl P I. Dol„1���� SNDA 3L 8>✓. I������A� D � �o Dg�l DI 14��GH SI PAPI D TT�'2�►�l TN E 2. E�xPosC-,7 , p - r -2L F;l� � � >✓,� N � I.`J �T P<? I off. To PaU � . S. - NOATHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WIEBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09./95 916-893-1600 PG ¢ RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------- -------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf. Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL.on Stem = .0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel : Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in --------ADJACENT FOOTING --------- ' -----°- ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'.1 Lateral Load = 0.0 plf Ftg. Base Above/Below-Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth = 14.00 in Total Width = 3.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :.1 Allowable Press. = 1,500 psf Sliding = 1.50 :1 Eccentricity = 4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ---------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 586.8 # Factor of Safety = 1.50 (-)Friction = 491.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------- =---------- --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18..13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.2.2 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 20.4 2.2 #9 .@ 48.00 in 48.00 in Mina Rebar Ratio = 0.0018 #10 @ 48.OQ ,p v. 48.00 in NORTHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WEIBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 ------------- ------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING ------- ------ ADDED LATERAL LOADS ------- Vertical load= 0 plf .. Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in. On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below. Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.00 ft, Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft SUMMARY Pressure @ Toe = 1,362 psf Factors of Safety: Pressure @ Heel = 176 psf Overturning = 2.26 :1 Allowable Press. = 1,500 psf Sliding = 1.58 :1 Eccentricity = 6.17 in Resultant Within Middle Third 1 -Way Shear @ Toe = 18.1 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel --------------- = 3.7 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,125.0 # Factor,.of Safety = 1.58 (-)Friction = 769.2 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c = 2,500 psi ACI 9.1 Pressure = 1,907 247 psf Fy = 60,000 psi Mu - Upward = 3,261 278 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 ft-# -------- Rebar Choices -------- Mu - Design = 2,841 704 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 18.10 3.68 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00.psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd^2 = 43.7 8.7 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WIEBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 9592ti JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 PG 6O dF ------------- ------------------------------------------------------ RetainPRO(tm) 2D (C)1989=92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral =. 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) _ 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope =. 0.0:1 Surcharge over. Heel = 0.0 psf (horiz:vert,O=Level:) Using Surcharge to resist Passive Lateral =, 250 pcf overturning @ Heel.: Yes Soil Density = 110.0 pcf @ Toe; Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ....Ecc. (Toe side +) = 0.00 in On Stem Above Soil. = 0.00 psf Footing Width (perp) = . 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end _ 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA ------------------------- Retained Height = 10.00 ft Toe Width = 3.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 34.00 in Total Width = 5.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe =: 3.000 ft SUMMARY Pressure @ Toe = 1,373 psf Factors of Safety: Pressure @ Heel = 170 psf Overturning = 2.07 :1 Allowable Press. = 1,500 psf Sliding = 1.56 :1 Eccentricity = 7.80 in Resultant Within Middle Third 1 -way Shear @ Toe = 29.8 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 4.8 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @.Toe Not Used. = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety = 1.56 (-)Friction = 964.6 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe--- --Heel-- f'c 2,500 psi ACI 9.1 Pressure = 1,923 238 psf Fy = 60,000 psi Mu - Upward = 7,136 251 ft-# Using SP @ Heel Yes Mu - Downward = 945 1,191 ft-# -------- Rebar Choices -------- Mu - Design = 6,191 940 ft-# -- Toe -- -- Heel -- One-Way.Shear: #4 @ 10.89 in 11.70 in vu = 29.81 4.77 psi #5 @ 16.89 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 23.97 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 .@ 32.68 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 43.03 in 46.20 in Ru = Mu/bd"2 = 95.2 11.6 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTH STAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT l� �� L ��S D�iI�K JOB NO. LOCATION LOT E-2 AL -r-1 aL,LJFFA 2(,•GI4I G0 . DATE I I —22- 19 CODES: Uniform Building Code, 1991 Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: 3r a C 053590 E T CIVIL ,tiQ °F CALL`°4� Concrete: f'c = 2500 psi @ 28 Days , Masonry: f'm = 1500 psi Mortar: f'.c = 1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days Steel Reinforcing: A-615 Grade 40 for #4 and smaller A-615 Grade 60 for#5 and larger Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B Steel Tubing: ASTM A500 Grade A or B` achine Bolts, Anchor Bolts: ASTM A307 Grade A Wood Connectors: Simpson Strong -Tie or equal. Wood: Light Framing: Const GradeDouglas Fir Struct Lt Framing: #2 Grade D.F. Joists & Planks: #2 Grade D.F. Beams & Stringers: #1 Grade D.F. Posts & Timbers: #1 Grade D.F. Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Std 25-9 Glue -Lam Timber: ANSI/AITC-A190.1-1983 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: Seismic Zone Exposure: Allowable Soil Method Bearing psf Floor Live Load: .Wind Speed: 2 used unless otherwise (psf) 1,500 ARE SPECIAL INSPECTIONS REQUIRED ? psf mph noted. GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of ?j BY: -Jt'I�L DATE: II PS JOB NO: PAGE: OF A T �1 NorthStar 20 Declaration Drive Engineering Chico, CA 95926 Civil Engineers - P12nners - Surveyors (916) 893-1600 61 a RETAINING WALL 712 72-AliQ P- -,::2 iJ —2 UNTIL Z Zo PAYS tIlQi. DAYS. _Ag -T loll loll RETAINING WALL 712 72-AliQ P- -,::2 iJ —2 UNTIL Z Zo PAYS tIlQi. DAYS. _Ag A .0 BY: .J DATE: -JOB NO: PAGE: OF IL lzc-_v 11122IC ra it E:'.0. _CkZ3 ( Ole. NorthStar Engineering Civil Engineers - Planners - Surveyors r - 20 Declaration Drive Chico, CA 95926 (916) 893-1600 I,Z— ji IIJID5� b jZ_ p- 0. RETAINING WALL 1--, 1-4 fz IQ AT 1 1015 F I L, (D ------ - RETAINING WALL 1--, 1-4 fz IQ AT 1 1015 F I L, (D NORTHSTAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 REVISED STRUCTURAL CALCULATIONS PROJECT I'i ��L R -CS D�I� JOB NO. LOCATION LOT r� A LL tJ 5L U FFA D(Z . QA I GD DATE I I -Z Z - �9, CODES: Uniform Building Code, 1991.Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: 4?0 i• ESS_r0Ar� C 0535 0 y Esp. Gl Concrete: f'c = 2500 psi @.28 Days Masonry: f'm 1500 psi Mortar: f'.c = 1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days': Steel Reinforcing: A-615 Grade 40 for #4 and smaller A-615 Grade 60 for #5 and larger Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B Steel Tubing: ASTM A500 Grade A or B Machine Bolts, Anchor Bolts: ASTM A307 Grade A Wood Connectors: Simpson Strong -Tie or equal. Wood: Light Framing: Const Grade Douglas Fir Struct Lt Framing: #2 Grade D.P. Joists & Planks: #2 Grade D.F. Beams & Stringers:. #1 Grade D.F. Posts & Timbers: #1 Grade D.F. Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Std 25-9 Glue -Lam Timber: ANSI/AITC A190-.1-1983 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: psf Floor Live Load: psf Seismic Zone Wind Speed: mph Exposure: Method 2 -used unless otherwise noted. Allowable Soil Bearing (psf) 1500 ARE SPECIAL INSPECTIONS REQUIRED ? GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of BY:` , -1 PL DATE: II MS JOB NO: C-;r;2D�p PAGE: 2 OF 0 VfjV Wz- /c� 'i`• r�/ G� '1 jCL Cc> Exp. Co/ \ v� NorthStar Engineering Civil Engineers • Planners • Surveyors 02 1N R0GK. 20 Declaration Drive Chico, CA 95926 (916) 893-1600 ILIA ►,Jlpc � 2 _ �G �oN� 5%A t✓ -- — L �O =I G�� r1L� SII O G ,1.7 e 0r- GOTOP P30TTOt-j JN�iG; URS% T= �oNTIr1Uo� I. P!_AG�— UNTIL 20 PAYS NII 2 a DAYS. 2-. � Lam^r' : "17 RETAINING WALL T G� ALLG� I'�I 8'-O II � '- o" 4•- 011 A / ii I I_dli all 14,11 I I .�j Y_ loll loll GOTOP P30TTOt-j JN�iG; URS% T= �oNTIr1Uo� I. P!_AG�— UNTIL 20 PAYS NII 2 a DAYS. 2-. � Lam^r' : "17 RETAINING WALL T G� ALLG� BY: � M DATE: 1! -JOB NO: PAGE: :5 OF &S V_ ew I I I'z Z rN Typ_ IS 6 0 Ex.o. NorthStar Engineering Civil Engineers - Planners - Surveyors 20 Declaration Drive Chico, CA 95926 (916) 893-1600 Z) z II 11 0. Ai - Ii,I IS 6 0 Ex.o. NorthStar Engineering Civil Engineers - Planners - Surveyors 20 Declaration Drive Chico, CA 95926 (916) 893-1600 Z) z II 11 0. Ai - RETAINING WALL 7L -2F `57 I TO F Z-1 (:2�'j UNTIL ZO PAYS NVl 2. C-0 1Jr' P_ r-, T r,- Z Sx::50 P5, I � ZO DAYS 'Z - 11_ -ail C5!. lollIOII RETAINING WALL 7L -2F `57 I TO F Z-1 (:2�'j UNTIL ZO PAYS NVl 2. C-0 1Jr' P_ r-, T r,- Z Sx::50 P5, I � ZO DAYS 'Z - NORTHSTAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 89.3-2113 REVISED STRUCTURAL CALCULATIONS PROJECT V�►C�iIC/�i� �Ci�JI iJG�i JOB NO. '55o6 LOCATION 1,0 I (2 /-\L" P2I._UFF2 22. DATE ( _ 20 CODES: Uniform Building Code, 1991 Edition AISC, Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC, Timber Construction Manual MATERIALS: Concrete: f'c = 2500 psi @ 28 Days Masonry: f'm = 1500 psi Mortar: f'c = 1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days Steel Reinforcing:. A-615 Grade 40 for #4 and smaller' A-615 Grade 60 for #5 and larger Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B Steel Tubing ASTM A500 Grade A or B 1,1'�Machine Bolts, Anchor Bolts: ASTM A307 Grade jWood Connectors: Simpson Strong -Tie or.equal. 71 J I I'°Wood: Light Framing: Const Grade Douglas Struct Lt Framing: #2 Grade D.F. 0 Fir Joists & Planks: #2 Grade D.F. Beams & Stringers: #1 Grade D.F. Posts & Timbers: #1 Grade D.F. Plywood: A.P.A. Rated Sheathing, Grade CD, UBC Std 25-9 Glue -Lam Timber: ANSI/AITC A190.1-1983 Simple Spans: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS: Roof Live Load: psf Floor Live Load: psf Seismic Zone : Wind Speed: mph Exposure: — Method 2 used unless otherwise noted. Allowable Soil Bearing (psf) : 100 ARE SPECIAL INSPECTIONS REQUIRED ? 0 GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of 0 BY: J M W DATE: I I /clrr JOB NO: 55;0& PAGE 2 OF N.ofthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 D1 �T I �1� 0;= DoI,.1Gl,� R� D. ��TAINI►JCa �Hot�T ✓►��� C-APAG IT 'rof 2 I) A L. L. 0 k ASL, r-, H aA R = . 31 (Z4-) = 7. 4 K. PoiZ F�12 �I UOG i"'A pa, L- 5-, A A 5 �M 5-:A R- 2 -77EL �SoLT DoI.J�L �GH�DLII-� WAL-L- �-ATr-,PZAL MIN. of X01;`1 ��I HTL,ID�NG no�.�JI�� SPA HAX.) F012-c F5,9 FooT �,J--7- 8' G 7 K o 4./ 3 0. G, I2' K o. ��i I.o�o,�, ✓ PA . �7 BY: -j M IZ, DATE: I 1/ 9 67 - JOB NO: �C2067 PAGE �3 OF ea' NorthSta -7 - r ENGINEERING Civil Engineers e Planners o Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 PIAN V) � l.,J T NTS Do LJ L SG H �P 0 L- I Ci H T PCl-J5-,L, N.oT�� I. PoI,J`vL,-2 5HAL.L, a�. P-eP, 4�AINl , I P 3/4-- 11 (::P HOL,5' , F-1 P-APID '--215,T HlGH FP --10p- To POO P, NORTHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WIEBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09./95 916-89371600 PG ¢ RetainPRO(tm) 2D (C)1989-92 ENERCALC -------------- ------------------------------------------------------- CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral - = 30.0 psf. Axial LL.on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max.. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level) Using Surcharge to resist Passive Lateral = 250 pcf overturning @ Heel : Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Verti-cal load = O.plf Lateral Load Acting ...Ecc. (Toe side +) _ .0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = O.00.ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below-Soil ...dist. to start = 0.00 .ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Fooe ting Type Line ---------=------------------ WALL & FOOTING DATA ------------------------= Retained:Height = 6.00 ft Toe Width = 1.50 ft Wall Ht. above soil = 2.00 ft Heel Width = 1.50 ft Key Depth = 14.00 in Total Width = 3.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 1.500 ft SUMMARY ----------------------------- - Pressure @ Toe = 1,161 psf Factors of Safety: Pressure @ Heel = 149 psf Overturning = 2.28 :1 Allowable Press. 1,500 psf Sliding = 1.50 :1 Eccentricity = 4.64 in Resultant Within Middle Third 1 -Way Shear @ Toe = 9.5 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 0.0 psi ----------------------------- SLIDING CHECK ------------------------------ Ftg/Soil Friction = 0.250 Lateral Pressure = 720.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 5.86.8 # Factor of Safety = 1.50 (-)Friction = 491.2 # Add'1 Force Req'd = 0 # --=------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f'c = 2',500 psi ACI 9.1 Pressure = 1,626 208 psf Fy = 60,000 psi Mu - Upward = 1,563 70 ft-# Using SP @ Heel Yes Mu - Downward = 236 252 ft-# -------- Rebar Choices -------- Mu - Design = 1,327 182 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ *13.07 in 11.70 in vu = 9.54 0.00 psi #5 @ 20.26 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To.Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd"2 = 20.4 2.2 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.0Q�; p 48.00 in NORTHSTAR ENGINEERING 20 DECLARATION DRIVE TITLE: WEIBEL RESIDENCE DESCR: RETAINING WALL CHICO, CALIFORNIA 95926 JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 PG ------------- ------------------------------------------------------- RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral = .30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope = 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,0=Level) Using Surcharge to resist Passive Lateral = 250 pcf.' overturning @. Heel Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = :0 plf Lateral Load Acting ..Ecc. (Toe side +) = 0.00 in On Stem Above Soil = 0.00 psf Footing Width (perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft- Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line ---------------------------- WALL & FOOTING DATA -----------=------------- Retained Height = 8.00 ft Toe Width = 2.00 ft Wall Ht. above soil = 2.00 ft Heel Width = 2.00 ft Key Depth = 24.00 in Total Width = 4.0,0 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe = 2.000 ft SUMMARY Pressure @ Toe = 1,362 psf Factors of Safety: Pressure @ Heel = 176 psf Overturning = 2.26 :1 Allowable Press. = 1,500 psf Sliding = 1.58 :1 Eccentricity = 6.17 in Resultant Within Middle Third 1 -Way Shear @ Toe = 18.1 psi Allowable Shear = 85.00 psi 1 -Way Shear @ Heel = 3.7 psi ----------------------------- SLIDING CHECK --------------------- --------- Ftg/Soil Friction = 0.250 Lateral Pressure = 1,200.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,125.0 # Factor of Safety = 1.58 (-)Friction = 769.2 # Add'1 Force Req'd = 0,# ---------------------------- FOOTING DESIGN ------------------------------ ---Toe--- --Heel-- f1c = 2,500 psi ACI 9.1 Pressure = 1,907 247 psf Fy = 60,000 psi Mu - Upward = 3,261 278 ft-# Using SP @ Heel Yes Mu - Downward = 420 981 hoices-------- ft-# -------- Rebar Choices -------- Mu - Design = Mu 2,841 704 ft-# --.Toe -- -- Heel -- One-Way Shear: #4 @ 13.07 in 11.70 in vu = 18.10 3.68 psi #5 @ 20.26. in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 28.76 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 39.22 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 48.00 in 46.20 in Ru = Mu/bd^2 = 43.7 8.7 #9 @ 48.00 in. 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NOR'I'HSTAR TITLE: WIEBEL RESIDENCE ENGINEERING DESCR: RETAINING WALL 20 DECLARATION DRIVE CHICO, CALIFORNIA 9592A JOB #: 5506 BY:JMR @ 11/09/95 916-893-1600 PG & aF: 0 ------------- ------------------------------------------------------ RetainPRO(tm) 2D (C)1989-92 ENERCALC CANTILEVERED RETAINING WALL DESIGN Pg 1 of 2 -------------------------------------------------------------------------------- ---------- SOIL DATA ------------- ------ ADDED VERTICAL LOADS ------ Allowable Bearing = 1,500 psf Axial DL on Stem = 0 plf Active Lateral =. 30.0 psf Axial LL on Stem = 0 plf .....Slope Active = 0.0 psf ...Ecc. (Toe side +) = 0.00 in .....Max. Active = 0 psf Surcharge over Toe = 0.0 psf Backfill Slope =. 0.0:1 Surcharge over Heel = 0.0 psf (horiz:vert,O=Level:) Using Surcharge to resist Passive Lateral =. 250 pcf overturning @ Heel.: Yes Soil Density = 110.0 pcf @ Toe Yes Soil Ht over Toe = 0.0 in -------- ADJACENT FOOTING -------- ------ ADDED LATERAL LOADS ------- Vertical load = 0 plf Lateral Load Acting ...Ecc. (Toe side +) = 0.00 in On Stem Above Soil _ 0.00 psf Footing Width .(perp) = 0.00 ft Ftg. CL to Wall = 0.00 ft Add'1 Lateral Load = 0.0 plf Ftg. Base Above/Below Soil ...dist. to start = 0.00 ft At Wall Face [+/-] = 0.00 ft ...dist. to end = 0.00 ft Footing Type Line -----------------------=---- WALL & FOOTING DATA ------------------------- Retained Height = 10.00 ft Toe Width = 3.00 ft Wall Ht. above soil =. 2.00 ft Heel Width = 2.00 ft Key Depth = 34.00 in Total Width = 5.00 ft Key Width = 12.00 in Thickness = 12.00 in Key Dist. to Toe =: 3.000 ft SUMMARY Pressure @ Toe = 1,373 psf Factors of Safety: Pressure @ Heel = 170 psf Overturning = 2.07 :1 Allowable Press. = 1,500 psf Sliding = 1.56 :1 Eccentricity = 7.80 in Resultant Within Middle Third 1 -Way Shear @ Toe = 29.8 psi Allowable.Shear = 85.00 psi 1 -Way Shear @ Heel = 4.8 psi ----------------------------- SLIDING CHECK Ftg/Soil Friction = 0.250 Lateral Pressure = 1,800.0 # Soil @ Toe Not Used = 0.00 in (-)Passive Pressure = 1,836.8 # Factor of Safety 1.56 (-)Friction _ 964.6 # Add'1 Force Req'd = 0 # ---------------------------- FOOTING DESIGN ------------------------------ --- Toe --- --Heel--. f'c = .2,500 psi ACI 9.1 Pressure = 1,923 238 psf Fy = 60,000 psi Mu - Upward = 7,136 251 ft-# Using SP @ Heel Yes Mu - Downward = 945 1,191 ft-# -------- Rebar Choices -------- Mu - Design = 6,191 940 ft-# -- Toe -- -- Heel -- One-Way Shear: #4 @ 10.89 in 11.70 in vu = 29.81 4.77 psi #5 @ .16.89 in 18.13 in vn=2(f'c)1/2*.85= 85.00 85.00 psi #6 @ 23.97 in 25.73 in Rebar CL To Edge = 3.50 2.50 in #7 @ 32.68 in 35.09 in Depth to steel = 8.50 9.50 in #8 @ 43.03 in 46.20 in Ru = Mu/bd"2 = 95.2 11.6 #9 @ 48.00 in 48.00 in Min. Rebar Ratio = 0.0018 #10 @ 48.00 in 48.00 in NORTHSTAR ENGINEERING 20 Declaration Drive Chico, CA 95926 (916) 893-1600 FAX (916) 893-2113 STRUCTURAL CALCULATIONS PROJECT �J G 13 F- t- S JOB NO. 550( LOCATION Lor IS $UTrC CO. DATE S ' 3I CODES: Uniform Building Code, 1991 Edition AISC,; Manual of Steel Construction, 9th Edition ACI, Manual of Concrete Practice, 1988 Edition AITC,:Timber Construction Manual MATERIALS: Concrete: f'c = 2500 psi @ 28 Days Masonry: f.'m = 1500 psi Mortar: f'c = 1800 psi, Type "S" Grout: f'c = 2500 psi @ 28 days �e Steel Reinforcing: A-615 Grade 40 for #4 and smaller, 4 �^'� A-615 Grade 60 for #5 and larger Structural Steel: ASTM A-36 Steel Pipe: ASTM A53 Grade B �$h� Steel Tubing: ASTM A500 Grade A or B Machine Bolts, Anchor Bolts: ASTM A307 Grade A Wood Connectors: Simpson Strong -Tie or equal. Wood: Light Framing: Const Grade Douglas Fir Struct Lt Framing, Joists & Planks: D.F. #2 Beams & Stringers, Posts & Timbers: D.F. #1 �C.�^�'� Plywood: A.P.A. Rated. Sheathing, Grade CD, UBC Std 25-9 R69- Er-OrGO!D-� Glue -Lam Timber: ANSI/AITC A190.1-1983 Simple Spans.: 24F -V4 Combination Cantilevers: 24F -V8 Combination LOADS': Roof Live Load: 2-v psf Floor Live Load: 4o psf Seismic Zone.: 3 Wind Speed: 8:';' mph Exposure.: G Method 2 used unless otherwise noted. Allowable Soil Bearing (psf) : 1,500 ARE SPECIAL INSPECTIONS REQUIRED -? `r6S - STM.UGTr0 ,MA. 1, STt-7-eL GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Verification of the soil conditions at the project site to determine the expansion index or bearing capacity is by others. Page 1 of 4z + A-FFAGHMr-,i 1T IIAII 4-5 PP%Lt-S BY: 1`106, DATE: 9 JOB NO: 55�� PAGE 2- OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 worsommscom F i ri l -E a L"-( 2.3 p. -3o IrISO1� 2.J I rL_ 30.0 FS t D - -- �- -. ... - - i —4, !` _ _• I?�o? F T rZ u S 5 t;,;—= S I (.i i j $-(�Hoc, N1 U FP -GT W R- t __4L"S if s BY: MA DATE: q - 2-q'� JOB NO: 55oco PAGE 3 OF NorthStar 20 DECLARATION DRIVE ENGINEERING CHICO, CALIFORNIA 95926 Civil Engineers • Planners • Surveyors 916-893-1600 . K.cS':i7:-, . ! 1 � � 1 1 1 J LL a 10, -- � s o�. --- - _I o .. Y BY: M A DATE: q - Z -q `S JOB NO: SSC�40 PAGE 4- OF NorthStar -- ENGINEERING ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 r i 0. 0,15 I 9 4 I iL S - 2.4 = -1 �;'I I r13 4-2 S P F -t �.l _- I � • S � 2.1 Z G� I'-�:. D � , r� I � , i ". s i... (�. ' ..Z. 4 (..}.._ J ,._._. �I, I_�• I L _ S 1: �, t`.� � �. �. - = 3S.—l� I rJ 3. Za i W '2, 0, 3"7-'�/� ... I • O E_ . 1 rJ SL -r (�' l O. O I, o�3 o: l �5 "A Irl_+ G eo + _I 111.5-�0.3�{�' _ 5.0 �� �S� •5.0.-;..(L•��? —;._�' °✓ ...�i3...� .�_� � �_.�-_.. � 1. i:s =.�! 45.'18x1 24F'V8 ' � 11 MIN. BY: 1 -11 - DATE: -11 - DATE: q - Z - 0I'. JOB NO: coo PAGE S OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 SZ 3}(0,033 I`:3 5(0.29 - 1 r I.q I•c ! y �r �r 1. _1_o-_ ' i I m 3 I ep, ,I. 12.3 us ✓°.i /8 x.1? Z4F -V4 1�" FT' C4 Dl - I -1 R = # = I. Z>0. 4SL- � i po- 4s -i _ 1 r.— 14• �O.Q'S� .1 -. 1 47 ..-.I�I-L �'O.Ac�o - _ .•' IG. �I .. .Gi I , � 1 V1 ��..... �'"�'..,.._�._..l{-._ _1.�._._....% .I'I' 8 � — 11•I ; S = I � — 1�3'_I I� � �--_.IZ-�I. !�—_..Ir1 ' +;_..� ..i . �14 4���,�3�� r _ (0 �'% ol t G 1j{ use C?x 12.. D.F� BY: DATE: 919C2 JOB NO: Sy Q (,j . PAGE & OF NorthStar " �. t ENGINEERING Civil Engineers • Planners • Surveyors R2E�-AH �I ; f . I C (45. f 6-ol '21 2-) 5 r r P + . D 767 (z Co�2� 8J.� 43.25 2 ►7 C �I i -2 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 � I ` f r �- I�-I'L7_ _ _► 4C� A . _= .._�-�.i2,z. - Imo= 2O. _l�Z' S= 7 q-. 6 l 2.4- —"22 Z76o I BY: J I 112, DATE: 9 /qcj JOB NO: CjC)Q(q PAGE 7 OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 �----- _ rte....-•-� cD (14 2.2 {� A= I. (2.2 . I (oma = 20 i N2 <� 4-2- 2I 7- i 1 (143)4)--2gol2jo = 47v1 4 use �2i I31�2 F -V ��AM 12 L0O,2,� 0 2)+ (O�OIi �-e (1¢1Z)1 = I-� (I.0) Ia-Z�2.4 = 12� 1�.3 ` I�2 �.�60 it. o (I�)3 a,� ��IZ4= to3ai 14C I¢41 YE5AM 11 (-o IZoOF) PP `�2 (IalI-)NaIz�.o3S=2.G14� PG..B 09-12-1995 TJ—Spec (TM) Page 1 of 1 12:36:09 v4.41 145010409 1001 TJSPECB RCE 1708 SALEM STREET CHICO, CA 95928 USA Phone: 916 894-8801 --------------------------------------------------------------------------------------------------------------------- Name: CHARLES ROBERTS Project Name: WEIBEL RES. Page Title: Based on Allowable Stress Design (ASD). UBC building code for TJM products available through Distribution (Residential) Application......... Floor - Res. Deflection Criteria ( R) Member Use ................ JOIST Load Classification....... Floor LL Defl TL Defl Member Top Slope(in/ft)... 0.000 Load Duration Factor....... 1.00 Span 1 L/480 L/240 Roof Slope(in/ft)......... 0.000 Live Load(psf)............. 40.0 loading Floor Decking.'................ G Dead Load(psf)............. 22.0 102% Repetitive Member Use......... Y loading Moment(ft-lb) 3968 Reinforced Overhangs........ N/A 14" TJI(R)/25DF JOIST @ 24..0" o/C 16'- 0.00" ------------------------------------------ S I Z E A N A L Y S I S - A S D ----------------------------------------- IMPORTANT! The analysis presented below is output from software. developed by Trus Joist MacMillan(TJM). TJM warrants the sizing of its products by this software will be accomplished in accordance with TJM product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a TJM Associate. The. maximum unbraced length(s) shown are based on the controlling compressive forces on either the top or bottom edges of the member. Lateral bracing needs to be properly attached and positioned to achieve stability. Span 1 Max. Reaction Total(lb) 992 992 Live(lb) 640 640 Required Brg. Length(in) 1.75(W) 1.75(W) Max. Unbraced Length(in) 36 Copyright (c) 1994 by Trus Joist MacMillan; a limited partnership, Boise, Idaho. TJI(R) is a registered trademark of Trus Joist MacMillan. TJ-Spec(TM) is a trademark of Trus Joist MacMillan. Maximum Design Allowable Control Shear(lb) 992 992. < 1710 172% LT. end Span 1 under Floor loading Reaction(lb) 992 992 < 1015 102% Bearing 1 under Floor loading Moment(ft-lb) 3968 3968 < 5564 140% MID Span 1 under Floor loading Live Defl.(in) 0.239 < 0.400 L/804 MID Span 1 under Floor loading Total Defl.(in) 0.370 < 0.800 L/519 MID Span.l under Floor loading Span 1 Max. Reaction Total(lb) 992 992 Live(lb) 640 640 Required Brg. Length(in) 1.75(W) 1.75(W) Max. Unbraced Length(in) 36 Copyright (c) 1994 by Trus Joist MacMillan; a limited partnership, Boise, Idaho. TJI(R) is a registered trademark of Trus Joist MacMillan. TJ-Spec(TM) is a trademark of Trus Joist MacMillan. 1 I BY: Hlt-. DATE: 9- 7-- °I S JOB NO: 550 fo PAGE 'I OF NortMtar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 00%,Ir1C-r _: _ 2.-1 Z_;+ �1�3Co = ^r.�3>�- S 2• I FT _Ll#_ i Ll �. Ste' �G' �� :! !J �- ✓ ry I _ _ , ._ TL 4�5 l -J T. N �I CANT ToT. H I C -HT .. �,o.'_ _ _... TAT SOIL .Or�i�/-� U1`1pi`((7ol�-.. _� s 20 (I.�}..- , i t i.,,.,, ._..,�. �_.....y _.... ._ _ . •---- _ _. ....--- --..�......,_ `.,_ _fes. .�.---�-- - .} __.,......1......j.�.� I ! ' BY: HA DATE: 9 - Z-9 JOB NO: 550 PAGE IO OF 113- (): (Zo, L, oGF. 1 or-) s I ,I _0 �`f^N E S L Lo i.,J I ►-a L1 L i N E S Co M P L`f B( I�SPEGTIotiI `'( I<IILL JOT- f.E I�1�12,4�5 NorthStar 20 DECLARATION DRIVE ENGINEERING CHICO, CALIFORNIA 95926 916-893-1600 Civil Engineers • Planners • Surveyors 1° . I � / I .9 J a !2DATBY: I M,2- DATE: E: JOB NO: PAGE II OF NwthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO,-CALIFORNIA 95926 916-893-1600 s BY: J I I DATE: JOB NO: PAGE I Z OF j- , NorthStar ENGINEERING Civil Engineers • Planners • Surveyors R 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 �._-�, . • ;._) G./� r l.' �- Q � lei, � •i. _ (� "_ j"7`�}� y�•_�,. ,„.I t �.,�� . _ � ... � __.._. � �_ -._ � .., .�_..�_.....� -� oT�l • 27Z (I� HP S ! _k . �.. HP IL, 2 A'. .-i, 21.:7[4� X: - R L,INt7-1 G t `i• -I D, -- 2 GSR I ._ r%'� ._ 2 �Z _#- _ V 0 BY: J I I p— DATE: JOB NO: �✓�� PAGE 2> OF NwthStar ..rte ....... r"� ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 BY: J DATE: Cl 1 CK5 JOB NO: e54—v O PAGE I4OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 SIN H1- 11 t2L 22 _ 7 1 <�aITli�IL� i i OT -1 = 274 (3_ � �� 1 � - i DJ K� _ SIN H1- 11 t2L 22 _ 7 1 BY: J I " I �-• DATE: JOB NO: 45i�20(O PAGE IG] OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 4 t. BY: J r121— DATE: 1ZDATE: JOB NO: PAGE 16/ OF NorthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 1. BY: -i DATE: JOB NO: G�Q� PAGE 17 OF NwthStar ENGINEERING Civil Engineers • Planners • Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95926 916-893-1600 ': �- ► N:� � . � to <>� �T ►,J � ��1 _ _ �-, .� z: �. � . _ .� � _ z 1- 147 4 _ r z� i � .� �_-�_ �{ �)? -f Igo ��.�;.��f�.. _�► _ L 62 vz zTr- T- _ -I/- -- 2. '7 I/- - C2. 14, I 2 2 4-, I ': �- ► N:� � . � to <>� �T ►,J � ��1 _ _ �-, .� z: �. � . _ .� � _ z 1- 147 4 _ r SMEAR WALL SHEAR WALL NO 1 ND 2 NO 3 -SCHEDULE. NO 4 NO NO 6 NO NO 8 NO 9 ALLOWABLE LOAD/FOOT 260 380 490 550 640 130 980 1080 1280 12,8 PLYWOOD 3/8" 3/8" 3/8" 3/8" 3/8." 3/8" 3/8u CDX 37811-- STRUCT I 3/8" CDX CDX CDX CDX STRUCT I CDX STRUCT t BOTH 3 BOTH 3 BOTH 3 SIDES SIDES I SIDES EDGE NAILING 8d06" 8dis4" 8da3" 8d03"8dP2"48d02"4 8d P3" 8dQ3" 8d�2"4 FIELD NAILING Sd !a 12" 8d (a 12" 8d ia 12" 8d P 12" 8d 0 12" 8d .ia 12" 8d (@ 12" ' 8d (a 12" 8d is 12" SILL NAILING 516 16d @ 6" 16d 1@ 4" 20d (@ 4" 20d P 3"120d P 3" 20d 0 2" 20d 0 2" 20d P 2" 20d(@1-1/2" CLIP, BLOCK 1-550 L550 L590 LS90 L590 L590 LS90 A35 TO PLATE 0 22" 01411 X 16" 1 16" P 12" X 12" P 8" (a 4" _A35 p 4" ANCHOR BOLT 5/8" 0 5/8" 0 5/8" 0 5/8" m 5/8" 0 5/8" 0 3/4" 0 3/4" 0 3/4-0 A.B. (SPACING) 52" 36" 28" 24" 20" 16" 16" 16" 12" NOTES., I. OVER DOUGLAS FIR FRAMING 2. ALL PANEL EDGES BACKED WITH 2 -INCH NOMINAL OR WIDER FRAMING U.O.N. 3. PANEL JOINTS SHALL BE OFFSET 'TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE AS SHOWN IN NOTE $4 4. APPLIED OVER 3 -INCH NOMINAL OR WIDER FRAMING WITH NAILS STAGGERED 5. STAGGER ALL SILL NAILS 6. PRE -DRILL 20d AND LARGER 1. SIMPSON MANUFACTURED CLIPS OR APPROVED EQUAL 8. 1/2" TI -I1 SIDING MAY BE SUBSTITUTED FOR 3/6" PLYWOOD WHERE OCCURS N c = o S m con n r rn D D oD r co T j Z O F1 o D co �p Ln co < ry m rn 0 A BY: DATE: JOB NO: 550(:P PAGE 19 OF flofthStar ENGINEERING Civil Engineers 9 Planners e Surveyors 20 DECLARATION DRIVE -CHICO, CALIFORNIA 95926 916-893-1600 /-A/ I �4 c- 5 o/ PC AFAC�, 19 9 1 �4 E3.Cl Z_ x 310 + 1700 H r-, A WALL Z_ oAPI Fool TA F� CAPAC, IT'( Z&O i 00 0= 1416 ,1736z&o) Zoe 13 a.. � /.30 13) _TINA ]L-. H r-, A WALL Z_ oAPI Fool NAIL CAPAC, IT'( Z&O Z'30 5/-6 Z' ,1736z&o) 12N 5 (1,40) �Z 0 4— a 0 z 0G - 4(101) = 7Zzr ��G =='': .�p(j ��D) _ �?D 40 ZOe 7; Z 4 0 7,5; 73)0 131 -7 /7\ Zoe Z' 6 (13 1) 10�& 3/r .750700) = I Z75 AD ;/A A\ l.�c� Cdr li�-u U (181) = J� 4 �r� 3 1700 � f s^' l�� sem+ e< .,� y v,..► -•.w �`X a t'�w+` ? `J- ,�,�,t °•....-,.t� � r'a+%r,- r s,.g-,z�j"''�'p, y-. ��,�?."' ..�" �: r +r�' rpn vs5.z ` a ' !t}' r t Y f<'i• ZE s r*�' r}{*� a r �+ `ryfY vt` e�rc Zr:��c s 1 s'"'� i HD 1 ' "7r �:7;.t ...�nt:�.a._r.. :r,a�-�.ai,.::.a'i ___•- r-a:�37.%.:.7a:xa1?F•Fr�. CAR GUIDE SHOE,, GUIDE RAIL -'�r j COUNTERWEIGHT AND GUIDE SHOE )� o r I / z a DUMBWAITER CAR HW 1' CW f y,• z HAND ROPE lF l CD 11'IL {f `� PLANVIEW V i CEILING LINE UPPER )LEVEL � 'r DUMBWAITER MACHINE rf r. MACHINE SUPPORT l f' (WOOD) E DEFLECTING SLEAVE LEDGER BOARD SPRING BUMPER STOP ON RAIL ! ROPE GUIDE (WOOD) DUMBWAITER CAR H CH ADJUSTABLE SHELF a CAR DIMENSIONS Z (5 , wW 33� o�� ~N� L1prn W W 02 �� ..,oz WI- _ _ x x x QJd ILa< -+� -CL ZAWJ Zy u)2 03 O° vx U� Ua 0N� ...ZLU QY. fit W x `�� ° x V W x 820 60 48 50 40.6 76 22.7 68.5 F&FR 24" 19" 20" 16" 30" 50 27") 7-. R20 60 48 50 40.6 76 22.7 83.8 CP 24" 9" 1 20" 16" 30" 50 33"' ; 7-.9 { R24 71 58 60 50 91 34 78.7 F&FR 28" 23" 24" 20" 36" 75 31") g46 . R24 71 58 60. 50 91 34 93.9 CP 28" 23" 24" 20" 36" 75 367 37") Aa R28 81 68.5 71 60 91 45.4 88 256.5 F&FR 32" 27" 28" 24" 36" 100 35"i t8'-5 R28 81 68.5 71 60 91 45.5 104 2717 CP 32" 27" 28" 4" 36" 100 41" IB'•11 R32 91 78.7 81 71 91 52.2 96.5 264 F&FR 36" 31" 32" 28" 36" 115 38" 1 (81-8 ' R32 91 78.7 81 71 91 52.2 111.7 279 CID 36" 31" 32" 28" 36" 115 44.) I 91-2-1 y } CAR DIMENSIONS y Z MO UU) Wlu Qx 3:, Qx ��~ t:(/) UQp� WW a < 02 . x x W= ° xN xtoa I.- f' °Lry =0J -LL LU g� "p3 p0 U� UW UZI+J "3 4Ye 0o CLU 00 ` 0 x x ° -x W FF C24 71 58 60 50 91 68.1 78.7 246 F&FR 28" 23" 24" 20" 36" 150 31" 18'-1 C24 71 58 60 50 91 68.1 93.b 261 CP 28" 23" 24" 20" 36" 150 37'1(81-71 C28 81 68.5 71 60 91 79.5 88 1256.5 F&FR 32" 27" 28" 24" 36" 175 35" 8'•5 C28 81 68.5 71 60 91 79.5 104 271.7 CP 32" 27" 28" 24" 36" 175 41" 8'•11 1 C32 91 78.7 81 71 91 90.8 96.5 264 F&FR 36" 31" 32" 28" 36" 200 38" 6. C32 91 78.7 81 71 91 90.8 111.7 I 279 ^ CID 36" 31" 32" 200 44" 9'- C36 101.6 99 9t 06.6 114 106.6 289.5,F&FR 40" 39" L")36" 36" 42" 250 42" 9' C36 101.6 99 91 06.614 121.9 304.8CID 40" 39" 36" 42" 250 48") 1 10' ALL DIMENSIONS ARE FINISH (TOP NUMBERS ARE METRIC) HAND ROPE 9' GUIDE RAIL SPLICE S' r GUIDE RAILS r z a a a a 0 0 0 0 l OPEN FRONT OPENING FRONT & REAR OPENING CORNER UPPER FLOOR LINE (F) (FR) FRONT SIDE 1i I (CP . ;f' <t SHEETROCK BY OTHERS r. SPECIFICATIONS: COUNTERWEIGHT: Shall -onst j steel and adjustable. Shan • a prop° HOI ST TO SPECIFY: The dumbwaiter contractor shall minimize the amount of e0o iuiredfo CABLE furnish and install a manually operated traction type dumbwaiter with the rateed :o..,. dumbwaiter Model /f manufactured by Miller Manufacturing, Inc. CABLES44AND ROPE; Commemiald .- ir Dumbwaiter shall have a lifting capacity of hoist cable shall be aircraft cable 3l8 1 pounds. Dumbwaiter shall have stops, with an ultimate breaking strength of fi, ,', �,• with openings located on the (front) Residential dumbwaiter hoist cablesl),ed (front/rear) (front/light or left side) of hoistway. galvanized aircraft cable 3/16'7 XlarT Total dumbwaiter travel shall be feet breaking strength of 4200 pounds. H T+ inches. soft woven white polyester 3/4' in di J ! - swivel connector.-,,,;,; CAR: Car shall have dimensions of wide, - ,- "f'f.. " deep, high, and shall have GUIDE RAILS: Shall be 1/4-axlNded- ,� adjustable shelves. Car construction shall be aluminum shape guiding both car end„ , Guide rails shell De located on one std_a 1. Hardwood veneer �.. 2. Laminated Plastic ,;. splice brackets and installation sae s 3. Carbon steel, prime painted finish Y t provided for moun- I the gultle res' COUNTERWEIGHT 4. Stainless steel.` *' holatwey wad MACHINE: Shall have heavy steel support frames .- GUIDE SHOES FOR CAR AND COU held rigidly In place by cold roll steel tie rods Hoist �' •Shall De injected molded A-�on e4d r machine shall be fitted with self -aligning ball bearings4 tit"'lshigh atrength'with minima , rigWY for all rotating shafts. Shall be furnished with a fullyI 1: , - properties: Oulde_ehoe sr - • +o r r .P. f. automatic setting brake mechanism. Bfake y ±�y,t - j properly aligned to receive yu mechanism shall be adjustable. Brake components?!3,(%r"WOR B �OTHE S:;two0.Machine access4 shall be precision machined gray iron and aluminum :n .►f entraece doors. Finished hoistwsy S Drone. Machine shall have ample strength capable of supporting the ser with rated load and the C+ y+ ir, accordance with building codes-.FfOD,et ' SPRING BUMPER STOP pt/ gg it � pointeformacftfhe 6upports,end�lu� l 30 MIN. counterweight. The traction sheave shag be hea l j • �� We Fz. MOUNTED TO GUIDE RAIL east grey iron, with machined groove(s)properly.. ,+�_ WARRA Limited Frve year - designed to promote good traction and long cable Ille`- �. 2' s 4 Y"` FLOOR L NE LOWER LEVEL !. dr " vg��+ti`�„1�TOL E� y , �v^z .•,�, .j.� , 1'•(866f232 - ,:;e.'21 ..F. / Aj,' 7.R,•fk 4+aiiw-�R +. b y? MF.r: lid s'"++. y., •'L' "SE '. k, • "i`r t•'i`v*t�,�r'-' ..j� A SECTION rk 2` Yr•�q,'> '.j`i' i 'si'R L , aS�i . 1 OtY. ��<F"•t �`.,�1�+ ^+ 1'.. i't._ MILLERZ.rr`�*`i7 A, MANUFACTURING, INC. r 165 Cascade: Court • Rohnert ParkaCA94928 'x(707) 584=95285` FAX (707) 584 0850' } r 1 a ,�., C ?`w +rt -+' sr'�'i �'++£ .'^•">« i ai fl! "st!.'•'hr ri',+`. w- z+„'+C`;r+�y`�tri�."k +. ..•Mr '�, Mlrler Manufactunng,1990 SILENT SERVANT®)s'a'reg at if ,,ft ''•:ts ...,....,iu-•.w?zs4.4' rsvfydtc....+c:. Y C. rc-y:••��,,,,� m• ? _ 8 .+ w..am.-• •{ .+,7 �c? +c. �" . � „ Mada m Amarira We reserve the nciht to ehanoe ser?Cfieations a des ensl' alai[ ono, ilotrte??++' Printed 1 -TU&T;AGll_Z:) ���C� � � �� l ►--� �y �„� s -rte pct. S6A R Cv�►F,f� ' C 4w r _ r �� � - rod. ' fir- ►-� LW., .. - CLwt 1 tGk-� w� = l� -(i►�� j a C2 - Js F -AA -0 = J U 7 So jf- LF 1706-1708 1991 UNIFORM BUILDING CODE EXCEPTIONS: 1. Openings to the exterior maybe unprotected when permitted by Table No. 5-A or 9-C or Sections 1803 (b), 1903 (b), 2003 (b) and 2103 (b). 2. Openings protected by through -penetration fire stops to provide the same de- gree of fire resistance as the shaft enclosure. See Sections 4304 and 4305. (e) Rubbish and Linen Chute Termination Rooms. In other than Group R, Di- vision 3 Occupancies, rubbish and linen chutes shall terminate in rooms separated from the remainder of the building by an occupancy separation having the same fire resistance as required for the shaft enclosure, but not less than one hour. Open- ings into chutes and chute termination rooms shall not be located in exit corridors or stairways. For sprinklers, see Section 3802 (b). (f) Chute and Dumbwaiter Shafts. In buildings of Type V construction, chutes and dumbwaiter shafts with a cross-sectional area of not more than 9 square feet may be either of approved fire -resistive wall construction or may have the inside layers of the approved fire -resistive assembly replaced by a lining of not less than 0.019 -inch (26 -gage) galvanized sheet metal with all joints locklapped. The out- side layers of the wall shall be as required for the approved construction. All open- ings into any such enclosure shall be protected by not less than a self-closing solid wood door 13/8 inches thick or equivalent. Construction Joints Sec. 1707. Construction joints, such as those used to accommodate wind, seis- mic or expansion movements, installed in fire -resistive walls required to have pro- tected openings or in floors shall be protected with an approved material or construction assembly designed to provide the same degree of fire resistance as the floor or wall in which it is installed when tested in accordance with U.B.C. Stan- dard No. 43-1. See Section 4302 (b). Such material or construction assembly shall be securely installed in or on the joint for its entire length so as not to dislodge, loosen or otherwise impair its ability to accommodate expected building movements and to resist the spread of fire and hot gases. Weather Protection Sec. 1708. (a) Weather -resistive Barriers. All weather -exposed surfaces shall have a weather -resistive barrier to protect the interior wall covering. Such barrier shall be equal to that provided for in U.B.C. Standard No. 17-1 for kraft waterproof building paper or asphalt -saturated rag felt. Building paper and felt shall be free from holes and breaks other than those created by fasteners and construction sys- tem due to attaching of the building paper, and shall be applied over studs or sheath- ing of all exterior walls. Such felt or paper shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where vertical joints occur, felt or paper shall be lapped not less than 6 inches. Weather -protected barrier may be omitted in the following cases: 1. When exterior covering is of approved weatherproof panels. 2. In back -plastered construction. 3. When there is no human occupancy. 114 t 9 _ COUNTERWEIGHT AND GUIDE SHOE DUMBWAITER CAR 1i E CH 30" CW HAND ROPE CD CEILING LINE UPPER LEVEL DUMBWAITER MACHINE MACHINE SUPPORT (WOOD) DEFLECTING SLEAVE LEDGER BOARD SPRING BUMPER STOP ON RAIL ROPE GUIDE (WOOD) DUMBWAITER CAR ADJUSTABLE SHELF HAND ROPE GUIDE RAIL SPLICE GUIDE RAILS UPPER FLOOR LINE . . . .. I J CAR DIMENSIONS ' ZJ �2 �a t ~y^ Upm _W W OZ i 9 20 ` PLAN VIEW 1i E CH 30" CW HAND ROPE CD CEILING LINE UPPER LEVEL DUMBWAITER MACHINE MACHINE SUPPORT (WOOD) DEFLECTING SLEAVE LEDGER BOARD SPRING BUMPER STOP ON RAIL ROPE GUIDE (WOOD) DUMBWAITER CAR ADJUSTABLE SHELF HAND ROPE GUIDE RAIL SPLICE GUIDE RAILS UPPER FLOOR LINE . . . .. I J 1i E CH 30" CW HAND ROPE CD CEILING LINE UPPER LEVEL DUMBWAITER MACHINE MACHINE SUPPORT (WOOD) DEFLECTING SLEAVE LEDGER BOARD SPRING BUMPER STOP ON RAIL ROPE GUIDE (WOOD) DUMBWAITER CAR ADJUSTABLE SHELF HAND ROPE GUIDE RAIL SPLICE GUIDE RAILS UPPER FLOOR LINE 1' J CAR DIMENSIONS ' ZJ �2 ~y^ Upm _W W OZ i 9 20 F Wa pU 3t -p a W 3p xo-xU aJd ym G UD�a, W UZ yaa oUul O W 23 W r.0 R20 60 48 50_74D6 76 22.7 68.5 221 FBFR 24" _ 19" 20" 16" 30 50 27: R20 60 48 50 40.6 76 22.7 83.8 23g CP 24 19" 20" 16" 30" 50 331 ' .p R24 71 58 60 50 91 34 78.1 246 FBFR 28" 23" 24" 20" 36' 75 31'I :.,•, R24 71 58 60. 50 91 34 93.9 26; CP 28 23" 24" 20" 36" 75 (37"' �'.7-, . 4 88p R28 81 68.5 71 60 91 45.4 FBFR 32" 27" 28" 24" 36" 100 35". R28 81 68.5 .71 60 91 45.5 104 CP 32 27' 28" 4 36" 100 41'1 13'•1;^,; 832 91 78.7 81 71 91 52.2 96.5 264 FBFR 36 31" 32" 28' 36" 115 , 38") 18'-P',; R32 91 78.7 81 71 91 52.2 111.7 279 CP 36" 31" 32" 28" 36' 115 (44') (9'•21 J Q > } CAR DIMENSIONS >. Z U U) _Q 3Ha Q O1"'a. H N W W x x W2 WW QUJIL _�_x021", 4 ."Opts 22 03 DU Ge 3 UW VZW UN 00 p U x x O -x W C24 71 1 58 60 50 91 68.1 78.7 246 FBFR 28" 23" 24" 20" 36" 150 31" 8'-11 93.S 281 . C24 71 58 60 50 91 68.1 CID 28' 23" 24" 20" 36" 150 37'; 18'•7^:1 = C28 81 68.5 71 60 91 79.5 88 256.5 , ` FBFR 32" 27" 28" 24" 36" 175 35"1 • 18'•51 81 68.5 71 60 91 79.5 104 271.7 32" 27" 28" 24^ 36" 175 41' 8'-1t'i 91 78.7 81 71 91 90.8 96.5 1 264 36" 31" 32" 28" 36" 200 38"1 1 (6.2^1 91 78.7 81 71 91 90.8 111.7 279 tC36101.6 36" 31' 32" 28" 36" 200 44" l (9'-- ' 101.6 99 91 91 106.6 114 106.6 289.5 - 40" 39" 36" 36" (42" (250) (42") ' (9'-E'-: 99 91 91 106.6 114 121.9 304(40" 139" (36") (36") '(42") (250) (48") (10'1 ALL DIMENSIUNS AHt f-1NISH (I UI-• NUMUtrSa Alae mel ml%,) , 'F F- _:�:3 z a 0 FRONT OPENING (F) z z CL Q_ 0 0 FRONT 8 REAR OPENING (FR) N SHEETROCK BY OTHERS SPECIFICATIONS: COUNTERWEIGHT: Shall' ",strut i steel and adjustable. Sha:, proper H01 ST TO SPECIFY: The dumbwaiter contractor Shall minimize the amount of el:. uired to s� CABLE furnish and install a manually operated traction type dumbwaiter with the raleec dumbwaiter Model manufactured by Miller Manufacturing. Inc. CABLESIHAND ROPE: Commercial Dumbwaiter shall have a lilting capacity of hoist cable shah be aircraft cable 1f816 2 pounds. Dumbwaiter shall have stops. with an ultimate breaking suength of hall with openings located on the (front) Residential dumbwaiter hoist cable 5h�- (front/rear) (front/right or lett side) of hoistway. galvanized aircraft cable 3116'7 11%, Total dumbwaiter travel shall be feet breaking strength o1 A200 pounds. -• • intoes. sols woven white polyester 3/a' in diaR swivel connector. CAR: Car Shall have dimensions of wide. deep, high, and shall have GUIDE RAILS: Shall be 1/4• eitmded adjustable shelves. Car construction shall be: aluminum shape guiding Doth cat and r.E 1. Hardwood veneer Guide rails shall be located on one Side?1' i. Laminated sneer splice brackets end installation saea'S..: provided for mounting the guide tail . COUNTERWEIGHT 3. Carbon Steel, prime painted finish hoistway wall", 1. Stainless Steel - � . • _ ..• .. MACHINE: Shell have heavy steel support frames - GUIDE SHOES FOR CAR AND CDU Shall be Injeaed molded t -TAL CO held rigidly in plate by sold roll steel tie rods. Hetet '.'; high strength with minima ::`p^ ' machine shall Defined with self -aligning Dell bearings `+,+: g rigidlff. for all rotating shafts. Shall be furnished with a fully'' properties. Guide shoe s: - ::'`�;8.; °� = properly aligned to receive ,. a r automatic selling Drake mechanism. Brake .. ' - mechanism shalt De adjustable. Brake components = WORX BY OTHERS: Machine act°ss, shalt be precision machined gray Iron and aluminum entrance opera. Finished hoistway - bronze. Machine shell have ample strength capable ol•,� .. accerdande wdh building codes. Pkii r? supporting the car with rated load and the ;;',fit jj;v, ; }? polnls tar machine supports and g4. SPRING BUMPER STOP counterwei ht. The traction sheave shall De heavy; �f'. ,' , y S ..;, ", a.. 30" MIN. g 1. e MOUNTED TO GUIDE RAIL easlgreylron,withmeeNnedgroove(s)properfy`;Ct'z p:'WARRANTY-Umited_FveYeerW,.. • •' ,r designed to promote good traction and long cable fife' a'r; r`Y, r. TOL~FREE FLOOR LINE LOWER LEVEL r1 sir ?1 (80U).232 21TT SECTION MA r , n . ' MILLER :yr .a'`"r �2�?�og x.3(5?ps z ,. '. MANUFACTURING, INC.. t" - 165 Cascade Court; Rohnert. Park ,CA 94928 (707) 584-9528' FAX (70.584 0850.' c <g a `• .-. - wit h % ".M•.: _ . C Miller Manufacturing 1990,27 : SILENT SERVAN7s_Isa refl U S.°pat. I t n Pr , Matle in America - We reserve the ri M to than a soeclhcations or desi'-twithdd OnOr notlCn ATTACHMENT "A" WEIBEL RESIDENCE Calculation Index: Moment Frame Layout • Lateral Load Development • Moment Frame Loading Layout • Moment Frame Analysis , • Footing Analysis Page # Att. A -Sht. 1 Att. A Sht. 2-6 Att. A Sht. 7-13 Att. A Sht. 14-38 Att. A Sht. 39-45 Revision. Summary: Rev. 0 Initial Issue ,a �QQ®EFs��P��Q Beg.. A 1. w 1 .jai tet- rr r_ + p�Oj 1 a � i N SI N m I I �=N >ogogans9XLtn G} - O o ' >o9o98f11 o09o9Bn1 +y ' a' 9 0 j O� 7 XL to i r - m } N +�O 0�� o d p ° d S O O n a m 3 � a ' l aogogen, jai so9ogeni s=s y'U i 0 o N O � 2 O N} S O u B O 0 O z £ 0 m d a o O ° m m O s= t 9o9fif11 1 s9XLtn t Q o ;s m s=s r 0 y �} 0 s - s9XL to � N k z z z z i .jai . l t 1 09/05/95 Lateral Analysis - Weibel Res. - RCE Job 95-032 IUBC Wind Loads -- Method 1 p= Ce•Cq•gs•I P= P= P= P= P= P= IWW Of W 1WR OWR OLR OPR Wind Spee 75 mph Exposure: C where; Ce = Ce = Ce = Ce = Ce = Ce = Cq = Cq = Cq = Cq = Cq = qs = Roof Slope = Py 2 1.06 @ 0 to 15' 1.13 @ 15 to 20' 1.19 @ 20 to 25' 1.23 @25 to 30' 1.31 @ 30 to 40' 1.43 @ 40 to 60' 0.8 (IWW) Inward @ Windward Wall 0.5 (OLW) Outward @ Leeward Wall 0.3 (IWR) Inward @ Windward Roof 0.7 (OWR) Outward @ Windward Roof 0.7 (OLR) Outward @ Leeward Roof 0.7 (OPR) Outward @ Parallel To Ridge 14.4 psf 1.00 Importance Factor 4 Rise to 12 Horiz. North - South Wind Analysis (2nd Level) Tributary Normal �b�I�f�Q6lLi6![ib! • Normal Resultant Horizontal Area Pressure Force Area Pressure Mean Roof Height 25 feet 2.0 Wind Spee 75 mph Exposure: C where; Ce = Ce = Ce = Ce = Ce = Ce = Cq = Cq = Cq = Cq = Cq = qs = Roof Slope = Py 2 1.06 @ 0 to 15' 1.13 @ 15 to 20' 1.19 @ 20 to 25' 1.23 @25 to 30' 1.31 @ 30 to 40' 1.43 @ 40 to 60' 0.8 (IWW) Inward @ Windward Wall 0.5 (OLW) Outward @ Leeward Wall 0.3 (IWR) Inward @ Windward Roof 0.7 (OWR) Outward @ Windward Roof 0.7 (OLR) Outward @ Leeward Roof 0.7 (OPR) Outward @ Parallel To Ridge 14.4 psf 1.00 Importance Factor 4 Rise to 12 Horiz. North - South Wind Analysis (2nd Level) Tributary Normal Resultant Horizontal Normal Resultant Horizontal Area Pressure Force Area Pressure Mean Roof Height 25 feet 2.0 feet @ 13.0 psf = 26 lbs. (IWW) @ 15 to 20' 3.0 feet @ 13.7 psf. = 41 lbs. (IWW) @ 20 to 25' 5.0 feet @ 8.6 psf = 43 lbs. (OLW) @ 20 to 25' 2.0 feet.@ 5.1 psf = 3 lbs. (IWR) @ 20 to 25' . 3.0 feet @ 5.3 psf = 5 lbs. (IWR) @ 25 to 30' 5.0 feet @ 12.0 .psf = 19 lbs. (OLR) @ 20 to 25' Fp =137 P oriz. r North - South Wind Analysis (1 st Level) Tributary Normal Resultant Horizontal Area Pressure Force Mean Roof Height 25 feet 8.5 feet @ 12.2 psf = 104 lbs. (IWW) @ 0 to 15' 3.0 feet @ 13.0 psf = 39 lbs. (IWW) @ 15 to 20' 1 1.5 feet @ 8.6 psf = 99 lbs. (OLW) ,@ 15 to 20' �/ Fp = 1 p f - horiz. East - West Wind Analysis (2nd Level) Tributary Normal Resultant Horizontal Area Pressure Force Mean Roof Height 25 feet 2.0 feet @ 13.0 psf = ✓ 26 lbs. (IWW) @.15 to 20' 2.0 feet @ 13.7 psf = 27 lbs. (IWW) @ 20 to 25' 5.0 feet @ 8.6 psf = . 43 lbs. (OLW) _ @ 20 to 25' 2.0 feet @ 5.1 psf = 3 lbs. (IWR) @ 20 to 25' 3.0 feet @ 5.3 psf = 5 lbs. (IWR) @ 25 to 30' 5.0 feet @ 12.0 psf = 19 lbs. (OLR) @ 20 to 25' Fp =. p -oriz. East -West Wind Analysis (1 st Level) Tributary Normal Resultant Horizontal Area Pressure Force Mean Roof Height 2.5 feet 8.5 feet @ 12.2 psf = 104 lbs. (IWW) @ 0 to 15' 3.0 feet @ 13.0 psf = 39 lbs. (IWW) @ 15 to 20' 11.5 feet @ 8.6 psf = 99 lbs. (OLW) @ 15 to 20' Fp = 1 p oriz. t 09/05/95 - Lateral Analysis -. Weibel Res. - RCE Job 95-032 P� 3 UBC Seismic Loads - Static Force Procedure V= (Z•1•C/Rw)•W where; Z = 0.3 Zone 3 I = 1.00 Importance Factor _ p= 0.138 •W C = '2.75 maximum RW = 6.0 W = Building Weight North - South Seismic Loading Tributary Weights = 54.00 feet of Roof @ 22.03 psf Living Room 2nd Level Loadings 11.00 feet of Ext. Wall @ 15.00 Of V =1. 186 plr- oriz. North - South Seismic Loading Tributary Weights = 24.00 feet of Roof.@ 22.03 psf Dining K Music 2nd Level Loadings 1 1.00 feet of Ext. Wall @ 15.00 plf V 95 p - oriz. North - South Seismic Loading Tributary Weights = 19.00 feet of Carpet Floor 12.00 psf Living Room 1 st Level Loadings 16.00 feet of Tile Floor @ • 21.50. plf 23.00 feet of Ext. Wall @ 15.00 plf V 126 p - oriz. North - South Seismic Loading Tributary Weights = 16.00 feet of Tile Floor @ 21.50 plf Dining 8z Music 1 st Level Loadings 23.00 feet of Ext. Wall @ 15.00 pif V 95 plforiz. East - West Seismic Loading Tributary Weights = 34.00 feet of Roof @ 22.03 psf Living Room 2nd Level Loadings 11.00 feet of Ext. Wall @ 15.00 pif V 126 p 17.oriz. East - West Seismic Loading Tributary Weights = 75.00 feet of Roof @ 22.03 psf Dining 8z Music 2nd Level Loadings 11.00 feet of Ext. Wall @ 15.00 pif V 250 p - oriz. East - West Seismic Loading Tributary Weights = 54.00 feet of, Carpet Floor 12.00 plf Living Room 1st Level Loadings 23.00 feet of Ext. Wall @ 15.00 plf V 137 p - oriz. East - West Seismic Loading Tributary Weights = 75.00 feet of Tile Floor @ 21.50 psf Dining 81 Music 1 st Level Loadings 23.00 feet of Ext. Wall @ 15.00 plf V 269 p oriz. 09%12/95 - Lateral Analysis - Weibel Res. -'RCE job 95-032 Lateral Load Summary Wall Line 8z Load Level ID Tributary Length ft. Unit Loads Seismic Wind k.l.f.) k.l.f. Wall Loads Seismic Wind kis (kips) Controlling Load Case D - West 2nd 8.00 0.095 0.137 0.763 1.098 Wind Controls D - East 2nd 13:00 -0.186 0.137 2.421 1.784 Seismic Controls G - West (2nd) 13.00 0.186 0.137 2.421 1.784 Seismic Controls G - East (2nd) 16.50 0.095 0.137 1.574 2.265 Wind Controls D - West 1st 12.50 0.095 0.241 1.184 3.017 Wind Controls D - .East 1 st 13.00 0.126 0.241 1.639 3.138 Wind Controls G - West l st 3.00 13.0940 0.126 0.241 1.639 3.138 Wind Controls G - East (1 st) 15.00 0.095 0.241 1.421 3.621 Wind Controls 8 - 2nd) 3.75 0.186 0.124 0.698 0.463 Seismic Controls 7 - North 2nd) 3.75 0.186 0.124 _ 0.698 0.463 Seismic Controls 7 -South 2nd 6.00 0.186 0.124 ' 1.1 18 0.741 Seismic Controls 6 - North 2nd 6.00 0.186 0.124 1.118 0.741 Seismic Controls 6 - South 2nd 8.00 0.095 0.124 0.763 0.988 Wind Controls 8 - l st) 3.75 0.126 0.241 0.473 0.905 Wind Controls 7 - North 1 st) 3.75 0.126 0.241 0.473 0.905 Wind Controls 7 - South 1 st 6.00 0.126 0.241 0.757 1.448 Wind Controls 6 - North (1 st 6.00 0.126 0.241 0.757 1.448 Wind Controls 6 -South (1st) 8.00 0.095 0.241 0.758. 1.931 Wind Controls 09/12/95 = Lateral Analysis - Weibel Res. - RCE job 95-032 SHEAR STRESSES AND SHEAR ANCHORAGE SUMMARY Wall ine ID ----- Wall Loads Seismic Wind (kips) (kips) Wall Length (feet) WallHorizontal Stresses (plf) Diaphragm Lengths u Stresses Sill Plate Shear Anchorage Bolt Dia. (in.) or Connector Type Capacity (kips) Spacing (feet) (plf) (feet) (pin West Side East Side----�'J err D@ 2nd Level D@ 1 st Level 3.18 2.88 10 318 16 69 34 71 0.500 0.841 24 inches O.C. 16 189 34 92 ( G@ 2nd Level G@ 1 st Level 4.00 4.05 10 405 34 71 16 142 --o-.50.0_ 0,841 .24_inches_oxcr 16 196 34 106 North Side South Side 8@ 2nd Level 7@ 1 st Level 7@ 2nd Level B@ 1 st Level 6@ 2nd Level 6@ 1 st Level 0.70 0.47 1.82 1.23 1.88 1.51 0.46 0.91 1.20 2.35 1.73 3.38 N/A N/A N/A N/A N/A N/A 26 27 N/A N/A N/A J J j 26 35 26 27 26 43 26 35 26 56 26 43 75 13 26 56 54 36 . 0 hGl N ea 3G v C, ` War le 09/12/95 - Lateral Analysis - Weibel Res. - RCE Job 95-032 Wall ine ID a Load (kips) Lo—ad Type a Height (feet) a Length (feet) Applied OTM (foot -kips) Forces Resisting Uniform Load Point Load (WO (kips) Resistive OTM (foot -kips) et p i Force (kips) Comments n eve eismic . 357 )ED STUD ON TOP.OF THE STEEL BEAM 2.88 Wind 10.00 10.00 28.82 0.250 8.33 2.049 HD5A BOLTED TO A WELDED STUD ON TOP OF THE STEEL BEAM Znd LevelSeismic18.28 2.168 HD5A k WELDED STUD ON TOP OF THE STEEL BEAM 4.05 Wind 10.00 10.00 40.49 0.250 8.33 3.216 HDSA BOLTED TO A WELDED STUD ON TOP OF THE STEEL BEAM P� -4 Po PC I o PC3 1l 4 - S � 3 O O N I C O IZ • J 6 N O Q O 6 N • S O n • O u N p ^ , r a a N i W O O I 6 O - r L 6 . O N O O a PAGE NO. 1 y User ID: R.C.E. * S T A A D - III * Revision 20.OW * Proprietary Program of * RESEARCH ENGINEERS, Inc. * Date= SEP 6, 1995 * Time= 6: 9:57 + + * USER ID: R.C.E. ++++++++++++++++++++++++++++++++++++++++++++++++++ 1. STAAD SPACE WEIBEL RESIDENCE MOMENT FRAME 2. INPUT WIDTH 72 3. UNIT FEET KIP 4. JOINT COORDINATES 5. 1 13. 0. 0.; 2 13. 12. 0.; 3 13. 0. 12.; 4 13. -12. 12.; 5 5.2 0'. 16.5 6. 6 5.2 12,. 16.5; 7 13. 22.9 12.; 8 5.2 22.9 16.5; 9 0. 12. 19.5 7. 10 0. 22.9 19.5; 11 -13. 0. 0.; 12 -13. 12. 0.; 13 -13. 0.:12. 8. 14 -13. 12. 12.; 15 -5.2 0. 16.5; 16 -5.2 12. 16.5; 17 -13". 22.9 12. 9. 18 -5.2 22.9 16.5; 19 13. 12. 6.5; 20 -13. 12. 6.5; 21 13. 23. 6.5 10. 22 0. 27.333 6.5; 23 -13. 23. 6.5; 24 0. 23. 6:5; 25 5.2 12. 12. 11. 26 5.2 12. 0.; 27 -5.2 12. 12.; 28 -5.2 12. 0.; 30 17. 21.667 13.692 12. 31 0.'21.667 23.843; 32 -17. 21.667.13.692; 33 13. 23. 12. 13. 34 0. 23. 19.5; 35 -13. 23. 12. 14. MEMBER INCIDENCES 15. 1 1 2; 2 3 4; 3 5 6;.4 4 7; 5 6 8; 6 4 6; ' 7 6 9; 8 7 8; 9 8 10; 10 11 12 16. 11 13 14; 12 15 16; 13 14 17; 14 16 18; 15 14 16; 16 16 9; 17 17 18 17. 18 18 10; 19 2 19; 20 19 4; 21 12 20; 22 20 14;.23 19 21; 24 33 22 18. 25 35 22; 26 20 23; 27 34 22; 28 21 24; 29 23 24; 30 22 24; 31 6 25 19. 32 25 26; 33 16 27; 34 27 28; 35 12 28; 36 28 26; 37 26 2;'38 14 27 20. 39 27 25; 40 25 4; 45 7 21; 46 17 23; 47 33 30; 48 34 31; 49 35 32 21. 50 7 33; 51 10 34; 52 17 35 22. UNIT INCHES KIP 23. MEMBER PROPERTY AMERICAN 24. *STEEL SECTIONS 25. 1 2 10 11 TABLE ST W12X65 26. 3 TO 9 12 TO 18 TABLE ST TUB60604 27. 19 TO 22 TABLE ST W14X30. 28. 31 TO 34 TABLE ST W8X28 29. 35 TO 40 TABLE ST W14X30 30. *GLU-LAMS 31. 28 29 PRI YD 18. ZD 5.125 12. 24 25 27 47 TO 49 PRI YD 18. ZD 5.125 33. *SAWN LUMBER 34. 23 26 30 PRI YD 5.5 ZD 5.5 35. 45.46 PRI YD 3. ZD 5.5 36. *DUMMY MEMBER 37. 50 TO 52 PRI YD 5.5 ZD 5.5 38. MEMBER RELEASE 39. 6 15 23 26 28 TO 34 45 46 START MY MZ 40. 23 TO 27 30 TO 3445 46 50 TO 52 END MY MZ 41. UNIT FEET KIP WEIBEL RESIDENCE MOMENT FRAME 42. CONSTANTS 43. BETA 90. MEMB 1 2 10 11 44. BETA 30. MEMB 3 TO 5 45. BETA 60. MEMB 12 TO 14 46. E STEEL MEMB 1 TO 22 31 TO 40 47. POISSON STEEL MEMB 1 TO 22 34 TO 40 48: DENSITY STEEL MEMB 1 TO 22 34 TO 40 49. UNIT INCHES KIP 50. CONSTANTS 51. E 1600. MEMB 23.26 30 45 46 52. E 1800. MEMB 24 25 27 TO 29 47 TO 52 53. UNIT FEET POUND 54. CONSTANTS 55. DENSITY 40. MEMB 23 TO 30 45 TO 52 56. SUPPORTS 57. 1 3 5 11 13 15 PINNED 58. LOAD 1 DEAD LOADS 59. SELFWEIGHT Y -1. 60. JOINT LOAD 61. *RIDGE BEAM REACTION 62. 22 FY -1540. 63. MEMBER LOAD 64. 24 25 27 TRAP Y 0. -71.5 0. 0. 65. *176 PLF ROOF 66. 8 9 17 18 UNI Y -176. 67. *242 PLF ROOF + 165 PLF WALL + 48 PLF FLOOR 68. 19 TO 22 UNI Y -456. 69. *WALL LOAD . 70. 6 7 15 16 UNI Y-165. 71. *FLOOR LOADS 72. 32 34 UNI Y -108. 73. 31'33 TRAP Y 0.1-108. 0. 0. 74. *ROOF LOAD AT OVERHANG 75. 47 TO 49 TRAP Y -44. 0. 0. 0. 76. LOAD 2 -FLOOR LIVE LOADS 77. MEMBER LOAD 78. 32 34 UNI Y -360. 79. 19 TO 22 UNI Y -160. 80. 31 33 TRAP Y 0. -360. 0. 0. 81. LOAD 3 ROOF LIVE LOADS 82. JOINT LOAD 83. *RIDGE BEAM REACTION 84. 22 FY -1120. J 85. MEMBER LOAD 86. 24 25 27 TRAP Y 0. -52. 0. 0. 87. 8 9 17 18 UNI Y -128. 88. 19'TO 22 UNI Y -176. 89. *ROOF LOAD AT OVERHANG 90. 47 TO 49 TRAP Y -32. 0. 0. 0. 91. LOAD 4 EAST -WEST WIND LOADS 92. JOINT LOAD 93. *2ND LEVEL LOADS 94. 10 FX 463. 95. 17 FX 1204. 96. *1ST LEVEL LOADS 97. 9 FX 905. -- PAGE NO. 5 User ID: R.C.E. WEIBEL RESIDENCE MOMENT FRAME 98. 14 FX 2353. 99..12 FX 3379. 100. LOAD 5 NORTH -SOUTH WIND 101. JOINT LOAD 102. *LATERAL LOADS FROM SHEAR WALLS ABOVE 103. 2 FZ 2882. 104. 12 FZ 4049. 105. *OVERTURNING LOADS FROM SHEAR WALLS ABOVE 106. 2 FY 2882. 107. 4 FY -2882. 108. 12 FY 4049. 109. 14 FY -4049. 110. *LOADS FROM•FLOOR DIAPHRAGM 111. 2 FZ 6155. 112. 12 FZ 6759. 113. LOAD 6 EAST -WEST SEISMIC 114. JOINT LOAD 115. *2ND LEVEL LOADS 116. 10 FX 698. 117. 17 FX 1816. 118. *1ST LEVEL LOADS 119. 9 FX 473. 120. 14 FX 1230. 121. 12 FX 1515. 122. LOAD 7 NORTH -SOUTH SEISMIC 123. JOINT LOAD 124. *LATERAL LOADS FROM SHEAR WALLS ABOVE 125. 2 FZ 3185. 126. 12 FZ 3995. 127. *OVERTURNING LOADS FROM SHEAR WALLS ABOVE 128.2 FY 3185. 129. 4 FY -3185. 130. 12 FY 3995. 131. 14 FY -3995. 132. *LOADS FROM FLOOR DIAPHRAGM 133. 2 FZ 2823. 134. 12 FZ 3060. 135. *LATERAL LOAD FROM MASONRY FIREPLACE 136. *(18SQ FT * 150 PCF * 17' *ZIC/R)/2- 137. 26 28 FZ 3156. 138. LOAD COMB 8 D + FL + RL 139. 1 1. 2 1. 3 1. 140. LOAD COMB 9 D + FL + E -W WIND 141. 1 1. 2 1. 4.1.' 142. LOAD COMB 10 D + FL - E -W WIND 143. 1 1. 2 1. 4 -1. 144. LOAD COMB 11 D + FL + N -S WIND 145. 1 1. 2 1. 5 1. 146. LOAD COMB 12 D + FL - N -S WIND 147. 1 1. 2 1. 5 -1. 148. LOAD COMB 13 D + FL + E -W SEISMIC 149. 1 1. 2 1. 6 1. 150. LOAD COMB 14 D + FL - E -W SEISMIC 151. 1 1. 2 1. 6 -1. 152. LOAD COMB 15 D + FL + N -S SEISMIC 153. 1 1. 2 1. 7 1. PAGE NO. �3' /(/ User ID: R.C.E. WEIBEL RESIDENCE MOMENT FRAME 154. LOAD COMB 16 D + FL - N -S SEISMIC 155, 1 1. 2 1. 7 -1. 156. LOAD COMB 17 .67D + E -W WIND 157. 1 0.667 4 1. 158. LOAD COMB 18 .67D - E -W WIND 159. 1 0.667 4 -1. 160. LOAD COMB 19 .67D + N -S WIND 161. 1 0.667 5 1. 162. LOAD COMB 20 .67D - N -S WIND 163. 1 0.667 5 -1. 164. LOAD_ COMB 21 .85D + E -W SEISMIC 165. 1 0.85 6 1. 166. LOAD.COMB 22 .851) - E -W SEISMIC 167. 1 0.85 6 -1. 168. LOAD COMB 23 .85D + N -S SEISMIC 169. 1 0.85 7 1. 170. LOAD COMB 24 .85D - N -S SEISMIC 171. 1 0.85 7 -1. 172. LOAD COMB 25 COLUMN AXIAL COMPRESSION 173. 1 1. 2 0.7 3 0.7 6 2.25 7 0.625 174. LOAD COMB 26 COLUMN AXIAL COMPRESSION 175. 1 1. 2 0.7 3 0.7 6 2.25 7 -0.625 176. LOAD COMB 27 COLUMN AXIAL COMPRESSION 177. 1 1. 2 0.7 3 0.7 6 -2.25 7 0.625 178. 'LOAD COMB 28 COLUMN AXIAL COMPRESSION 179. 1 1. 2 0.7 3 0.7 6 -2.25 7 -0.625 180. LOAD COMB 29 COLUMN AXIAL COMPRESSION 181. 1 1. 2 0.7 3 0.7 6 0.625 7 2.25 182. LOAD COMB 30 COLUMN AXIAL COMPRESSION 183. 1 1. 2 0.7 3 0.7 6 -0.625 7 2.25 184. LOAD COMB 31 COLUMN AXIAL COMPRESSION 185. 1 1. 2 0.7 3 0.7 6 0.625 7 -2.25 186. LOAD COMB 32 COLUMN AXIAL COMPRESSION 187. 1 1. 2 0.7 3 0.7 6 -0.625 7 -2.25 188. LOAD COMB 33 COLUMN AXIAL TENSION 189. 1 0.85 6 2.25 190. LOAD COMB 34 COLUMN AXIAL TENSION 191. 1 0.85 6 -2.25 192. LOAD COMB 35 COLUMN AXIAL TENSION 193. 1 0.85 6 2.25 194. LOAD COMB 36 COLUMN AXIAL TENSION 195. 1 0.85 7 -2.25 196. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- - - PAGE NO. User ID: R.C.E. NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 34/ 48/ 6 ORIGINAL/FINAL BAND -WIDTH = 2S/ 9 TOTAL PRIMARY LOAD CASES = 7, TOTAL DEGREES OF FREEDOM = 186 SIZE OF STIFFNESS MATRIX = 10602 DOUBLE PREC. WORDS REQRD/AVAIL. DISK SPACE = 12.28/ 233.4 MB, EXMEM = 59.17 MB ++ PROCESSING ELEMENT STIFFNESS MATRIX. 6: 9:58 WEIBEL RESIDENCE MOMENT FRAME ++ PROCESSING GLOBAL STIFFNESS MATRIX. ++ PROCESSING TRIANGULAR FACTORIZATION. -- PAGE NO. 'b User ID: R.C.E. 6: 9:58 6: 9:58 ***WARNING - IMPROPER LOAD WILL CAUSE INSTABILITY AT JOINT 23 DIRECTION = FX PROBABLE CAUSE MODELING PROBLEM 0.000E+00 ***WARNING - IMPROPER LOAD WILL CAUSE INSTABILITY AT JOINT 23 DIRECTION = MX PROBABLE CAUSE MODELING PROBLEM 0.000E+00 ++ CALCULATING JOINT DISPLACEMENTS. 6: 9:58 ++ CALCULATING MEMBER FORCES. 6: 9:59 197. PLOT SECTION FILE 198. LOAD LIST 1 2 3 8 199. UNIT INCHES KIP 200. PARAMETER 201. CODE AISC 202. FYLD 42. MEMB 3 TO 9 12 TO 18 203. FYLD 36. MEMB 1 2 10 11 19 TO 22 31 TO 40 204. RATIO 1. MEMB 1 TO 22 31 TO 40 205. BEAM 1. MEMB 1 TO 22 31 TO 40 206. CHECK CODE MEMB 1 TO 22 31 TO 40 WEIBEL RESIDENCE MOMENT FRAME -- PAGE NO. 'el User ID: R.C.E. STAAD-III CODE CHECKING - (AISC) +++++++++++++++++++++++ ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ ----------------------------------------------------------------------- ----------------------------------------------------------------------- FX MY MZ LOCATION 1 ST W12 X65 PASS AISC- H1-3 0.272 8 10.44 C .138.04 138.85 144.00 2 ST W12 X65 PASS AISC- H1-3 0.255 8 14.19 C 133.55 -93.31 144.00 3 ST TUB 60604 PASS AISC- H1-3 0.087 8 6.64 C 4.18 -2.38 144.00 4 -ST TUB 60604 . PASS AISC- H1-3 0.316 8 2.55 C 37.00 37.77 0.00 5 ST TUB 60604 PASS AISC- H1-3 0.207 8 3.97 C -17.41 26.28 130.80 6 ST TUB 60604 PASS AISC- H1-3 0.087 1. 0.42 C 1.18 -20.00 10.8.06 7 ST TUB 60604 PASS AISC- H1-3 0.150 8 0.31 C -6.44 31.10 0.00 8 ST TUB 60604 PASS AISC- H1-3 0.179 8 0.15 C 7.20 -38.08 108.06 9 ST TUB 60604. PASS AISC- H1-3 0.267 8 0.48 C -2.73 64.36 0.00 10 ST W12 X65 PASS AISC- H1-3 0.273 8 10.51 C -138.09 138.96 144.00 11 ST W12 X65 PASS AISC- H1-3 0.256 8 14.26 C :-133.75 -93.26 144.00 12 ST TUB 60604 PASS AISC- H1-3 0.087 8 6.63 C 2.63 -4.13 144.00 13 ST TUB 60604 PASS AISC- H1-3 0.318 8 2.55 C -38.04 -37.04 0.00 14 ST TUB 60604 PASS AISC- H1-3 0.206 8 3.97.0 -26.13 17.43 130.80 15 ST TUB 60604 PASS AISC- H1-3 0.087 1 0.42 C -1.17 -20.13 108.06 16 ST TUB 60604 PASS AISC- H1-3 0.149 8 0.31 C 6.41 30.89 0.00 17 ST TUB 60604 PASS AISC- H1-3 0.179 8 0.15 C -7.19 -38.15 108.06 18 ST TUB 60604 PASS AISC- H1-3 0.267 8 0.48 C 2.74 64.27 0.00 19 ST W14 X30 PASS AISC- H1-3 0.164 8 0.94 C -0.80 153.32 78.00 20 ST W14 X30 PASS AISC- H1-3 0.164 8 0.94 C 0.80 -153.32 0.00 21 ST W14 X30 PASS AISC- H1-3 0.164 8 0.94 C 0.80 153.34 78.00 WEIBEL RESIDENCE MOMENT FRAME PAGE NO. Z p User ID: R.C.E.. ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION 22 ST W14 X30 PASS AISC- H1-3 0:164 8 0.94 C -0.80 -153.34 0.00 31 ST W8X 28 PASS SHEAR -Y 0.021 8 0.01 C" 0.00 -7.36 31.50 32 ST W8X 28 PASS AISC- H1-3 0.193 8 0.03 C 0.00 -101.09 72.00 33 ST W8X 28 PASS SHEAR -Y 0.021 8 0.01 Ci 0.00 -7.36 31.50 34 ST W8X 28PASS AISC- H1-3 0.204 8 0.03 C 0.00 -107.14 72.00 35 ST W14 X30 PASS AISC- H1-3 0.189 8 0.93 C: -0.77 161.37 93.60 36 ST W14 X30 PASS AISC- H1-3 0.210 8 - 0.93 C* 0.78 -163.61 41.60 37 ST W14 X30 PASS AISC- H1-3 0.182 8 0.93 C 0.78 -155.09 0.00 38 ST W14 X30 PASS AISC- H2-1 0.216 8 0.17 T 1.54 186.76 0.00 39 ST W14 X30 PASS AISC= H2-1 0.220 8 0.17 T 0.22 -180.65 41.60 40 ST W14 X30 PASS AISC- H2=1 0.216 8 0.17 T -1.57 -186.30 93.60 ************** END OF TABULATED RESULT OF DESIGN ************** 207. LOAD LIST 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 208. PARAMETER 209. CODE AISC 210: FYLD 42. MEMB 3 TO 9 12 TO 18 211. FYLD 36. MEMB 1 2 10 11 19 TO 22 31 TO 40 212. RATIO 1.33 MEMB 1 TO 22 31 TO 40 213. BEAM 1. MEMB 1 TO 22 31 TO 40 214: CHECK CODE MEMB 1 TO 22 31 TO 40 WEIBEL RESIDENCE MOMENT FRAME STAAD-III CODE CHECKING - (AISC) -- PAGE NO. .1 7,1 User ID: R.C.E. ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL GOND/ RATIO/. LOADING/ ------------------------------------------------------------------------ ----------------------------------------------------------------------- FX MY MZ LOCATION 1 ST W12 X65 PASS AISC- H1-3 0.596 16 21.03 C 140.99 744.69 144.00 2 ST W12 X65 PASS AISC- H1-3 0.606 9 14:63 C 426.11 -43.67 144.00 3 ST TUB 60604 PASS AISC- H1-3 0.327 9 5.51 C 18.04 52.35 144.00 4 ST TUB 60604 : PASS AISC- H1-3 0.538 13 2.59 C 70.16 60.99 0.00 5 ST TUB 60604 a PASS AISC- H1-3 0.309 13 2.19 C -6.96 66.83 130.80 6 ST TUB 60604 . PASS AISC- H2-1 0.369 15 3.59 T -39.52 -47.91 108.06 7 ST TUB 60604 PASS AISC- H1-3 0.338 9 0.71 C -4.55 80.03 0.00 8 ST TUB 60604 PASS AISC- H1-3 0.250 13 0.29 C 8.67 54.23 0.00 9 ST TUB 60604 PASS AISC- H1-3 0.244 13 1.19 C -0.79 58.90 0.00 10 ST W12 X65 PASS AISC- H1-3 0.648 12 23.48 C -133.15 859.85 144.00 11 ST W12 X65 PASS AISC- H1-3 0.649 1 11 26.05 C -138.54 -833.85 144.00 12 ST TUB 60604 :PASS AISC- H1-3 0.326 10 5.63 C -51.98 -17.92 144.00 13 ST TUB 60604 PASS AISC- H1-3 0.546 14 2.21 C -60.76 -73.36 0.00 14 ST TUB 60604. PASS AISC- H1-3 0.332 14 2.38 C -69.79 9.39 130.80 15 ST TUB 60604 PASS AISC- H2-1 0.381 15 3.58 T 40.92 -49.60 108.06 16 ST TUB 60604' PASS AISC-'H1-3 0.339 10 0.72 C 1 4.86 79.90 0.00 17 ST TUB 60604 PASS AISC- H2-1 0.248 14 0.64 T -9.06 52.86 0.00 18 ST TUB 60604 PASS AISC- H1-3 0.265 14 0.30 C 1.04 65.74 0.00 19 ST W14 X30 PASS AISC- H2-1 0.840 16 1.07 T -13.95 744.70 0.00 20 ST W14 X30 PASS AISC- H1-3 0.821 15 2.42 C 10.98 -735.67 66.00 21 ST W14 X30 PASS AISC- H2-1 0.904 12 4.80 T -2.87 859.84 0.00 WEIBEL RESIDENCE MOMENT FRAME ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) -- PAGE NO.. p Z7, User ID: R.C.E. MEMBER_ TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ ----------------------------------------------------------------------- ----------------------------------------------------------------------- FX MY MZ LOCATION 22 ST W14•X30 PASS AISC- H1-3• 0.920 11 6.15 C 5.65 -846.66 66.00 31 ST W8X 28 PASS AISC- H1-3 0.030 15 2.73 C 0.00 -7.36 31.50 32 ST W8X 28 PASS AISC- H1-3 0.217 15 2.95 C 0.00 =101.09 72.00 33 ST W8X 2.8 PASS AISC- H1-3 0.030 15 2.77 C 0.00 -7.36 31.50 34 ST W8X 28 PASS AISC- H1-3 0.229 15 2.98 C 0.00 -107.14 72.00 35 ST W14 X30 PASS AISC- H2-1 0.484 10 0.75 T -7.16 394.68 0.00 36 ST W14 X30 PASS AISC- H1-3 0.342 9 2.63 C -0.38 -264.16 0.00 37 ST W14 X30 PASS AISC- H1-3 0.495 9 2.63 C 6.87 -394.12 93.60 38 ST W14 X30 PASS AISC- H2-1 0.567 14 0.48 T -8.82 461.85 0.00' 39 ST W14 X30 PASS AISC- H1-3 0.382 9 1.35 C 0.09 -306.42 0.00 40 ST W14 X30 PASS AISC- H1-3 0.569 13 0.81 C 8.82 -460.82 93.60 ************** END OF TABULATED RESULT OF DESIGN ************** 215. LOAD LIST 25 26 27 28 29 30 31 32 33 34 35 36 216. PARAMETER 217. CODE AISC 218. FYLD 42. MEMB 3 TO 9 12 TO 18 219. FYLD 36. MEMB 1 2 10 11 19 TO 22 37. TO 40 220. RATIO 1.33 MEMB 1 TO 22 31 TO 40 221.:BEAM 1. MEMB'l TO 22 31 TO 40 222. CHECK CODE MEMB 1 TO 3 10 TO 12 WEIBEL RESIDENCE MOMENT FRAME -- PAGE NO. X23 User ID: R.C.E. STAAD-III CODE CHECKING - (AISC) ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION 1 ST W12 X65,. PASS AISC- H1-3 1.126 31 37.14 C 204.60 1587.23• 144.00 2 ST. W12 X65 PASS AISC- H1-3 1.156 29' 40.07 C 256.54 -1494.99 144.00 3 ST TUB 60604 PASS AISC- H1-3 0.619 30 7.37 C 72.86 -67.47 144.00 10 ST' W12 X65 PASS AISC- H1-3 1.198 32 41.20 C -191.63 1748.07 144.00 11 ST' W12 X65 PASS AISC- H1-3 1.237 30 43.93 C -249.97 -1658.70 144.00 12 ST TUB 60604 PASS AISC- H1-3 0.654 29 7.23�C 75:90 -73.84 144.00 END OF TABULATED RESULT OF DESIGN ************** 223. LOAD LIST 1 2 3 8 224. PARAMETER 225. CODE TIMBER 226. BEAM 1. MEMB 24 25 27 TO 29 47 TO 49 221. GLULAM 1:24F-V4-DF/DF MEMB 24 25 27 TO 29 47 TO 49 228. LZ 2:4. MEMB 24 25 27 TO 29 229. CHECK CODE MEMB 24 25 27 TO 29 47 TO 49 WEIBEL RESIDENCE MOMENT FRAME STAAD-III CODE CHECKING - (AITC) +++++++++++++++++++++++ ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) -- PAGE NO. ;x.L� User ID: R.C.E. MEMBER TABLE RESULT/ , CRITICAL COND/ .' RATIO/ LOADING/ FX MY MZ LOCATION ----------------------------------------------------------------------- ----------------------------------------------------------------------- 24 PR 5.125X18.000 PASS TCM:CL. 5-18 0.062 8 0.77 C 0.00 26.12 103.3597 --------------------------------------------------------------------------� MEMB- 24 GLULAM GRADE:24F-V4-DF/DF LAM.=1.500 UNITS: POUND -INCH LZ= 24.00 LY=177.19 LUZ=177.19 LUY=177.19 JZ =0.000 JY =1.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1:00 CFZ=0.96 CFY=1.00 CLZ=0.990 CLY=1.000 ACTUAL STRESSES: fa= 8.33,fbz= 94.39,fby= 0.0l,fvz= 12.26,fvy= 0.00 ALLOW. STRESSES: FA= 401.57,FBZ=2302.60,FBY=1500.00,FVZ=165.00,FVY=145.00 --------------------------------------------------------------------------� 25 PR 5.125X18.000 PASS TCM:CL. 5-18 0.062 8 0.77 C 0.00 26.12 103.3597 --------------------------------------------------------------------------� MEMB- 25 GLULAM GRADE:24F-V4-DF/DF LAM.=1.500 UNITS:. POUND -INCH LZ= 24.00 LY=177.19 LUZ=177.19 LUY=177.19 JZ =0.000 JY =1.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1.00 CFZ=0.96 CFY=1.00 CLZ=0.990 CLY=1.000 JACTUAL.STRESSES: fa= 8.33,fbz= 94.39,fby= 0.0l,fvz= 12.26,fvy= 0.00 ALLOW, STRESSES: FA= 401.57,FBZ=2302.60,FBY=1500.00,FVZ=165.00,FVY=145.00 ----------------------------------------------------------------------- --� 27 PR 5..125X18.000 PASS TCM:CL. 5-42 0.044 8 •0.93 T 0.00 22.09 95.9217 -------------------------------------------------------------------------- MEMB- 27 GLULAM GRADE':24F-V4-DF/DF LAM.=1.500 UNITS: POUND -INCH LZ= 24.00 LY=164.44 LUZ=164.44 LUY=164.44 JZ =0.000 JY =1.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1.00 CFZ=0.96 CFY=1.00 CLZ=0.991 CLY=1.000 ACTUAL STRESSES: fa= 10.07,fbz= 79.82,fby= 0.00,fvz= 11.27,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2304.34,FBY=1500.00,FVZ=165.00,FVY=145.00 ----------------------------------------------------------------- J WEIBEL RESIDENCE MOMENT FRAME ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) -- PAGE NO. 3YZ7 User ID: R.C.E. .MEMBER TABLE RESULT/ CRITICAL GOND/ RATIO/ LOADING/ FX MY MZ LOCATION - ------------------------------------------------------------------------ --------------------------------------------------------------------- 28 PR 5.125X18.000 PASS TCM:CL. 5-40 0.624 8 0.00 0.00 392.88 156.0000 --------------------------------------------------------------------------� MEMB- 28 GLULAM GRA1)E:24F-V4-DF/DF LAM.=1.500 UNITS: POUND -INCH LZ= 24.00 LY=156.00 LUZ=156.00 LUY=156.00 JZ =0.000 JY =1.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1.00 CFZ=0.96 CFY=1.00 CLZ=0.992 CLY=1.000 ACTUAL STRESSES: fa= 0.00,fbz=1419.62,fby= 0.00,fvz= 43.66,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2294.28,FBY=1500.00,FVZ=165.00,FVY=145.00 j--------------------------------------------------------------------------� 29 PR 5.125X18.000 PASS TCM:CL. 5-18 0.619 8 0.00 0.00 392.88 156.0000 --------------------------------------------------------------------------� MEMB- 29 GLULAM GRADE:24F7V4-DF/DF LAM.=1.500 UNITS: POUND -INCH LZ= 24.00 LY=156.00 LUZ=156.00 LUY=156.00 JZ =0.000 JY =1.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1.00 CFZ=0.96 CFY=1.00 CLZ=0.992 CLY=1.000 ACTUAL STRESSES: fa= 0.00,'fbz=1419.62,fby 0.00,fvz= 43.66,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2294.28,FBY=1500.00,FVZ=165.00,FVY=145.00 'I--------------------------------------------------------------------------� 47 PR 5.125X18.000 PASS TCM:CL. S-42 0.010 8 0.03 T 0.00 6.17 0.0000 --------------------------------------------------------------------- - - - - - � MEMB- 47 GLULAM GRADE:24F-V4-DF/DF LAM.=1.500 UNITS': POUND -INCH' LZ= 54.52 LY= 54.52 LUZ= 54.52 LUY= 54.52 JZ =0.000 JY =0.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1.00 CFZ=0.96 CFY=1.00 CLZ=1.000 CLY=1.000 ACTUAL STRESSES: fa= 0.37,fbz= 22.29,fby= 0.00,fvz= 4.62,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2294.65,FBY=1500.00,FVZ=165.00,FVY=145.00 -------------------------------------------------------------------------- � ✓, WEIBEL RESIDENCE MOMENT FRAME -- PAGE NO. ;-"z User ID: R.C.E. ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL GOND/ RATIO/ LOADING/ FX MY MZ LOCATION ----------------- 48 PR 5.125X18.000 PASS TCM:CL. 5-42 0.010 8 0.03 T 0.00 6.17 0.0000 -----------------------------------------------------------------------••--� MEMB- 48 GLULAM GRADE:24F-V4-DF/DF LAM.=1.500 UNITS: POUND -INCH / LZ= 54.52 LY= 54.52 LUZ= 54.52 LUY= 54.52 JZ =0.000 JY =0.000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=1..00 CFZ=0.96 CFY=1.00 CLZ=1.000 CLY=1.000 ACTUAL STRESSES: fa= 0.37,fbz= 22.29,fby= 0.00,fvz= 4.62,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2294.65,FBY=1500.00,FVZ=165.00,FVY=145.00 --------------------------------------------------------------------------� 49 PR 5.125X18.000 PASS TCM:CL. 5-42" 0.010 8 0.03 T 0.00 6.17 0.0000 --------------------------------------------------------------------------� MEMB- 49 GLULAM GRADE:24F-V4-DF/DF LAM.=1.500 UNITS: POUND -INCH LZ= 54.52 LY= 54.52 LUZ= 54.52 LUY= 54.52 JZ =0.000 JY =0:000 CDT=1.000 CSF=1.00 WET=0.0 CCR=1.00 CTM=I.00 CFZ=0.96 CFY=1.00CLZ=1.000 CLY=1.000 ACTUAL STRESSES: fa= 0.37,fbz= 22.29,fby= 0.00,fvz= 4.62,fvy= 0.00 ALLOW. STRESSES: FA=1150.00,FBZ=2294.65,FBY=1500.00,FVZ=165.00,FVY=145.00 --------------------------------------------------------------------------� 230. FINISH +++++++++++++++ END OF STAAD-III +++++++++++++++ **** DATE= SEP 6,1995 TIME= 6:11: 8 **** +++++++++++++++++++++++++++++++++++++++++++++++++++++++++ * For questions on STAAD-III/ISDS, contact: * RESEARCH ENGINEERS, Inc at * Ph: (714) 974-2500 Fax: (714) 921-2543 N iD N m N m N r w O A r D � N P N m n n - A r D m O N N C c d U C A = a P O N W O N v W n O N m T < Z n n O N N C N U C N Z 3 P O O O D P D A T x D a N Z U I I O O P N - N n N N O U C N O O N S U n r c J LL Z I 6 � U U O J J I m P d O P 11 O N O N O m Z 2 O - Z Z < O LL LL LL � J s > Y O N N N 6 U N N N N N I N N • O O N N > N U J U LL U LL N O m P d O 4 N O O a N O - Z Z < - •C J - - U O j N H m P O n O v P O I U N O � W i c Z � � a U a' P�•3\ P m 'P O N d m n P O 0 m 0 O I O N O ry P O = v N m 4 L Z p � U u O J P m 'P O N d m n 846.66 670.23 STEEL DESIGN PEP FOP MEM9EP• 22 AISC-89 2P X 5, Vt.— B 2 L 66.OP tM Bet.• P STPESSES (XIP. INCH) VLD• 36.00 FA• 1B.83 FCZ- 23.76 FT2. 23.76 FCv•.27.00 FTv• 27.00 FT• 21.60= FV• 14.40 DESIGN SUMMAPV- KIP,INCM P-11 PASS ' Cflticet ConO2tl01 • AISC- H,-3 Pe110 0.92 FX 4.15C nv 5.65 • MZ -846.66 Logia Locellon 66.00 Ab0 ner H191 Low MCYlmum Fo,ce/Moment Summery, U—S (INC.XIP) A-1 Sneer V Sneer• 2 MOmenl V Moment 2 vele L Deet ton• Loealn9• S T A A 0 P L 0 U E P V (QEV 20.01 OATS. SEP 6. 1995 —lE VE 19El PESIPENL6 .—T I—E ` 6.t5 15.38 0 C7 5.65 846.66 ' 66.00 66.00 66 to 66.00 66.00 S T A A 0 P L 0 U E P V (QEV 20.01 OATS. SEP 6. 1995 —lE VE 19El PESIPENL6 .—T I—E ` N O O O • N i Z Y 6 LL O 4 O LL O LL O C S W N A N N a o N U i U 4 Z u N 4 LL i W O f>y 3a N n O I N n r u LL i i Q Q f>y 3a 9 N U JI < O T O Z S Q 6 m d P l W Q O V N O d O O C 2 2 N m N O 3 O m ' N ^ Z N N � 6 Y Q LL •- LL 4 6 Y O O O S N O .p N O d L N N A ^ N N 4 WO 9 N U JI < O T O Z S Q 6 m d P l W Q O V O N N O O LL w N m N O 3 O m ' N ^ N U A m d P O O W Q O V O N , O LL b ^ J Q Q U U � J D z C O N O N O Q O C O N U N O n - � Q 6 U J 10 N N m O Z O O O I �0 � Z - N' N - d Y 6 LL y LL Q Q O O O O I N O UI d �0 O W Z H N A c N N Z �_ 0 U U 4 YI O m n C m 0' W T N _ N m NO N m O O ' 6 O � O I O' a - � U U Q 4 Z L C O J p� 3 �- L� > O' O O � O E C i n O = o N O 6 N Y U h 2 N O O O O E E H u N O O O O � d O E I E � N O O � O O E a p [ ' I J > j O O N a O W O J 6 O" Q N N N O O O Z U U N P O o Z • ' C Y O LL LL C C U U j UI O a a O P a S N Z a UIj 0 U 4 u_ N LL 4 O N n U P O P O O U N o • ' C O C U U j WEIBEL RESIDENCE MOMENT FRAME -- PAGE NO. X 3 User ID: R.C.E. REPORT: LIST SUPPORT REACTIONS., SUPPORT ----------------- REACTIONS -UNIT KIP INCH STRUCTURE TYPE = SPACE JOINT LOAD FORCE -X FORCE -Y FORCE -Z MOM -X MOM -Y MOM Z 1 1 -0.31 5.75 0.58 0.00 0.00 0.00 2 -0.65 3.09 0.11 0.00 0.00 0.00 3 0.00 1.60 0.27 0.00 0.00 0.00 4 -1.78 1.80 0.11 0.00 0.00 0.00 5 0.03 -11_80 -4.45 0.00 0.00 0.00 6 -0.98 1.12 0.14 0.00 0.00 0.00 7 0.02 -12.18 -4.48 0.00 0.00 0.00 3 1 -0.26 8.23 -0.41 0.00 0.00 0.00 2 -0.70 3.75 -0.10 0.00 0.00 0.00 3 0.03 2.21 -0.14 0.00 0.00 0.00 4 -2.00 2.65 0.21 0.00 0.00 0.00 5 -0.03 11.23 -4.43 0.00 0.00 0.00 6 -1.61 2.56 0.27 0.00 0.00 0.00 7 -0.02 11.59 -4.43 0.00 0.00 0.00 5 1 0.00 5.01 -0.01 0.00 0.00 0.00 2 0.00 0.20 -0.01 0.00 0.00 0.00 3 0.00 1.42 -0.02 0.00 0.00 0.00 4 -0.37 0.30 0.09 0.00 0.00 0.00 5 0.03 0.57 -0.19 0.00 0.00 0.00 6 -0.29 0.19 0..07 0.00 0.00 0.00 7 -0.01 0.60 -0.27 0.00 0.00 0.00 11 1 0.31 5.82 0.58 0.00 0.00. 0.00 2 0.65 3.09 0.11 0.00 0.00 0.00 3 0.00 1.60 0.27 0.00 0.00 0.00 4 -1.78 -1.85 -0.11 0.00 0.00. 0.00 5 0.03 -14.56 -5.28 0.00 .0.00 0.00 6 -0.98 -1.19 -0..15 0.00 0.00 0.00 7 0.02 -13.93 -4.97 0.00 0.00 0.00 13 1 0.26 8.29 -0.41 0.00 0.00 0.00 2 0.70 3.75 -0.10 0.00 0.00 0.00 3 -0:03 2.21 -0.14 0.00 0.00 0.00 4 -2.00 -2.48 -0:20 0.00 0.00 0.00 5 0.00 14.00 -5.28 0.00 0.00 0.00 6 -1.60 -2.31 -0.26 0.00 0.00 0.00 7 0.00 13.34 -4.94 0.00 0.00 0.00 15 1 0.00 5.01 -0.01 0.00 0.00 0.00 2 0.00 0.20 -0.01 0.00 0.00 0.00 3 0.00 1.42 -0.02 0.00 0.00 0.00 ' 4 -0.37 -0.42 -0.09 0.00 0.00 0.00 5 -0.07 0.55 -0.22. 0.00 0.00 0.00 6 -0.28 -0.37 -0.07 0.00 0.00 0.00 7 -0.01 0.59 -0.28 0.00 0.00 0.00 SPREAD FOOTING DESIGN Charles Roberts, P.E. Chico, California Date: 9-12-1995 Project: WEIBEL RES. Footing Location: JOINT.1 Comment : MATERIAL PROPERTIES n Ultimate.concrete compressive strength, f"c is 2.00 ksi Steel yield strength, Fy is 40.00 ksi Concrete is Hardrock with a"unit weight of 150.00.pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is -1.50 ksf (3311 short term increase allowed) LOAD.CASES CONSIDERED ARE: 1.4DL + 1.7LL 1 .4 (DL + LL + EQ) .75(1.4DL + 1.7LL + 1.7W) .9DL - 1.3W .75(1.4DL + 1.7LL + 1.87EQ) .9DL - 1.4EQ UNFACTORED INPUT LOADS P (kips) DL 5.75 LL: 4.69 EQ. 12.18 WIND 11.80 FOOTING PERAMETERS M (ft -kips) 0.00 0.00 0.00 0.00 Dimensions are 5.00 Ft. Sq. Total depth is 24.00 Inches / Depth "d" is 20.00 Inches Col size is 12.00,x 12.00 In. REQUIRED REINFORCEMENT bottom.long. 0..28 Sq.In. bottom trans. 0.30 Sq.In. STRESSES AND SOIL BEARING Max. punching shear stress is 10.95 psi Max. beam shear stress is 1.76 psi Gravity only soil bearing is 0.52 ksf Gravity+lat. soil bearing is 1.00 ksf SPREAD FOOTING,DESIGN Charles Roberts, P.E. Chico, California Date: 9-12-1995 Project: WEIBEL RES. Footing Location: JOINT 3 Comment : MATERIAL PROPERTIES Ultimate concrete compressive strength, f"c is 2.00 ksi Steel yield strength, Fy is 40.00 ksi Concrete is Hardrock with a unit weight of 150.00 pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is 1.50 ksf (33o short term.increase allowed) LOAD CASES CONSIDERED ARE: 1.4DL + 1.:7LL 1.4(DL + LL + EQ) .75(1.4DL + 1.7LL + 1.7W) .9DL -.1-3W .75(1.4DL + 1.7LL + 1.87EQ) .9DL - i.4EQ UNFACTORED INPUT LOADS P (kips) M (ft -kips) DL 8.23 0.00 LL 5.96 0.00 EQ 11.59 0.00 WIND 11.23 0.00 FOOTING PERAMETERS Dimensions are 4.00 Ft. Sq. Total depth is 24.00 Inches Depth "d" is 20.00 Inches Col size is 12.00'x 12.00 In. REQUIRED REINFORCEMENT bottom.long. 0.23 Sq.In. bottom trans. 0.24 Sq.In. STRESSES AND SOIL BEARING Max. punching shear stress is 8.87 psi Max. beam shear stress is 0.00 psi Gravity only soil bearing is 0.99 ksf Gravity+lat. soil bearing is 1.71 ksf J SPREAD FOOTING DESIGN Charles Roberts, P.E. Chico, California Date: 9-12-1995 Project: WEIBEL RES. Footing Location: JOINT 5 Comment : MATERIAL PROPERTIES r,� 4 2 Ultimate concrete compressive strength, f"c is 2.00 ksi Steel yield strength., Fy is 40.00 ksi Concrete is Hardrock with a unit weight of 150.00 pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is 1.50 ksf (33% short term increase allowed). LOAD CASES CONSIDERED.ARE: 1.4DL + 1.7LL 1. 4 (DL + LL + EQ) .75(1.4DL +. 1.7LL + 1.7W) .9DL - 1.3W .75(1.4DL + 1.7LL + 1.87EQ) .9DL - 1.4EQ UNFACTORED INPUT LOADS P (kips) M (ft -kips) DL 5.01 0.00 LL 1.62 0.00 EQ 0.60 0.00 WIND 0.57 0.00 FOOTING PERAMETERS Dimensions are 2.50 Ft. Sq. / Total depth is 12.00 Inches i Depth "d", is 8.00 Inches Col size is 12.00 x 12.00 In. REQUIRED REINFORCEMENT bottom long. 0.06 Sq.In.` bottom trans. 0.07 Sq.In. STRESSES AND SOIL BEARING Max. punching shear stress is 9.60 psi Max. beam shear stress is .1.41 psi Gravity only soil bearing is .1.11 ksf Gravity+lat. soil bearing is 1.21 ksf SPREAD FOOTING DESIGN P5 L 3 Charles Roberts, P.E. Chico, California Date: 9-12-1995 Project: WEIBEL RES. Footing Location: JOINT 11 Comment : MATERIAL PROPERTIES Ultimate concrete compressive strength, f"c is 2.00 ksi Steel yield strength, Fy is 40.00 ks.i Concrete is.Hardrock with a unit weight of:150.00 pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is 1.50 ksf (33o.short -.term increase allowed) LOAD CASES CONSIDERED ARE:. 1.4DL + 1.7LL 1 .4 (DL + LL + EQ) . .75(1.4DL + 1.7LL + 1.7W) .9DL - 1.3W .75(1.4DL + 1.7LL + 1.87EQ) .9DL - 1.4EQ UNFACTORED INPUT LOADS P (kips) M (ft -kips) DL 5.82 0.00 LL 4.69 0.00 EQ 13.93 0.00 WIND 14.56 0.00 FOOTING PERAMETERS Dimensions are 5.00 Ft. Sq.' -,// Total depth is 30.00 Inches Depth "d" is 26.00 Inches Col size is 12.00 x 12.00 In. REQUIRED REINFORCEMENT bottom long. 0.23 Sq.'In. bottom trans. 0.24 Sq.In. STRESSES AND SOIL BEARING Max. punching shear stress is 6.61 psi Max. beam shear stress is. 0.00 psi Gravity only soil bearing. is 0.55 ksf Gravity+lat. soil bearing is .1.13 ksf SPREAD FOOTING DESIGN �� H Z4 Charles Roberts, P.E. Chico, California bate: 9-12-1995 Project: WEIBEL RES... Footing Location: JOINT 13 Comment : MATERIAL PROPERTIES Ultimate concrete compressive strength, f"c is 2.00 ksi Steel yield strength, Fy is 40.00 ksi- Concrete is Hardrock with a unit weight of 150.00 pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is 1.50 ksf (33% short term increase allowed) LOAD CASES CONSIDERED.ARE: 1.4DL + 1.7LL 1.4(DL + LL + EQ) .75(1_.4DL + 1.7LL + 1.7W) .9DL - 1.3W .75(1.4DL + 1.7LL + 1.87EQ). .9DL - 1.4EQ UNFACTORED INPUT LOADS P '(kips) M (ft -kips) DL 8.29 0.-00 LL 5.96. 0.00 EQ 13.34 0.00 WIND 14.00 0.00 FOOTING PERAMETERS Dimensions are 4.00 Ft. Sq. Total depth is 30.00.Inches Depth "d" is 26.00 Inches Col size is 12.00 x 12.00 In. REQUIRED REINFORCEMENT . bottom long. 0.19 Sq.In. bottom trans. 0.19 Sq.In. STRESSES AND SOIL BEARING Max. punching shear stress is 4.21 psi Max. beam shear stress is 0.00 psi Gravity only soil bearing is 1:02 ksf Gravity+lat. soil bearing is 1.89 ksf SPREAD FOOTING DESIGN Charles Roberts, P.E. Chico, California Date: 9-12-1995 Project: WEIBEL RES. Footing Location: JOINT 15 Comment . MATERIAL PROPERTIES P5 4-5 Ultimate concrete compressive strength, f"c is 2.00 ksi Steel yield strength, Fy is 40.00.ksi Concrete is Hardrock with a unit weight of 150.00 pcf Concrete weight for soil bearing is 50.00 pcf Max. soil bearing is 1.50 ksf (3:3% short term increase allowed) LOAD CASES CONSIDERED ARE: 1.4DL + 1.7LL 1.4(DL + LL + EQ) .75(1.4DL + 1.7LL + 1.7W) .9DL - 1.3W .75(1.4DL + 1.7LL + 1.87EQ) .9DL. - 1.4EQ UNFACTORED INPUT LOADS P (kips) DL 5.01 LL 1.62 EQ 0.59 WIND 0.55 FOOTING PERAMETERS M (ft -kips), 0.00 0.00 0.00 0.00 STRESSES AND SOIL BEARING Dimensions are 2.50 Ft. Sq. Max. punching shear stress is stress is 9.59 1.40 psi psi Total depth is 12.00 Inches Max. beam shear Gravity only soil bearing is 1.11 ksf Depth "d" is 8.00 Inches Gravity+lat. soil bearing is 1.21 ksf Col size is 12.00 x Zinc In. REQUIRED REINFORCEMENT bottom long. 0.06 Sq.In. bottom trans. 0.07 Sq.In.