Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
068-210-109
I MINOR USE PERMIT 96-01 A..P.#068-210-109 1/ , � > Lloyd Hansen (,a-2 21 Buehler Ave., Oroville Permit #606 79B, ,E,,��M(add bedroom & bath/SF) �� �s-z�- }it ��6327-79B,E(neW pri.det. Y gaaakrge) l7_'— Permit#4656 80P(plbg/6327-79 (gar. Permit# 79) Permit #6132-80Bdition Zo ` garage) .� �� t Permit # 2846-82B(2nd%rrnewal/6368-21:27-79) } I LONG, Harold 3999H *46648 21 Buehler Ave., Orovi lP CONTR: West Coast Home Products, Inc., 815 So. Fremont Ave., Alhambra (repairs)(alum. sidi_g) *(Type A Flue) 068-210-109 00-1197 �j HANSEN, LLOYD -7-ee' $1 BUEHLER AVE., OROVILLE CONTR: OWNER cil-g" 0 ROOM ADDITION, & RE -ROOF T068-210-109 00-3010 HANSEN, LLOYD r_�f 1/t 4 21 BUEHLER OROVILLE CONTR: OWNER / 68 -21 -4w -;r GAS HEATER & HVAC V Permit # 2847-/�B(�lst renew/6132-80) 68-21-1 068-210-109 01-1110 Permit#474=84B(2nd & 3rd ren/6132-80) HANSEN, LLOYD (� 68-21-t5 27 BUCHLER AVE., OROVILL JC Permit 47' & 4th renewal/6327- CONTR: OWNER I 79 &add ele ser/SF) NEW 200 AMP SERVICE /, 68-21-4a7- rmit#9-85B(4th renewal/6132-80) 68-21- -?'AA.JQ- rmit#2550-87P(gas line/s op)'`�A 068-210-109 PERMIT#97-140 HANSEN, Lloyd &Max' 23 Buehler Ave., roville Conv Port Gar e to 2nd Dwelling & Add'1 Sq F 068-21)-109 05-0426, HANSEN, LLOYD 21 BUEHLER AVE, OROVILLE Cont: OWNER NEW PRI DET GARAGE PERMT DATE: l0 BP#_A,`)G EXPIRES: IZZ AL BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 PERMIT NO. PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE, OR IF WORK IS DONE IN VIOLATION OF ANY COUNTY OR STATE LAWS. LICENSED CONTRACTORS DECLARATION _ I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 05/31/2005 APN: 068-210-109-000 the Business and Professions Code, and my license is in full force and effect. License Class : License Number: Site Address: 23 BUEHLER AVE ORO Date: • Contractor OWNER -BUILDER DECLARATION I hereby affirm under penally of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): l� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and • the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). Map Index: Description: GAR(1568) Owner: HANSEN LLOYD O & MAXINE B 21 BUEHLER AVE OROVILLE, CA 95965 Applicant: HANSEN LLOYD O & MAXINE B 21 BUEHLER AVE OROVILLE, CA 95965 .❑ I, as owner of the property, am exclusively contracting with licensed contractors. to construct the project (Sec. 7044, Business and Professions Code. The Contractors' Slate License Law does not apply to an owner of property who builds or Improves thereon, Contractor: and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I am Exempt under Article 3 t 9 Busi ess nd Professions Code Date:,�'yOwner:� /t WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -Insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: License #: Architect: Engineer: Carrier: Total Square Ft: 1568 S.F. Policy #: Valuation: $37,632.00 Ud I certify that in the performance of the work for which this permit is Census Code: issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' �-27compensation provisions of Section 3700 of the Labor Code, I shallforthwith comply with those provisions.[� Date: Applicant: WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided'for in Section 3700 of the Labor code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Clv.) Name: Address: This permit is h y issue under the app' provisions of the Butte County Code and/or Resolutions do work in bove fo which es have been paid. By: Date: PERMIT EXPIRES ON: 5, ._ 31-06 ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. GI , Notification in accordance with Section 17J827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with ,all county and state laws relating to building construction. I acknowledge it Is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte County to enter upon the above mentioned property for Inspection purpose,¢. Print Name: 1—I0X1d /M IV .55" Signature Date: 4Owner ❑ Contractor ❑ Agent for Owner ❑ Agent for Contractor O y._ _ '_ e O BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS 24 HOUR INSPECTION#: OROVILLE: (530) 538-7636 • CHICO: (530) 891-2834 1� / OFFICE #: (530) 538-7541 b A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds �] **PLEASE PRINT CLEARLY** OWNER Last Name s irst lme L O yd Address 11 L riz 'I l/ City StateG ZiPGISQ 66 Phone6 3_ �p Fax E-mail Name CONTRACTOR Name State Address Phone City Zip State Zip Phone E-mail Fax E-mail Lot # Lic. # Class Name ARCHITECT/ENGINEER Address State City Phone State Zip Phone Fax E-mail Boo State License Number APPLICANT NAME Name Address City State Zip Phone Fax E-mail APPLICANT SIGNATURE For office use only: LOCATION Zoning L17 Flood Zone G C v,[:--56t1l111= SRA es No Occ. Type Const. bdivision Nam W4Map Boo Page Lot # I nner ril R DWp roved: S 7-06 NO. BP t''d q BIN # OVER FOR/SUBMITTAL REQUIREMENTS K:\FORMS\BUILdING FORMS\BldgApplSubRgmts.doc Page 1 of 2 c esc 'ptio or o of ork: Sq. Footage ` 16 6 ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be required. REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Received bvt It * Amount: 35 /. Receipt #: 14/ g �% 3 Date: DV I t U SRA Sheriff SMIP Other 557.9a Total REV 7-27-04 LOCATION AP# L17 Property Address l !�U G C v,[:--56t1l111= C'ty Cross Street AA 9 aZ- WORKER'S COMPENSATION Policy Number �f 2 Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address OVER FOR/SUBMITTAL REQUIREMENTS K:\FORMS\BUILdING FORMS\BldgApplSubRgmts.doc Page 1 of 2 c esc 'ptio or o of ork: Sq. Footage ` 16 6 ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be required. REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Received bvt It * Amount: 35 /. Receipt #: 14/ g �% 3 Date: DV I t U SRA Sheriff SMIP Other 557.9a Total REV 7-27-04 SUBMITTAL & PERMIT REQUIREMENTS The following drawings and specifications must be submitted to the Building Division in order to apply for a permit. INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ALL PLANS MUST BE LEGIBLE AND IN INK. ❑ 1. Site plans,.3 or 4 sets, signed by the preparer of the plans. No graph paper! ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans (No graph paper!) OR Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 3. Engineered truss details and layouts in duplicate (if required). No faxes! ❑ 4. Energy compliance design and supporting documentation in duplicate. (Note: Not required for additions to mobile or modular homes.) ❑ 5. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 6. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 7. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate (if required). ❑ 9. Site plan and business license approval from the City of Biggs. ❑ 10. Letter of intent for non-residential buildings. ❑ 11. Detached Accessory Building Form filled out by the owner (if required). ❑ 12. Hazardous Material Form (for Commercial Buildings only). ❑ 13. Sanitation and site plan approval from the Environmental Health Department. Remaining items needed to issue -the permit. Additional items may be required after Plan Check and Planning review (May require additional plan review upon receipt of the following items.) ❑ 1. Agricultural Buffer clearance and site plan approval from the Ag Commissioner's office (if required). ❑ 2. Impact Fees. ❑ 3. California Department of Forestry plan approval (if required). ❑ 4. NPDES Form. ❑ 5. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 6. Contractor's license information. (Number, Name Style, Classification). ❑ 7. Worker's Compensation Carrier and Policy Number. ❑ 8. Owner -Builder Verification (if required). ❑ 9. Letter of Signature authorization (if required). ❑ 10. Recorded copy of Agricultural Acknowledgment Statement. ❑ 11. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner (for 433A's). If you have questions or would like additional information regarding this process, contact a Permit Application Assistant at (530)538-7541. EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after date of application. In order to renew action on an application after expiration, a new application, plans and fees will be required. REQUEST FOR FEE REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made within two years from the date of fee payment on permits not issued, and two years from the date issued; however, on issued permits refunds can only be made if no construction work has check fees for work plan checked and other department costs are not refundable. OVER FOR BUILDING PERMIT APPLICATION of permit issuance for permits been done. Filing fees, plan KAFORMS\BUILDING F0RMS\B1dgApp1SubRgmts.doc Page 2 of 2 REV 7-27-04 utte County Department of Development Services ANNE CHRISTOPHER, DIRECTOR WILLDAN Scott Rutherford (530) 538-7160 srutherford@buttecounty.net Plans Transmittal For Review Per Contract 2/14/2005 Applicant: 111ansen, Lloyd I Permit No: 05-0426 Project Type: Detached Gar I APN: 068-210-109 100% 70% Plan Check Fees $ 351.94 $ 246.36 $ 351.94 $ 246.36 WILLDAN Fee $ 246.36 Copies Attached: Qty Chk Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other 7 County Center Drive N Oroville, CA 95965 (530) 538.7601 Telephone (530) 538.7785 Facsimile O TO: FROM: ' LO SUBJECT: O z DATE: WILLDAN Scott Rutherford (530) 538-7160 srutherford@buttecounty.net Plans Transmittal For Review Per Contract 2/14/2005 Applicant: 111ansen, Lloyd I Permit No: 05-0426 Project Type: Detached Gar I APN: 068-210-109 100% 70% Plan Check Fees $ 351.94 $ 246.36 $ 351.94 $ 246.36 WILLDAN Fee $ 246.36 Copies Attached: Qty Chk Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: 41ASSESSOR PARCEL NUMBER 0t,C�(J,f( -,.l Q - D-�% Proposed Building Use: Counter Technici Date: (I /0� Items required in order to ply fora Permit. All boxes MUST be checked OR marked NA in order fo apply. / 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Letter from Engineer or Architect for truss design review. ❑ 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and talcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate ❑ 11. Site plan and business license approval from the City of Biggs ❑ 12. Letter of intent for non-residential buildings ❑ 13. Detached Accessory Building Form filled out by the owner ❑ 14. Hazardous Material Form �^ 15. Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable. 16. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ❑ 17. Fire Sprinklers............................................................................................ ❑ 18. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 19. Soils Report and/or Engineered Foundation required ........................................... ........ ❑ 20. Erosion Control Plan Required........................................................................ ........ 9--" of Fees as shown on the attached Schedule of Fees Due Sheet .............................. ❑ 22. City of Chico Plumbing permit........................................................................ 23. California Department of Fores y plan approval aid. Sent by: ........... 24 Planning approval (A) Use:(B)Parking: (C) Parcel Check:_ Contact Land Development about -Improvements, -Drainage ......................... 26. NPDES Form............................................................................................. ❑ 27. Encroachment Permit for driveway from the Public Works Dept ........................... ❑ 28. Pre -Inspection for required....... ❑ 29. Contractor's license information. (Number, Name Style, Classification) ................... ❑ 30. Worker's Compensation Carrier and Policy Number .......................................... ❑ 31. Owner-Buiider Verification (_ Given to owner, _Mailed to owner) ..................... ❑ 32. Letter of Signature authorization.................................................................... ❑ 33. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 34. Manufactured home utility clearance............................................................... ❑ 35. Existing violations and/or expired permits......................................................... ❑ 36. Deed Restriction......................................................................................... ❑ 37. ❑ Grant Deed, ❑ M.H. TitlelStatement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 38. Other: ❑ 39. Other: When issued Telephone f� and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: t Date: - / 1. Index permit application for the above items numbered: e% Plan Check -Letter' 2. Additional items required Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ Nil, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: Date: Plans approved by: Date: Structural reviewed by: Date: Structural approved by: Date: �Note transfer by: C��-Date: 0. Yellow: Building Division E.H. use ONLY Fiat Pion Anachad Plcas P9®n Atwshad sant to G.O. ! TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public '✓ PrivateWell Clearance for dwelling. Other �8 '"�� Z,0 -i;4 'd .If PLvn-7 i3 i.v 9 Hold final for: Final clearance O.K. for: NOTE: n mental Health S"ialist 8/96 Date COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE OWNER PROPOSED BUILDING USE 1. BUILDING PERMIT FEES �� ! --Balance Due ........................................................ $ --Additional Fees Due ............................................ $ --Additional Fees Due ............................................ $ --Revised Plan Checking Fee ................................. $ 2. SCHOOL DISTRICT FEES (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential .................................... x $360.00 = $ Units Commercial (sq. ft.) ...................... x $0.03 = $ Sq. ft. 4. URBAN AREA FEES Residential ............................ x = $ # Units Amt. Commercial (Sq. ft.) ............. x = $ Sq. ft. Amt. 5. RECREATION DISTRICT FEES 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) fA 7. SRA FIRE INSPECTION AND PLAN CHECK $l(paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) A.P. # DATE RECEIPT # DATE REC. C/ �o778 5 3 /-6 �_ CSA 87 TRAFFIC FEE $2500.00 (paid at Building Divi .'on) c� 10. OTHER � a, L (o At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Building Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 6/00) p�QPRTMENT Cc ��vTrF °o/ , O° a o ° ° ��� 5 AUC WORD Department .0 o u n t Michael Crump, Director Public f B u t Works LAND DEVELOPMENT DIVISION Storm Water Management Program 7 County Center Drive Oroville. CA 95965 (530) 538-7266 (FAX) 538-7171 National Pollutant Discharge Elimination System (NPDES) Phase 11 Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement rLESS THAN I ACRE1 Project Description: 'Project Location and/or Parcel Number: _ Ayj/ By signing below, I, the project owner/owner's agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I, therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site build -outs of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. - I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions provided by law. Signed: Title: Date: 0 ,.5 - Less than I Acre NPDES & SWPPP Compliance Certification Butte County Storm Water Management Program Revised 5/24/04 ict; R� J �. i't ���. '<<•>.��1=.'}.t �,ti � , �� �j:5 :._t •.iv=�. '•£: lei ,}� ��,i x 4�' O r2BIiMRIiGIViNO Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. S2. 1. I personally plan to provide the major labor and material for construction of this proposed property improvement: YES [NO [ ]. 1 HAVE [HAVE NOT [ ] signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise, and provide the major work: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: S. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS SIGNED: PROPERTY OWNER: DATE: t- - ) l - 0 PHONE . . TYPE OF WORK NOTE: This Owner -Builder verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. Rev'd 11/4/2004 Butte County Department of Development Services ADMINISTRATION ` BUILDING k GIS ` PLANNING 7 County Center Drive Oroville, CA 95965 (530) 538-7541 Telephone (530) 538-2140 Facsimile Dear Property Owner: - An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other thanyourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that your plan to subcontract, you should be aware of the following information for your benefit and protection: o If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. o If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment compensation contributions. o There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. o For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "owner -builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification from so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Kv__� Mic el C. Vieiri C.B.O. Mallager, Building Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. ' W1 LLDAN Serving Public Agencies May 20, 2005 Scott Rutherford Butte County Building Department 7 County Center Drive Oroville, CA 95965 (530) 538-7169 (530) 538-2140 FAX SUBJECT: COUNTY OF BUTTE PLAN REVIEW APPROVAL Willdan Project No: 14353-1443-M Jurisdiction Job No: 05-0426 Assessor's Parcel No: 068-210-109 Description: . Hansen Detached Garage Dear Mr. Rutherford: 117 C Street Marysville, California 95901 530/749.2373 fax 530/749.2199 www.wilidan.com Willdan has completed a plan review of submitted plans and documents for the above referenced project and recommends your approval with the conditions noted on the 2"d page of this letter. The plans and documents provided for this review that have been found in compliance with the applicable codes are: ➢ Plans: Two (2) copies sheets 1 through 9, by Lloyd Hansen. ➢ Truss Calculations: Two (2) copies dated 02/07/05, by Longfellow Lumber Co., Inc. The plans have been stamped with the Willdan approval stamp and dated the date of this letter. According to our previous letters relating to this project, the superseded plans and documents will be discarded within 10 days unless we receive other instructions. On the pages to follow is the identification of the codes and standards applicable to the project, a code analysis, conditions -of -approval and identification of any deferred submittals. W I LLDAN Serving Public Agencies APPLICABLE CODES Unless noted otherwise, all comments are based on requirements of the 2001 California Building Standards Code found in the California Code of Regulations, Title 24: • Part 2, known as the California Building Code and abbreviated herein as CBC • Part 3, known as the California Electrical Code and abbreviated herein as CEC • Part 4, known as the California Mechanical Code and abbreviated herein as CMC • Part 5, known as the California Plumbing Code and abbreviated herein as CPC • Part 6, known as the California Energy Code, and Energy Commission Standards, and abbreviated herein as CECS CODE ANALYSIS Our plan review revealed the following information regarding the occupancy designation, type of construction, and other pertinent features. This information is consistent with that shown on the plans and permit documentation. Specific Type of Type of Use Occupancy Construction 1" Floor 2" Floor Sprinklers Stories Sq Ft Sq Ft Total S9 Ft Garage U-1 V -N No 1 1568 NA 1568 CONDITIONS OF APPROVAL 1. Approval is contingent upon the review, requirements and approval of other departments and/or agencies that have jurisdiction over this project. 2. Revisions and/or notes as red -lined on the plans. DEFERRED SUBMITTALS Our plan review reveals no deferred submittals noted at this time. SPECIAL INSPECTION NEEDS Our plan review reveals no special inspection needs pursuant to CBC 1701. Sincerely, Michael LeBeau Plans Examiner Ce: Alice Mefford, E-mail: amefford@buttecounty.net Lloyd Hansen, 21 Buehler Ave, Oroville, CA 95966, Fax: (530) 533-6502 Page 2 of County of Butte Permit Number 05-0426 W illdan Project Number 14353-1443 a M poll LnNGFELLOW LUMBER CO. INC. Quality Truss Design • Roof & Floor Systems 89 Loren Avenue • Chico, CA 95928-7434 Phone (530) 893-0112 • (800) 678-0112 Fax (530) 893-0140 E -Mail: trusses@longf r 1 owlumber.com AR's VIILLI) MARY& LLY OFFICE Customer: LLOYD HANSEN Address: Z -20E (Rev. 3/03) 21 BUEHLER AVE OROVILLE,CA Job No: HANSEN GARAGE ENGINEER Mitek Industries, Inc.,' M i �t - ago Redong (Ray) Yu -e 7777 Greenback Lan- uite" Citrus Heights, CA 95fi=10 r, �g (916) 676-1900 o ,q APPROVED INSP_EJC--TL-Mr_WGENCY Timber Products Inspection, Inc. P.O. Box 20455 Portland, OR 97220 (503) 254-0204 a3AONddd NOISIAIG ONimine AINnoo dins D a r� Eel Symbols PLATE LOCATION AND ORIENTATION 3 *Center plate on joint unless x, y /4 offsets are indicated. Dimensions are in ft -in -sixteenths. Apply plates to both sides of truss _t� and securely seat. 0 -'/1G. 0 O 'For 4 x 2 orientation, locate U U plates 0-'a6' from outside a- edge of truss. 'This symbol indicates the ._ required direction of slots in connector plates. Plate location details available In MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 x 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING ZNSI/TPI1 „SSB -89: $11: Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. rds: National Design Specification for Metal Plate Connected Wood Truss Construction. Design Standard for Bracing. Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft -in -sixteenths 2 3 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 96048, 9511, 9432A TEE=LOK MiTek Engineering Reference Sheet: Mll-7473 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X -bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 p 4. Cut members to bear tightly against each other. U a 5. Place plates on each face of truss at each O joint and embed fully. Knots and wane at joint ~ locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. @ 2004 MITekO Job Truss Truss Type Qty Ply HANSEN'S GARAGE LOADING (psf) SPACING 240-0 R1516165 HANS0204 Al HOWE 27 1 PLATES GRIP TCLL 16.0 Plates Increase 1.25 TC 0.61 Vert(LL) Job Reference (optional) Longfellow Lumber Co.. Inc., Chico, Ca. 95928-7434, GDA 6.uuu s Jun 17 2004 MiTek ex Inc. mon Feb u 8 2005 Page 1 7-9-14 15-0-0 1 22-2-2 1 30-0-0 r 7-9-14 7-2-2 7-2-2 7.9-14 Scale = 1:51.4 4x4 = 3x6 = 9 8 7 6 3x10 11 3x10 II 1.5x4 II 3x4 = 1.5x4 II 3x8 = 1-0.0 7-9.1415.0.0 ] 22-2-2 29.0-0 r 1 1-0.0 8.9-14 7-2-2 7-2-2 6-9-14 1-0-0 Plate Offsets (X Y)' [1.0-0-14 0-0-2] [1'0-0-4 Edge] [5:0-0-14 0-0-2] [5'0-0-4 Edge] LOADING (psf) SPACING 240-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 16.0 Plates Increase 1.25 TC 0.61 Vert(LL) -0.11 8-9 >999 240 MT20 220/195 TCDL 10.0 Lumber Increase 1.25 BC 0.61 Vert(TL) -0.23 8-9 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(TL) 0.06 5 n/a n/a BCDL 7.0 Code UBC97/ANS195 (Simplified) Weight 127 lb LUMBER TOP CHORD 2 X 4 DF No.1&Btr G BOT CHORD 2 X 4 DF No.1 &Btr G WEBS 2 X 4 DF Std G WEDGE Left 2 X 6 DF SS, Right 2 X 6 DF SS REACTIONS (Ib/size) -1=975/0-5-8.5=975/0-5-8 Max Horz 1=9(load case 4) Max Upliftl=2(load case 5), 5=2(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1820/3,2-3=1241/34,3-4=1241/34,4-5=1820/3 BRACING TOP CHORD Sheathed or 44-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOT CHORD 1-9=0/1670, 8-9=0/1670, 7-8=0/1670, 6-7=0/1670, 5-6=0/1670��� `1WEBS 2-9=18/251, 3-8=421638.4-6=18/251. 2-8=5B2/30, 4-8=582/30 COUNTY NOTES BUILDING DIVISION 1) Unbalanced roof live loads have been considered for this design. 2) This truss has been designed for the wind loads generated by 75 mph winds at 25 It above ground level, using 10.0 psf top chorddead ��^��, D load and 7.0 psf bottom chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1, condition I enclosed buildin of r dimensions 45 ft by 24 ft with exposure B ASCE 7-93 per UBC97/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are exposed to wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) A plate rating reduction of 20% has been applied for the green lumber members. LOAD CASE(S) Standard 044 0/-S February 7,2005 A WARNING - Ver(& design parameters and READ NOTES ON THIS AND INCLUDED MITES REFERENCE PAGE MH --7473 BEFORE USE. 7777 Greenback Lane r_r_m Design valid for use on with MiTek connectors. This design is based on upon Suite 109 only g N en parameters shown, and 'a for an individual s design component. Citrus Heights, CA, 95610 Applicability of design paramenters and proper incorporation of component k responsibTty of building designer- not truss designer. Bracing shown B for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage. delivery. erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component M Bek h Safety Information available from Truss Plate Institute. 583 D'Onofrfo Drive, Madison, WI 53719. CDF FIRE SAFE REQUIREMENTS AP# Z6&f-2�V - 10% PERMIT # 05- NAME/1/Sc�/lJ r v Under authority of Public Resources Code Sec. 4290, the following checked items are required T by the Butte County Fire Department and made a part of this permit. These requirements are minimums and may be superseded by Butte County local regulations, which equal or exceed these standards. Butte County Building Inspectors will make compliance inspections. Driveway Standards pq Surface. All driveway surfaces and structures (bridges, culverts and other appurtenant structures which supplement the roadway bed or shoulders) shall provided unobstructed access to conventional drive vehicles, including sedans and fire apparatus weighing up to 40,000 pounds. 16 I pq Grade. Not to exceed percent unless paved. Driveway Radius R pq No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall be added to curves of 50-100 feet radius; 2 feet to those from 100-200 feet. pq The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 T feet radius. x (XJ Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. pq Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum n 25 -foot taper on each end. Q pq Width. All driveways shall provide a minimum 10 -foot traffic lane and T T unobstructed vertical clearance of 15 feet along its entire length. U pq Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in T length, shall provide a turnout near the midpoint of the driveway. Where a 1 driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. Gates pq 1. Gate entrances shall be at Ieast*two feet wider than the roadway E they serve. 2. The gates must be located at least 30 feet from the roadway and M shall open to allow a vehicle to stop without obstructing traffic on the roadway. 3. Where a one-way road with a single traffic lane provides entrance, a 50 -foot turning radius shall be used. T T S Setback for Structure Defensible Space [X] Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provided for by the landowner. (] 1. All parcels 1 acre and larger shall provide a minimum 30 -foot setback for buildings and accessory buildings from all property lines and/or the center of the road. - 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See 'Other Requirements below. [X] Disposal of Vegetation and Fuels: Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction of flammable vegetation and fuels caused by site development and construction, road and driveway construction. Disposal shall be completed prior to completion of road construction or final building permit inspection. Other Requirements [ ] If Building Setback is 15 to 30 Feet: ✓ Class A or B roof Enclosed eaves If Building Setback is Less Than 15 Feet — . ✓ Class A or B roof with enclosed eaves and choose any 2 of the following: ❑ Metal or no doors on side toward property line with insufficient setback ❑ Interior automatic sprinkler system per NFPA 13D ❑ Glass area not to exceed 10% of wall area toward property line with insufficient setback ❑ Siding from the following list: o Stucco — 3 coat o Hann -Board or Plank o Masonry o Masonry Veneer o Metal o Other Butte County Fire Department approved materials Date Signature --4 C D F R E Q U I R E M E N SI ..r., *,-:,..,NT'f OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION c5 7 Ceunty Center Drive - Oroville, California 95965 - Telephone (916) 538-754 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT --�-- ASSESSORPARCEL NUMBFA ZONING BUILDING PERMIT OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION 0 Zo. ERS f •ORE S ArL 000 CO CTOR' 11M1 TELEPHONE 0f i•• CONTRACTOR'S "UNG ADDRESS CONSTRUCTION LENDER 5 Q Fireplace LENDER'S WJUNG ADDRESS Total Valuation Is ARCHITECT CR ENGINEER LICENSE NO. Filing Fee 20.00 Permit Fee ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee BUILDING ADDRESS 2 u� IJ Energy Plan Checking Fee $ $. PERMIT FEE $ LAT NO, SUBDIVISION'S NAME PAR EL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USE OFSTAUCTURE SF � Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.0 TYPE OF WORK Utilities ❑ Installation ❑ Other - New g Addition ❑ Remodel 13�I Describe Work: 1-1 , Q" 6 F Gas piping system 1 - 5 outlets 15.00 f$'- Buildingsewer 15.00 Mobile Home S G W @20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Feel 20.00 Main Service ".v OR. 'ss 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. , Business and Professions Code for this reason Main Service 200A TO LGOOA 46.00 Se,/I' NEW CONST. DWELLING OCCUP. OR ADONS. ( a ACC. S. s0 3.50FT. =REO,SIp_ MULTI -OUTLET @7.50 °OWER APPARATUS a SINGLE OUTLET CIR. Ex. Occu OFIXEDA SAL o I:w PLNS. OR FIXED APPLNS. OR Ex. Occup. OUTLETS REBID. EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 l� PERMIT FEE t MECHANICAL PERMIT Fling Fee 20.00 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by "section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. 1 X Date (� ` C/ % _ Signature of Applicant- ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Heating JS Cooling Hood 6.50 S� Ventilation 45D 4 -SP PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST. TYPE - TOTAL FEE $ IMP I FLOOD I CDF PARCEL I PD HD ISS Ut HAZ. I D. FEES This permit is hereby issued under the applicable of the Butte County Code and/or Resolutions indicated above for which fees have been By Date PERMIT EXPIRES ON I provisions . to do work paid. ReceiptNo. r — — .. . - ..... .. ..,. r.. . b, ,.,eoer r_n, le�ANT 4 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION • *7COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER:J=�a!jASSESSOR PARCELER: ) I D Proposed Building Use: uilding Inspector: Date: tilig At time of permit application, I wfis advised the Mowing data must be submitted prior to permit p ce sing and/or issuance: Date Received By ❑ 1. All items have been submitted -------------------------------------------------------------------------------------- 92. Plot plans, 3/4 sets, signed by the preparer of plans. ---------------------------=- ------------------------------ Complete plans, 3/4 sets, signed by the preparer of plans.-��--9��_�5...................... — r 4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown onplans .-------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ E916. Energy Design Compliance and supporting documentation. ---------------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. --------------------------------------------------------- ❑ 8. Hazardous Material Form. ------------------------------------------------------------------------------------------ ❑ c ' ��9. Manufactured Home data and installation instruons including ie Down Specifications.------------------ lirlk Fees of $ • - -- -- ----- 3_?,__-- "=--------------------------------------- 2'fl . Impact fees as shown on the attached schedule. ----- --------- - - '212. California Department of Forestry plan approva fees. --21--------------------------------- 0 ------------------------------- ❑ 13. Fl elevation certificate. -------------------------- ----------------------------------------------------------- ❑`14. anitation and plot plan approval (a1/1 Health Department. ------------------------------------------- 7 ❑ 15. City of Chico plumbing permit. ----------------------------------------------------------------------------------- 16. Plot plan and business license approval frome City of Biggs. ---------------------------------------------- _ (B) Parking: -------------------------- ❑7. Planning approval for (A) Use:❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- ❑ 19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- 0 20. Pre -inspection for required. Request to Building Inspector on (Date) 021. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ ❑22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- 023. Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- 024. Letter of signature authorization. -------------------------------------------------------------------------------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑ 28. Existing violations and/or expired permits. --------------------------------------- ------------------------------ 029. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ .--------------- 030. -------------- ❑30. Other:------- Wh n you issue the ermit, process as follows ❑ Mail to owner, ❑Mail to ontractor. Telephone 3 and hold for pickup at 0(� office. ❑ Deliver with inspector. Applicant: &-a;2LZ�,V. %4�Date: V 02 J % % Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Date:_ By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: 1. Index permit application for the above items numbered: t7 1 , 1 Z , 1 ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, er w sed of the above r data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Plans reviewed by: Date: a Plans approved by: Date: Sets of plans on hol4m ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. '"`i.y-vi'�i'+`..r"ivr"��+g: �'.�"ii 4����`r��+�.�+ys.F,.-"r-•-,-.�rw..wnrr,+3tY'�.r'*fi'r,,t.e'tiP::f`"��ST�3x 7Y�"�6C.:`.�=.•'1;'',;-�T�'F:,:i,,r':%:�.,N'.7`—.w..,-:.,,,- COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7'COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916). 538-7541 SCHEDULE OF FEES DUE OWNER . A.P. # :. g _ PIO.- I Q'. PROPOSED BUILDING USE DATE - :�4 REC # DATE REC ✓ 1. BUILDING PERMIT FEES J -- Balance Due ................ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES VI D (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ x $360.00 = $3�D 0 Units Commercial (sq.ft.)... x $0.03 = $ Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x = $ #Units Amt. Commercial (sq.ft.) .. x =$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $425.00 (paid at Building Division) 6e7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER aay�a� At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT /�� ,, o J Gf`�Q"t J DATE Original -Owner Copy -Building Div. (Rev. 12/96) { OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building ,permit will be issued until this verification is received. I personally plan to provide the major labor and materials for construction of the proposed property improvement : YES NO ❑ I HAVE X HAVE NOT C1signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction: NAME: �. ADDRESS: CSL. PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide some of the work but i have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK 7SGD: ROPERTYOWNER: ���,,aJ�;,O�CIAL SECURITY NUMBER: %-99ATE: -2— NOTE. 2-- NOTE: This Owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. OVER OWNER BUILDER INFORMATION Dear Property Owner: / S _ An application for a building permit has been submitted in your name listing yourself as the builder of proper improvements specified. For your protection, you should be aware that as `.owner -builder'' you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself. you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: t If you employ or otherwise engage any persons other than, your immediate family. and the work (including materials and oter costs) is $300 or more foi:"_fhe enaie p ojcct; and such persons are licensed as contractors or subcontractors, then you may be an employer. ♦ If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security tares, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. ♦ There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. ♦ For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "owner builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not, be issued until the verification is returned. t rely, Mic el C. Vi ira, C.B.O. Ma ger, Building Inspection NOTE. This Orvner-Builder Information is required by Section 19830 of the California Healtir and Safety Code - OVER 068-210-109 PERMIT#97-1405 HANSEN, Lloyd & Maxine 23 Buehler Ave., Oroville Conv Port Garage to 2nd Dwelling & Add'l Sq Ftg s COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION NOTICE Post this Job card in a safe conspicuous place. Do not remove until all required inspections are made and building is approved for occupancy. Plans must be available on the job site. A• 068-210-109 PERMIT#97-1405 0i HANSEN, Lloyd & Maxine 23_Buehler Ave., Oroville Cc Coriv Port Garage to 2nd .Dwelling & Pe Add'1 Sq Ftg PERMITTEE MUST CALL FOR INSPECTIONS Footings Piers Underground Conduit Pre-Gunite Do.;Not Pour Concrete: Until :Above; Signed Underfloor Plumbing Underfloor Electrical Underfloor Mechanical Underfloor Framing Slab Kougn rwmDing Rough Electrical Rough Mechanical Framing Shower Pan Insulation or Do Not Insulate Until Above Sinned Uo Not Cover Until Above Sinned Firepiace footing Fireplace Throat Do Not Continue Fireplace Until Above`Signed Stucco Lath Scratch and Brown Do Not Cover. Until Above Signed Sewer Service Water Service Pool Final Plumbing Final Electrical Final Mechanical Final Building or M.H. Final DO NOT OCCUPY UNTIL ALL THE ABOVE IS SIGNED AND THE BUILDING OR MOBILE HOME IS APPROVED FOR OCCUPANCY Addresses Information 24=Hr Ins Oroville 7 County Center Dr. 538-7541 538-7636 Chico 891-2751 891-2834 Revised 7/94 U UNITED STATES POSTAL SERVICE TM IMPORTANT Because we know your time and money are valuable, we suggest you call your local Post Office before you install a mailbox_ Ask to speak to the Carrier Supervisor, who will tell you the proper location for your box and explain current requirements for mail box installation. The location and other requirements must be approved by the Carrier Supervisor, before your carrier will begin delivery. Thanking you for your cooperation COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT 9�%-� DS ASSESSOR PARCEL NUMBER 0680210-109 ' ZONING BUILDING PERMIT OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION 380 R 20,520.00 OWNER'S MAILING ADDRESS 966 UR 19000.00 CONTRACTOR'S NAME TELEPHONE 79 COV 1,027.00 12 6 OPEN CONTRACTOR'S MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Ellin Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 93 RITETILER AVE Energy Plan Checking Fee $ $ nPF9 95965 PERMIT FEE $ LOT NO. SUBDIVISION'S QAMIE PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF [X Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New E2 Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other 13,� Describe Work: USE PERMIT FOR 2ND DWELLING CONV 2ND FLOOR GARAGE TO SF & ADD. Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service 200A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.b License Class LIC. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: 34 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. SG OR ADDNS. ( a ACC. Bins. 3.5QFT: NEW CONS.9 NON -RES DT AUL, CIRCUITS @7,50 PSINGLE OUOWER APPARATUCIR.S 'T ET 20 @ 1.00 Ex. Occu OUTLET OR FIXTURES BAL @ .50 PPLNS Ex. Occup. DurELeTs REFS p,OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. Wgn,tur of Applicant Date �_ — � - A Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ HAZ, I D FEES IMP I FLOOD CDF PARCEL PO HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date _ PERMIT EXPIRES ON Date Receipt No. 924175 — 395_A5JJ WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION -.4 7 County Center Drive - Oroville, Calif6rnia 95965 - Telephone (916) 538-7541 n P RMIT 10. (Rev.12/96) APPLICATION AND PERMIT l' 505 ASSESSOR PARCEL NUMBER 0080210-109 ZONING AR BUILDING PERMIT OWNER F HANSEN TELEPHONE SO. FT. OCC. BUILDING VALUATION 380 R 20,520.00 OWNER'S MAILING ADDRESS 21 BITFUTER AVE, OROVITIF, 95065 966 UR 19 000.00 CONTRACTOR'S NAME TELEPHONE �/ 79 COV 027 .00 OPEN CONTRACTOR'S MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation Is ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 23 RTWTFR AVF Energy Plan Checking Fee $ OROW11F. 99965 PERMIT FEE $ LOT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF 13 Duplex ❑ Mobilehome ❑ Other - SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ®i Describe work: USE PERMIT FOR 2ND DWELLING CONV 2ND FLOOR GARAGE TO SF & ADD. Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home IS I GI W 1 @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service AORLESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class LIC. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjurythat I am exempt from the Contractors License Law for the following reason: y�1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service 200A To 1000A 46.00 NEW CONST. DWELLING OCCUP. SO OR ADDNS. ( 6 ACC. BUDS. 3.5¢FT, NON-RESID. MULTHOUTLE7 97.50 I. POWER APPARATUS 8 SINGLE OUTLET CIR. .00 Ex. OCCU OUTLET OR FIXTURES BAL @'. 0 Ex. Occup. ouITXLEEDARN. OERA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. G X �= __ Date 2 — / �__ gnature of Applicant - `p Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE e HAZ. I D. FEES IMP I FLOOD CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON Date ReceiptNo. 22LLI ?ri — i95, Q5// WHITE •D.D.S.•B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD 11 -APPLICANT IN COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES- BUILDING DIVISION Vy „ _.. ..� 7 County Center Drive - Oroville, , Calif6Tnia 95965 - Telephone (916) 538-7541 PERMIT NO. (Rev. 12/96) -3 APPLICATION AND PERMIT 9 1'4 ASSESSOR PARCEL NUMBER 0—Q ZONINAR G BUILDING PERMIT OWNER R M x NE, r NS TELEPHONE SO. FT. OCC. BUILDING VALUATION 390 R20,520.00 OWNER'S MAILING ADDRESS 7-1 RITERT FR AVE (TROVII I r 0596-, 966 UR 19.0m.00 CONTRACTOR'S NAME TELEPHONE L []�, 7L ciov 1,027.M ^ `)27 M (r 6 4 f1 CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation is ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ 0R0yT1 I F. QrQ65 PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USE OF STRUCTURE SF Q_" Duplex ElMobilehome ❑ Other - _ SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK ' New O Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ay Describe Work: USE PERMIT FOR 2ND M-11.ITIG CONV 214D FLOOR GARAGE TO SF & ADD. Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home IS I G1 W1 920.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service 200, OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. O 1 am exempt under Sec. Business and Professions Code for this reason Main Service ( 200A TO 1000A 46.00 NEW CONST. DWELLING OCCU. SO " OR ADDNS. ( a Acc. BLOB. P3.54r. NON-RESNEW IID. TI-OUTLETCIRCUITS @7,50 APPARATUS b SINGLE OUTLET CIR. 20 Q 1.00 Ex. Occup. OUTLET OR FIXTURES BAL p .so Ex. Occup. our�rs(RESID.DE.A 5.00 Temporary Service 23.00i Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE S Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. / �X�/, . > ti� ,,,T Date=_` y Signature of�cant - CO Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ HA2. D. FEE IMP I FLOOD I CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON I Date ReceiptNo. 22412.5 — 325.Q9// WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT -(ReV.12/96) COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroville, Califi5rnia 95965 - Telephone (916) 538-7541 PERMIT NO. F - - APPLICATION AND PERMIT' ASSESSOR PARCEL NUMBER 0IM0210-109 ZONING AR BUILDING PERMIT OWNER H TELEPHONE SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 21 MMM ER AVE ORM11.111% 95-965 966 UR 119.0m.00 CONTRACTOR'S NAME TELEPHONE Y 79 „ My CONTRACTOR'S MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filen Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 23 MUM ER AVE Energy Plan Checking Fee $ $ 4 PERMIT FEE $ LOT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Water gas water heater or vent 15.001 TYPE OF WORK ' New EI Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other f Describe Work: USE PM MIT FOR 2ND DMLING COW = FLOOR GARAGE TO SF & ADD, Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 OOR LE Main Service ''2 zoos oR ss s' 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000 of Division 3 of the Business and Professions Code, ( g ) and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: g] I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service ( 46.00so NG CCU000A NEW CONST. DWELLING OCCUP. SO DWE200ALLING OR ADDNS. ( & ACC. BUDS. 3.5¢FT. NEW CONST. MULTI -OUTLET =R IDT I c @7.50 POWER APPARATUS 8 SINGLE OUTLET CIR. zo p ,.00 Ex. Occup. OUTLET OR FocruREs BAL @ .so Ex. Occup. ourLEEDTAPPwoOEn 5.00 Tem orar Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) Q I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X / , _ �. .. _ =s=.. _ Date 7 - .2 - Signature of'Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ HAZ. D. FEES IMP FLOOD CDF PARCEL I PO HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON Date ReceiptNo. 224223 — 325.951% WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT - 068-210-109 00-3010 HANSEN, LLOYD 21 BUEHLER OROVILLE CONTR: OWNER GAS HEATER k uvar �- �-4,1) ' 1 _ a r r � �- �-4,1) ' 1 _ P r � �- �-4,1) ' 1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION **� 4 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 Mp MIT NO. (Rev. 12/96) APPLICATION AND PERMIT M"- ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER LWn HANSEN TECH.33-4913 5 SO. FT. OCC. BUILDING VALUATION OWNER'S 7V"a•+VaiEsil ER AVE, 0XVILLE 95966 ` CONTRACT 'Sf�_ r �E TELEPHONE f ' CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 21 BUEMLER OROVILLF Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF f Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities EX Installation ❑ Other ❑ Describe Work: "AS NEATER & HVAC Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ ELECTRICAL PERMIT . Fling Fee 20.00"OVOR LE Main Service 2o.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWEPPARATUS License Class Lic. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: J9 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) O 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date _ Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( a ACC. S. s0 3.5¢FT. Np CONST1MULTI.OUTLET @7,50 a SINGLER AOUTLET CIR. EX. OCCU OUTLET OR FIXTURES ®'.50 BAL .SO Ex. Occu . oFlx�e�DSA R DOEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating 15.00 Cooling HVAC 30.00 Hood 6.50 Ventilation PERMIT FEt $ 65.00 Mobile Home Installation Fee $ Energy Inspection Fee $ occ g3 CONST. TYPE TOTAL FEE $ 65.00 HAz. D. FEES IMP FLOOD CDF PARCELPD HD SUE This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicatedo,above for which fees have been paid. By., _ Date PERMIT EXPIRES ON Date Receipt No. 4, 3'L,171 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT Insulation Certificate BUILDING OWNER: BUILDING PMUUT 0: / / Description of Installation ROOF Material Thickness (inches) CEILING Brand Name Thermal Resistance (R -Value) B= or Blanket Type Brand Name Thickness ('inches) AV -f All Thermal Res' ce.(R-Value) Loose Fill Type Brand Name -Contractor's minimum installed weight/ftL lb Minimum thickness inches Manufacturer's installed weight per square foot to acheive Thermal Resistance (R -Value) EXTERIOR -WALL Material Brand Name Thickness (inches) Thermal Resistance (R -Value) IS RAISED FLOOR Material Thickness (inches) SLAB FLOOR Material Thickness (inches) Width (inches) _ FOUNDATION WALL Material Thickness (inches) Declaration Brand Name Thermal Resistance (R -Value) Brand Name Thermal Resistance (R -Value) Brand Name Zhetinal Resistance (R -Value) I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Building Energy Efficiency Standards for new residential buildings contained in Title 24 of the California/A (ministrative,Qode. Signature and Title Sub -Contractor (Insulation Installer) S ignature and Tide License Number g— %— 0/ — Date License Number Dace THIS CERTIFICATE MUST -BE PROVIDED TO THE BUILDING DEPAR'T'MENT PRIOR TO FINAL INSPECTIO APPROVAL AND A COPY SHALL BE POSTED WITHIN THE BUILDING. JANUARY 1993 ENGINEERED WOOD SYSTEMS 8 Tt Certificate of Conformance Certificate • 0 5 4 0 6 5 THIS IS TO CERTIFY that the glued laminated timber products identified with a collective mark of Engineered Wood Systems (EWS) were manufactured in accordance with the applicable standards and associated specifications indicated below: ANSI Standard A190.1-1992; ForWood Products— Structural Glued Laminated Timber. NER-486 Glued Laminated Timber Combinations And "GAP" Computer Program For Determining Design Stresses AITC 117-93 — Manufacturing Standard Specifications For Structural Glued Laminated Timber Of Softwood Species IT IS HEREBY CERTIFIED that the APA EWS trademarked'structural glued laminated timber members were produced in a manufacturing facility subject to regular audits in accordance with the Engineered Wood Systems (EWS) Quality Assurance Program.'Routine audits include inspection of the manufacturing process and evaluation of the in -plant QA program with .adequate sampling to verify conformance to industry standards for lumber grade and glueline bond quality. .••�0 W0�4���i 0 ,2 go ON%SEAL 3, : c'. T •. 9 by — Thomas G. Williamson Executive Vice President ENGINEERED w000 SYSTEMS is a related corporation of APA — THE ENGINEERED WOOD ASSOCIATION 7011 South 19th Street • P.O. Box F 117x00 Tacoma. 587289 700 Telephone: (25) 565.8800 ( ) i INEWIN..M COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE PERMIT A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. 1b ! �lr r Date /2//�� Inspector—Wo— REV nspectorWoREV 10 92 i COUNTY OF BUTTE ' BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE / /, c��� z� - / / � 7 OWNER PERW A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completeo/ If you have any questions pertaining to this matter, or need additional explanation, please ontact this office immediately. a�> .� Date Inspector REV 10%92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 . CORRECTION NOTICE I cit, c..at_.3 — r I OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. Date ff/24 /UA Inspector i REV 10/92 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 G�PPEERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT �-,1 D ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER LLOYD HANSEN TELEPH 533-4913 SO. FT. OCC. BUILDING VALUATION .OWNERS TING ADDRESS 2 BUEHLER AVE, OROVILLE 95966 CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 21j BUEHLER OROVILLE Energy Plan Checking Fee $ $ PERMIT FEE S LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF � Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ER Installation ❑ Other ❑ Describe Work: GAS HEATER & HVAC Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W (920.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 Main Service ZoOA OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Lav, for the following reason: Y, 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service Zoog TO I000A 46.00 NEW CONST. DW %NO OCCUP. SO OR ADDNS. ( a ACC. BLnS. 3.50x; T. NoµgESID. ANCHOUTLETIRCUITS @a 7.50 POWER APPARATUS a SINGLE OUTLET CR. TO O 1'00 Ex. Occup. OUTLET OR FDCTUREs BAL. o .50 Ex. Occup. DS S q 6J EA_ 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S MECHANICAL PERMIT Filing Fee 20.00 Heating 15.00 Cooling HVAC 30.00 Hood 6.50 Ventilation PERMIT FEP S Policy Number (The above sections need not be completed if the permit is for work of a valuation 'of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. Xff�� _ Date ion ;_V_ 4�9d Signatur of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ RX CONST. TYPE YN TOTAL FEE $ 69 HAZ. I D. FEES IMP I FLOOD I CDF PARCEL I PD HD SUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for hich fees have been paid. at l PERMIT EX ES ON Date Receipt No. 309338/$65.00 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT / ,a COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 Counter-Centgr Drive • Orovil!e, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) �APPLICATION AND PERMIT l M ASSESSOR PARCEL PARCEL NUMBER 068-210-109 ZONING AR BUILDING PERMIT OWNER LLOYD HANSEN TE 533-4913 SO. FT. OR,. BUI DING VALUATION OWNERS MAILING ADDRESS27 BUEi' LER AVE., ORO 959,6 CONTRACTOR'S NAME Ar ER TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Fling Fee 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS 27 VBUEHLER AVE. ORO Energy Plan Checking Fee $ $ PERMIT FEE $ LAT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling a 20.00 USEOFSTRUCTURE SF X3 Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each flS water heater Of vent 1 5.00 PE OF WORK New ❑ Addition ❑ Remodel Utilities ❑ Installation ❑ Other ❑ Describe Work: I- l /� — Co "4T EL) PLC-, Gas piping stem 1 - 5 outlets 15.00 Buildingsewer 15.00 Mobile Home S G W @20.00 PERMIT FEE S - ELECTRICAL PERMIT Fling Fee 20.00 Main Service x'oo i oa LFss 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class LIc. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: 113-- ; as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service WELL L000A 46.00go NEW CONST. DWELLING OCCUP. NG OR ADDNS. s ACC. eLAs. S° 3.5¢FT: TNgµq°SID. MULTI OUTLETBRANCH CIRCUITS @7,50 POWER APPARATUS E SINGLE OUET CIR. TL OUTLET OR FIXTURES Ex. Occup.SAL ® .SO LNS Ex. Occup. G TIEDTS�EsID-°.R. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE _ WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 Heating 6A Coolin U '[✓ d Hood 6.50 Ventilation PERMIT FEt S Policy Number (The above sections need not be completed If the permit is for work of a valuation f one hundred dollars ($100) or less.) ae certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the C workers' compensation provisions of section 3700 of the Labor ode, I shall forthwith comply with those provisions. _ /fj' X,yt.°`7� dT �"s�:s.."!. s.re.T Date QE`s- 00 Signatdre of"Applicant-- a-OWner O Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction er 3 sto_ies in he of structures ov'ght. Receipt No. 77773 �' v — Mobile Home Installation Fee $ Energy Inspection Fee is OCCNST R3 CO TYPE VN TOTALFEE$JJW 6 HAZ D FEES IMP FOOD A CVOF A PCQ pp v a SSUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have e , ^i ` p ;, By '- 7: 'f . • . PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date Te WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to ' avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. t 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement: YES[ NO[ ]. _,2. I HAVE [YJ HAVE NOT[ ] signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide. -the proposed construction: NAME: ADDRESS: CITY' PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work,' but I have hired the following person'to coordinate, supervise, and provide the major work: ' NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide some of the work but I have contracted (hired) the following.$ersons to provide the work indicated: ' NAME ADDRESS PHONE TYPE OF WORK SIGNED: PROPERTY OWNER: r � D TE: NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. .4> Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners .unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from -the city or cou* nky. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own woik, with the exception of various trades that you plan to subcontract, you should be: aware of the following information for your benefit and protection:. 0 If you employ or otherwise engage -any, persons other than your immediate family, and the work (including materials and. other costs) is'.:5300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then di may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. 0 There may be financial risks'for*you if you do not carry out these obligations,`and,these risks are especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division'of Industrial Accidents. '. If the structure is intended for sale, property owners who are not licensed contractors -are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. , A frequent practice of unlicensed persons professing to be contractors is to secure an ` ownerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm. that you are aware of these matters. The building permit will not be issued until the verification is retumed. ji ply, /Vi ira, C.B.O. ,uilding Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. NOTES I I RESIDENTIAL r 068-210-109 00-1197 PERMIT NO. AH�ANSEN, LLOYD , H BUEHLER AVE., OROVILLE CONTR: OWNER ROOM ADDI(T.ION, & RE -ROOF I,;\ 21 $a �/v SPECIAL CL 101 SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER CHECKED BY JOB FINALED (Date) Signature p ' rte r ... SPECIAL CL 101 SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER CHECKED BY JOB FINALED (Date) Signature ✓ = OK 0 = Not OK - = Not Applicable = Not Ready; MOBILE HOMES Date ` MOBILE HOME UTILITIES (Plans) OK except #'s Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements Footings; Soils -Size -Depth -Spacing -Connectors -Steel 2. Soils; Special MH Support Sketch Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer; Location -Test -Fall -C/O -Concrete Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Frg-Bracing 4. Water; Location -Test -Easement Needed (Sketch) Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Carports; Windows -Doors 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or/ /"L"ft./ /'LPG Electric 7. Well Clearance & Disconnect Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 8. Utility Clearance Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 1. 4. Electricity; MH Test -Crossovers -Breakers -Clearances 2. 5. Drain; MH Test -Fall -Flex Connector 3. 6. Water; MH Test -Regulator -Connector 4. 7. Water and Sewer Connected -C/O to Grade -HD Approval 5. 8. Gas and Electricity Tagged 6. 9. Tie Downs -Type -Installation Cert. 7. 10. Exits; Insp.-Sketch 8. 11. Cert. of Occupancy 9. 12. Permanent Foundation Only; License Decal 10. Plumb.; Cir. Test -Water Supply Test Date Light Niche Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J = OK 0 = Not OK - = Not Applicable = Not Ready 15. RESIDENTIAL Date 16. Wfiderfloor (Plans) OK except #'s 00'Zonipif-'setbacks-Easements-Flood-Slope Date Date Card B-1 Date ig., Main; Soils-Elec. Grnd.-ig. Depth Dat 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Fig. Depth Date 4. Fig., Porches & Decks; Soils -Steel-/ /" Ftg. Depth MECHANICAL (Permit) OK except #'s 5. Stemwalls, Main; Steel -Blackouts -Wrapped 35. 6. Ste mwalls,.Garage; Steel-Blockouts-Wrapped 6a. Hold_26w.s and Special Anchors f7 8. ab, Steel -Wrapped Piers -Fireplace Ftg.-Steel Condensate Drain & Overflow, Size & Grade 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 38. 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 39. 11. Water Pipe; Test -Anchors -Regulator -Service Test Date 12. Electric Underground Date 13. Plenums & Ducts; Clearance- Matelial-Support-Ins. (Single & Duplex) 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. nge Circle / / ga Cu or AI -Oven Circ. / / ga Cu or At �. Insulated Neutral I] Yes O No 10 0 1. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 15. Access & Ventilation 16. Insulation Date Date Card B-1 Date Card B-1 Date Card B-1 Dat 12_1 60 Card B-1 Date Card B-1 Date Date PLUMBING (Permit) OK except #'s MECHANICAL (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 35. 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access Condensate Drain & Overflow, Size & Grade 21. Test Tub & Shower, Second Floor -Tub Access 38. 22. Gas Pipe; Sixe & Anchors 39. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. nge Circle / / ga Cu or AI -Oven Circ. / / ga Cu or At �. Insulated Neutral I] Yes O No 10 0 1. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light Date FRAMING (Permit) OK except #'s is Proper Materials & Anchors 1,VNalls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing Draft Stop in Walls (rat proof) 44. Firp Stops, Furred Ceilings -Stairs -Chasers -Tubs eaders & Beams -Size & Bearing Date FRAMING (Continued) Ha gars -Post Caps -Anchors -Connectors Cling. Joist-Rftr. Ties- Purlin-Rolf Brac.-Truss-Shting.-Rfng. ype e- Fireplace Throat Clearance Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles term. Windows or Exiting Doors -Sill Ht. & Dimensions ge Fire Protection Framing e y Line Firewall & O enings xt. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54 dt -Headroom- ise-Run-Landing-Fire Protection . Plywood on Roof Overhang -Attic Vents -Rafter Outriggers . Siding -Nailing Veneer _ tucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Glazing Area -Glass Protection -Skylights -Plastic a s; ailing- o Is Brace Interior/Exterior W I Panels sulati-Wa-f�;C'eili g 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date • FINAL Plans OK except #'s xt. Steps -Door & Sidelight Protection -Landings moke Detector Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection I edroom Exiting . & Bath Fixtures & Tub Access -Spa lec. Trim & Subpanel, Breaker Sizes & Labels ra Virs-ITails 7 rance-Hearth J_J,1 ec. Outlets at Wood Panel, Int. & Ext. i . ixt. & App ion -Air Gap -Cooking Clearance 7 ec. u e s it. Counter 7 rag -Closure 75 76. W mb. Air Connector-P.R.V. in arage; Above Floor-Mech. Protection O*-Elec. & Mech. Equip. Listed for Location 7 51.)-Romex Protection Insulation -Foam -Looked in Attic 8 r ails & Deck Constru ion -Post Caps Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 82-NeAN9*s Q Yes 0 No/Planters Q Yes J No rown- nish isconnect, ec ncal-Plumbing , 81,_ Vance Ah -a Pool amg:Apptiance-Fireplace-Clearance to Openings 8 ciTical, Plumbing Exterior Elec. Trim, G.F.I. Receptacle -Underground 18 ntilation Throughout House [t3 ess Protection 190._Gerr tions from vious Inspections tqt Gas T - eters Tagged, Gas -Electric ater & Sewer Connected -C/O to Grade -HD Approval UL!!! -gy Compliance Certificate -Other Certificates 9 Address Posted Date Card B-1 Date Card B-1 Date Card B- Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: 34. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35. A.C. Ducts Insulation & Support 36. Vent Fan, Exhaust above insulation 37. Condensate Drain & Overflow, Size & Grade 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 39. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s is Proper Materials & Anchors 1,VNalls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing Draft Stop in Walls (rat proof) 44. Firp Stops, Furred Ceilings -Stairs -Chasers -Tubs eaders & Beams -Size & Bearing Date FRAMING (Continued) Ha gars -Post Caps -Anchors -Connectors Cling. Joist-Rftr. Ties- Purlin-Rolf Brac.-Truss-Shting.-Rfng. ype e- Fireplace Throat Clearance Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles term. Windows or Exiting Doors -Sill Ht. & Dimensions ge Fire Protection Framing e y Line Firewall & O enings xt. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54 dt -Headroom- ise-Run-Landing-Fire Protection . Plywood on Roof Overhang -Attic Vents -Rafter Outriggers . Siding -Nailing Veneer _ tucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Glazing Area -Glass Protection -Skylights -Plastic a s; ailing- o Is Brace Interior/Exterior W I Panels sulati-Wa-f�;C'eili g 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date • FINAL Plans OK except #'s xt. Steps -Door & Sidelight Protection -Landings moke Detector Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection I edroom Exiting . & Bath Fixtures & Tub Access -Spa lec. Trim & Subpanel, Breaker Sizes & Labels ra Virs-ITails 7 rance-Hearth J_J,1 ec. Outlets at Wood Panel, Int. & Ext. i . ixt. & App ion -Air Gap -Cooking Clearance 7 ec. u e s it. Counter 7 rag -Closure 75 76. W mb. Air Connector-P.R.V. in arage; Above Floor-Mech. Protection O*-Elec. & Mech. Equip. Listed for Location 7 51.)-Romex Protection Insulation -Foam -Looked in Attic 8 r ails & Deck Constru ion -Post Caps Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 82-NeAN9*s Q Yes 0 No/Planters Q Yes J No rown- nish isconnect, ec ncal-Plumbing , 81,_ Vance Ah -a Pool amg:Apptiance-Fireplace-Clearance to Openings 8 ciTical, Plumbing Exterior Elec. Trim, G.F.I. Receptacle -Underground 18 ntilation Throughout House [t3 ess Protection 190._Gerr tions from vious Inspections tqt Gas T - eters Tagged, Gas -Electric ater & Sewer Connected -C/O to Grade -HD Approval UL!!! -gy Compliance Certificate -Other Certificates 9 Address Posted Date Card B-1 Date Card B-1 Date Card B- Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 FERMI NO. ev.12/96) APPLICATION AND PERMIT I\ ASSESSOR PARCEL NUMBER 068-210-109 ZONING BUILDING PERMIT 1`\\ OWNER LLOYD HANSEN TELEP 533-4913 SO' FT. OCC. BUILDING VALUATION OWNERS MAILING AD SS 21 BUEHLER AVE., ORO 95966 176 R — 9,50400 CONTRACTOR'S NAM OWNER TELEPHONE 900-00 CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Permit Fee $ Plan Checking Fee $ 126.00 BUILDING ADDRESS Energy Plan Checking Fee $ 81.90 --BUEHLER AVE. ORO t PERMIT FEE $ LOT NO. SUBDNISIOWS NAME PARCEL MAP PLUMBING PERMIT ee 20.00 USEOFSTRUCTURE Each Trap 7.00 Solar or heat um water heater3.00 SF J7 Duplex ❑ Mobilehome ❑ Other Water piping 15.00 SPECIFY Each gas water heater or vent 15.00 PE OF WORK Gas piping system 1- 5 outlets 15.00 New ❑ Addition ❑ Remodel VUtilities ❑ Installation ❑ Other ❑ Building sewer 15.00 Describe Work: ROOM ADDITION, AND RE ROOF Mobile Home IS I GI W @20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.00 Main Service 2o0AORLESS 23.00 LICENSED CONTRACTOR'S DECLARATION Main Service 200A TO ,000A 46.00 NEW CONST. DWELLING OC UP - SO G I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter OR ADONS. ( a ACC. BLDS. 3.50FT. 6.15 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, NON-RESID. MULTI -OUTLET CIRCU @7.50 and my license is in full force and effect. POWER APPARATUS License Class LIC. No. 6 SINGLE OUTLET CSR. OWNER -BUILDER DECLARATION Ex. Occup. OUTLET OR FIXTURES BAS 9': o 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Ex. Occup. DFlx�e RESIo.OERA 5.00 Law for the following reason: Temporary Service 23.00 N -1T as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. Mobile Home Facilities 20.00 ❑ 1, as owner of the property, am exclusively contracting with licensed contractors Misc. Wirina 23.00 to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this PERMIT FEE S 26 , 15 reason WORKERS' COMPENSATION DECLARATION MECHANICAL PERMIT Fling Fee 20.00 1 hereby affirm under penalty of perjury one of the following declarations: Heating EX DUCT 15.00 ❑ 1 have and will maintain a certificate of consent to self -insure for workers' Cooling compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Hood 6.50 ❑ 1 have and will maintain workers' compensation insurance, as required by Section Ventilation 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier PERMIT FEE $ Policy Number Mobile Home Installation Fee $ (The above sections need not be completed if the permit is for work of a valuation Energy Inspection Fee $ 46.00 Wepf one hundred dollars ($100) or less.) occ CONST. TYPE I certify that in the performance of the work for which this permit is issued, I shall TOTAL FEE $ not employ any person in any manner so as to become subject to workers' VN �HAZ- D. PEES IMP FLOOD CDF PARCEL Po HD ISSUE compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall fo with com ly with those provisions. This permit is hereby issued under the applicable provisions �// of the Butte County Code and/or Resolutions to do work X �,Q�� Dates o&_f�0 indicated above for which fees have been paid. Signat re of pplicant - �OCniner ❑Contractor ❑Agent An OSHA permit is required for excavations over 60" deep and demolition or construction 6/2:10 � 0 V of structures over 3 stories in height. By�d4__4L_ // ate Receipt No. 294623 $358.05 PERMIT EXPIRES ON (D 1 � Q WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT Da COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION � 7 Count Yr ,Ctmter Drive • Oroville. California 95965 • Telephone (530) 538-7541 ER N( kRev.12196) APPLICATION AND PERMIT��� ='—AL I BUILDING PERMIT \ 01"" Z-- D S OONTRACTO" MW F' Gv CONT" MA's r& J ADORES CommiCnON LME" ❑ aW8%'S U%%M AWMS ARCWMCT Oa ENouWE" ARCHITECT OR O/DMM S UNUM ADDRESS euU XW ADDRESS e --i EN Loll NO. I susavecFXS K*M USEOFSTRUCTURE SF Duplex ❑ Mobilehome O Other OF WORK New O Addition ❑. Re=16�LAXHM&* 0 Installation 0Describe Work:C..x{�"-4 MENIWIIII NERM 411,11 It oil Total Valuation Is Firma Fee $ 7 0.0C Permit Fee $ �p �-- Plan Checkin Fee $ Energy Plan Checking Fee $ S PERMIT FEE -�-- -- PLUMBING PERMIT Filing Fee 20.00 S Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping . 0 Each gas water heater or vent 15.00 ❑ Gas piping system 1 - 5 ou 15.00 Building sewer 15.00 Mobile Ho G I W @20.00 EX. OCCU OUTLET OR FIXTURES PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 Main Service taov Oil V:SS tow oR u¢ss 23.00 Main Service tow TO r000A 46.00 NEW COHb T. OR AWNS. ( OWB AJM oCCUV. • ACC. etas. sa 3.5aR. HLW Flom 9. NONACID. MULTI -OUTLET NAAA `M r - r 07.50 EX. OCCU OUTLET OR FIXTURES m `I 1.ww yLL . DO Ex. OCCU ,ET,�R.,,D 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 W I" PERMIT FEE s MECHANICAL PERMIT Filing Fee 20.00 HeatingDiv G Ul� Cooling Hood 6.50 Ventilation PERMIT FEt S Mobile Home Installation Fee I $ �►S Energy Inspection Fee I $ l' I c—,*', 'E TOT%AL FEE $ .� O.FEESI( IMyI .FL o LNFj Cy(ce.Ii1l� This permit is hereby issuedunder the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By PERMIT EXPIRES ON Date COUNTY OF BUTTE -: DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: ASSESSOR PARC ER: D 4L Proposed Building Use: Building Inspector: Date: _e6 — At time of permit application, I was advised the followin data must be submitted nor to erdd roc�essm* - and/or issuance: P PP� � g P� P P g Date Received By ❑ 1 All items have been submitted.-------------------------------------------------- ------ ------------------------- llot plans, 3/4 sets, signed by the preparer of plans.---------------I---------r--- ---------------- ----� -- - ffComplete plans, 3/4 sets, signed by the preparer of plans. -- ----- --------------------5- 3�--eered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- Whergy eered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ Design Compliance and supporting documentation. -6-44 3r -- po-r-AA----------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. -------------------------------- ------------------------- El 8. Hazardous Material Form. ------------------------------------------------------------------------------------------ ❑ 9. Manufactured Home data and installation instructions including Tie Down Specifications. ------------------ ❑ 10 so' $ ------------------------------------------------------------------------------------- 1 � pact fees as shown on the attached schedule. ---------.'_- - ------------------ r� __,_ 5d California Department of Forestry plan approvaUfees. y ----------------------- ❑ good elevation certificate. ------------,---------------------------------------------------------------------------- Sanitation and plot plan approval 4Q Health Department. ------------------------------------------- ❑ 15. City of Chico plumbing permit. 1 ❑ 16. Plot plan and business license approval from the City of Biggs. ---------------------------------------------- ❑ 17. Planning approval for (A) Use: (B) Parking: -------------------------- El18. Contact Land Development about ElImprovements, ❑ Drainage, ❑ Legal Parcel. ----------------------- ❑ 19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- 020. Pre -inspection for required Request to Building Inspector on (Datil 021. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ El 22. -----------------------------------❑22. Workers' Compensation carver and policy number. ----------------------------------------------------------- ❑23.Owner-Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- ❑24. Letter of signature authorization. -------------------------------------------------------------------------------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing violations and/or expired permits. ---------------------------------------------------------------------- ❑29. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ . --------------- E130. Other: _______ Wh you issue the ermit, pr cess /as follows 11 Mail to owner, ❑M,ai/l�to�contractor. `►J Telephone I l and hold for pickup at © �rJ office. ❑ Deliver with inspector. i ��� Applicant: �"i Date:. Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Date: By:. Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: Index permit application for the above items numbered: 2. Additional items required: s-aA 6o ❑ Plan Check List Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Di ' ion �iu,nter, by Date: Plans reviewed by: Date: Plans approved by: Date: Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. TO: FROM: SUBJECT: Building Department Environmental Health Sanitation Clearance E.H. USE ONLY Plot Plan Attached Floor Plan Attached Sent to B.D. Owner Location AP# Plan Approved for: Sewage Disposal Water Supply- Public Private Well Clearance for dwelling. Other P (;-t � N -nom Va�% Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialipf Date •: a� Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and. 'return this information at your earliest opportunity .to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. I personally plan to provide the major labor and materials for construction of the proposed property improvement :YES NO[ ]. = 2. I HAVE[ Y]—HAVE NOT[ ] signed an ,application` fora budding permit for the . proposed work...; . 3. I have contracted with the -following person (firm) , to provide the -proposed construction: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide' portions of this work, but I have hired_ the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide some of the work but I have contracted (hired) the following peisons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK DATE: Z-- 2 4– a b - NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. May 1995 2.26 Ak 0.B.— I ..... .�:::;•Y: �.. :..;:.6:•J^.Y'•':'r /i:;y•. ..::.��t•,'•Yr::;..o}}x;;.:}::�Y"•}r'.::. f :;:: c' w' +u .: ::::::: . :tom ti%� �ry�.� i ' . n4 .•� :�:. ..� . •r::::x• 4 � <:.::•: Yn`.: .iA•,+,..n....vn... nS �\v.. � v., s:A.:�I����1�Mi',',�v L::•Y}YY�•::vn:::i:;: Y:r :J,.,:•.S.:L:i aiF :^.//.•'^h .: }v . .............. .\vn; +; :. x:{.. .nom .Pv.:{•{:: L: rvY• •. •x ..: .;�}r.. Y..: Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as.the builder of property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan o your own w th_ the exception of various trades that you plan to subcontract, you should be aware o e following information for our benefit and protection: 0 If you emplo or otherwise engage any•perso other than your immediate family, and the work (including materials and they co) is $300 or more or the entire project, and such persons are 'not licensed as contractors or su ontra ors, then you may an employer. 0 If you are an emplo yo ust re ' th the State and Federal Governments as an employer and you. are subject to several obliga ' including state and federal income tax withholding, federal social security taxes, workers compensation incur 'lability insurance costs, and unemployment compensation contnbutions. . 0 There may be financial risks for you if you do not carry out these obligations, "and these risks are especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors 'are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an `bwnerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned Sincerely, Michael C. Vieira, C.B.O. Manager, Building Inspection NOTE: This Oxner-Builder Information is required by Section 19830 of the California Health and Safety Code. May 1995 2.27 BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) �UII School DisInIlc Building Department No. A.P. Number �„ ,P ��U •- T� 9 Jurisdiction: City County T � Property Owner Ty •— '� r Property Location/Address / ",r ('A/XD Subdivision Residential Development No of Living Mobile Home Units. Installation Commercial/Industrial New Addition Building Lot No. I Sq. Footage 71(a Addition/ 'Supplemental to ' (Group R) Conversion Permit # *(No foundation inspection). ................................................................................................................ Sq. Footage Irioor rians reviewea oy acnooi uistnct Date (Including Exterior Roofed Areas) District Identification No. 4/ a �W-z,, 4 School District certifies that (Applicant) (Street Address) �} (Ph one Number) / (City) (State) (Zip Code) has complied with the requirements of Resolution No. representing 176 6 square feet. School District Representative Paid by Check # Remarks: �-� 0 --!) s— by payment of $ r JPA�ii2926 $ FULL MITIGATION $ Date WE Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the Califomia Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/981dmm • �` *Cxa��rT'`�^ ,F`:'ar'-�..s_�ir-.:�rasr„a•rt.�.x'.+tr.+Ni�r� :.r�<P+r"� �.��,r.�,.,.,,,j��• w ��;j�+T���1' 01-1110 ° K ., OROVILLE RVICE . I t OFFICE COPY M F dress `�� \`�}>� 0', ' \7 �/ GAS Meter By �— Dat ELECTRIC / ©� Meter By Dat pt COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-75411�7ERMMIT NO. (Rev. 12/96) APPLICATION AND PERMIT 0 r o ASSESSOR PARCEL NUMBER 068-210-109 ZONING AR BUILDING PERMIT OWNER HANS03 LLOYD TELEPHONE 5 3-4911 SO. FT, OCC. BUILDING VALUATION OWNERS MAIUNG ADDRESS 17 BUCHLQt AVE. OROVII.I.E CA 95966 CONTRACTOR'S NAME TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAIUNG ADDRESS Plan Checking Fee $ BUILDING ADDRESS 27 BUCHLIM AVE.,ORMUZ Energy Plan Checking Fee $ $ L PERMIT FEE $ LAT NO. SUBDIVISIONS NAME PARCEL MAP + PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY ' Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each uas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other,;❑• Describe Work: lbw 200 AMP SERVICE ' Gas piping system 1- 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 LES Main Service O20000AVORORLESSS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.PSING License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I Q I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. SO OR ADDNS. ( & ACC. BLDS. 3.SaFr; NON p61D. MULTI.Otm ET @7.50 8 LE Ol1'. OWER APPARATUCIR.S Ex. Occup. eA0 ® 1.00 OUTLET OR FDRURES Ex. Occup. OirTlEED75A gESIp.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE 4J. WORKERS' COMPENSATION DECLARATION ` 1 hereby affirm under penalty of perjury one of the following declarations: I ❑ I have and will maintain a certificate of consent to self -insure for workers'—Cooling compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier r Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) O_ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. / X 21-Lr`,n e - II/I10� 'It. J_ � Date ) - I 6 - G _ Signature` of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavatiQnsiaM 5_deep and demolition or construction of structures over 3 stories in h #_ \ MECHANICAL PERMIT Fling Fee 20.00 Heating Hood 6.50 Ventilation , L PERMIT FEE! $ Mobile Home Installation Fee $ Energy Inspection Fees $ occ CONST. TYPE TOTAL FEE $ 43.00 HAZ. D. FEES IMP FLOOD CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By �A6__ Date .� • ' _ PERMIT EXPIRES ON �� 0 (Date) Receipt No.�Z�i•�j q:E5 '� WHITE-D.D.S.-B.D. CANARY.AS�SOR PINK -INSPECTOR GOLDENROD -APPLICANT R COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT l-I'(off ASSESSOR PARCEL NUMBER 068-210-109 ZONING AR BUILDING PERMIT OWNER �77������77 ��,pp77 77��m L7tiiSEN 1.,1_,lliU TELEPHONE — 533-4913 SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS OWNE 27 BUCHLER AVE. OROVILLE CA 95966 CONTRACTOR'S NAME TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation is ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAIUNG ADDRESS Plan Checking Fee $ BUILDING ADDRESS 27 BUCHLER AVE. OROVIL E Energy Plan Checking Fee $ $ PERMIT FEE $ LAT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other Describe Work: NEW 200 AMP SERVICE Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W (920.00 PERMIT FEE $ ELECTRICAL PERMIT Fee 20.00 'LEFling 800VMain Service ZDOA OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. _ X _Date J� �J� — D _ Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavat 5'0" deep and demolition or construction of structures over 3 stories in h"n. Main Service TO 46.00 WEE200A CCU000A NEW CONST. DWELLING OCCUP. SO OR ADDNS. ( a ACC. BLAS. 3.50' "m�"N aDIDT. MULTI.O R @7,50 APPARATUS a SINGLE OUTLET CIR. @ I'50 Ex. Occup. OUTLET OR FIXTURES SAL @ .so POR Ex. Occup. ouTLEEDTSA RL.16.) EA. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE 43.000 MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 43.00 HAZ. I D. FEES IMP I FLOOD I CDF PARCEL I PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By / Date• �• PERMIT EXPIRES ON `�_ i . c) Date Receipt No. 32-4fZ '— WHITE-D.D.S.-B.D. CANARY -AS SOR PINK-INSP TOR GOLDENROD -APPLICANT (Rev. 12/96) COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754 APPLICATION AND PERMIT j,/ //PERMIT NO IMBER ZGMN°/�/�} BUILDING PIT ERM OWNER / \ r2.- TaEP►LONe SQ. FT. OCC. BUILDING VALUATION OWNER'S 1W UNG ADORE Jjjjjjjjp CONTRACTOR -9 NAME CONSTRUCTION LENDER LENDER'S MAILING ADDRESS ARCNRECT OR ENGINEER ARCWrECr OR ENGINEERS MAJUNO ADDRESS BUILDING ADDRESS 2—^ N el Total Valuatlon is Permit Fee ticking Fee Plan Checking Fee LOT NO. SUBDIVISION'S NAME PARCEL MAP PERMIT FE. PLUMBING PERMIT USEOFSTRUCTURE Each Tra SF ❑ Duplex ❑ Mobllehome Other Solar or heat um water heater _ ePocsv Water piping TYPE OF WORK Each gas water heater or New ❑ Addition ❑ Remodel ❑ Utilities ❑ InsOspation ❑ Otherv O - Gas i in stem outlets Describe Work: / A /P� Buildin sew 14µ.r J `� Mobile me S G W *PERMIT FEE PAID SRA -- SHERIFF OTHER AAk6VNT RECEIVED $_ 4�5 ---, 'RECEIPT NVMBER �37,,q JV,3 " TO 8E PVT INTO COMPUTER PERMIT FEE I $ ELECTRICAL PERMIT Main Service 20 OR LESS 200A OR LESS Main Service 200A TO loom NEW CONST. ( OWEIING OCCUP. OR ADONS. i ACC. BLD9. NON-RESID. MULTFOUTLF7 POWER APPARATUS 8 SINGLE OVrIEi CI0. Ex. OCCU OUTLET oR FORUREs I EX. OCCU FMO APPLNS. OR j OIlTLEig ESID. EA 1 Temporary Service i Mobile Home Facilities 0.,00I riling Fee 20.00 7.00 23.00 5.00 15.00 15.00 15.00 020.00 Feel 20.00 46.00 23.00 20.00 23.00 PERMIT FEE MECHANICAL PERMIT Fling Fee 20.00 MMObile 6.50PERMIT FE1e Instelletion Fee S Energy Inspection Fee y OCC CONST. TYPE i TOTAL FEES NAZ. D. FEES IMP FLDOD COF PARCEL I PO NO ISSUE This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. i By Date PERMIT EXPIRES ON Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing*your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed pro erty improvement : YES'] NO[ ]. 2.' I HAVE HAVE NOT[ ] signed an application for a building permit for the proposed work. 3. I have contracted with . the following person (firm) to provide the proposed_ ' construction: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person -to coordinate, supervise, and provide the major work: NAME: ADDRESS • CITY• PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: F '" NAME ADDRESS PHONE TYPE'OF WORK•• SI_ GNED: PROPERTY OWNER: //Zv/ SOCIAL SECURITY NUMBER: DATE: NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. OVER C -, Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: . 0 If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. 4 0 There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended. for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an •"ownerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. „ Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned., .' ,., Sinc'erel Michadl C. Vieiia, C.B.O. Manager, Building Inspection _ °4 NOTE: This Owner -Builder Information_is required by Section 19830 of the California Health and Safety Code. OVER OF • Y ri Eutte Count L A N D O F N A T U R A L W E A L T H A N D B E A U T Y BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE • OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (530) 538-7541 FAX: (530) 538-2140 Re: Building Permit # 00-1197 Expiration Date: 6-12-01 A.P. # 068-210-109 With reference to the above subject, our records indicate that your building permit expires on the above date and your permit falls into one of the category marked below: Permit work started, but not completed. Permit may be renewed for 1/2 the original building permit fee (plus a $20.00 filing fee). The renewal permit will extend the building permit for an additional year from the original expiration date. Should you not renew your permit within 30 days of the expiration date, all work must cease until a new building permit has been issued. For your convenience, we are enclosing a renewal application form and owner -builder form to be completed and signed by you where indicated and returned to this office together with the fee shown. Please return all copies of the application form. [ ] No inspections have been made on permit work. Inspections are required to verify code compliance. We are unable to renew a permit where the work has not been started and inspected prior to permit expiration. After expiration of your permit, no work may be started until a new permit has been issued. [ ] A final inspection has not been made on permit work. Final inspection approval is required before occupancy. Our field inspector has verified that the building is occupied. Occupancy must cease until a final inspection can be made and final approval given. You have 30 days to voluntarily cease occupancy or to present an acceptable plan for abatement or corrective actions to be taken by you. If 8v6,ffPVs are in error or should you have any questions concerning this matter, please contact the office. Thank you for your prompt attention concerning this matter. YWrs very truly, C. Vieira, C.B.O. Building Inspection MCV:lt Attachments Chico Office - 411 Main Street, Chico / 891-2751 AMMONS TO RESIDENTIAL, BUILDINGS ENERGY SHEET PACKAGE COMPLIANCE Owner Climate Zone Permitil 17 Floor Area 7 �---- •, The following den sbowing mandatory and rO4okW feetwes shell be Installed for addhiom to dwaWass. Additions to dwellings include room additions, converting gauges and patios to livtng areas, house moves that add footage and attic conversloas,end i any space dant is es lstmg non-eonditlorrod space that is ConvMod to conditioned Vol is not mdudsd. spm. Remodeling of odsting conditioned Climate Zones 1 l and 160 Component 100 sift 101-499 500 <1000 sgft Ceiling 1°s. R-19 t "R 38�, R-38 Wall �- R-15 R 15 R-15 Floor Ins. ENR (R-19 R-19 Slab Edge Ins, NR. R-7 NR, R-7 i Glass (i) .75 65, .60 i Max. Glass -16%+Removed16•/. +gemoved Shading Coe@'(S� 66 — - .66 Shading Coeff (W&E) NR .40, .66 .40, .66 MiTitA,owed R S% Raised 5% Raised 20% Slab 20aYe Slab Not All Not Allowed Not Allowed AFUE 78 o AFU'E 79% eAFilE 78 /oHSPF 6.8 HSPF 6.8 HSPF 6.8 Heat P=p Package HSPF 6.6 HSPF 6.6 HSPF 6.6 WFeawm,*j t Sys. SEER 10.0 SEER 10.0 SEER 10.0 age SEER 9.7 SEER 9.7 SEER 9,7 f Wtr Htrs Allowed w/ cafes. Allowed w/ cafes. Allowed w/ cake. --j *OneolumA a req both Zones. 2nd /Etemarks loose Fin huuWon (Deus y) VVi"atTC M16�)awV dotns.eatitied wlndorra, nuDcinu QEPA� 0 M" Pa voiform Mochoodeal Code - Ck to RU liahfing Kitchen and Bath not Ian than 40 LumcWWan � +� Desitin Canplisnce Soatatnent The abort buiMns damn enoets roouiremenu 5f Title :+. Parts n awV 6 of the Cdifomial Code of Repfuiens• (Property owner/contractor) CDF FIRE SAFE REQUIREMENTS 40�/a AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County. local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. �(] 1272.00 Maintenance of Defensible Space. To ensure continued / maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards �(J 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other app-artezant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [X] 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [�Q 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. M 1273.05 Turnarounds. If required, will have a minimum turning /` radius of 40 feet from the center of the road. [fid 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [ 1270.10 Width.:All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of - 3--, t AP # PERMIT # NAME X' 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in 1•ength, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet,•.turnouts shall be provided no. more than 400 feet apart. �XJ 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in -length and shall be within 50 feet of the.building. 1273.11 Gates 4CJ 1. Gate entrances shall be at least two feet wider than the roadway it serves. �] 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. 'PK'] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. 1. All parvels 1 acre atzd larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from 411 property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local .jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r fi.ial inspection of a building permit. Page 2 of 3 _. AP # DCe -111,57z e�lc_t� PERMIT ## NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves If Building Setback is Less Than 15 Feet. ,5hoose any.3 of the following: Metal or no doors on.side toward property line with insuffi- cient setback Class A or B roof with enclosed eaves -,Interior automatic sprinkler system per NFPA 13D Glass area not,to exceed 10% of wall area toward property line with insufficient setback Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Dat Sign tur Page 3.of 3 (NANS0531-HANSEN/ADDITON - Al 22' COHN' TOP CHORD 2x4 DF -L #1 80T CHORD 2x4 OF -L J1 WEBS 2x4 DF -L Standard �IPLATES DESIGNED FOR GREEN LUMBER PER NDS -97 TABLE 1.3.3. A. Ca C"), C CT O E~ V 'A A O a A. A W 9=4 W w z c.5 z w THIS DWG PRFPARFa FRfU4 CONPIITFD TUDIIT nnenc A nYUCucrnuc% oIn—TT nW Tnncc urn IN LIEU OF STRUCTURAL PANELS OR RIGID CEILING USE PURLINS: TO BRACE TC @ 24.00" OC. BC Q 72.00' OC. DEFLECTION MEETS L/240.00 LIVE AND L/180.00 TOTAL LOAD. 10 PSF BC LIVE LOAD PER UBC. W4X4 is nc.JA4thl) la - W2.5X4 m W2.5X4(Al) IEa +8-0-0 0 2 L<2 -o -oat 1z2 0 D-,1 L< 11-0-0 I 11-0-0 I 22-.0=O_O.v_e.r 2 Supports R-830 W-5.5' R-830 W-5.5' A. PLT TYP. Wave TPI -95 R Desi n Criteria: TPI STD 19 CA - 1 - - R'- Scale -.25"/Ft. •'YARN IMG'• TRUSSES REQUIRE EXTREME CARE !A FABMICATIOM. NANDlf A6, SII"PING. INSTALLING AND O %I116. REFER TO 818.91 (HANDLING INSTALLING AND BRACING), PUBLISHED BY TPI (TRUSS PLATE E TC LL 16.0 PSF REF R427--16820 C=)PESTITUTC. 367 D'ONOFIIIO OA., SUITE 200. MADISON. WI 53719). FOR SAFETY PRACTICES PRIOR TO C==) FORMING THESE FUNCTIONS. ONLISS OTHERWISE INDICATED, TOP CHORD SHALL HAVE PROPERLY ATTACHED N TC DL 10.0 PSF DATE 06/01/00 STRUCTURAL PANELS, BOTTOM CHORD SMALL HAVE A PROPERLY ATTACHED RIGID CEILING. ••IMPORTANT• FURNISH A COPY OF THIS DESIGN TO THE INSTALLATION CONTRACTOR. ALPINE ENGINEERED � 1 � BC DL 7.0 PSF —6—RW CAUSR427 00153002 r: PRODUCTS, INC. SHALL NOT 8E RESPONSIBLE FOA ANY DEVIATION FROM THIS DESIGN; AMY FAILURE TO 7A L P I N E BUILD THE TRESSES 14 CONFORMANCE WITH TPI; OR FABRICATING, HANDLING. SHIPPING, INSTALLING AND BRACING Of TRUSSES. THIS DESIGN CONFORMS WITH APIl1CA6lf PtOVTSTONS Of NDS (NATIONAL OEf1611 BC LL 0.0 PSF CA -ENG AE8/CWC .�' SPECIFICATION PUBLISHED BY THE AMERICAN FOREST AND PAPER ASSOCIATION) AMD TPI. ALPINE CORRECTORS ARE MADE OF 2O0A ASTM A631 6440 6AL1. STEEL. EXCEPT AS NOTED. APPLY CONNECTORS TO TOT. LD. 33.0 PSF SEAN - 17891 `7 EACH FACE OF TRUSS. AND UNLESS OTNERNISE LOCATED ON THIS DESIGN. POSITION CONNECTORS PER ~' p,,,.� DRAWINGS 160 Aq. THE SIAL ON THIS CRAVING INDICATES ACCEPTANCE Of PAOFESSIORAL EN6IMECRING OUR .FAC . 1 .25 FROM GA NPl>>S8CZfMMtk A958 O18' 14C. COMPO"ENTIFORYANYLELY PARTICULARETRUSS BUILDINGO19 THETCESICIRESPONSIBILITY Of THE�813ILDIN6SHOWN. THE 1DESIGNETY AND R. PER THIS M S"anmelDl CJL95828 MSI/TPI 1.1„S SECTION Z. K SPACING 24.0” V. fj BUTTE COUNTY DEVELOPMENT SERVICES Complainant: Address: Phone Number: Other Comments: Inspector must draw a plot plan with all building locations: 4 Additional comments from Inspector: ........::..:..:.. . e>�abaveere orm:: ,..�: ..:k%.;;....<.. . Inspector must draw a plot plan with all building locations: 4 Additional comments from Inspector: ter-., �a S� � i,,.•.,.1TY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION ---Cejnty Center Drive - Oroville California 95965 - Tele hone 101M 538-754 PERMIT (Rev. 12/96) APPLICATION AND PERMIT 7 f�— ASSESSOR PARCEL NuMBFA (/�^Oq V ZONING BUILDING PERMIT OWNER ERS •DRE 9 COpQ OR' f CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER LENDER'S MNLING ADDRESS ARCHITECT CH ENGINEER ARCHITECT OR ENGINEERS MODUNG ADDRESS BUILDING ADDRESS 01 LOT NO. SUBDNISIONSNAME USEOFSTRUCTURE SF � Duplex ❑ Mobilehome ❑ Other LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of -Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is Issued. I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date 7' C/ % Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60' deep and demolition or construction of structures over 3 stories in height. SO. FT. I OCC. BUILDING VALUATION Fireplace C TYPE OF WORK ELECTRICAL PERMIT New49 Addition ❑ Remodel E3 Utilities ❑ InItallation Other Describe Work: 1.�.— j,❑, d 1& - �I LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of -Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is Issued. I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date 7' C/ % Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60' deep and demolition or construction of structures over 3 stories in height. SO. FT. I OCC. BUILDING VALUATION Fireplace C Total Valuation is ELECTRICAL PERMIT Filing Fee 20.00 Permit Fee 23.00 Plan Checking Fee _7M'l Energy Plan Checking Fee $ a3 NEW CONST. DWELLING OCCUP. OR ADONS. a ACC. BIDS. $ , -;?�Z PERMIT FEE $ r PLUMBING PERMIT Filing Fee 20.00 Each Trap 4 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.0 Gas piping system 1 - 5 outlets 15.00 IS Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE 109,6U ELECTRICAL PERMIT Filing Fee 20.00 Main Service 000v OR LESS 200A OR LESS 23.00 Main Service 200A To 1000A 46.00 Sg,/C NEW CONST. DWELLING OCCUP. OR ADONS. a ACC. BIDS. 3.SCSO. FT. NEW CONS . MULTI.OUTLET NON-RESID. 97.50 POWER APPARATUS a SINGLE OUTLET CIR. Ex. OCCU OUTLET OR FIXTURES 20 O 1.00so BAL . Ex. Occup. ouTLEE°TSA RESID.°EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 1 20.001 Hood1 6.50 Ventilation 1 PERMIT FEE $ Mobile Home Installation Fee s Energy Inspection Fee $ OCC CONST. TYPE TOTAL FEE $ r HAZ. 10. FEES I IMP I FLOOD I COF PARCEL I PD JIID I ISSUt This permit is hereby issued under the applicable provisionf e of the Butte County Code and/or Resolutions to do wr indicated abovei%1 which fees have been paid. .S�ICv� By ReceiptNo. 0���1����-�ys I PERMIT EXPIRES ON ln c v4ITF.n .a n —re�1 v. cccSSOR PINK -INSPECTOR GOLDENROD -APPLICANT Date COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE 9l0zd-�P -Vo - /b 9 OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. U Cy cz I Date "Z Inspector REV 1 2 March 18, 1998 Lloyd Hansen 21 Buehler Avenue Oroville, CA 95965 Dear Mr. Hansen: ,quite C LAND OF NATURAL WEALTH AND 'BEAUTY BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 533-2140 RE: Request for Refund (A.P. #068-210-109) I received your request for refund of building permit #97-1405 (for a second dwelling). The fees you paid for this permit included only plan checking and filing. Plan checking and filing fees for work plan checked cannot be refunded; therefore, a refund cannot be made for this permit application. Should you have any questions concerning this matter, please contact me at this office. Yours very truly, C. Yieira, C.B.O. Building Inspection MCV: ahb -3 March 18, 1998 Lloyd Hansen 21 Buehler Avenue Oroville, CA 95965 Dear Mr. Hansen: ,quite C LAND OF NATURAL WEALTH AND 'BEAUTY BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 533-2140 RE: Request for Refund (A.P. #068-210-109) I received your request for refund of building permit #97-1405 (for a second dwelling). The fees you paid for this permit included only plan checking and filing. Plan checking and filing fees for work plan checked cannot be refunded; therefore, a refund cannot be made for this permit application. Should you have any questions concerning this matter, please contact me at this office. Yours very truly, C. Yieira, C.B.O. Building Inspection MCV: ahb REFUND CLAIM APPLICATION F CLAIMANT'S NAME MAILING ADDRESS ASSESSOR PARCEL #: RECEIPT NUMBER(S) Request a refund of fees paid on the above receipt number(s) for the following reasons: e Please refund any applicable fees in the following categories: (Check those categories ` which you wish to have refunded.) .; ( ) Building Permit Fees ( ) Sheriff Fees 6 " X 4 ( ) SRA Fees (CDF Fire Planning) ( ) Urban Area Fees Disposition of Plans: i Plans returned to me at counter ` 3 f ( ) Please mail plans to me at above address. ( ) Please dispose of plans. IGNATURE ��W DATE __ 3 _ /9- — % � PLEASE DATE AND SIGN THE ATTACHED COUNTY OF BUTTE GENERAL CLAIM FORM. DO NOT COMPLETE ANY OTHER INFORMATION ON THAT FORM. FOR BUILDING DIVISION USE: . Receipt Information: Number: Date: Issued To: _ Amount: Fees Retained: /�� ��� I AN Processing Fee:' �a Bldg Filing Fee: Plbg Filing Fee: , `.It Ip Elec Filing Fee: f Mech Filing Fee: ` $ Energy P/C Fee: $ Plan Check Fee: $ Inspection Fee: $ SRA Fee: $ Total Amount Retained $ TOTAL REFUND DUE $ COUNTY OF BUTTE Oroville, California GENERAL CLAIM CLAIMANT: ADDRESS: CITY & STATE: DATE OF CLAIM: IMPORTANT.• SEE INSTRUCTIONS SUBMIT CLAIM TO DEPARTMENT RECEIVING GOODS OR SERVICES ON REVERSE SIDE DATE DESCRIPTION OF CLAIM (DESCRIBE FULLY TO AVOID DELAY) AMOUNT IF- I TOTAL I, the undersigned, declare under penalty of perjury that the services or articles claimed have been performed or delivered, and that this claim is true and correct as stated. Dated this day of , 19_, at Calif. Signature of Claimant I, the undersigned, hereby certify that, to the best of my knowledge, the services or articles specified above have been performed or delivered and that there is a Budget Appropriation [ ] or Specific Board Approval [ ] (Check one) for the same. Dated this day of , 19_, at Calif. Department Head or Authorized Deputy Dept. Code Exp. Code PAYABLE FROM FUNDDe t. Code Exp. Code PAYABLE FROM FUND Dept Code Exp. Code PAYABLE FROM FUND DO NOT WRITE BELOW THIS LINE - AUDITOR'S USE ONLY DEPT. & SUB. PROJ. SUB. OBJ. CLAIM NO. INV. NO. INV. DATE ENCUMB. GROSS AMT. INSTRUCTIONS TO CLAIMANTS All claims against the county must be itemized, giving dates and character of service rendered or work performed, quantities, description and unit prices of articles furnished or delivered. Claims must be certified by the claimant and submitted to the Department head for approval. Upon approval the Department head will forward claim to County Auditor for payment procedure. Do not file with the County Auditor first. Claims should be presented to officials for approval immediately upon completion of services requested or material ordered. Compliance with above will expedite payment of claim, failure to do so may delay payment considerably. 8/27/97 LLOYD & MAXINE HANSEN 21 BUEHLER AVER OROVILLE, CA 95965 Re: B.P.#97-1405 L/ // P L A N D O F N A T U R A L W E A L T H A N D B E A U T Y BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 With reference to the above subject, attached is: [x ] Plan Check List. [ ] Red Marked.Calculations [ ] Red Marked Plans [X ] Other A.P.# 068-210-109 Action Required: [X ] Comply with Plan Check List [ ] Resubmit Plans with Revisions As Required [ ] Return All Original Materials and Revised Plans to the Building Department [X ] Other Should you have any questions, please contact this office at the address or phone number listed above. Sincerely, MARTHA WHITNEY - PLAN CHECKER PERMIT APPLICANT LLOYD & MAXINE HANSON ASSESSOR PARCEL NO. 068-210-109 PERMIT NO. 97-1405 DATE 8/27/97 The above referenced building plans were reviewed by this office. Provide additional information and/or make appropriate revisions to plans, specifications, and calculations as follows: PLANS RETURNED 8/27/97 1. PROVIDE LOCATION OF BOTH WATER HEATERS. THEY ARE TO BE POINT OF USE PER ENERGY CALCS. 2. WINDOW SIZES HAVE BEEN LEFT OFF PLANS PROVIDE ALL WINDOW SIZES. 3. HOW IS ONE HOUR OCCUPANCY SEPARATION MAINTAINED BETWEEN UPPER/LOWER STORY. 4. PROVIDE HEADER SIZE AT GARAGE DOOR. 5. PROVIDE FLOOR FRAMING PLAN. SHOW BEAM AND DECK JOISTS. SHOW POST (WITH SIZE) LOCATION. 6. PROVIDE FOUNDATION PLAN. SHOW SPREAD FOOTINGS FOR BEAM. SHOW STEEL RE- QUIRED FOR ALTERNATE BRACED WALL PANELS. SHOW SSTB LOCATIONS. SHOW HOLD DOWN LOCATIONS. 7. PROVIDE ROOF FRAMING PLAN WITH MEMBER SIZES. SHOW.BEARING. SMALL DETAIL ON PLANS SHOWS SITE-BUILDT TRUSSES. ALL TRUSSES REQUIRE ENGINEERING. PROVIDE CONVENTIONAL CONSTRUCTION OR ENGINEERED TRUSSES. 8. BRACING 1. SHOW REQUIRED BRACING LOCATION, METHOD, MATERIAL AND ATTACHMENT ON PLANS. 2. LATERAL BRACING SHOWN ON PLAN IS FROM SEC 2326.11.4 OF UBC. THIS METHOD MAY NOT BE USED ON THE SECOND STORY OF A TWO STORY STRUCTURE. ADDITIONALLY AS WE TALKED PREVIOUSLY YOU HAVE A ROOF LINE THAT DOES NOT BEAR ON A BRACED W.,ALL LINE AND IS AN UNUSUALLY SHAPED STRUCTURE BY CODE. PROVIDE A LATERAL ANALYSIS OF ADDITION FOR AREAS RATED ON PLAN. PLEASE PICK UP 2 SETS OF PLANS TO MAKE REQUIRED CHANGES. MARTHA WHITNEY - PLAN CHECKER If you wish to discuss any requirements, you may contact me at (916) 538-7541 between 1:00p.m. and 4:00 p.m., Monday through Thursday. ,r r 11/12/97 LLOYD & MAXINE HANSEN 21 BUEHLER AVE OROVILLE, CA 95965 Re: B.P.#97-1405 1;uttc count L A N D O F N A T U R A L W E A L T H A N D B E A U T Y BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE. CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 533-2140. With reference to the above subject, attached is: [ x] Plan Check List [ ] Red Marked Calculations [ ] Red Marked Plans [ ] Other A.P.# 068-210-109 Action Required: - *I . [ x] Comply with Plan Check List [ ] Resubmit Plans with Revisions As Required [ ] Return All Original Materials and Revised Plans to the Building Department [ ] Other Should you have any questions, please contact this office at the address or phone number listed above. Sincerely, MARTHA WHITNEY - PLAN CHECKER PERMIT APPLICANT LLOYD & MAXINE HANSEN ASSESSOR PARCEL NO. 068-210-109 PERMIT NO. 97-1405 DATE 11/12/97 The above referenced building plans were reviewed by this office. Provide additional information and/or make appropriate revisions to plans, specifications, and calculations as follows: 1. REQUIREMENTS FROM ENGINEERING MUST BE KEYED ONTO PLAN. (ENGINEERING FROM MR. BROWN AND GMA) 2. TWO 2X12'S USED AS BEAM MUST BE NAILED PER TABLE 23-1-Q OF THE UBC. NOTE PLAN. 3. PROVIDE ADDITIONAL INFORMATION ON HANGER FOR FLOOR JOISTS? IS THIS A "SIMPSON" OR OTHER, IF SO CALL OUT SPECIFIC HANGER FROM CATALOG. IF NOT PROVIDE CALCS TO SHOW IT CAN CARRY THE T nADg .IMPOSED_, 4. ROOF FRAMING PLAN IS INCOMPLETE'AS SUBMITTED. WHAT IS DIRECTION OF CEILING JOISTS FOR BOTH UPPER/LOWER ROOFS. WHERE DO THEY BEAR? WHAT IS BEAM SIZE BETWEEN KITCHEN AND DINING ROOM? PROVIDE CONSTRUCTION DETAIL AND ATTACHMENT FOR RAFTERS & CEILING JOISTS BEARING ON BEAM. HIP RAFTER -SHALL BE NOT LESS IN DEPTH THAN THE CUT END OF RAFTER. SIZE ALL MEMBERS OF ROOF FRAMING SYSTEM. PROVIDE CALCS FOR BEAM CARRING BbTH ROOFS. 5. DETAIL B UNCLEAR AS TO ITS USE. IS THIS THE WALL BELOW UPPER ROOF? PLEASE EXPLAIN. 6. 2X4 FRAMING IS SHOWN ON PLANS AND ENERGY CALCS SHOW 2X6 FRAMING. COORDINATE. (UPPER LEVEL) 7. LIGHT BLINDS ARE REQUIRED TO BE INSTALLED IN ALL WINDOWS, EXCEPT DINING ROOM. THESE MUST BE INSTALLED BEFORE FINAL OF BUILDING.. 8. POINT OF USE WATER HEATERS MUST BE LOCATED WITHIN 8' OF USE TO USE ENERGY CREDIT. PROVIDE LOCATION OF WATER HEATERS. IF NOT LOCATED PROPERLY, ENERGY CALCS WILL NEED TO BE REVISED. 9. LATERAL PLANS WILL BE REdIEWED BY OU't ENGINEER. 10. PROVIDE HEADER SIZE AT GARAGE DOOR. 11. HOW IS OCCUPANCY SEPARATION MAINTAINED -BETWEEN UPPER AND LOWER STORY? MANY OF THESE QUESTIONS HAVE BEEN ASKED ON PREVIOUS PLAN CHECK LETTER AND ARE STILL NOT ANSWERED. I AM ENCLOSING A COPY OF PREVIOUS PLAN CHECK LETTER. ANY DETAILS FROM PREVIOUS SUBMITTALS THAT YOU ARE NOT USING IE: 3 2X12 FOR FLOOR BEAM ARE TO BE REMOVED OR CROSSED OFF PLAN. . If you wish to discuss any requirements, you may contact me at (916) 538-7541 between 1:00p.m. and 4:00 p.m., Monday through Thursday. MARTHA WHITNEY - PLAN CHECKER i 75. LAND OF NATURAL WEALTH AND BEAUTY Lloyd Maxine Hansel 21 Buehler Avenue Oroville, CA 95965 Re: Single Family Residence APN 068-210-109 With reference to the above subject, attached is: [x] Plan Check List [ ] Red Marked Calculations BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 533-2140 Date: 11/19/97 Permit #97-1405 [ ] Red Marked Plans .Other Action Required: [x] Comply with plan check lists [x] Submit revised plans as necessary (three copies minimum) [x] Submit additional calculations as requested (two copies) [ ] Return all original materials & revised plans to the building department Should you have any questions, don't hesitate to contact me at (916) 538-7541 Monday through Thursday between 1:00 P.M. and 4 P.M.. Sincerely, George R. Kellogg - Plan Check Engineer cc Alan G. Br n Barnhart- Brown & Associates 2060 Park Avenue Oroville, CA 95965 Gerald A. Mele Gerald Mele & Associates 7337 N. First Street, Suite 110 Fresno, CA 93720 1 M SUPPLEMENTAL PLAN CHECK LIST Permit Applicant: Lloyd & Maxine Hansen Date: 11/19/97 Permit #97-1405 The above referenced plans were reviewed by this office. Provide additional information and/or make revisions to plans, specifications, or calculations as follows: Regarding structural calculations provide by Mr. Alan G. Brown: 1.1) Show engineering design from the referenced calculations on the plans, including the glu-lam specified on page 8 of the calculations. Provide material specification for engineered items including concrete, wood, etc. and, show on the plans. 2. Regarding structural calculations provide by Mr. Gerald A. Mele: 2.1) Provide load path details for the transfer of lateral forces from shear wall W5 to the foundations. Revise the plans to show the actual beam proposed (glu-lam rather than built-up beam?) 2.2) The detail shown on page 27 of the calculations refers to an attachment and beam by others. Please provide the attachment and beam designs. If other than conventional construction as defined by the Uniform Building Code(UBC), provide supporting engineering analysis. All engineered plans are to be stamped and wet signed by the licensed design professional responsible for the design. 3. Regarding the plans provided by Mr. Lloyd Hansen: 3.1) Please indicate the extent and construction details for the concrete slab for the proposed addition. 3.2) Detail how the proposed addition's walls will be attached to the existing structure 3.3) The first floor - floor plan shows windows in shear wall W21, by Mr. Mele. Please revise the engineering to reflect this or eliminate the windows from the plans. 3.4) It appears that the studs proposed for the back portion of the addition do not meet the requirements of Table 23 -I -R-3 of the UBC, such that studs with laterally unsupported height greater that 10 ft. Please provide lateral support or engineering analysis verifying proposed design will perform adequately. 3.5) Revise the front elevation to show all of the proposed addition F ' 1 4. Regarding the plans provided by GMA: 4.1) Provide an engineered design and gravity load path design for beam in line with shear wall W6 which supports the second floor and roof (shown as "BEAM NOT BY GMA" on the referenced 2nd Floor Plan on Sheet S-1). Provide information requested in Martha Whitney's plan check letter dated 11/12/97 and remaining items on the Permit Application Data Sheet. 6. A County soils map indicates that the site area has the potential for highly expansive soil. Please provide identification of the soil per the classification system indicated in Table 18- I -A of the Uniform Building Code. Investigate whether the subgrade material of the house foundation is expansive. Revise the foundation design as necessary to account for subgrade soil conditions, reflecting actual expansion potential. The foundation design for concentrated loads has assumed an allowable bearing of 1500 psf. To have this allowable, per Table 18 -I -A, the subgrade material would have to be class 4 or better. If this is not the case, please revise the foundation design as necessary to reflect the actual situation or provide a Geotechnical Investigation justifying the higher allowable value used. 3 11/12/97 LLOYD & MAXINE HANSEN 21 BUEHLER AVE OROVILLE, CA 95965 Re: B.P.#97-1405 Ll -1-1- P- L A N D O F N A T U R A L W E A L T H A N D B E A U T Y BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE. CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 533-2140 With reference to the above subject, attached is: [ x] Plan Check List [ ] Red Marked Calculations [ ] Red Marked Plans [ ] Other A.P.# 068-210-109 Action Required: [ x] Comply with Plan Check List [ ] Resubmit Plans with Revisions As Required [ ] Return All Original Materials and Revised Plans to the Building Department [ ] Other Should you have any questions, please contact this office at the address or phone number listed above. Sincerely, MARTHA WHITNEY - PLAN CHECKER PERMIT APPLICANT LLOYD & MAXINE HANSEN ASSESSOR PARCEL NO. 068-210-109 PERMIT NO. 97-1405 DATE 11/12/97 The above referenced building plans were reviewed by this office. Provide additional information and/or make appropriate revisions to plans, specifications, and calculations as follows: 1. REQUIREMENTS FROM ENGINEERING MUST BE KEYED ONTO PLAN. (ENGINEERING FROM MR. BROWN AND GMA) 2. TWO 2X12'S USED AS BEAM MUST BE NAILED PER TABLE 23-1-Q OF THE UBC. NOTE PLAN. 3. PROVIDE ADDITIONAL INFORMATION ON HANGER FOR FLOOR JOISTS? IS THIS A "SIMPSON" OR OTHER, IF SO CALL OUT SPECIFIC HANGER FROM CATALOG. IF NOT PROVIDE CALCS TO SHOW IT CAN CARRY THE TnAns TMPn4FT)_ 4. ROOF FRAMING PLAN IS INCOMPLETE AS SUBMITTED. WHAT IS DIRECTION OF CEILING JOISTS FOR BOTH UPPER/LOWER ROOFS. "WHERE DO THEY BEAR? WHAT IS BEAM SIZE BETWEEN KITCHEN AND DINING ROOM? PROVIDE CONSTRUCTION DETAIL. AND ATTACHMENT FOR RAFTERS & CEILING JOISTS BEARING ON BEAM. HIP RAFTER -SHALL BE NOT LESS IN DEPTH THAN THE CUT END OF RAFTER. SIZE ALL• MEMBERS OF ROOF FRAMING SYSTEM. PROVIDE CALCS FOR BEAM CARRING BOTH ROOFS. 5. DETAIL B UNCLEAR AS TO ITS USE. IS THIS THE WALL BELOW UPPER ROOF? PLEASE EXPLAIN. 6. 2X4 FRAMING IS SHOWN ON PLANS AND ENERGY CALCS SHOW 2X6 FRAMING. COORDINATE. (UPPER LEVEL) 7. LIGHT BLINDS ARE REQUIRED TO BE INSTALLED IN ALL WINDOWS, EXCEPT DINING ROOM. THESE MUST BE INSTALLED BEFORE FINAL OF BUILDING. 8. POINT OF USE WATER HEATERS MUST BE LOCATED WITHIN 8' OF USE TO USE ENERGY CREDIT. PROVIDE LOCATION OF WATER HEATERS. IF NOT LOCATED PROPERLY, ENERGY CALCS WILL• NEED TO BE REVISED. 9. LATERAL PLANS WILL BE REdIEWED BY OU R; ENGINEER. 10. PROVIDE HEADER SIZE AT GARAGE DOOR. ' 11. HOW.IS OCCUPANCY SEPARATION MAINTAINEY-BETWEEN UPPER AND LOWER STORY? MANY OF THESE QUESTIONS HAVE BEEN ASKED ON PREVIOUS PLAN CHECK LETTER AND ARE STILL NOT ANSWERED. I AM ENCLOSING A COPY OF PREVIOUS PLAN CHECK LETTER. ANY DETAILS FROM PREVIOUS SUBMITTALS THAT YOU ARE NOT USING IE: 3 2X12 FOR FLOOR BEAM ARE TO BE REMOVED OR CROSSED OFF PLAN. If you wish to discuss any requirements, you may contact me at (916) 538-7541 between 1:00p.m. and 4:00 p.m., Monday through Thursday. MARTHA WHITNEY - PLAN CHECKER STRUCTURAL CALCULATIONS FOR Client: Barnhart -Brown & Associates Project: ansen Residence ILateral Analysis N1, Oroville, CA Mix Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 ,FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 7.1(42 \ 10 9.5. E. \ I OF 2-7 r =51GN PARAMETERS / MATERIALS GOVERNING GODE 5E 15M I G ZONE WIND CONCRETE RMAR — COUNTS 1994 UNIFORM 6U I LD ING CODE ( U6G ) 04 n 75 MPH 6A51 G EXP05URE 118n W I105PEED, 2-5K51 (2, 5 QO P51) * 3 GRADE 40, * 4 & LARGER GRADE 60 K VERT I CRI. I;OADS _ — W lATt:fAl- S17--GM1L AIVALYsi> ROOFING 3.0P5= PL1 OrV . 2.0 psr- RAFTERS 2-2- p5F I Nsti LAi'I ON /`RISC.. 3.0 psF 11,'7 - 195>= USE 15 P5F MIN . U6a 6 psF FOR WAu-s USE 13 P6F - 3.0 p5F(1200FNQ = 12. NSF FOP- 03 GERALD MELE & ASSOCIATESN 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435.1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE 3 Jul raw@ I k1m. UPPER I,Ev1=L 9 ml Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 2 GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 n In It\NVR LlEVLL MJA Consulting Engineers GERALD A. MELE, PE, SE . MARTIN R..INESS, PE, SE I GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435.1169 5 -WINO P = Ce," `61 \' P= •G7x14.4GP�" IxC�� = 9.68G�, P5F p = 72 x 14,4& Sr -x) x Gur = 10.4 Gy, PSF Fwp, _ 10.4P5Fx r(19'x.4�X.8 r(IaxZ')x.5 t(7x10.5�)n(,3t,7) ] _ 1+660 I -I L FWuz = Ip,4P51=x[(WAV)x,5+(14'x7')x,3 11 -7] = ig64�` �-1 Fwn3 = �j.68P5fxr(14'x12')x(,St.S)� = 280 1-I L (0198.41 FW01 2-2 = 10.4 r5FxP.�+(7.5'z�`)x 5 f�cld5')xi.3r.�) 1zj = 1024* 5,,,v v2. 2-2- = 10,4954: Px2'xV+II'x3')X. BI = 1057" FW t.3- i q. 6 $ Psr,� [C 24'A )7 -')X • a -t- (13.5 x G') x. $ ] = 2056 9g3R# — 50-wic, V:- A n 2.75X1,0 = 0.183 w 6 \/nl = 0.183x [05P5Fx21'A14') + (oP3F�c(I�+�x 6't 12'x(,"t 75')eG')] = )OG04 VD2. = 0- 19`31( [(15PsFx I4x I2') -F �,PSFx 02'x6'+ Wx6 _ &32'* Un.3 = 0.153XUI2.P5FxIQ'x375't 6F5Fx.(CO7.5't6'x24'+4.5,xfL)] 202`1. 3721 m4c Consulting Engineers . GERALD A. MELE, PE, SE. MARTIN R. INESS, PE, SE WIND GOVERNS 130TV OIRtIRGTIONS GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 rd - 5HEI* WALL PLAN uhpf�K LCL 8� NO T 13Y GERALD MELE & ASSOCIATES 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435.1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE '7 Ai A GERALD MELE & ASSOCIATES 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435.1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE '7 — SHEAR WALL. PLO LOdX�-:12 �EVR- mil Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 r - 1-1 01> ;CTION UPPF� triV5L 01 - WALL SMI A; TH)N& w - W3u-(Z TYP. 'rop RATE .5pL4C,F VY I .. - 2A OLOCKING w/cs 22 MJA Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE O Y r 7. S' vY3t+ q.33' Trnnx = IQ65x 1� = 210 # Or W I - 4. 5' )K (o = 2 75# W34 = 5,33'(7q=61) =q6# TOP EE OK 3?� GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 I - 1-I 1)19>:('n0N 102 - I `( K KWF sH!✓� ttM7 7/rb "APA. MTPV SW-TNN17) 2Q/l(o 5009M:f. NAIL WEU& G"O.LQ U&GS)12" FIELD WRLL 5H 5ATN ! N Aly - Fw = MW W24 TYP. TOP R- 6Pl. IGF U. M.0. Tm = , 5x. 15/x 1064' _ 7q9* GOWNS W5 LA P V13L TOP fE 46") MAIL -I(W &F'174* Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 0 M u = 106, 5&/,.) =49"=:> TCr .�--- 0;< GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 10, — 2-2 OAFCT)ON nl ANO nz - FH' 102-0: Fwn2 12x Iq' r n 12x Al �— PI r I� 53c> V 51 � 530' w7q: -© W& -® W6 -® w6 R- Who Cs 22 W5 : t3L �iD sT�AP w 1 z . �4iTrlcft .W/S�o�c3#c4Tc� ToP MJA Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE '-7 27 38 39 \N74 W& - 51? W, 7/ W5 711* = 133*// (0' TAAAX 01 = I ly' 02 = 14' —GF w7u - 8'x(32 -27'x)= 40,' WG = (2-71 '39'y IV= 700# 719'LTfHSION FMF- Ca/. W5 - 3X(133-57"'/) = 225# GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX(209)435-1169 — 1-1 VIRI GCnON 03 FLOOR 501{T INI7 WWA KAT:V 5TUX0-1-FiXOR 2q GC efM119Y-1 TZ)OWF-+6MU - NAIL YY/ 8cl r� (o"OG• � AND 1�" FTW- GF .IW#/, MIN• VVALL 5KATHW& w2L. - Cie) W3L. - Q rYP. TOP R SPLICE WIC - LAP V13L TOP, 9- 48" f NL. WIN 9OW5 or 02). --(Z) G`l8, qx BLOCKINv (5) A35F W2L VOL - X43 r, 32"04. MIN02- IN MJA Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE ._ I 18�w3u 1 i73Z#W4� I�QX375" '" 0 Z 5/7,12, 377,5` i V 377 5# 2W 19.5' r 112.5 W 3L- (28974.377.5 +166g#) 2(111/1 377.5 t7,33 19• E" 6 . TA,A-4 = 25C&01:-1 - 4lo8* 3-7-.5' Cc WIL= 15'xC2b i-12S�), =. ZQ40= W2 = 3'Y (Cg5-q2.5*/,) = 2-7* TOP R5PLI&E GmNE17 GY CHM TENSION ON NVT pAC-,r-- 1--- Wn vz'� x 10" A.B. GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 iZ - 2 - 2 Of R1=( T1 ON 03 - WALL SHF -4 N1)V7 rL - W4. - 11 USP TOP R. 48"' NRI w1 W P011Ys Or -(10)=16d TY P TOP R SPLICf- 05 =285$* 5'2.TW5Lj) I -z4(WGU) 530*(W71J) 3I� 12�x19� I 25.5•x 14 210 150a r29'� G� 1 Wt W 7L w4 V = (2329 +5)2=) _ ��2)OZ = 350*/1 16 -178 14' —G� vV�� = 8xC�78-15a% = 224# W 4 = 3'x (:350-' 150"/,) = 600* Mlll / PFK GF 10-50" 1N Z< ^1L ' T-0 C4AIN SAN' -EL MGERALD MELE & ASSOCIATES '0 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 1 SHEATH I N6 SCHEDULE TYPE DESCRIPTION LP O !i" GYP. BD. w/ 5d COOLERS AT To.c. 100 GYP. BD. w/ Sd COOLERS AT 41104. 125 O �n 1,!iGYP. BD. w/ BLK'G. it 5d COOLERS AT 125 O S�" GYP. BD. w/ BLK'G. d 5d COOLERS AT 150 4"o.c. OQ -%" GYP. BD. w/ BLK'G. s bd COOLERS AT 115 0 4"o.c. O BLK'D. 2-PLY. %" GYP. BD. NAIL BASE PLY. w/ bd COOLERS AT q"o.c. OO NAIL FACE 250 PLY. w/ 8d COOLERS AT 7"o.c. f� EXPANDED METAL, OR WOVEN WIRE LATH O AND Zb" PORTLAND CEMENT PLASTER w/ #11 GA. NAIL, 1!6" LONG, lie" 180 HEAD OR #16 GA. STAPLE, 36" LEGS AT 6"o.c. O fib" TI-11 SIDING w/ 8d GALV. CASING NAILS 156 AT O.C. Oq fib" TI-II SIDING w/ 8d GALV. CASING NAILS 240 AT 4"o.c. 10 tuul 3�'o.cSIDING w/ 8d GALV. CASING NAILS 312 �JI AT IUUI fib" TI-II SIDING w/ 3x STUDS WHERE PANEL II EDGES MEET 8 8d GALV. CASING NAILS AT 408 12 n" APA RATED SHEATHING w/ 8d AT 6"o4. 2(o0 13 APA RATED SHEATHING w/ 8d AT 4"o.c. 380 a" 14" APA RATED SHEATHING w/ 8d AT 3"o.c. 4Q0 IS" APA RATED SHEATHING w/ 3x STUDS WHERE PANEL (540 EDGES MEET d 8d AT 2"o4. I6 Ili" APA RATED SHEATHING w/ 3x STUDS -mo WHERE PANEL EDGES MEET 4 IOd AT 2"o.c. NOTE : REDUCTION FOR ZONES 3 d 4 62 62 ?5 !%S 125 1) NAIL SPACING FOR GYP. BD. AND PLASTER APPLIES TO ALL STUDS, TOP AND BOTTOM FE'S, AND BLOCKING EXCEPT ATTACH LONGITUDINAL EDGES OF LATH AT 2"o.c. 2) NAIL SPACING FOR APA RATED 5HEATHING APPLIES TO ALL EDGES. FIELD NAIL AT 12"6.c. SPACE STUDS AT 16 --oz. USE COMMON NAILS. BLOCK ALL EDGES. 3) -%" GYP. BD. MAY BE SUBSTITUTED FOR !2" GYP. BD. PROVIDED IT IS NAILED W/ bd COOLERS. 14 Hn2A mil Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE WF1 H02A HD2A �tpA .H b6A RMA USA GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435.1169 15 WI 733# 12' G51(o� 12' 1 4.S ml Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS; PE, SE MRu = (12'x 6Pq;-q,75 A15pSF -77x4,75�)O0. P -50y 7.52- H04 = 732x ►i) — 3055 1276 4.5' ►,J5F-C) 051.6 TO L OINE WALL, 1402A TO ONO -P— STI.?125 Q r�OUNDApm WE ssrq�b.�,nt3��l;0 12" )NT WfKKF-T>= FCorlN& PA GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 IG W 2u 8� I 't� 243 W2L. 12 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE ffi'Ru=(gx(nP`,.F-lo.4p x.7,c4'+4',(15PSF)x9z + 4x15PsFz2z4= IIII'� Ha = g3fAO' 4' _&51(o STRAP T0. LOANER WALL. MRL = llll#'' +(14%zx12.P5F+ i2'x6P ) 4._52 +7'x 12 PSFXz'x�5' = 3446.5'�Z' 9 " (g3ex 20't 243-4x 129 - 3446.5'x'' = 4024R' 4.5' —HDGA To Ot3L 2x ANCWR BOLT PEO 24" WO COOSTE FWnN& .A 4- 4-1. 33'r 7n )5►7SFx4' = 1400#-' 14 o 3 —0) G520 TO Loylit?Z WALL NIRS = 7q7#+(I2x6VS +9, 5'x12P5F)X Z t 3'X9.sx12G5FX3' = 2�o6 -I HDL = (316"x24't239 x 12') - 2000 = 2597 3 —402A TO POL 2, W/56TI316 A-0, "00Eo 12" [M-0 Cm,%T-E Fcv7JNG' GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 .17 2564F W74 112' 8 I > tt68� W -h- !2' I I 8" 1042* --� I' i w6 2 7 , 1042'r ix MJA Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE /V1Ru = ( 12'7(6 P5 - 10.4PSFx.��S'+5'x15P5F) t 1,5'X5x 15FSFx$' = g439 � ftnu = 2/3 1 256*x 12') 8 H O u = 213 (2 56'X I2') - `/3X'443q *-' B —NO HC.W N RE:0UiVEP MRL = 44343"-1►�12'x4P.5Ftl'xlZP.cf)i±+1x') FxI.5;K z 7271-► VL = 7,/3(2,56"'�c2'I'+116$#x11' -7271#� _ 761" S — H 0 2A TO 00L 2s NNI 551[316 A. t3. ir�D W' I1r0 CONOKE:� WrING Mru = 01'x(a75/7 - 10.4P=Fx"1A4,.5t4.51xI5pSF) 7'' z Rou : 21X(►o92 xIZ')- 4G 31�t-r = 724# 5 —W CS �0 TO LOWfr--9. '141AI. ) 402A TO NL 2x W/55T13-I( A-0. EMIEPW 12'' INTO cVNc9E1->: FOOTIN& _ GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 m 265 , _ _ MR u :--- WA l%F - i0.4x.7r 11.5'+ 11.5,K15P�F) 31 t8�4X6P�-fx3' � = IIg2�"i W5 I N Ou = 3'3 f lbs x e "? - 11u2-1 _ 6g # 3' 3 (1) G5 20 TO 2,%,12- L KLOVy 01 > 1051 Mr.. _ (►2'x6✓�- fi 1 x1M7F) 3Z t 4'x I2-?-5F-x0(3' 4 I i i 1L I �FI?L = 2/ (,10510X 12') - 522#"' j 3 = 2600- RV5A TO OOL_ 2z. W/ 55T02D A•6 �MFEDU !6" INTO CdWEfE WPM& GERALD MELE & ASSOCIATESN m '0 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 .(209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 1 q LOUNDATION DE51(% wF 1 M14 = 1.3 x(1051#X11') — ; x(522'+"(+154GGfic2�x1K Z� 13.5'�`'� z VN = 1_3 im A. 5 K 1051* CACLDFE L>;NGT7} Iz' 1-051#x12' _3/3(5220'"' rLZ xIwev-,z'X2') 3' 443 UsE �2'WIDE X 2'T-ftK WALL– FOOT)MG W (2) -*4 TOP,}NP WTTVAA TYP, PTI✓MP roPN& s'-0" ptYay. . P/M L A M 24 GERALD MELE & ASSOCIATESN 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE 2� CONCRETE FLEXURE STRENGTH DESIGN -By GMA Consulting Enginee 10/17/97 Comment: 97162 HANSEN RESIDENCE 10:11 AM MATERIAL Properties (KSI) Fy =60 f =2.5 Pb LIMIT 0.375 Properties (INCHES) b = 24.00 t = 24.00 COMPRESSION Steel TENSION Steel Cover = 3.00 Cover = 3.00 TRIAL Re -Bar SIZE 5 TRIAL Re -Bar SIZE # 5 d' -Trial = 3.31 d -Trial = 20.69 REQUIRED Strength w/ LOAD FACTORS (KIPS, KIP FT) Vu =4.5 Mu = 13.5 CALCULATIONS p -required = 0.0003 pb = 0.0178 .75pb =0.0134 Ku -required = 18 B1 = 0.85 % of pb =0.0164614 As -minimum = 1.655 As -required = 0.146 As COMPRESSION required = 0 FINAL OUTPUT (phi = .9 for BENDING, .85 for SHEAR) COMPRESSION Steel TENSION Steel Re -bar SIZE = 4 Re -bar SIZE = 4 USE (2)#4 TOP ANO Comm # of BARS = 1.000 # of BARS = 1.000 MW. �-TF_EL; d' = 3.25 d = 20.75 COE5 mm Amy) As2 = 0.196 As1 = 0.196 As max =6.6546 phi*Mn = 18.23 KIP FT phi*Vc =42.33 KIPS Mu = 13.50 KIP FT Vu = 4.50 KIPS 21 CONNECTIONS u BEAM TO WALL KEN ConsuRing F11 SPLICE ® RIDGE W TO TOP R. eollolm IF 04xa 15 SPECIFIED OF 4x RAFTER TES Use RAFTER \ SPLIGI: RAFTERS O/ RIDGE W/ STRAP SPECIFIED RIDGe ex SHT'G. ALONG RAFTER EX SWO. ALAVG THIS LIPS GON OT RAFTER OR BLOCK TO WALL W/ STRAP 5MCIFIE0 RAFTER*OR BLOCK CONXECT T11115 DLO TO TOP !e. W/ f & TYPE OF A ANCFiOR5 SPECIFIED ' ' ' ' ' ' ' ' iF 04x' i5 5PECIFIED IT D RAFTER f BLOCK TO WALL 40z 59LCX b 4x R iAFTER / DLOCK GERALD MELE & ASSOCIATES . 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 22 F41 BLOCK & STRAP 5TRAP SmIrleo eA SHT'G ALONG THIS LINe 2x4 FLAT BLOCK RAFTeg/JOIST ex ALONG JOIST �J015T Til ATTACH JOIST TO TOP R. W/ ADDITIONAL W TYPe ANCHORS uktnRq Ns SmCIrIeD fw Til NAIL W/ • OF 16d SmolINIED / MIK SPACING V O.C. EA site OP WEA ❑Q JOIST TO WALL ri-N" USe 2 x FLAT BLOCK SEB D L 51 FOR & TYPE Or G5 COIL fa.Jlf R NAILS STRAP SPeCIr1ED RtQb IN Lf1GTH L 0 BLOCK & STRAP IN WALL mix Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE BeAM / .JOIST W/ GDGt NAILING 05 COIL 5TW vL . W/ a AT b O� ALONG ITS LENGTH ED« NAIL 5HCATHING TO BLOCK GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO. CA 93720 (209) 435-1411 FAX (209) 435-1169 23 cEx A-54 AT 24'O,C. ex 5HT'G. Coniutttnq Eng In -are -OR-� Q NP. EXTERIOR WALL @ ROOF AtP4 AT 24b,C. WW=M TOP 55PPLIce W 5PEcb G. 5T6224 NON-BEARING WALL t bd AT 12'OrG. Ex 5H1'G. 5PEcb. ❑Q TYP. INTERIOR SHEAR WALL Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE BEARING WALL GENERAL NOTES 1_ WE- PLANS FOR 5PECIFICATION AND LOCATION OP 5TRAP5. 2 ALL NAILS 5PECIFIED ARE "ca, IONS'. 5. UNLE55 5PECIFICALLY SHOWN OTHEMI F. FASTEN WOOD CONFECTION HARDWARE IN ACCORDANCE WITH MANUFACTUREVS 5PEGIFICATION5. U5E N kt5elt AND TYPE- OF YPEOF FA5TUE-95 5PECIFIED IN LATEST EDITION OF MANJFACTUt&5 CATALOG. 4• ALL WOOD GONNeCTION HARDWARE 15 BY 05I P5ON" TYPICAL UNLE55 NOTED. GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 FRESNO. CA 93720 (209) 435.1411 FAX (209) 435.1169 .2-t eXTE! D LENGTH OF STRAP IF MORE THAN ONE BLOCK .15 REQb. TO ACCOMIODATe ADDITIONAL 'A' ANCHOR5 pEa 199M Consulting Enginssrs El COIL STRAP -APPLICATIONS TJI BLOCK OR RIMJ015T IM -1 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 05 COIL 5M TABLE. FOR # OF NAILS IN LENGTH t' 4X BLACK - AT SPLICE 16d . AT ex 5PAGING OF LFIft • FLOOR WALL SHEATHING WHEN AT 5FEARWALL - OTHE WI5e 690.0. - -10d AT eK QrZM oP LOW!9 FLOCK Wal. 5HE ATHW Wren AT 5W-49Wa.L - 01MESWI5e 6b,C 'Til FLOOR JO I ST ex Consulting Enaln.«s OR 05 COIL STRAP W/ NAIL AT 680.0. ALONG ITS LENGTH TERMINATE STRAP A5 5HOWN COIL STRAP L NAILS 0516 14' (14) 6d 0516 110 (11) 6d 0520 (`0 ed 0822 (7) 6d A55 AT 16'O.G. TYF. JOIST -�— WooD 511A WALL S� OR MA t WALL GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 115 A54 BLOCK - TO TOP IL __ ftj m,m AN `-EN. 5HT'O. Rfi ota=42� SpimtI Comuttfnq Engln« 11 TYP. EXTERIOR WALL OR INTERIOR SHEAR WALL H ex = 51-wo. @O—A �_ AVLE HAD TM -055W/ VERTICAL PRAMINO tvE&BERS AT 1 b'O,C. fsi A-4 AT 2470D. Ex 5HEAR _A.c''tfng OR00, WALL 5HT'G. SPECb. Enpin«re END TRUSS ® WALL 517'0. ex Fsl - TRUSS ® BEARING WALL Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE �— 5EE DTL F7 OR D 2x CRIPPLE -5 16d AT bb,C. L_—TFV55 RAI4LItfnq Engin u '4 AT '4O�C. GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO. CA 93720 (209) 435-1411 FAX (209) 435-1169 116 e Li !4 mix Consulting Erigineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE a5 -AM OY M+F-)?> 16d Q 6"O.C. FOR LATERAL LOAD ONLY. ATTA04MENT OF l,F-�FR 0 . ca Piz VES 1 lC ?[- LOAP6 ):: V OTNERS GERALD MELE & ASSOCIATESN 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435.1169 2'7 STRUCTURAL CALCULATIONS FOR Client: Project: Barnhart -Brown & Associates Hansen Residence Lateral Analysis rA' Consulting Engineers GERALD A. MELS, PE, SE MARTIN R. INESS, PE, SE �% i Oroville, CA FESS/0,Vq Co ;�Q�O CD Q �, LU 0 63 LGAf/. IUJI/Jv J'l,9lRPIx- I �OF CsTRUCT�AUF� GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 OF 2-7 ;r DESIGN PARAMETERS GOVERNING CODE ATERIAL5 1994 UNIFORM BUILDING CODE ( UbG ) SEI SMI C ZONE "4" WIND 75 MPH 6A51 G W I ND5PEED, EXP05URE " 8 " CONCRETE REAR — CONVE 5 2.5K51 (2,500 P51) # 3 GRADE 40, # 4 & LARGER GRADE 60 VERT I CAL i;oADs — FN LATJ=1 AL A!NPLY51> ROOFING 3.0 PS; = PL"OrV 2.0 PSS PIAFTER' 2.2 p5F I NSU LAT'I ON P5t= I`A►S�. 3• d pSF PMS USE 15 PSP MIN USt= 6>'sF FOIZ WALLS U6P- 13 P5F - 3.0 FSF(900ANQ = 12 PSF FO K 03 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 K LATE4 LORD GKRATION' UPPER x GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE M�A Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE a,_ I GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 5 — "No P = Ge, Ct %6 I w P "G7x19.96P5=xIxCri� = 9.G9" P5F p = ,72 x. 1¢, 4(o°5rx1 �! C.ur = 10.4 Gy, PsF Fwo1 = 10•�PSF x r(19'x.a�X.B-t{Igi2')x.5 +(7x10.5�)n(,3t-,?��� = 146b� �-I L Fwuz = Ip,4PSF)4 (WAV)x.5+(I4'x-'),c.3 r(14'n11')x,-7] �-1 L Fwp3 = �j.68P5F,cr(19'x)2')x(.St.S)� 1-1 L �1981t Fwo� = ID•4 l'SF x ElZ'�c .? } (7, YxV)x. 5 1 (-7�c 1o.5')x(•3r.-7) � l = 1024*- 2-Z +Z Fw Di 2-2- = 10, 4 9b47 Cil Z'x (o'+ 1)'x 5 "�,(• >3 ] = 1 o S% FW 15 Z-2 9, 6 8 PS'rr 1(24'x 12) �(• a t- (I 3.5 x G') x. 8 ] = 2059 9138# — SEt�'Y11G V. \'/n1 = 0.183A, P-SP.SFX21'AW) + (oP�>^�c(l�+�x G't 12'x(,"t 7. 1 = )OGo# 1/1)2. = 0.1E3x [(15PsFx I�x 12') i- 6P5Fx (12'x6'+ 14'xb�)� _ (032'* Vp3 = a.163xt(IZPsFxlr"x375"t 6Fyrx.(6'x37.5t(o'x24'+4.5'xrZ')�-'_2025'fi 372-1 m4a Consulting Engineers. GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE WINP GOVERNS 13OrH P:R�--GTIONS GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 - 5HEAR WALL PLAN UfffER LEVE -L. 7 W714 3 4 5 �)C522LOWEIZROOF F No C.522 I 7 I - wr UPM ROOF `- 7 I s I ... 3 V- _�_3" 3' 4522 'v i GERALD MELE & ASSOCIATES 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE 7 - SHEAR WALL PLO LOvr--rt I->;vF-1- mix Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 — 1-1 pl�Ec,TION UPPV Lr:v5L 131 — WALL 5tt ATHIN& wI - `N3u - TYP. TOP PLATf- 5PIXI—r- W I - zx OLOC IW, W166 21 1 mil Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE V Wx If � r' 0 �. 32;- .73L ;- 73L '7. s —Tffim.. = 14v5 x Iq S x ► 2' w3u+ _ 7q �, Vo * GF W1 --=4.5'x61#/' = 2754 YV3y =qO TOP �?- OK GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 N -1-1 pIRi✓ nON 102 — 7/16 "APA. MW SWTHN&j . 24/i(o DFXR -1 • NAIL WEU& G" 0.G tq l=A6Ea� I I- " RFJ-0 WRLL 54 5ATH I N! AU - F'y = IBbq TYP. TOP R. ;PL1(,F U. X1.0. TmAA, = , 5;K. 15'X 1864' _ 711* -17 6OWNS W5 LAP V13L TOP R. 40") VAIL— W/(12) -I bc{ 6F I74 CF- Mu M AA Consulting Engineers GERALD A. MELE, PE,, SE MARTIN R. (NESS, PE, SE GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 W — 2-2 gIRL""cr10Pl Cil ANO 02 - Fw ' 102-41"- FW02 = 1057x i -z C 1 PI 1q' V 7 38 WALL bkPfifflft-, qr w& - ® 17 39 W5 -® NN7L tiW& 'V 5)2 _ 3z#! (312-t-5-30)=1112'4791 = 130/i JV 7/ roe GS 2.2 W5 �L ��D SRAP w 1 i T . Arr r 8 ouc TO ToAcH p M'A Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE TAAAx 1)1 = . 5x512!"6 1y' 02 = , 5 x 53o�x 14' 7u = x - �'=ac (-FF Q w �. (� � ) WG = (2�� 39)Y )2' = 700*-719�`iENs1oN For�E Gv✓ W5 = :32033-57=/') = 22$# GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST, SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 - 1-1 MEMO 03 FLOOR 3RW)4IN(7 �'4 "�} Pfi• RATED 5Yt)R D -h �oK 2q GG. efMIT-1 TONWF-+6RWi Y�, NAIL W/ Sc( "0.G• AND )21''FIE?. &F.lBn FA MIN. I`})'<37.5 9 V-A 12' 173?W44 377,5#' v 377.54 2847` I( f WALL 5HMTH NG II W21. W3L - V q2, ell 19.5'r� g2.S�h \`/ 2L- w.3L (2947 377.5 t ( 6644 =2614/1 S-7 7 3 =l'i 19` 6 79, TOP R GFUCE TA -Ax 37 ,5 , - W21 -44W5 L. TOP, f1' 46" N& L F�r of U2)-16 _-(Z) G�iB, qX BLOCK) NL- _ W3� = 3'x f rg5-q2.5$/�) - 277# TOP �SPLIGE ' (�GVI:>ZNEV GY OD TENVON ON NETT?A&r,- W2L - A.6.� 32" O.G. N NM UZ'� x '10" A.B. VOL - �� (� 32'0•G. MIN Or21N GERALD MELE &. ASSDCIATEB� m7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 1'2- — 2- 2 VIRI=CTION 03 — WALL SHFATWW7 Yy7L = vr4. - 11 1 -AP TOP R q8"' NRI w/wpovxs or -(l0 -w TY P TOP R SPLICE W7L. - A. 0.9 48"0.G Ac' 0, 16'j'r. ,';�) YEr< .N�L mitt Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE v = 28 58°' 512'TWjrll)I to GO 530*(W71J) T,I 12'x ly' I 25,.5'X 14 3— V ?-I o 150a G� 15U# W 7L w4 V _ (232q +512=) _ n/' 2)02-= 350=/, 16 17� — TMAX - 2i_, = )667 G� vV")L = fix(►7`3-1500 = 224# GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 SHEATHIN6 SCHEI;)ULE TYPE DESGRI PTI ON (LP Oj 1'!1" GYP. BD. w/ 5d COOLERS AT '1 "o.c. 100 O It," GYP. BD. w/ 5d COOLERS AT 4"o.c. 125 O �n 1,!5" YP. BD. w/ BLK'G. d 5d COOLERS AT 125 O IUUI Ij" GYP. BD. w/ BLK'G. d 5d COOLERS AT 150 4"O.c. OQ %" GYP. BD. w/ BI-K-6. 8 bd COOLERS AT 1'75 0 4"o.c. BLK'D. 2-PLY. %" GYP. BD. ONAIL BASE PLY. w/ bd COOLERS AT 4"o.c. 250 O NAIL FACE PLY. w/ 8d COOLERS AT -7110.C. EXPANDED METAL, OR WOVEN WIRE LATH O AND Tb" PORTLAND CEMENT PLASTER W #II GA. NAIL, ISi" LONG, -;fb" HEAD OR 180 #I6 GA. STAPLE, 76" LEGS AT 61104. O %" TI II SIDING w/ 8d GALV. CASING NAILS 156 AT 6'. O.C. O %" TI-II SIDING w/ 8d GALV. CASING NAILS 240 AT 4"o.c. 10 Lu 96" TI-111 SIDING w/ 8d GALV. CASING NAILS 312 II luul V' TI-11 SIDING w/ 3x STUDS WHERE PANEL EDGE-5 MEET 4 8d GALV. CASING NAILS AT 408 2"o.c. 12 on fib" APA RATED SHEATHING w/ 8d AT (0"04. 260 13 fib" APA RATED SHEATHING W/ 8d AT 4004. 380 a 14 fib" APA RATED SHEATHING w/ 8d AT 30ot. 440 IS luul W APA RATED SHEATHING w/ 3x STUDS 640 WHERE PANEL EDGES MEET 4 8d AT 2"04. I6 Itt" APA RATED SHEATHING w/ 3x STUDS Ti0 INHERE PANEL EDGES MEET 4 IOd AT 2"o.c. MOTE : REDUCTION FOR ZONES 3 it 4 62 (72 l5 !%S 125 1) NAIL SPACING FOR GYP. BD. AND PLASTER APPLIES TO ALL STUDS, TOP AND BOTTOM T- S, AND BLOCKING EXCEPT ATTACH LONGITUDINAL EDGES OF LATH AT 2"04. 2) NAIL 5PACIN6 FOR APA RATED 5HEATHING APPLIES TO ALL EDGES. FIELD NAIL AT 12"0*.c. SPACE STUDS AT Ib"o.c. USE COMMON NAILS. BLOCK ALL EDGES. 3) V GYP. BD. MAY BE 5U55TITUTED FOR I,�" GYP. BD. PROVIDED IT 15 NAILED W/ bd COOLER5. 1' W02A mix Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE WF1 902A 402A }JVIA H n6A rp ;; K5q GERALD MELE &. ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 15 ov�RTURNING w( 733# MRu= (iZ'x6p�f;-q,75Xt5p-:�x4,7Sx104F�)�7.52 2- 12' 12' - m O4 = ; 733x. �� - 3o,55 _ 12-)- 12`76 733 F-- 5 I G51(o 4.5' G51(o� U5F-C) C51.6 TO LOWER WALL-, 12' 002A _ TO ON13>-r-- %05 Q F-OUN047?04 115E 651-016 PM13EJ1:0 12 INTO CONGKET>= 14,51 Fcottrov GERALD MELE & ASSOCIATESN m7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE 1 > 93 2# W2u S" I 4' 2'4 3* W2L. 12" rA.9 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE nGPSF-10.4P5Fx.7,(4'f 4'X 15Y5F) + Ha = 93eAt3' - 1111#' - I5b64 4' — &51& STRAP TV LWYF-R WALL MRL = 1111#-' +�14%2xIZP5F+ ►Z'x6PSF)sZ +7'xt2P5F-X2'x4,5'=3446.51'Zl NoL = (g32*ic 20't 243#x 12') - 349,6*-' :4024# 4.5' - -1+D6A TO 06L 2x W/&cMIO ANC4N OUT p50 24" iNTIO COOSTE IFOOMN& /V1qu :,(12" 6:5r - 10,+CSI x.7xq.5 +9 5x3P5F)x4'- +• I, 33'r 7n 15PSFX4' = 1400 -� 14 OU = 31e;K I2' - 1460 4 _ 7q74 3 —6) (-20 TO LrjW'Q? WALL MRL = 797#+(12'x6-5F+9,6'X12 -*)X-Z +' 3'x 9. 5'9 12PSFx 3' = 264#-► HvL = C316"x24't239 x!2') -2660#'f = 2597 3 —402A TO POL 2x. W/S6T616 A-0. 5MLEOEP 12" IM COrMTE FOCTIN6 GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 17 25 G4F ANRu = C 12'x6t'SF - IQ,4G5Fx.7x,5'.`.�'x15PSr) �1. W..?y� + 1.5'X5'x 15 P5 I !z" "L7U = ?/3 ; 256*x 12') S W7- t2' N 0 = 213 1(25 -"X12�� - `�3X443y l 1 8 S —N0 Hc"W" :1?rQU!9e MqL = 443q*1-tt�12'x4f6Frl'x�+I' V1 Fx1.5x8' z 7271-� NGL = 2/3(256�"�c24t1168#xl1'� -7271#y _ 769# 8 —H02A To DLL 2.x NNI 50316 A.S. ESD W' 1 Nr0 CONOKE FOOMC, 1042'��----� MRU = 02.'x6�sr- - 10,4P=Fx�n4,5't4.5�xI5P5F� 72 r q'x12'x(oFSFA7' = 4631 `' 2- 12 , ►+vu 724 7 , F-1042" ,5 -t —(1) CS 2O To LowF-R !NAL—L) 402A Y0 DOL U w/65V-1& A.0. EWEPW 12-" )NT -0 cXVEr>: FOOTiN& GERALD MELE & ASSOCIATESN m '0 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435.1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 1 S 20 - Mau = (6'A - 0.4Y.7, 11.5'+ II.5',05P,�F) 32 t Si��x6iKFx3' - Iig2�"1 W5 I v I lbs z Q "? - I IC42�-1 _ 6q # 3' 3 (1) C6 20 To /--n 1 i 13 FLOVY > 1051-1p/v1r.� _ (12'X6 ter- fi 1 xlMf) _Z t 4'Xlz� x1'x3, I i W4 I 1L� N Dl. _ 2/3 (105/ox 12-') - 522'`x"' � = 2000 3 3 R05A TO GO L Wiz. W/ 6GT9 20 X6. EJY+ EPE—D'16" INTO CVWF-rE fOfMM& GERALD MELE & ASSOCIATES M 0 7337 N. FIRST ST. SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE Iq FOUNDATION D�51GN SNF 1 My = 1,3 x(1051#X If) x (522f*-' + W PCfx7 x2x V4 = 13_6 K'I 4_5 1< 3 CAV LEVEQ LV--N6TI+ f051#' 1z' 1051 #x12' - 3/,3 (522•#-I rLz XI Wr6f:*z'x 29 i USE .Z'wm�x2/T1+rK WAU- FWOTM& W (2) -*4 TOP AND f3 70AA TYP, pTiiAfr) 1`cpN& s'-0„ l3EYoV . PAKL 1 GERALD MELE & ASSOCIATES\ M 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE7' MARTIN R. (NESS, PE, SE 20 CONCRETE FLEXURE STRENGTH DESIGN - By GMA Consulting Enginee 10/17/97 Comment: 97162 HANSEN RESIDENCE 10:11 AM MATERIAL Properties (KSI) Fy =60 fc =2.5 Pb LIMIT 0.375 Properties (INCHES) b = 24.00 t = 24.00 COMPRESSION Steel TENSION Steel Cover = 3.00 Cover = 3.00 TRIAL Re -Bar SIZE 5 TRIAL Re -Bar SIZE # 5 d' -Trial = 3.31 d -Trial = 20.69 REQUIRED Strength w/ LOAD FACTORS (KIPS, KIP FT) Vu =4.5 Mu = 13.5 CALCULATIONS p -required = 0.0003 pb = 0.0178 .75pb =0.0134 Ku -required = 18 131 = 0.85 % of pb =0.0164614 As -minimum = 1.655 As -required = 0.146 As COMPRESSION required = 0 FINAL OUTPUT (phi = .9 for BENDING, .85 for SHEAR) COMPRESSION Steel TENSION Steel Re -bar SIZE = 4 Re -bar SIZE = 4 U61-(2)44 TOP ANO 130TTON1 # of BARS = 1.000 # of BARS = 1.000 (0M.ri>4/zMt4 : MSN. STEEL; 'F:00 d'= 3.25 d = 20.75 coEs mm Amy) As2 = 0.196 As1 = 0.196 As1max =6.6546 phi*Mn = 18.23 KIP FT phi*Vc =42.33 KIPS Mu = 13.50 KIP FT Vu = 4.50 KIPS 2l CONNECTIONS 0 BEAM TO WALL Consul Ing Q SPLICE ® RIDGE COMECT BEAM TO TOP R. W/ STRAP SPECIFIED ALL IF 'rbc' IS SPEGIFIeo 4DESIGNATES Use OF x RAFTER RAFTER 5PL.ICe RAFTERS 0/ RIDGE W/ STRAP SPECIFIED Mcrae ex SHT'G. ALONG RAFTER Ex SWO. ALONG THIS LITE COTNECT RAFTER OR BLOCK TO WALL W/ STRAP SPECIFIED RAFTER *OR BLOCK CONFECT THIS 5L.Oqr* TO TOP IC W/# 6 TYPE OF A ANC41OR5 SPECIFIED IF 14x' 15 SPECIFIED IT 0 RAFTER f BLOCK TO WALL 4°5e'Lx. 45x R (AFTER / E51LOCK GERALD MELE & ASSOCIATES m 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE 22 i 5TRAP SPGCIrIED Ex SHT'G ALONG THI5 LIM 2x4 FLAT 15L..00K RAFTER/JOIST Q BLOCK & STRAP eX ALONG J015T 15T - TJI-171 ATTACH JOIST TO TOP IL W/ ADDITIONAL 'A' TYPL' ANCHOR'' ,"MingF 90mi mwrOR TJI NAIL W/ # OF 16d SPECIrIED / MIN. SPACING V O.G. EX SICe Or WISH El JOIST TO WALL WALL STUC0 ` ME 2x FLAT DL..00K SW D FOR S 8 -TYPE Or 05 COIL NLlA�R Or NAILS STRAP SPCGIrIED Rlrob IN LENGTH L Q BLOCK & STRAP IN WALL . M49 Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE MAM / JOIST W/ COW NAILING 05 COIL STRAP NAIL . W/ 8 AT 6 OAC, ALONG ITS L eNGTH EC*e NAIL SHCATHING TO FLOCK GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO. CA 93720 (209) 435-1411 FAX (209) 435-1169 23 Ex EK 1 bd AT I tO.C. A54 AT 24`OJC. 9 �k� MA AE�l t x Swo.Cannufttnq Engin«nPEGb. 5PEGb. OR 0 TYP. EXTERIOR WALL ® ROOF Ex A'P4 AT 24`0,0. W IM TOP SPLICE W 5PE0b. G 5T6224 Consu4Engn NON-BEARING WALL BEARING WALL Q TYP. INTERIOR SHEAR WALL rAA Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE GENERAL NOTES I. 5EE PLAN5 FOR 5PECIFICATION AND LOCATION OF 5TRAP5. Z ALL. NAILS SPECIFIED ARE 'COMMONV. 3. LH -E55 5PECIFICALLY SHOWN OTHE W15e. FA51EN WOOD COME -CTM MRDWARE IN ACCORDANCE WITH MAN FACTUREW5 SPEGIFICATION5. Use mlpe-R AND TYPE OF FA5TeM95 5PECIF1eD IN L ATe5T EDITION OF MAm1FA0TLJRE:W5 CATALOG. 4. ALL WOOD GONCOTION HARDWARE 15 15Y '51IvPW TYPICAL MZ -55 NOTED, GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO. CA 93720 (209) 435-1411 FAX (209) 435.1169 It EXTeND LENGTH of STRAP IF MORD THAN ONE U.00K 15 RE -41D. TO ACC AVQATE ADDITIONAL ANCHORS Ism w is Con.ulUnO En9f rs 0 COIL STRAP -APPLICATIONS EN. TJI BLOGIC� OR RIMJOIST Im Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. (NESS, PE, SE G5 GOIL SW TADLE. POR f OP NAILS IN LENGTH L' 4X BLOCK - AT SPLICE 16d.AT EA 5PAGING OF � Ulft • FLOOR WALL SHEATHING WHEN AT 5HeARWALL – O1?F:AWI5E 6'O.G. - 3►1 -10d AT eK-93ZM OF LOWER FLOOR WALL SHEW W -v W1i3l AT -qyARWALL - oriatN15e 6bc. 'T'JI FLOOR JOIST ja E1�L ConsuMng Fm9kwers OR 05 COIL STRAP W/ NAIL AT 600.0. ALONG ITS LFNGTK TERMINATE STRAP AS 5HOWN COIL STRAP L NAILS 0516 14' (14) bd 0516 Ila (11) bd 0520 (`D 6d A55 AT 16'0.0. TYP. JOIST -�— WOOD STIR WALL fMt► � OR WALL GERALD MELE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 115 A54 BLOCK - TO TOP IL mAW \-Ex 5NT`G. 094=AV� sPecb. ConautUnq EngtnN 1I TYP. EXTERIOR WALL OR INTERIOR SHEAR WALL 5i two. @GAIDLE eND TRUW W/ VERT IGAL FRAMING —A 5 AT I eOZ. ex � A54 AT 24'0.0 ex —OR WALL 5M'1,G SPeGb. m a%� ' s Itfnq Enaln m 12 END TRUSS ® WALL I�— SEE DTL n7 OR D 5tiT'G. n Ii i— 2x LAW -r -1-C.7 ex 13 TRUSS ® BEARING WALL mix Consulting Engineers GERALD A. MELE, PE, SE MARTIN R. INESS, PE, SE I 6 AT eOD. -TRU55 MLUng EnglnMrs ,>4 AT 480jC. GERALD MELEE & ASSOCIATES\ 7337 N. FIRST ST., SUITE 110 FRESNO. CA 93720 (209) 435.1411 FAX (209) 435-1169 116 iq 131:'�AM OY 0rRF-)Z9 WO G"O.G. FOR LATERAL LCPF) ONLY. ATTAGNMr-NT OF Lr- i E� 70 OTNE4zS GERALD MELE & ASSOCIATES m '07337 N. FIRST ST., SUITE 110 FRESNO, CA 93720 (209) 435-1411 FAX (209) 435-1169 Consulting Engineers GERALD A. MELE, PE, SE 2 MARTIN R. INESS, PE, SE CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Hansen Residence Date........ 08/21/97 Project Address........ 21 Buehler ******* Oroville, CA 95966 *v4.50* Documentation Author... Donna Wallace ******* Building Permit Wallace Energy Consulting 399.East 9th Avenue Plan Check Date Chico, CA 95926 916-893-4982 Field Check/ Da e Climate Zone. ........ 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence GENERAL INFORMATION Conditioned Floor Area..... .1346 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front.Facing 225 deg (SW) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Raised -Floor Glazing Percentage......... 12.8 % of floor area Average Glazing U -value.... 0.66 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R -value R -value R -value U -value Location/Comments Wall Wood R-11 R-0 R-11 0.098 Utility, Bath/Bedroom Wall Wood R-13 R-0 R-13 0.088 Bath/Fam/LR Stairs/Util/LR BR/Stairs/Off LR/Office Wall Wood R-17.8 R-0 R-17.8 0.065 Dining/Kitchen LR/Kitchen Door n%a R-0 R-n/a R-0 0.330 Dining Roof Wood R-11 R-19 R-30 0.031 Typical FloorExt Wood R-19 R-0 R-19 0.048 Dining/Kitchen FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior. hang/ Framing Orientation (sf) Value es Description Shading Fins Type -Window Front (SW) 24.0 0.940 2 Blinds.Lt None None Wood %Door Front (SW) 40.0 0.940 2 Blinds.Lt None Yes Wood e.Window Front (SW) 16.0 0.410 2 Drapes.Std None Yes Vinyl .Window Left (NW) 16.0 0.330 2 Blinds.Lt None None Wood -Window Back (NE) 18.0 0.940 2 Blinds.Lt None None Wood -Window Back (NE) 10.7 0.480 2 Blinds.Lt None None Wood -Window Right (SE) 10.7 0.480 2 Blinds.Lt None Yes Wood -Window Right (SE) 10.7 0.330 2 Blinds.Lt None Yes Wood Window Right (SE) 16.0 0.410 2 Drapes.Std None None Vinyl -Window Right (SE) 10.7 0.480 2 Blinds.Lt None None Wood CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence HVAC SYSTEMS The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.780 AFUE Attic R-4.2 Setback ACPackage 8.90 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Storage Gas PointOfUse 2 0.62 EF 30 R-12 SPECIAL FEATURES/REMARKS The original building was built in 1984. SF = 22 x 40 + 3 x 8 + 3 x 8 + 3 x 12.5 + 19 x 12 + 14 x 12 - 4 x 4 = 1346 sf The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run-Hansen.Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations tc implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Lloyd & Maxine Hansen Name.... Company. Company. Address. 21 Buehler Address. Oroville, CA 95966 Phone... (916) 533-4913 Phone... License. DOCUMENTATION AUTHOR Donna Wallace Wallace Energy Consulting 399 East 9th Avenue Chico, CA 95926 916-893-4982 Signed..664V - S'- Signed.. l/�� S/2-l�g7 (date) (date ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. ate MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterick (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures *150(a): Minimum R-19 ceiling insulation. R-30 150(b): Loose fill insulation manufacturer's labeled R -value. N/A *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal R-11, 13 8 19 framed walls (does not apply to exterior mass walls). R-19 150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. N/A 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. Fiberglass 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. Batts 116-17: Fenestration Products, Exterior Doors and Infilitration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products have label with certified U -value and By Owner infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. N/A 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. N/A 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closable metal or glass door b. Outside air intake with damper and control N/A c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. By Owner 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. Attached 150(1): Setback thermostat on all applicable heating and/or cooling systems. By Owner 150(j): Pipe and Tank Insulation 1. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. By Owner 3. All buried or exposed piping insulated in recirculating sections of hot water systems. 4. Cooling system piping below 55 degrees Fahrenheit insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC Sections 601 and 603; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. By Owner 2. Exhaust fan systems have backdraft or automatic dampers 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: N/A a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical By Owner cooking appliances with pilot < 150 Btu/hr.) Lighting Measures 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water By Owner closets; and recessed ceiling fixtures IC (insulation cover) approved. Residential Compliance Form March 1, 1996 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 ******* Project Address........ 21 Buehler Oroville, CA 95966 *v4.50* Documentation Author... Donna Wallace ******* Building Permit Wallace Energy Consulting 399 East 9th Avenue Plan Check Da e Chico, CA 95926 916-893-4982 Field Check/ Da e Climate Zone.. ..... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 11.78 12.00 -0.22 Space Cooling.......... 16.30 15.51 0.79 Water Heating.......... 15.25 13.74 1.51 Total 43.33 41.25 2.08 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1346 sf Single Family New Front Facing 1 1 ReducedYear Raised Floor 1 10768 cf 380 sf 0 sf 0 sf Detached 225 deg (SW) 12.8 % of floor area 0.66 Btu/hr-sf-F 8 ft COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 1346 10768 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 52 0.098 11 225 90 Yes W.11.2X4.16 Utility 2 Wall 204 0.088 13 225 90 Yes W.13.2X4.16 Bath/Fam/LR 3 Wall 116 0.065 17.8 225 90 Yes W.19.2X6.16 Dining/Kitchen 4 Door 20 0.330 0 225 90 Yes None Dining 5 Wall 160 0.098 11 315 90 Yes W.11.2X4.16 Bath/Bedroom 6 Wall 72 0.088 13 315 90 Yes W.13.2X4.16 Stairs/Util/LR 7 Wall 92 0.065 17.8 315 90 Yes W.19.2X6.16 Dining/Kitchen 8 Wall 190 0.088 13 45 90 Yes W.13.2X4.16 BR/Stairs/Off 9 Wall 253 0.065 17.8 45 90 Yes W.19.2X6.16 LR/Kitchen 10 Wall 24 0.098 11 135 90 Yes W.11.2X4.16 Utility 11 Wall 103 0.088 13 135 90 Yes W.13.2X4.16 LR/Office 12 Wall 165 0.065 17.8 135 90 Yes W.19.2X6.16 Dining/Kitchen 13 Roof 1346 0.031 30 n/a 0 Yes R.30.2X4.24 Typical 14 F1oorExt 380 0.048 19 n/a 0 No FX.19.2X8.16 Dining/Kitchen FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 12.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 2 Door 40.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 3 Window 12.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 4 Window 16.0 2 Vinyl Slider 0.410 225 90 0.88 0.78 Drapes.Std 5 Window 8.0 2 Wood Hinged 0.330 315 90 0.50 0.58 Blinds.Lt 6 Window 8.0 2 Wood Hinged 0.330 315 90 0.50 0.58 Blinds.Lt 7 Window 9.0 2 Wood Slider 0.940 45 90 0.88 0.58 Blinds.Lt 8 Window 9.0 2 Wood Slider 0.940 45 90 0.88 0.58 Blinds.Lt 9 Window 10.7 2 Wood Slider 0.480 45 90 0.88 0.58 Blinds.Lt 10 Window 10.7 2 Wood Slider 0.480 135 90 0.88 0.58 Blinds.Lt 11 Window 10.7 2 Wood Slider 0.330 135 90 0.50 0.58 Blinds.Lt 12 Window 16.0 2 Vinyl Slider 0.410 135 90 0.88 0.78 Drapes.Std 13 Window 10.7 2 Wood Slider 0.480 135 90 0.88 0.58 Blinds.Lt COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 2 Door 40.0 6.7 n/a 3.0 0.3 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 16.0 4.0 4.0 5.5 0.3 7.0 3.0 n/a n/a n/a n/a n/a n/a 10 Window 10.7 4.0 2.7 14.0 1.3 2.0 12.8 n/a n/a n/a n/a n/a n/a 11 Window 10.7 4.0 2.7 14.0 1.3 5.3 9.5 n/a n/a n/a n/a n/a n/a HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE Furnace 0.780 AFUE Attic R-4.2 0.830 ACPackage 8.90 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas PointOfUse 2 0.62 30 R-12 SPECIAL FEATURES/REMARKS The original building was built in 1984. SF = 22 x 40 + 3 x 8 + 3 x 8 + 3 x 12.5 + 19 x 12 + 14 x 12 - 4 x 4 = 1346 sf The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence SPECIAL FEATURES/REMARKS Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. HVAC SIZING Page 1 HVAC Project Title.......... Hansen Residence Date........ 08/21/97 ******* Project Address........ 21 Buehler Oroville, CA 95966 *v4.50* Documentation Author... Donna Wallace ******* Building Permit Wallace Energy Consulting 399 East 9th Avenue Plan Check Date Chico, CA 95926 916-893-4982 Field Check/ Da e Climate Zone.. ..... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -HVAC SIZING User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 1346 sf 10768 cf Front Facing OROVILLE RS 39.5 degrees 30 F 70 F 104 F 78 F 37 F No No Yes 0.20 HEATING AND COOLING LOAD SUMMARY Sensible Load .................... 19725 LatentLoad ...................... n/a 225 deg (SW) Cooling (Btuh) 5134 2975 4513 2515 2100 1724 18961 3792 Minimum Total Load 19725 22754 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Description (Btuh) Opaque Conduction and Solar...... 7230 Glazing Conduction ............... 4577 GlazingSolar .................... n/a Infiltration ..................... 6125 InternalGain .................... n/a Ducts.... ......................... 1793 Sensible Load .................... 19725 LatentLoad ...................... n/a 225 deg (SW) Cooling (Btuh) 5134 2975 4513 2515 2100 1724 18961 3792 Minimum Total Load 19725 22754 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. e 0 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Project Address........ Documentation Author... Climate Zone.... ..... Compliance Method...... Hansen Residence 21 Buehler Oroville, CA 95966 Donna Wallace Wallace Energy Consulting 399 East 9th Avenue Chico, CA 95926 916-893-4982 11 MICROPAS4 v4.50 for 1995 ******* *v4.50* ******* Page 1 CF -1R Date........ 08/21/97 Building Permit Plan Check Da e Fie Check/ Da e Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... Glazing Percentage......... Average Glazing U -value.... 1346 sf Single Family Detached New Front Facing 225 deg (SW) 1 1 Raised Floor 12.8 % of floor area 0.66 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R -value R -value R -value U -value Location/Comments Wall Wood R-11 R-0 R-11 0.098 Utility, Bath/Bedroom Wall Wood R-13 R-0 R-13 0.088 Bath/Fam/LR Stairs/Util/LR BR/Stairs/Off LR/Office Wall Wood R-17.8 R-0 R-17.8 0.065 Dining/Kitchen LR/Kitchen Door n/a R-0 R-n/a R-0 0.330 Dining Roof Wood R-11 R-19 R-30 0.031 Typical FloorExt Wood R-19 R-0 R-19 0.048 Dining/Kitchen FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (SW) 24.0 0.940 2 Blinds.Lt None None Wood Door Front (SW) 40.0 0.940 2 Blinds.Lt None Yes Wood Window Front (SW) 16.0 0.410 2 Drapes.Std None Yes Vinyl Window Left (NW) 16.0 0.330 2 Blinds.Lt None None Wood Window Back (NE) 18.0 0.940 2 Blinds.Lt None None Wood Window Back (NE) 10.7 0.480 2 Blinds.Lt None None Wood Window Right (SE) 10.7 0.480 2 Blinds.Lt None Yes Wood Window Right (SE) 10.7 0.330 2 Blinds.Lt None Yes Wood Window Right (SE) 16.0 0.410 2 Drapes.Std None None Vinyl Window Right (SE) 10.7 0.480 2 Blinds.Lt None None Wood a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence I: 0:4 'UR, The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.780 AFUE Attic R-4.2 Setback ACPackage 8.90 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Storage Gas PointOfUse 2 0.62 EF 30 R-12 SPECIAL FEATURES/REMARKS The original building was built in 1984. SF = 22 x 40 + 3 x 8 + 3 x 8 + 3 x 12.5 + 19 x 12 + 14 x 12 - 4 x 4 = 1346 sf The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Lloyd & Maxine Hansen Name.... Company. Company. Address. 21 Buehler Address. Oroville, CA 95966 Phone... (916) 533-4913 Phone... License. DOCUMENTATION AUTHOR Donna Wallace Wallace Energy Consulting 399 East 9th Avenue Chico, CA 95926 916-893-4982 Signed..."�� .. � �signed.. it (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. ate MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterick (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures *150(a): Minimum R-19 ceiling insulation. R-30 150(b): Loose fill insulation manufacturer's labeled R -value. N/A *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal R-11, 13 & 19 framed walls (does not apply to exterior mass walls). R-19 150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. N/A 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. Fiberglass 118: insulation specified or installed meets insulation quality standards. Indicate type and form. Batts 116-17: Fenestration Products, Exterior Doors and Infilitration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products have label with certified U -value and By Owner infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. N/A 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. N/A 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closable metal or glass door b. Outside air intake with damper and control N/A c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. By Owner 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. Attached 150(1): Setback thermostat on all applicable heating and/or cooling systems. By Owner 150(j): Pipe and Tank Insulation 1. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. By Owner 3. All buried or exposed piping insulated in recirculating sections of hot water systems. 4., Cooling system piping below 55 degrees Fahrenheit insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC Sections 601 and 603; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. By Owner 2. Exhaust fan systems have backdraft or automatic dampers 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: N/A a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical By Owner cooking appliances with pilot < 150 Btu/hr.) Lighting Measures 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water By Owner closets; and recessed ceiling fixtures IC (insulation cover) approved. Residential Compliance Form March 1, 1996 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 ******* Project Address........ 21 Buehler Oroville, CA 95966 *v4.50* Documentation Author... Donna Wallace ******* Building Permit Wallace Energy Consulting 399 East 9th Avenue Plan Check Date Chico, CA 95926 916-893-4982 Field Check/ Da e Climate Zone.... ..... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 11.78 12.00 -0.22 Space Cooling.......... 16.30 15.51 0.79 Water Heating.......... 15.25 13.74 1.51 Total 43.33 41.25 2.08 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1346 sf Single Family New Front Facing 1 1 ReducedYear Raised Floor 1 10768 cf 380 sf 0 sf 0 sf Detached 225 deg (SW) 12.8 % of floor area 0.66 Btu/hr-sf-F 8 ft COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 1346 10768 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 52 0.098 11 225 90 Yes W.11.2X4.16 Utility 2 Wall 204 0.088 13 225 90 Yes W.13.2X4.16 Bath/Fam/LR 3 Wall 116 0.065 17.8 225 90 Yes W.19.2X6.16 Dining/Kitchen 4 Door 20 0.330 0 225 90 Yes None Dining 5 Wall 160 0.098 11 315 90 Yes W.11.2X4.16 Bath/Bedroom 6 Wall 72 0.088 13 315 90 Yes W.13.2X4.16 Stairs/Util/LR 7 Wall 92 0.065 17.8 315 90 Yes W.19.2X6.16 Dining/Kitchen 8 Wall 190 0.088 13 45 90 Yes W.13.2X4.16 BR/Stairs/Off 9 Wall 253 0.065 17.8 45 90 Yes W.19.2X6.16 LR/Kitchen 10 Wall 24 0.098 11 135 90 Yes W.11.2X4.16 Utility 11 Wall 103 0.088 13 135 90 Yes W.13.2X4.16 LR/Office 12 Wall 165 0.065 17.8 135 90 Yes W.19.2X6.16 Dining/Kitchen 13 Roof 1346 0.031 30 n/a 0 Yes R.30.2X4.24 Typical 14 FloorExt ,380 0.048 19 n/a 0 No FX.19.2X8.16 Dining/Kitchen FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 12.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 2 Door 40.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 3 Window 12.0 2 Wood Slider 0.940 225 90 0.88 0.58 Blinds.Lt 4 Window 16.0 2 Vinyl Slider 0.410 225 90 0.88 0.78 Drapes.Std 5 Window 8.0 2 Wood Hinged 0.330 315 90 0.50 0.58 Blinds.Lt 6 Window 8.0 2 Wood Hinged 0.330 315 90 0.50 0.58 Blinds.Lt 7 Window 9.0 2 Wood Slider 0.940 45 90 0.88 0.58 Blinds.Lt 8 Window 9.0 2 Wood Slider 0.940 45 90 0.88 0.58 Blinds.Lt 9 Window 10.7 2 Wood Slider 0.480 45 90 0.88 0.58 Blinds.Lt 10 Window 10.7 2 Wood Slider 0.480 135 90 0.88 0.58 Blinds.Lt 11 Window 10.7 2 Wood Slider 0.330 135 90 0.50 0.58 Blinds.Lt 12 Window 16.0 2 Vinyl Slider 0.410 135 90 0.88 0.78 Drapes.Std 13 Window 10.7 2 Wood Slider 0.480 135 90 0.88 0.58 Blinds.Lt COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run-Hansen'Residence Surface HOUSE 2 Door 4 Window 10 Window 11 Window OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 40.0 6.7 n/a 3.0 0.3 n/a n/a n/a n/a n/a n/a n/a n/a 16.0 4.0 4.0 5.5 0.3 7.0 3.0 n/a n/a n/a n/a n/a n/a 10.7 4.0 2.7 14.0 1.3 2.0 12.8 n/a n/a n/a n/a n/a n/a 10.7 4.0 2.7 14.0 1.3 5.3 9.5 n/a n/a n/a n/a n/a n/a System Type HOUSE Furnace ACPackage HVAC SYSTEMS Minimum Duct Duct Duct Efficiency Location R -value Efficiency 0.780 AFUE Attic 8.90 SEER Attic WATER HEATING SYSTEMS R-4.2 0.830 R-4.2 0.810 The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas PointOfUse 2 0.62 30 R-12 SPECIAL FEATURES/REMARKS The original building was built in 1984. SF =, 22 x 40 + 3 x 8 + 3 x 8 + 3 x 12.5 + 19 x 12 + 14 x 12 - 4 x 4 = 1346 sf The package gas heat/electric cool HVAC unit was installed in approximately 1990. As part of this project, two new 30 gallon gas storage water heaters will be installed. These water heaters must be certified to the California Energy Commission. The Owner has two 2840 Anderson wood windows, purchased in 1995, which will be installed in the Kitchen. These windows have a U -value of 0.48 per the NFRC Directory of Certified Products, Second Edition, January 1994. The Living Room has one 2840 Andersen wood window purchased in 1995. It has a U -value of 0.48 per the NFRC Directory. Two new 2830 windows Andersen wood windows will be installed in the Bedroom and one new 2840 Andersen wood window will be installed in the Living Room. These windows have a maximum U -value of 0.33 and a maximum shading coefficient of 0.50. COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Hansen Residence Date........ 08/21/97 MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence SPECIAL FEATURES/REMARKS Reference: NFRC data provided by Manufacturer. Two new 4040 Viking vinyl windows with low -E glass will be installed in the Dining Room. These windows have a maximum U -value of 0.41. Reference: NFRC Directory, Sixth Edition, November 1996. HVAC SIZING Page 1 HVAC Project Title.......... Hansen Residence Date........ 08/21/97 hl ******* Project Address........ 21 Bue er Oroville, CA 95966 *v4.50* Documentation Author... Donna Wallace ******* Building Permit Wallace Energy Consulting 399 East 9th Avenue Plan Check Da e Chico, CA 95926 916-893-4982 Field Check/ Da e Climate Zone..... ..... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HANSEN4 Wth-CTZ11S92 Program -HVAC SIZING User#-MP0995 User -Wallace Energy Consulting Run -Hansen Residence GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1346 sf 10768 cf Front Facing OROVILLE RS 39.5 degrees 30 F 70 F 104 F 78 F 37 F No No Yes 0.20 HEATING AND COOLING LOAD SUMMARY 225 deg (SW) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 7230 5134 Glazing Conduction ............... 4577 2975 Glazing Solar .................... n/a 4513 Infiltration ..................... 6125 2515 Internal Gain .................... n/a 2100 Ducts ............................ 1793 1724 Sensible Load .................... 19725 18961 Latent Load. ..................... n/a 3792 Minimum Total Load 19725 22754 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Z. Permit Applicant: d- NX' ne +" n Pe* it Number: ! 7-1VV S Assessor ]Parcel Number: 0(0 -2(0-109 Date: The above referenced building . plans were reviewed by this office. Provide additional information and/or make revisions to plans, spec ficadons and calculations as follows: /-Zoo A rn u .n . �c e CXCe ed • Gf..cl,Q1�. fro !3 2.1Z�.o� 5 D ^I- ►Y,,,w►�, -acid, - I on pa jn awt... i 6r1. r>lA L'TL d, 3 Q. v-c,6,,L e ca.Q:c� c ecru- s T.,. _0-na U dJ" a Yup c 1Cf •2 COVI �e on -6-t bract If you wish to discuss any requirements, you may contact me at (916) 538-7541 between 1:00 P.M. and 4.00 P.M., Monday through Thursday. PLAN REVISION- Please complete the following information in order to process your submittal. If this form is not complete, correct and legible, it may cause a delay in processing. Owner's Name: _' ( 5 V CI � � X It hP a u S Q n Received By: Date: A.P. #: 66 'Co') f 0 " / 0 ( Permit # ContactPhoneNumber: Purpose of submittal: ❑ Permit Application Data Item ❑ Engineering ❑ Plan Revision 99-1906— of' 9-1906 ❑ Requested by Building Inspector or Correction Notice - Inspector's Name: 1 Requested By Plan's Examiner - Examiner's Name: `/!" to /�Ci�cSLI .,— V bef s IT %e by[QnS ❑ Other: ) lads J a n 4 . Time: f of rd /V — eapy If you are revising a plan which has already been issued, submit two(2) drawings reflecting the revisions for plan review. If engineering is involved in this revision, the engineer must put his requirements on these drawings and stamp and sign the drawings. Include two (2) sets of wet signed engineering. Revised drawings must clearly show When Approved, Process as Follows: ❑ Mail to Owner at this address: ❑ Mail to Contractor at this address: Call 1 ❑ Deliver with next inspection. and hold for pickup at the ❑ Chico Office /0Oroville Office Revised Plan Check Fee: ❑ $46.00 Receipt #: Additional Fees Not Required Additional fees may be due based upon complexity and time involved to process this submittal. Additional Fees: Receipt #: TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance �- oYD �M 4X,A(F /)4-Aesw E.H. USE ONLY Plot Plan Attached Floor Plan Att had �— Sent to B.D�' w�G Owner /Location AP# Plan Approved for: Sewage Disposal �Water Supply: Public �/ Private Well Clearance for dwelling. Other AZ. �rc i�c-�•� b . ��u �1 PAK,-,e Holdfirrance Final cO. or: NOTE:l Environmental Health Specialist �0 JUL 8 1497 ( COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-754 /�IT No• (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER ZONING A� BUILDING PERMIT OWNER V)qo'LlTELEPHONE SO. FT. OCC. BUILDING VALUATION -e ERS00 AbORE CONTRACTOR'S TELEPHONE TORS MAILING ADDRESS cdm%Avn CONSTRUCTION LENDER ' Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filin Fee 20.00 Permit Fee _ ARCHITECT OR ENGINEERSMAOJNG ADDRESS Plan Checkina Fee BULLDINOADDRESS 1✓1.�--�--• IJ Energy Plan Checking Fee $ _25, 3 U PERMIT FEE _ , LOT NO. SUBDNISIONS NAME PAROEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 41 7.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECK Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK Newt Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other J� Describe Work: ' i�(4 SSZ Z,CL ^"�,p (1 (� a( Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE s9,62 1 ELECTRICAL PERMIT Filing Fee 20.00 oauv OR LESS Main Service 200A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I herebyaffirm under penalty of perjury that I am licensed under provisions of Chapter p •y P J Y 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect License Class Uc. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project.1_2�i-eD ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by "section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation Insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 131 certify that In the performance of the work for which this permit is Issued, I shall not employ any person In any manner so as to become subject to workers'w►z. compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shell forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. Main Service MWA TO 1000A ll 46.00 . V NEW CONST. DWELLING OCCUP. s0 OR AODNS. ( a Arc. BLOB. 3.50T. t! N CONS . MULT40UTLEr 7 CJO NON. RESID.C. POWER APPARATUS 8 SINGLE OUTLET C10. Ex. Occup. OUTLET OR FD=RES :IQ o ':0 APPLNS. OR Ex. Occup. ouTLETs 8610. EA 5.00 MEA Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S MECHANICAL PERMIT Filing Fee 20.00 Heating - Cooling Hood 6.50 jZ7 Ventilation PERMIT FES S Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ t IMP vL000 coF PARCEL I Po �� D FEES This permit is hereby Issued under the of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON applicable provisions Resolutions to do work been paid. Date /afro) Receipt NO. • wwas%n n e .a n r.AId V. A.AFSS0H PINK -INSPECTOR GOLDENROD -APPLICANT N CDF FIRE SAFE REQUIREMENTS /74�E ti Lam, •� AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections 'will be made by the Butte County Building Department for compliance. 1272..00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Drivewav Standards 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other appurtenant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [� 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [X] 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. ] 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. tt] 1273.05 Turnarounds.' If'required, will have a minimum turning radius of 40 feet from the center of the road. [�] 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [�(�] 1270.10 Width. All driveways shall provide a minimum 10 foot traf f is lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of 3:.'. AP # PERMIT # NAME 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [yJ 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [Y} 1. Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. [ ] 1. All parcels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from 411 property lines and/or the center of the road. [ 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r f= --gal inspection of a building permit. Page 2 of 3 AP # PERMIT # Other Recxuirements NAME [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves if Building Setback is Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed 10% of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3 I CDF FIRE SAFE REQUIREMENTS AP# PERMIT # NAME Under authority of PRC 4290, the following checked. items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. 0 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards [1�1 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other appurtenant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [� 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [u] 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. ] 2. The length of vertical.curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. �f] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [�] 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [(,] 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of -3--, AP # PERMIT # NAME (X] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than.800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [�] 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [Y} 1. Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. [ ] 1. All parvels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. [�] 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction �r fi:ial inspection of a building permit. Page 2 of 3 AP # PERMIT # NAME OtherRequirements [ ) If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves if Building Setback is Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed 10% of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials 7-8-�7 O� Date Signature Page 3 of 3 MINOR USE PERMIT BUTTE COUNTY PLANNING COMMISSION `UN 2 4 IM DATE 96-01 PERMIT NO. AP 068-210-109 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Lloyd Hansen is hereby granted a Minor Use Permit in accordance with application filed: 7/5/95 to allow a second dwelling on property zoned A -R located at 21 Buehler Avenue, Oroville. 1. Failure to comply with the conditions specified herein as the basis for approval of application and issuance of Permit, constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Section 24-62. 2. Unless otherwise provided for in a condition to a Minor Use Permit, all conditions must be completed by the permittee within 24 months of the delivery of the countersigned permit to the permittee. 3. If any use for which a Minor Use Permit has been granted is not established within two year of the date of receipt of the countersigned permit by the permittee, the permit shall be come null and void and reapplication shall be required to establish the use. 4. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Perm ittee. FINDINGS: Section 1: Environmental Findings. A. Find that this project is Categorically Exempt from environmental review; and Section 2: Zoning Ordinance Findings. A. That the proposed location, size, design, and operating characteristics of the proposed use is in accordance with the purpose of this Ordinance, the purpose of the zone in which the site is located, the Butte County General Plan, and the development policies and standards of the County; and B. That the location, size, design, and operating characteristics of the proposed use will be compatible with and will not adversely affect or be materially detrimental to adjacent uses, residents, buildings, structures, or natural resources, with consideration given to: 1. Harmony in scale, bulk, coverage, and density; 2. The availability of public facilities, services and utilities; 3. The harmful effect, if any, upon desirable neighborhood character; 4. The generation of traffic and the capacity and physical character of surrounding streets; 5. The suitability of the site for the type and intensity of use of development which is proposed; 6. Any other relevant impact of the proposed use. C. That the proposed location, size, design, and operating characteristics of the proposed use and the conditions under which it would be operated or maintained will not be detrimental to the public health, safety, or welfare, or materially injurious to properties or improvements in the vicinity. D. That the proposed use will comply with each of the applicable provisions of the Chapter, except for an approved Minor Variance. Section 3: Action. A. Subject to the findings indicated in Sections 1 and 2 of this report, move to approve the Use Permit for Lloyd Hansen on AP# 068-210-109 to allow a Second Unit. Approval shall be subject to the following conditions: B. Minor changes may be approved administratively by the Director of Development Services, or designee, upon receipt of a substantiated written request by the applicant. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination, as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. If no changes are made prior to recordation of the parcel map, this condition shall be considered to have been met. C. Conditions of Approval: 1. The Second Unit shall not exceed 1200 square feet. 2. Provide two additional off-street spaces. 3. An attached or detached garage or carport with a maximum exterior dimension 20' by 24' is permitted. 4. Adequate sewer and potable water facilities shall be provided as determined by the Butte County Environmental Health Division. 5. Either the existing single family dwelling or the Second Unit shall be owner occupied. Verification of ownership shall be required prior to permit issuance and annually thereafter by submittal of a declaration in a form specified by the Director of Development Services or designee. 6. No permits for any additional dwelling may be approved unless the Second Unit is first removed. 7. Applicant will need to install septic system under permit from the Butte County Environmental Health Division. 8. Applicant must also comply with all other applicable State and local statutes, ordinances, and regulations. I hereby declare under penalty of perjury that 1 have read the foregoing conditions, that they are in fact the conditions which were imposed upon the granting of this use permit, and that I agree to abide fully by said conditions. Dated:_ Applicant NOTE: Issuance of this Minor Use Permit does not waive requirement of obtaining Building and Health Department permits before starting construction and their approvals prior to use or occupancy, nor does it waive any other requirements. CC: Land Development Division Building Division Health Department Department of Forestry Bu a County Planning Commission Chairman 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7601 FAX: (916) 538-7785 June 24, 1996 Lloyd Hansen 21 Buehler Ave. Oroville, CA 95966 CERTIFIED MAIL Re: Minor Use Permit, AP 068-210-109 Dear Mr. Hansen: Enclosed is your validated Minor Use Permit No. MUP 96-01 to allow a Second Unit on property zoned A -R, located on the south side of Buehler Ave. approximately 600 feet west of Arbol Ave. Oroville. Should you have any questions regarding this matter, please contact this office between 8:00 a.m. and 4:00 p.m., Monday through Thursday. Sincerely, Bill arrel Qifector of Development Services WF:pa Enc. cc: Land Development Division Building Division Environmental Health Department of Forestry j:\temp\up7 MINOR USE PERMIT BUTTE COUNTY PLANNING COMMISSION '4b 24 10 DATE 96-01 PERMIT NO. AP 068-210-109 ASSESSOR'S PARCEL NO. Pursuant to the provisions of the Zoning Ordinance of the County of Butte and the special conditions set forth below: Lloyd Hansen is hereby granted a Minor Use Permit in accordance with application filed: 7!5/95 to allow a second dwelling on property zoned A -R located at 21 Buehler Avenue, Oroville. 1. Failure to comply with the conditions specified herein as the basis for approval of application and issuance of Permit, constitutes cause for the revocation of said permit in accordance with the procedures set forth in the Butte County Zoning Ordinance, including Butte County Code Section 24-62. 2. Unless otherwise provided for in a condition to a Minor Use Permit, all conditions must be completed by the permittee within 24 months of the delivery of the countersigned permit to the permittee. 3. If any use for which a Minor Use Permit has been granted is not established within two year of the date of. receipt of the countersigned permit by the permittee, the permit shall.be come null and void and reapplication shall be required to establish the use. 4. The terms and conditions of this permit shall run with the land and shall be binding upon and be to the benefit of the heirs, legal representatives, successors, and assigns of the Permittee. FINDINGS: Section 1: Environmental Findings. A. Find that this project is Categorically Exempt from environmental' review; and Section 2: Zoning Ordinance Findings. A. That the proposed location, size, design, and operating characteristics of the proposed use is in accordance with the purpose of this Ordinance, the purpose of the zone in which the site is located, the Butte County General Plan, and the development policies and standards of the County; and B. That the location, size, design, and operating characteristics of the proposed use will be compatible with and will not adversely affect or be materially detrimental to adjacent uses, residents, buildings, structures, or natural resources, with consideration given to: 1. Harmony in scale, bulk, coverage, and density; 2. The availability of public facilities, services and utilities; 3. The harmful effect, if any, upon desirable neighborhood character; 4. The generation of traffic and the capacity and physical character of surrounding streets; 5. The suitability of the site for the type and intensity of use of development which is proposed; 6. *Any other relevant impact of the proposed use. C. That the proposed location, size, design, and operating characteristics of the proposed use and the conditions under which it would be operated or maintained will not be detrimental to the public health, safety, or welfare, or materially injurious to properties or improvements in the vicinity. D. That the proposed use will comply with each of the applicable provisions of the Chapter, except for an approved Minor Variance. - Section 3: Action. A. Subject to the findings indicated in Sections 1 and 2 of this report, move to approve the Use Permit for Lloyd Hansen on AP# 068-210-109 to allow a Second Unit. _Approval shall be subject to the following conditions: B. Minor changes may be approved administratively by the Director of Development Services, or designee, upon receipt of a substantiated written request by the applicant. Prior to such approval, verification shall be made by each Department or Division that the modification is consistent with the application, fees paid, and environmental determination as conditionally approved. Changes deemed to be major or significant in nature shall require a formal application for amendment. If no changes are made prior to recordation of the parcel map, this condition shall be considered to have been met. C. Conditions of,Approval: 1. The Second Unit shall not exceed 1200 square feet. 2. Provide two additional off-street spaces. 3., An attached or detached garage or carport with a maximum exterior dimension 20' by 24' is permitted. 4. Adequate sewer and potable water facilities shall be provided as determined by the Butte County Environmental Health Division. 5. Either the existing single family dwelling or the Second Unit shall be owner occupied. Verification of ownership shall be required prior to permit issuance and 1 annually thereafter by submittal of a declaration in a form specified by the Director of Development Services or designee. c' No permits for any additional dwelling may be approved unless the Second Unit is first removed. V. Applicant will need to install septic system under permit from the Butte County Environmental Health Division. X Applicant must also comply with all other applicable State and local statutes, ordinances, and regulations. Rm&j declare under penalty of perjury that I have read the foregoing conditions, that they mkiact the conditions which were imposed upon the granting of this use permit, and that I Oto abide fully by said conditions. Datect— Applicant NOTE Mance of this Minor Use Permit does not waive requirement of obtaining Building and HoWepartment permits before starting construction and their approvals prior to use or occupam&nor does it waive any other requirements, CC: -bad Development Division Iftig Division Raft Department. i piwlment of Forestry Butte County Planning Commission Chairman P RMIT EXPIRES OWNER Lloyd Hansen owner _ CONTR. ILO CATION (A.P. s ) 21 Buehler Ave., Oroville 1 OFFICE COPY 1 - Address i GteBy—� MEIC .Meter By Date/` / Temp. Calms__-_ - -- ---- - - Temp. Elec. Serv. Called PG&E Temp. Gas Serv. Called PG&E i JOB FINALED / stucco COUALTY OF BOTrtE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback Z-5 ZZ " Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor StemwaII Sldin To out 0 - Slab Roof Sheath) Water Pi in Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Stemwa I Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for physically handica ed Conformance of ex. structure Appliances Gas Pi in & T st Temp. as Slab Final 7,7 Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rough — r Reinf. Steel Final Fixtures Bond Beam I At 4 t FIRIR SPRINKLERS Motors stucco nal Subpanels Mesh MECHANICAL Gird. Fault Prot. Scratch rHeating Service Brown oling Temp. PoleFinish cts Underaround Z7 /G D interior Lath I Ventilation Permanent Door Closer I Final �, Final MOBILEHOME UTILITIES ------------------ Elec. Service Elec. Pedestal Water Piping Sewer Gas Piping MOBILEHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS d K- (NOTE: An entry must be made on this form each time you visit the job site.) �A i�COU hY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 Q 7 County Center Drive, Orovi Ile — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE BUILDING OR PROPERTY ADDRESS A routine inspection indicates that the following violations of County Ordinance exist att e above address and should be corrected. Please notify this office when cor ction of work is completed. If you have any question pertaining to this matter,r need additional explanation, please contact this office ii/ym�mediat�eell�y. i o�'`/1,r��u,L`" .times 1 t�� -! Oe L�leQ.ri� oe ff/ %% Id `/ f V r i ♦ Q Date / ' ,7, 14 ` 19 x/32 -SO � g-zi-els ,rte, o eae=,G)L& - � COUNtY OF BUTTE DEP7tRTMENT OF PUBLIC WORKS �9 Oleander Avenue, Chico — Phone 3434211, ext. 70 County Center Drive, Oroville — Phone 534-4541 `556 r Skyway and Elliott Road, Paradise — Phone 877-3435 "l CORRECTION NOTICE BUILDING OR PROPERTY ADDRESS A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this i�m,.a,tteerr, need additional explanation, please contact this office immediately. e Inspector Date 1. COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive Orovilfe, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT / , ct/�cOclflQuvca UI my l�Vullly U� OULLV lU OIIl01 UtJUII 111C above-mentioned property for inspection purposes. X �� 4a52 9._,_ Date Signature of Permitee or Agent Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR -QF PUBLIC WORKS Byu�i ding permit expires Date BUILDING Owner SQ. FT. OCC. BUILDING VALUATION Mailing Address txeFhzz,-'tz_ 6 Telephone No. Contractor �W Mailing Address Fireplace Total Valuation D Tlephone No. e Permit Fee 0 Building Address Lk -G7 'LAIC. Plan Checking Fee &/orPenalty Permit Fee $ o ,� PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 A. P. No. _54-11 -g Zonin Panning Water piping 1.50 Each gas water heater or vent 1.50 F 1*_e I(SaZ;q Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Plans Parcel Declaration Parcel Map 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 Bldg. Plans Rec'd Parcel Approval Plans Approval Lawn sprinkler system 2.00 NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ permit Fee $ $ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 %3.Uig Main service 600V OR LESS 100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil Home ❑ Others Main service EA. ADD'L 100 AMP 2.50 � (�+ - Main service OVER e00v 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW CONST, DWELLING O �yp4' OR ADDNS. ACC. 6LDGS. 1 49 20sgft U CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name st y le of: T NEW RESID. BRANCH CIRCUITS NON-RESID, BRANCH CIRCUITS) 2.50ea NEW CONST. (POWER APPARATUS 9 NON- R RESID• SINGLE OUTLET CIR. Ex. Occun(OUTLETS OR FIXTIIRES) g L , x. ccu FIXED APP LNS, OR EO p• OUTLETS (RESID.) EA)J 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 am exempt from the Contractors License Laws of the State of California. Permit Fee $ ;2,l5vq0 $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. Elhave placed on file with the County of Butte a certificate of 'workmen's Compensation Insurance. UPJIecertify that in the performance of the work for which this prmit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that 1 have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $~ , ct/�cOclflQuvca UI my l�Vullly U� OULLV lU OIIl01 UtJUII 111C above-mentioned property for inspection purposes. X �� 4a52 9._,_ Date Signature of Permitee or Agent Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR -QF PUBLIC WORKS Byu�i ding permit expires Date COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center DrNe - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND -PERMIT ASS 5 R CE BER ZONI G g BUILD PERMIT OWZEROY� /e� A)S /Et 33r4y SO. FT. OCC. BUILDING VALUATION OVR S IU ySaL/CiVT . vrt� �T9�96 CONTRACTOR'S NAME l� ELEPHONE CONTRACTOR'S MAILING ADDRESS CONSTRUCTIONLEp�DER - !ADDRESS —/ UNKNOWN Fireplace Total Valuation $ LENDER'S MAILING Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING Ag`gF PLUMBING PERMIT Filing Fee /000 Each Trap 2.00 4,00 Repair drainage or vent piping 2.00 Water piping , C) v LOT NO. SUBDIVISION NAMEPARCEL MAP Each qas water heater or vent 2.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE � SF ❑ Duplex❑ Mobilehome❑ Other 4 )"I,'KQ/ 45 SPECIFY Building sewer Lawn sprinkler system 2.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities❑ Installation[] Other Describe work: PLUMB - %�oa- 43 P* �o 3 Z: Z Z Permit Fee $ �QQ Contractor ELECTRICAL PERMIT Filing Fee 3.00 Main service jp0 AMP ORV OR LESS5.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.& OR ADDNS. ACC. BLDGS. 2¢sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEw CONSTR MULTI -OUTLET 2.50 ea NON-RESID. BRANCH CIRC ITS NEW CONSTR. POWER APPARATUS 11 NON-RESID, (SINGLE OUTLET CIR. Ex. Occup(bUTLETS OR FIXTURES 50@� eAL�10Q FIXED APP LNS. OR Ex. (FIXED (RESID,) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 6.25 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. IUf I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 3.00 Heating Cooling Hood 2.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County 1 consequence of the granting of this permit. p. X� _ Date —iQ`—a f� Signature of Applicant — Ownerff Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 33 stories in h ight. Mobile Home Installation Fee $ Land Development Fee $ TOTAL PERMIT FEE $ J OCcUP. GROUP I TYPE of CONST. F PARCEL PD HD ISSUE This permit is hereby issued under sio f the Butte County Code and/or w i dica d a ove for which IR CTOR�OF PUBLIC /�, By. u�.Y/(/ PERMIT EXPIRES Date_ the applicable provi- resolutions to do fees have been paid. WORKS Dapte 7—�j�� /y, - //—FO Receipt NO. �l ✓ WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMI!NT OF PUBLIC WORKS PERMIT N 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 l /,/, Z APPLICATION AND PERMIT ASS SSOR PARCEL N MB ER 3rr_�7_ ZONI G ,Q BUILDING PERMIT ow R 7c aYb ,os C -Ai T LEPHONE 5 33 �t qi 3 SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS Z/ 4f EICIUE O�O!/1l,LG Gq �s-p�S, _C CONTRACTOR'S NAME !4/v `f TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDF,,�i/ ✓ _ / UNKNOWN C Total Valuation N Filing Fee 1Z $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ Zv� vv ARCHITECT OR ENGIh,1.qER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 30,0o BUILDING ADDF)SS _ �C PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 ``�� aveeVlu&t Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE o SF ❑ Duplex MobilehomeQ�ther W1 DLA G7.9'6r7 SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition Remodel Utilities Instal o/n ❑ Other Describe work: S� /--t��L [I��(p3Z —%9 Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 6101 OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD'L 100 AMP 2.50 (DWELLING OCCUP.) NEW CONST. y OR ADDNS. \ ACC. BLDGS. 21: sq CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one):NEW ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the BUSIne$$ and Professions Code and my license is in full force and effect. License No. Classification Er -l—, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR.TI-OUTLET2.50 ea NON-RESID BRANCH CIRC ITS CONSTR. / POWER APPARATUS 6) NON -RESID. \SINGLE OUTLET CI R. EX. Occup OUTLETS OR FIXTURES gA�,�j FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESID,) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ i have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate o Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee S Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue[ against said County in consequence of the granting of this permit. X V�/� Z IF -C) o�y 1�H'�1--,a Date �� —l� _ Signature of Applicant — Owner Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ 36), C, OCCUP. GROUP I TYPE OF CONST. -I PARCEL PD I NO I ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which D! TOLF PUBLIC By PERMIT EXPIRES Dat the applicable provi- resolutions to do fees have been paid. WORKS Date '3 y Receipt No. -5' WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT r V COUNTY OF BUTTE - DEPAJRT.MEWT OF PUBLIC WORKS / PER IT NO 7 County Center Drive - Or(tville, California 95965 - Telephone 916/534-4 41 6 .� 2, APPLICATION AND PERMIT A SSESSO PAR7/^ C EL N BAER -- � ZONING UILDING PERMIT OWNERGaC_3`P�ONE G/'D , SO. FT. OCC. BUILDING VALUATION O�RES�C� O/`-�/Vl�� L o�ry'/ CONTRACTOR'S NAME f ewlVaLL TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Fee $ 10.00 LENDER'S MAILING ADDRESS -Filing Permit Fee fe7, $ /O ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEE S MAILING ADDRESS ' Permit fee $ BUILDi�. I� ADOg;�`�L�L SS �S PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 1� [—L C=� Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5,00 Gas piping system 1 - 5 outlets USE OF STRUCTURE �� 4/�1'J�(�E SF ❑ Duplex ❑ Mobi lehome ❑ Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑-1 /Uti ies Installation ❑ Other Describe work: -0041/9 'ec 8p�3z7�%lr' Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100 AMP OROR LESS5.00 S� r,6 -Al, &131 -SO Main service EA. ADD'L too AMP 2.50 NEW CONST. (DWELLING OCCUP.NI OR ADDNS, l ACC, BLDGS. / 20 sgft CONTRACTORS LICENSE LAW I declare under penaltyperjury of p y (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business F1BAL@1 and Professions Code and my license is in full force and effect. License No. Classification 56 I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR ..OUTLET 2.5Oea NON.RESID BRANCH CIRC ITs NEW CONSTR. / POWER APPARATUS D) NON.RESID. %SINGLE OUTLET CIR. Ex. OCCUR(OUTLETS OR FIXTURES @ Ex. Occup.(OUTLETS FIXED P(RESID,)REA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject 1� to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against 'd Co ty in , onsequence of the granting of this permit. G, _�— �/y X s' Date exS— Signature ' Applicant — Owner)Q Conrrocror ❑ Agenr ❑ An OSHA permit is required for excavations over 5'f)" deep and demolition or construct- ion of structures over 33 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ _50 U OCCUP. GROUP I TYPE OF CONST, PARCEL PO ND ssuE This permit is hereby issued under sion f the Butte County Code and/or wor ndicated bove for which D EC OF PUBLIC BY t� �/j PERMIT EXPIRES Date /V the applicable provi- resolutions to do fees have been paid. WORKS C' Date —/7�2— Receipt No. / / I3 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPAW-OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLmATION AND PERMIT PERMIT NO. 7J/ r - ASSESSOR PARCEL NUMBER 68-21-45 ZONING ev BUILDING PERMIT OWNER Lloyd Hansen TELEPHONE 533-4913 SO. FT. OCC. BUILDING VALUATION 3rd & 4th renewals OWNER'S MAILING ADDRESS 21 Buehler Avenue Oroville CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee -1-2 original X 2 $ 40.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 50.00 BUILDING ADDRESS ler A Oroville PLUMBING PERMIT Filing Fee 10.00 9 Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5,00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other ' SPECT Y Building sewer 5.00 Mobile Home S G W 10.00 e TYPE OF WORK New ❑ Addition ❑ RegISFE}—•b"t ties^&—kistallation ❑ Other ❑ Describe work: 3rd & t1 r aT,rr-ePesaml-,<632-,7_-7-9 Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100 AMP OROR LESS10.00 0,00 w [•LQ��/�S'. last renewal/2846-82 ADD 960—VIC Main service EA. ADD -L 100 AMP 2.50 Z,,;% NEW CONST. DWELLING OCCUP.& OR ADDNS. ( ACC. BLDGS. t 2/2 Os ft CONTRACTORS LICENSE LAW I declare under en It Of p y perjury iUr y (Check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification 1K I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR ULTI.OUTLET 2,50 ea NON.RESID BRANCH CIRCUITS NEW CONSTR ( POWER APPARATUS &') NON-RESID, SINGLE OUTLET CIR, Ex. Occup(o OR FIXTURES .20@030 ZAL@30 FIXED APPLNS. OR FIXED A EX. OCCUp. OUTLETS (RESID.) EA.) 1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. faf 1 shall not employ any person in any manner so as to become subject JA' to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue gainst ai Coun y in onsequence of the granting of this permit. ate / C _,r i( Signature o Applicant — OwnerX Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $7�, oo §g;ge occuP. GROUP I TYPE OF CONST. PARCEL PD I ND I ISSUE This permit is hereby issued under Sion o the Butte County Code and/or :tedove for which wor kicatei/ TOR OF PUBLIC B PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS �! r� 10/17/84 Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT b`• . . 7 G y ,COUNTY OF BUTTE - DEMARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-45 ` APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER - -3tt. /7- 45 ZON4G '(11 BUILDING PERAFri- OWNS oz -D �/^�/� / 7A7D"/D�R LESS Thy p,Hp/Iv�/3 ✓�3 SO. FT. OCC. BUILDING VALUATION ` 00 OW(N�—EERR'S MAILING AVC, D �vll 9S9�S CONTRACTOR'S NAME DGr V6 TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDE UNKNOWN Total Valuation $ -7&00.,00 Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ • 00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee hh $ 2_ 00 Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 7 .OD BUILDING ADDRESS�E �V� , 2!1B /LC/�//G� PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 6720VILt"61 Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUC=0Lawn� -' SF ❑ Duplex❑ Mobilehome❑ Other SPE IFY Building sewer sprinkler system 5.00 TYPE OF WORK New ❑ Addition Remo el ❑ Utilities ❑ Installation❑ Other ❑ Describe work: AL> -9AJ1!> -���5'� ��e � 5r ---c- P` 1032 7- % j Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100V OR LESS 100 AMP OR LESS 5.00 ' Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCi OR ADDNS. ACG. BLDGS. I 20 sq ft �dO CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification 21,11, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR I -OUTLET 2.50 ea NON.RESID BRANCH CIRC TS NEW CONSTR. /POWER APPARATUS D1 NON-RESID, %SINGLE OUTLET CIR. I Ex. Occup OUTLETS OR FIXTURES 50@25 IXED APPLNS. OR \ Ex. OccuXUTLETS (RESID,) EA./ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ X00 Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate 9f Consent to Self -Insure. LTJ ' shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee S Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. all liabilities, j dgments, costs,nandeexpen expenses which may in any wayaacc accrue against said County in consequence of the granting of this permit. X-� �_ �Ly•_"cam CTs Date Signature of Applicant — Owner Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ /0-5-00 OCCUP. GROUP TYPE of //CONST. P ARCEL ✓ ✓ ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRE C OF PUBLIC BY P I EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date/a�3`!— /Z—✓7- Receipt No. _6- WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR. GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORK PERMIT NO. 7 County Center Drive - Oroville, California 95965,- Telephone 916/534 4541 h '� l� APPLICATION AND PERMIT �Q ASSESSOR PA C L NUMBE —2-/-� ZONING BUILDING PERMIT OWNERSQ. GLO b 1-1AAJ9, FV ��i'i3 FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS V i�uE,�t Avec 040 y1& -(_e al- sT CONTRACTOR'S NAM® TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDIKESS Permit Fee Z/ $ ZZ -env ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fe $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 32 -ate % /2�/$ BUIL S/ AD1✓v( Z PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 & 0111&ie� Water piping LOT NO. SUBDIVISION NAMEPARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Ut' itties [I Installation ❑ Other [I Describe work: /�./- ���✓�3Z�d Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.M) OR ADDNS. ACC. BLDGS. 2�Sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions Of Chapt. 9, Div. 3 of the Business Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR.(I�OUTLET NON.R ESIO BRA ANCH CIRC ITS 2.50 ea NEW CONSTR POWER APPARATUS y NON-RESID. SINGLE OUTLET CIR. / Ex. OCCUp OUTLETS OR FIXTURES BAL21 and IXED APPLNS. oR Ex. Occup.{OUTLETS (RESID.) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shal I be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue again id �!nty 'n consequence of the granting of this permit. %� �z; Date �" I`ll Signature of Applicant — OwnerlK Contractor E]AgentEl An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures/ 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OCCOP. GROUP I TYPE OF CONST, I PARCEL PO ND ssuE This permit is hereby issued under the applicable provi- sion f the Butte County Code and/or resolutions to do we i icated above for which fees have been paid. CTOR OF PUBLIC WORKS BY Date PERMIT EXPIRES Date— -over Receipt No. ((—I l3 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO 7 County Center Drive - Oroville, California 95965,• Telephone 916/534-4541 • APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 68-21-45 ZONING BUILDING PERMIT OWNER Lloyd Hansen TELEPHONE 533-4913 SO. FT. OCC, BUILDING VALUATION 2nd & 3rd renewals OWNER'S MAILING ADDRESS 21 Buehler Avenue, Oroville CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee 2 origins X 2 $ 44.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 54.00 BUILDING ADDRESS - vt la L' Buehler Avenue, 0 PLUMBING PERMIT Filing Fee 10.00 211 t Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobi lehome ❑ Other 'garage addition SPECIFY Building sewer 5.00 Mobile Home I S I G JW 1 10.00 e TYPE OF WORK New -TR] Addition ❑ Remodel ❑ Utilities ❑ Installation El Other ❑ Describe work: MM 2nd & 3rd renewal/6132-80 • Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 st renewal/2847- 2 Main service EA. ADD'L 100 AMP 2.50 NEW CONST.(DWELLING OCCUP.& OR ADDNS. ACC. BLDGS. I 2h0SQft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ElI am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ �I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR. MULTI -OUTLET NON•RESID BRANCH CIRC ITS 2,50 ea NEW CONSTR 1 NON-RESID. SINGLE OUTLET CIR. / Ex . Occup(o OR FIXTURES 20@g0e sAL030 IXEDTs Ex. Occup. OUTLETS P(RESID )KEA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I'declare and penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department E:1 a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. �, 1Cit I shall not employ any person in any manner so as to become subject Y�1 to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agains s id?Cot i consequence of the granting of this permit./ /� X ate ; •- l�•_ k"' -�� Signature of Applicant - OwnerW Contractor ❑ Agent ❑ An OSHA permit is required for exc'a`vations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ 54.00 OCCUP. GROUP I TYPE OF CONST, PARCEL PD HD ssuE This p mit is hereby issued under Sion of the Butte County Code and/or or which fees OF PUBLIC wor WE- By PERMIT EXPIRES Date 12/29/84 the applicable provi- resolutions to do have been paid. WORKS Date 7-16 4t Receipt No. 37S WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT u COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville; California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT ERMI ASSESSOR PARCEL NUMBER 68-21-45 ZONING BUILDING PERMIT OWNER Lloyd Hansen TELEPHONE 533-4913 SO. FT. OCC. BUILDING VALUATION 4th Renewal OWNER'S MAILING ADDRESS 21 Buehler Avenue, Oroville CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER None UNKNOWN Total Valuation $ Filing g Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee (2 of Original) $ 22.00 ARCHITECT OR ENGINEER None LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 32.00 BUILDING ADDRESS 21 Buehler Avenue PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 Oroville Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other Garage Addition SPECIFY Building sewer 5.00 Mobile Home FSTG FW F 110-00e TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other [] Describe work:__ 4th Renewal of Permit #6132-80 _ (2nd & 3rd/474-84) Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.& OR ADDNS. ACC, BLDGS. 2th¢sq tt CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification L 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR.( ULT' -OUTLET 2,50 ea NO N.RES'D BRANCH CIRC ITS NEW CONSTR. (POWER APPARATUS .&) NON-RESID. (SINGLE OUTLET CIR. Ex. OCCu BAL@30 P�o Ts OR FIXTURES BAL�30 FIXED Ex. OCCUp- OUTLETS P(RESID.)REA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or,less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate Consent to Self-InS'ure. shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against I Cou in co sequence of the granting of this permit. //1 _,p ! / %� Date (d` 7 Signature of Applicant — Owner F-1 Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ 32.00 OCCUP. GRouP TYPE OF CONST. PARCEL PD ND SSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which IRE WIF PUBLIC By PERMIT EXPIR.,& D e. 12-295 the applicable provi- resolutions to do fees have been paid. WORKS cy Date__'—� ^ ate Receipt No. ,1 WHITE-D.P.W., YELLOW-ASSGSSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT 13, Nv o Ao�°,Nio U This set of plans and specifications MUSS1- kept on the job at all times and it is unlawful to make any changes or alterations on same without writ,}en permission from the Department of Pub' lie Works, County of Butte. The Bldg. Setback shall be 5 ft. -from the side property line and 5o ft. from the centerline of the road, permitting. a maxi- mum of a 2 ft. eave overhang but entirely out -of all easements. EW BUTTE COUNTI BUILDING DEPARTMENT APPROVED 1 r I i' i' i i U This set of plans and specifications MUSS1- kept on the job at all times and it is unlawful to make any changes or alterations on same without writ,}en permission from the Department of Pub' lie Works, County of Butte. The Bldg. Setback shall be 5 ft. -from the side property line and 5o ft. from the centerline of the road, permitting. a maxi- mum of a 2 ft. eave overhang but entirely out -of all easements. EW BUTTE COUNTI BUILDING DEPARTMENT APPROVED ri rn C-1 I � == f1.-0 - -4 - ft -4 . ro C rh � �� �1 1 - i f1.-0 - -4 . .. �• �-�=. 1 �ad L...46 .a �,.�✓Gx,, oma. � / 1 l ME,CHAN IC_AL ' Check Ust ❑ Permit ElUnderfloor Eta e ❑ Underfloor Supply Plenum; (1) One-story. (2) Clearances. (3) Combustible material. (4) Insulation and vapor barrier. (5) Access. (6) Catch receptacles and registers. (7) Fire -stopping. (8) Boots. (9) Supply ducts. (10) Gas lines and plumbing cleanouts. `•` ❑ Ducts: (1) Size. (2) Materials. (3) Support. (4) Fittings. (5) Wrapping. (6) Insulation. (7) Clearances - ground, crawlspace, cleanouts, plumbing, etc. ❑ Combustion Air: (1) Size. ❑ Refrigerant Piping: (1) Material. (2) Support. (3) Fittings. (4) Insulation. ❑ Framing Stage ❑ Heating: (1) Approved appliances. (2) Accessibility. (3) Clearances. (4) Combustion air. ❑ Vent and Connector: (1) Approved. (2) Size. (3) Clearances. (4) Cap. (5) Termination. I I 1 MEC H A N I C A L • Check Last ❑ Permit ❑ Underfloor Sta e ❑ Underfloor Supply Plenum,, (1) One-story. (2) Clearances. (3) Combustible material. (4) Insulation and vapor barrier. (5) Access. (6) Catch receptacles and registers. (7) Fire -stopping. (8) Boots. (9) Supply ducts. (10) Gas lines and plumbing cleanouts. ❑ Ducts: (1) Size. (2) Materials. (3) Support. (4) Fittings. (5) Wrapping. (6) Insulation. (7) Clearances - ground, crawlspace,'cleanouts, plumbing, etc. ❑ Combustion Air: (1) Size. ❑ Refrigerant Piping: (1) Material. (2) Support. (3) Fittings. (4) Insulation. ❑ Framing Stage ❑ Heating: (1) Approved appliances. (2) Accessibility. (3) Clearances. �• (4) Combustion air. ❑ Vent and Connector: (1) Approved. (2) Size. (3) Clearances. (4) Cap. w (5) Termination. 13•o`i IF 1 eossES : 2"BIZ'► Jo 15r5 @ lip D.G • IEGQ 'D. VXIVCo 16`o.o o. k. ME•CHAN I C A L • ' Check Ust ❑ Permit ❑ Underfloor Stage ❑ Underfloor Supply_Plenum; '(1) One-story. (2) Clearances. (3) Combustible material. (4) Insulation and vapor barrier. (5) Access. (6) Catch receptacles and registers. (7) Fire -stopping. (8) Boots. (9) Supply ducts. (10) Gas lines and plumbing cleanouts. ❑ Ducts: (1) Size. (2) Materials. (3) Support. (4) Fittings. (5) Wrapping. (6) Insulation. (7) Clearances - ground, crawlspace,'cleanouts, plumbing, etc. ❑ Combustion Air: (1) Size. ❑ Refrigerant Piping: (1) Material. (2) Support. (3) Fittings. -(4) Insulation. ❑ Framing Stage ❑ Heating: (1) Approved appliances. (2) Accessibility. (3) Clearances. (4) Combustion air. ❑ Vent and Connector: (1) Approved. (2) Size. (3) Clearances. (4) Cap. (5) Termination. • r • Y� N78900 .ate. �- io psi ,4cal�o _ /Z`o Vis°' zt,�: � _— ,et BUTTE COUNT~ X — BUILDING DEPARTMENT - - . AP P_R OV� s .�.d ::z�c� � s 4z 0,` C, ./ �77AA5!5 sTv� ... s�� .•v�� aB� tr.�,� X02 L�i4�.s .�XG��,�,t16 ��s..�;:��:. ;.� -= �,.: — slc�/IJ C7� C!iLGGl�tr(/S /frUY) �LILGLGvt�C/ /�+�c77.(J6•S 77- SUBJECT:- 5E"1 �, '� �•� C'ALavrJs CLIENTS NAME JOB NO. COO �AOCIATES _ ' JOB DES RIPTION"0070 . a—PA `o"""`TAw" a0�0 PARK Av■Nu. , DATE SHEET OF SHEETS AMERICAN INSTITUTE OF STEEL CONSTRUCTION t, v -F- d x x VII SHAPES Properties for designing Y br Compact Section Criteria Plastic Modulus VV SHAPES Torsional Warping bf Fr d Properties for designing zx Zy Weight per Ft. rT d�� Constant J Constant Cw Flange Web Af Elastic Properties Area A DepthThick- d Thick- Hess Width Axis X -X tW Axis Y -Y Designation bf ess tw Ksi Ksi Ksi In!' In.e In! In! 190 3.59 0.654 tfn - I S r I S r 143 in? In. In. In. In. In.4 In! In. In! In! In. W 12X190 55.9 14.38 12.670 1.736 1.060 1890 263 5.82 590 93.1 3.25 X161 47.4 13.88 12.515 1.486 0.905 1540 222 5.70 486 77.7 3.20 X133 39.1 13.38 12.365 1.236 0.755 1220 183 5.59 390 63.1 3.16 X120 35.3 13.12 12.320 1.106 0.710 1070 163 5.51 345 56.0 3.13 X106 31.2 12.88 12.230 0.986 0.620 931 145 5.46 301 49.2 3.11 X 99 29.1 12.75 12.192 0.921 0.582 859 135 5.43 278 45.7 3.09 X 92 27.1 12.62 12.155 0.856 0.545 789 125 5.40 256 42.2 3.08 X 85 25.0 12.50 12.105 0.796 0.495 723 116 5.38 235 38.9 3.07 X 79 23.2 12.38 12.080 0.736 0.470 663 107 5.34 216 35.8 3.05 X 72 21.2 12.25 12.040 0.671 0.430 597 97.5 5.31 195 32.4 3.04 X 65 19.1 12.12 12.000 0.606 0.390 533 88.0 5.28 175 29.1 3.02 W 12X 58 17.1 12.19 10.014 0.641 0.359 476 78.1 5.28 107 21.4 2.51 X 53 15.6 12.06 10.000 0.576 0.345 426 70.7 5.23 96.1 19.2 2.48 W 12X 50 14.7 12.19 8.077 0.641 0.371 395 64.7 5.18 56.4 14.0 1.96 X 45 13.2 12.06 8.042 0.576 0.336 351 58.2 5.15 50.0 12.4 1.94 X 40 '11.8 11.94 8.000 0.516 0.294 310 51.9 5.13 44.1 11.0 1.94 W 12X 36 10.6 12.24 6.565 0.540 0.305 281 46.0 5.15 25.5 7.77 1.55 X 31 9.13 12.09 6.525 0.465 0.265 239 39.5 5.12 21.6 6.61 1.54 X 27 7.95 11.96 6.497 0.400 0.237 204 34.2 5.07 18.3 5.63 1.52 W 12X 22 6.47 12.31 4.030 0. 4 0. 0 156 25.3 4.91 4.64 2.31 0.847 X 19 5.59 12.16 4.007 0.3 0.2 130 21.3 4.82 3.76 1.88 0.820 X 16.5 4.87 12.00 4.000 0.269 k.230 1116,105 17.6 4.65 2.88 1.44 0.770 X 14 .4.12 11.91 3.968 0.224 O 98 88.0 14.8 4.62 2.34 1.18 0.754 12 �� w 8 x27 a AMERICAN INSTITUTE OF STEEL CONSTRUCTION t, v -F- d x x VII SHAPES Properties for designing Y br Compact Section Criteria Plastic Modulus Nominal Torsional Warping bf Fr d Fye Fr. zx Zy Weight per Ft. rT d�� Constant J Constant Cw Af 2tf tW Lb- In. Ksi Ksi Ksi In!' In.e In! In! 190 3.59 0.654 3.65 - 13.6 - - 48.9 23600 311 143 161 3.53 0.746 4.21 - 15.3 - - 30.6 18700 259 119 133 3.47 0.815 5.00 - 17.7 - - 17.6 14400 210 96.2 120 3.44 0.963 5.57 - 18.5 - - 12.9 12500 186 85.5 106 3.41 1.07 6.20 - 20.8 - - 9.10 10600 164 74.9 99 3.39 1.14 6.62 62.2 21.9 - 7.45 9740 152 69.5 92 3.38 1.21 7.10 54.1 23.2 - - 6.01 8870 140 64.2 85 3.36 1.30 7.60 47.1 25.3 - - 4.80 8060 129 59.1 79 3.34 1.39 8.21 40.5 26.3 - - . 3.85 7330 119 54"4 72 3.33 1.52 8.97 33.9 28.5 - - 2.94 6550 108 49.2 65 3.31 .1.67 9.90 27.8 31.1 - - 2.19 5790 97.0 44.1 58 2.75 1.90 7.81 44.7 34.0 - 57.3 2.10 3580 86.5 " 32.6 53 2.74 2.09 8.68 36.2 35.0 - 54.1 1.59 3170 78.1 29.2 50 2.19 2.35 6.30 - 32.9 - 61.2 1.79 1880 72:5 21.4 45 2.18 2.60 6.98 55.9 35.9 - 51.3 1.32 1650 64.8 19.0 40 2.16 2.89 7.75 45.3 40.6 - 40.0 0.956 1440 57.5 16.8 36 1.77 3.45 6.08 - 40.1 - 41.0 0.830 873 51.6 11.9 31 1.75 3.98 7.02 55.4 45.6 - 31.7 0.536 728 44.1 10.1 27 1.74 4.60 8.12 41.3 50.5 - 25.9 0.351 611 38.0 8.62 7.20 4.75 - 47.3 - 29.5 0.292 164 29.3 3.6° Z1.03 . 1.01 8.70 5.74 - 51.3 64.5 25.1 0.181 131 24.7 2.91 16.5 0.975 11.2 7.43 49.3 52.2 62.4 24.3 0.112 99.2 20.6 2.32 14 0.957 13.4 8.86 34.7 60.2 46.9 18.3 0.069 80.0 17.3 1.85 AMERICAN INSTITUTE OF STEEL CONSTRUCTION D m m O D Z Z -1 C -I m O T N m m r 0 O Z 1 M c A O z D 3 m z A D z Z -•1 C -i m O T m m m r 0 O Z m C 0 .-1 0 z r = 36 k$E Cy=36ksi T 0 w rFy 0)a =V RC1 C' 00 d m. N m ? IP c toc _.zFF-• Span in Feet dm° o n W d nm (nvlm M 7 701 0� C r-0 > x �cx CD .wN Span in Feet O tNr1A WNN W00-1 Ori(r71 Fr••OID OO -•V 01 cm A W :E v •"� N N DlO 0 0 vvv �• a m Wt71A N N N NWWWW WWAA AAcn to Of QI VOO tD OIO = C y� d 0M m m 7 171 ODV AQI =rW C m IOON W to QI OOO W 01 lON Olr O1 W1 -+N CTl Oo Iy�'jIo•IO•I A NNNN -0 W00 V 01 NNNNN to WNr Ui tJ1N 01x0 O s+voino mviDw oral olw iD of 000 i-+ w 0 I� - T d CD 3 CD 1,_ WAW .-�, NNNNW WWWw WAAA(n (JI Cn V w to 1-• V . ID d OVNOlO � 1T101 V000 rW1TV 10N 17100N VWOtD O N r � M N w 0'0 O, to N N(r(n N 0) WWO1Vr 01WrN (.71rrm-i (71NN0 W U:)Of m r (n O -i ANtD to !,j N 3 p Y (O K 7 O a 01010% 01V tor) 01W r ,j 00 tDt00 to 4. r coV rx rW co r W d m X NAW 1710100x• �% NNNNN NNWW WWWAA ACT 0101 V rNWA01 VODON ArntONc71 to ?0 Oo 00 N F+ to �I�I� WW V CD m O N O °i =n 3 OO C 6A.ArN y n tD0 ww0 -- Aw AN r%) cm r 01 WOOF• NN �� 3 CO -- N C my 3 m d N M� N O 171 V NOAI (N71 = 01TV 170 tD 01N••N W 1NT1 VON01W+W OW10 tAJ10 V V FO-• N A W '0 '�, =a f VONAw d Nto 01AW NW(nw wC)Wr j 00171001w 1710 00 `� CD d N c H o o rn N 7 iD o CD C/) .yl (NN f. N WWWAA GI V co Or a V1(710101OI AVOWV VV00 OD tD NVW1000 N W W WA A V101 00 �: � G H f m NAN OI Of OOrr ow _ rrrrr rrrN NNNNN WAA(I1 Qf VVODO rN A 0100 rAVN DD 0100 W 'rI AIA tar) m VA000w 01Nw(M CD,W D0 WVWNA 01-1 to O1 V 00N 61 W N D O m C T.• � 3 a d CN co d _ � m O.•O N y W 1-• O.f 1 N3 b. rrrrr rrrr rr NNN NPI) WW A A(fl V 00 AA(n VOOOrW (n oor(n O 0101 O O A A r m d 00 Q tn. 010V 6N00001 CD VAA rrNNW 01 %4 roo Of On 660x:-46 01NWN N ZD !M A O (''' A F M N C m � a 3w 3 �j CnCIIV NWr OAD N+AVO N rrr rrrr rrrr►- NNNN W w -Ab to VV coO N ( 7101 NAA � N CD W. tO l000r rNWW A171 O1WtD rWOt0 W tD 01 QD ODA;"' Cno A r 0 D1 p1W VN• AVN01r VW000 0101V 0171 WAON A 000 CA AIN v1I A C 3 3vC N r' G o N D d � �121dd3a JNlall�'r+rc . o000 00000 0000 0 00 0 0 _ �. 3 OC F3 O m NrOOtD ODVQf O1 tnAAW W NNrr r 00 O O � n AAO m 01 � No0 t WWCt r W(.71 V0 W Vr(nCD 1i1r VW O -4 W 1Nnoo 3.uns "_ 3 N 3 W b 7 H ..-.: C f9 ti M �• r Cy=36ksi �r a 'Z, itf'Sf `' CqQQ7 dm° o C M 7 C r-0 > x �cx Span in Feet o :E v DlO 0 0 vvv a m O m N N N = C 3 =rW C m NNNN -0 W00 V 01 NNNNN to WNr Nrrrr C WOo VO -rrrr 1nA WNr r Oto 00 V (A 0 I� - d 1,_ N m r (n O -i ANtD to !,j -D WAAAA (m A.h•1T f71 t71 --4 to r 130) 01010% 01V tor) 01W r ,j 00 tDt00 to 4. r coV rx rW co r W wl ol0 O• rn m N �� WW V 0 .01--N my 3 m O- Ar WNv 01•x•• N H o o rn N 7 iD v m d (NN f. N WWWAA GI V co Or AAAA(n WOI V for V1(710101OI AVOWV VV00 OD tD NVW1000 Vto w �: � n_ ow 1.,• pl N O � O 3 a d CN an d d p m (D CD VAA M 3 �j CnCIIV �WOON'p OA1 OAD N+AVO ?WVAww VV coO Iplp•I SIA � N CD Cno NtDto 0 C 3 3vC r' C 3 AAO 0,C d b 7 H ..-.: C f9 ti M �• -0 0 AOW7 V W(An VN , Z.C N NNN00) N v to 000 ham•? 001N 000 001001 t00 CD C T3 CA Q3 CD Cn ohm CD m ca d N N A AIOAI�••!o O Co m d = Qm N N(n r WW (n -j WAAAA WwA CI (7101 O101V N(m CD V00 l0I`CD WO 00Iw N I� tnI Oo AI I� _O O• m �� m d �N• O = m d O d m 1 AAA ACDOQIN WW WWWAA AA(n(n01 01V OOIO bIAI�IW O Cm NO1 N rN AOI COON O100N 01r 00171 A N Of tD o DO p 3N •3 ~ m WAW AV cnr(n N W NN NNWwW WWAA(m Ot01Ol V OOI!n ODI N NtD O Of Ol 01 00WrN VtON 010 171r W tD W I• v Nth (j I CA m° 3' fd ax m W •n rr 00000 00000 00 O o 0 A w. 3 mmd� NO tDt000V01 6AAWW NNrr6 Sn �. C) Oto to ca oNA OI toN 010 1710 O1 N to m •+ N 0 w 3 3 N r NOTE --All Materials & Workmanship Accordance with Recognised Good Pr< of a quality prescribed for the Specified r Uniform Building, Plumbing & Machanical the National Electrical Code. 3Y3 I This set of plans and specifications MUST be kept on the job at all times and it is unlawful to M06 any changes or ratrens on some without _--i written permission fro he Department of Public Works, County of Butte. I �ooT1�S CSS u w�rNC3o�4 �J? EA . W4Y 1 I it � 3 � X3C� Xl? TH'1GK c A setback of 5 ft. from the prpperty lines and a setback of 50ft. from the road centerline shall be clear of structures or equipment except for 2 ft. eave overhang. Provide adequate bracing. fgy p = tI r { (0132-80 BUTTE COUNTY BUILDING DEPAR NT J !`A PVE ' SEE SP463Z7-79 R90-- �z,c-��e y / 6r�+ce AP1�1G�kF3C E MOTES �� rA. LLo H X �o6:.,LS. H: Cbt.VAd4J CA -P 60.-) 6'014C JLce,41SIC i. Provide adequate bracing. +� I j ( P.PoVInE DOUStET 70P P6AM7 i I I i I 3x`l I --a"K y I : 7" i >ly ! i) i i I Pro ide equate bracing. BUT E COU . BUILDIN'4 DEPART APPROVED' f 4/4 F ,, , 1, { y' - `:r9 e�„_„,ne ',w,�,..--TsnFr;'�" ;..a"t'�,':+,5'b�'1`y?tti4•!ry' ;��. ..1'+; S"'1�F��''+^•-s y1'i'f►�'f.-•i`'SF'*' .- Permit#2550-87P,M- Lloyd Hansen 21 Buehler Avenue, Oro 102—•► <o d 44' CV41(— e-��� i OFFICE COPY Address GAS '..Zri'� • Meter By Date Z ELECTRIC j • Meter By Date y � ✓ COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7"Courity Center Drive - Oroville. California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT PERMIT NO. 15 ..11 o ASSESSOR PARCEL NUMBERI �. v d. ZONINGI �^"l f f- /� BUILDING PERMIT OWNER TELEPHONE S0. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS ' CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP (- Water piping 5.00 Each qas water heater or vent 5.00 _�, 0 0 USE OF STRUCTURE SF [IDuplex❑ Mobilehome❑ Other 1 ��/ ���/`' /)) SPECIFY Gas piping system 1 - 5 outlets t 5.00 _5- 00 Building sewer 5.0 0 Mobile Home S G W ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other Describe work: _Y/ GU .0� E Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service eoov OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check.one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification lid" I. as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. / DWELLING OCCUP.86\ 1/20sgft OR AODNS. l ACC. BLDGS. / NEW CONSTR. ULTI.OUTLET 2,50 ea NON-RESIO BRANCH CIRC ITS /POWER APPARATUS &) (SINGLE OUTLET CIR. EX. OCCUp(OUTLETS OR FIXTURES SAL@20@301 0@990 Ex. OCCUp. OUTLETS ((RESID.FIXED A )REA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate � of•Consent to Self -Insure. Ll1h I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should -you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating 17. —5(-) Cooling Hood 3.00 Ventilation penult Fee $ / Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against'said County in consequence of the granting of this permit. X N �'� Date 1 —g9_?7 Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ OCCUP. CONST.TYP! I JFL003[FZW7 I HD I ISSUE V/ This permit is hereby issued undertthe applicable provi- sions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIREC F BLIIr WORKS q(; on By i.+/ //�/, , VDatp /``X// PERMIT'EXPIRES Date Receipt No. x:` z �i K WHIT!-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT V COUNTY OF BUTTE'- DEPARTMENT OF PUBLIC WORKS PERMIT NO p 7 County Center Drive - Oroville. California 95965 - Telephone: 916/538-7541 APPLICATIQN AND PERMIT ASSESSOR P R EL JLL�J ABBE l �J-IJ I/ LO1'- ZONIN BUILDING PERMIT OWNE TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MA I G DD E S CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING AD RESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 0 0 USE OF STRUCTURE SF ❑ � Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 p0 Building sewer 5.00 Mobile Home IS1G W 10.00 ea TYPE OF WORK New Addition❑ Remodel❑ Utilities❑, Installation❑ Other Describe work: G(J Permit Fee $ pCQ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service e00v OR LESS 100 AMP OR LESS 10.00 Main Service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification P-111-1 as the owner, or my employees with wages as their sole compen- 'sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. OR ADDNS. l ( DWELLING OCCUP.e+) ACC. BLDGS. +h�sgft NEW CONSTR MULTI -OUTLET 2,50 ea NON.RESID BRANCH CIRCUITS) POWER APPARATUS e1 SINGLE OUTLET CIR. / Ex. OCcu 20 ® 50C Occup(OUTLETS OR FIXTURES SAL(P30 FIXED APPLNS. R EX. Occup. OUTLETS IIRESID )EAJ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate onsent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shal I be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating 0 Cooling g Hood 3.00 Ventilation Permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue again sai-d�C/ounty ' consequence of the granting of this permit. X �7A' �'— Date 7 ��� "�� Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ -5 C) OCCuP. CONST.TYPC I FWOOJ PARCEL PD NO 1 Iseu This permit is hereby issued under sions of the Butte County. Code and/or work indi above for which DIREC F Pli BY PERMIT XPIRES Date the applicable provi- resolutions to do f s have been paid. I WORKS Date Receipt No. WHITE-D.P.W., Y LLOW-ASSE BOR, PINK -INSPECTOR. GOLDENROD -APPLICANT COUNTY OF BUTTE - Depaltinen£ of Public Works 7 County Center Drive, Oroville, CA 95965 Phone: 916-538-7541 OWNER -BUILDER VERIFICATION Attention Property Owner: An 'owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will.be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) g)e,' 2. I have have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: Name Address City Phone Contractors License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractors License No. 5. I will provide some of the work'but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: Property Owner Social Security Num e Date ?- �2 9,-- Jj'7 NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are per- mitted to issue the permit. PERMIT NO. 6067-79B,P,E,M PERMIT EXPIRES OWNER Lloyd Hansen CONTR. owner 34-17-45 LOCATION, (A.P. 21 Buehler Ave., oroville VAY Temp. Powe Pole Called fG&E Temp. Elec. Serv. JRV Cal, ed PG&E Temp!/Gas Serv. 11 ailed PG&E, FINALED (Date) (Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING I BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Stemwa l l Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for phsically handica ed Conformance of ex. structure Appliances Gas Piping &Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footinci ELECTRICAL— Masonry Walls Throat Rough Reinf. Steel Final Fixtures ' Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UTILITIES ------------------ Elec- Service Elec. Pedestal Water Piping Sewer Gas Piping MOBILEHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS I (NOTE:. An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DEPARjI MENT OF PUBLIC WORKS 7 County Center Drive — Orovilleifornia 95965 Telephone: 534-4541 APPLICATION AND PERMIT 6061�1_79j authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date Sig ature of ermitee or Agent 9eceipt No. _J`ite-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date ��� 6 7 B Idling permit expires Date BUILDING Owner O SO. FT. OCC. BUILDING VALUATION a Mai I i ng Address � � G l LLC.T , /� .S Telephone No. S 3 �! Contractor z Mailing Address Fireplace Total Valuation Telephone No. Permit Fee QQ Building Address G Y Plan Checking Fee&/or Penalty Permit Fee PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Eyp V L, (, Repair drainage or vent piping 1.50 _ A. P. No. �j 7 C(! 'Zoning & Planning Water piping 1.50 J Z5 Each gas water heater or vent 1.50 F s Sal&<On Fire Dept. FireZone Use Permit Gas piping system 1 - 5 outlets 1.50—a EOA Parking Plans rcel Declaration Parcel Map 60' R/W Improv ments Each additional outlet .30 Building sewer 5.00 Bldg. ons Recd Parcel AEEroval _ Ions Approval Lawn sprinkler system 2.00 NEW ADDITION to UTILITIES ❑ OTHER ❑ Permit Fee $-6, O.$ C ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 , OIO Main service 600V OR LESS 100 AMP OR LESS 5•00 Single Family Duplex ❑ Mobil Home ❑ Others ❑ Main service EA. ADD•L loo AMP 2.50 T� Main service OVER e00V 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW OR ADDNST ( ACC II�hGG CCUP. 1) 22 sq ft CONTRACTORS LICENSE LAW 1 am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW CONSTRESID. (M BRANCH IR T NON-RESID. `BRANCH CIRCUITS) 2.50ea NEW CONSTRPOWER APPARATUS 8 / NON-RESID, (SINGLE OUTLET CIR. Ex. Occup (OUTLETS OR FIXTURES) IB L 1@ 0C FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ ' $7. MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued 1 shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 •4)-0 Heating Cooling J�ZJ .— ",b J ,fib Ventilation Hood 2.00 Permit Fee $ 7. cyc, $ 10C I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ t authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date Sig ature of ermitee or Agent 9eceipt No. _J`ite-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date ��� 6 7 B Idling permit expires Date IONS. 15 �o - 3716 I• r VU S ' t 4.'x•9 �39.J _ / a 6 d i2 °' 1aa26 W ►• // AC / �' .j �► 70 h a ` / 34 PM99_4 a" Ac 6►1050 83 /i O�i� i �p.SSA�h 67 93.7/ I _ROAD NGY ACRES � 1v v � OUIz v ti .77 AC • 45 i J 4 n 9,9 p . 72-1.iv 66 r, 128.94 •112.06 S•� 2 AC • ,�` •o M ® 66 93 73 [32fl 9 • pG. 2.33 AC 399 N 5.1 \ . —.33 1.26• ••�Cr ° it 2.886 AC 1� \� oDp AC "� �j� 5.29 AC ` �� g 16 _ \ ' Av No o 1.74 Ac W \\ 4.455 Ac`` ` N w C3 All ti o I 2.8AC N \ 1.99 AC: 1.83 tp� \ . 1 2. 316 Act- TAPµ o0 23 � Assessor s M p county of Butte, Calif. -96 REV/SED•r 10 s 050 330 v E 'ID ant -i p jopme P�a. D•A ATE USE PERMIT _—VARIANCE ***'/ ADWPERMIT-- MINOR U.P. - � PLANNING COMMISS- PLANNING MANAGER - (J>r � . �:.� � j(/�.'�� 1����J r .;.fir �^,�_ 777- F-7 7 ec- 0utfie tall H ounty Signature Environmenfa!? t. .0, 7 ec- 3 Environmenfa!? t. .0, —;,,Nl) FLOOR -.I 3UEHLER CWLLEI CA 9 XALE = Vt"= I' - K -13 300 0 3030 STAIRSt r , iT' I i. P.-, M \ I / - —0- 0 Ic F Wx W . . . . . . . . . . . . "-A1j I LY R50 M Ix, Yl 10 1 M m ;o� A L L WA I- L'AOI*VM 3 R" 1010 ,,4 is PANT • 13'd' x 15' lir nmen i rit; —s 13 PEDROO M 31 tIi 3C>30 Same" ?�WDE I SELROoM WIAtD6t4/ WtTj+ Sx. 3030 floNImum o?EN DIMENSIOAl OF 211"914H 20'/ WIDEI S.-7 SI. F4- 4AEA F=U IpZI ACE EKI STAY STOVE P 3 t r.o70 . . . . . . . . . . . . "-A1j I LY R50 M Ix, Yl 10 1 M m ;o� A L L WA I- L'AOI*VM 3 R" 1010 ,,4 is PANT • 13'd' x 15' lir nmen i rit; —s 13 Same" Sx. EKI STAY 3 r.o70 DECK --S i 5 V 3.4 /ot PRO F05c- D DEC-KING lot 0.6 -5 4� p90 V I De A 0,Fq VATE Y,4AIO IM 14. vironmental Health County cart r orovilfe, ca c2,1:,five- C) //k- Or,#- q5lp Wo 4069-- Af ... 4? APPR'OVc .Ae4I& C�zvejoprnent Plao D;A%Tp USE PERMIT _VARIANCE ADM.PERMIT // - MINOR U.P. - � /L PLANNING COMMISS- PLANNING MANAGER 3 eel n�" as v -i0.1',6'. ryry TZ;tz' 'Is FWi 1A p- pi Environmenta! 7Co I Nrlol� 1) All s z APPROVED D I ment Plan DATE SEP USE PERMIT —VARIANCE MINOR U.P. v/ ADM.PERMIT_ PLANNING COMMISS. PLANNING MANAGER �ac- 7 --- ---------- "Y Vii« r� AV E= r � , 1 � 1 � 1 ,fD 7C jr1� m p0 c m =+ I � I 7:;7 m` � Or �1 4 0 r � , 1 � 1 � 1 ,fD 7C jr1� m p0 c m =+ I � I 7:;7 BFDR00M, DINING TcHFEN FR EEzfR DRYER w aIV/'`y A 0 0 H JC �a' APPROVED Butte County Environ ental alth Date 0�/ N W SEG TiC-'MAL View , PAGE -y RODE b ARFA 8' 22' ,b&AWN By Lloyd HAMCEN ,S-33 -'! q j 3 PA GE 3 s J43 J � '4 L 1 o%l 144NS&N QJ BuzmLER Ave OR o v1 //t , GA . 9S9G(i Poolve S33 - V913 R cj5: c -d 068'- g lU - /ay - o00 �,lw W A ` �a'x8' S PACO J NOTE. See the attached Li 7D/ bRAwN BY p7 L ial'd NA Ns t 1� 9 -11"'z Iwwpl LIO 47 W-1 BUTTE COUN-'� RUILDING DEPARTMEI-0 p p 0 V F. Y DAAwN BY PtA IG E a LIOYd tiAAIS-6AI BEDPoo "? AiN/NG cz K17CHeIV C� FR EEzfR DRYER w Lr;i,Ty R OOH ftoo R c Jpt51• CLCSET o� I CONC RETE SLA8 4�� X JS Ku 0 o LIN � r i b Q YA _�- SCCTic-'1VAL PA GE y i pfLP-15 ADDS 6 AR,EA S' a2 bRAwiu By Lloyd HAIvrEN S33 -Y4�3 P4 GF 3 s 4� #�� - C OUN 1 1 e R 0 v 7 7-P, u -s.5 A A r 7-,r L O N G E 61 10%V FIX rs Ti. 1 - — S9c7'10N V/Ew FAoM PA G F 3 �i` b DRAWN BY Lloyd HAIV5FN ss3 - IM 3 Z wALI-S Sc�c 3 W ON I .t PlUILDING DEPAR p p 0 V F row RATTERS By LolvGe'FE//ow— C N1 G6• .2 , Jo', ACrEANATZ BRAC Eo 'WAI L .5111 PSG nr KvaA W;rW ss r8 S©L/TH Vic w �• yx �a., = 1 i ! I j ! Ll y 8 I 36, VENT To C AAWL tpAcg S©L/TH Vic w PA G g s- SCnf'S0 ry y y EAC,Y R,4 rrc-: 1 - .mo ; X y W A Ci GRADE_ -Tj N4A FoaT w o r -� r `l COUNI) , f RUjLDj� DEPA P� PAA WN 6y Lloyd HAnrsEK s = 1 PA G g s- SCnf'S0 ry y y EAC,Y R,4 rrc-: 1 - .mo ; X y W A Ci GRADE_ -Tj N4A FoaT w o r -� r `l COUNI) , f RUjLDj� DEPA P� PAA WN 6y Lloyd HAnrsEK a Q a � . y cr a ll N � O v O a rn Z A O Z i1 a o► L ayd NNS&N a! ,BvENLER AvE j - N 0 vi //f , GA � PHONC S33 — sl9/3 r f'.4Rc� 068'- E .. W S PA G E i' w ALL STRUCTURES AND EQUIPMENT INCLUDING OVERHANGS SHALL BE CLEAR OF ALL EASEMENTS. A SET BACK OF .- -7- y M THE SIDE AND �. FROM THE REAR PROPERTY LINES AND FROM THE ROAD CENTERLINE SHALL BE #ffR="Oi STRUCTURES AND EQUIPMENT EXCEPT FOR A 2 FT. EAVE OVERHANG. Go -°{ ub��,dea rs d ass xd`��o � appcokxl o,qed N` reek �f7 � �apet � e J bR,4wN BY L / cm, HA ivs t N _ l ,I r --� r -. -•J —` r -' � _moi �I ��r V � A �U'� l L_1�V ���r� -o _. ._. - -P-. -.5 '=MO -VII 1 11 " nJ `3 '3 nX �1 Ci,,r 1 °1 a�lI s rJiU.� x �v GENERAL NOTES NOTAS GENERALES Trusses are not marked in any way to identify Los trusses no estan marcados de ning6n modo que the frequency or location of temporary bracing. identifique la frecuencia o localizad6n de los arriostres Follow the recommendations for handling, (bracing) temporales. Use las recomendaciones de manejo, installing and temporary bracing of trusses. instalaci6n y arriostre temporal de los trusses. Vea el f2= Refer to BCcr 1-03 Guide to Good Practice for RSI 1-03 Guia de Buena Prr1CtIL oat el Manejo. Instalaci6n Handling In��lling & B�cing of Memel Plateyp'o��de los de Madera Conne��Wood Trusses for more detailed Plarla�s de Metals de Me�loaRip para mayor information. information. Truss Design Drawings may specify locations of Los dibujos de diseno de IDs trusses pueden especificar permanent bracing on individual compression las localizaciones de los arriostres permanentes en los members. Refer to the SCSI I c Summary miembros individuales en compresi6n. Vea la hoja res6men Sheat - Web Member Permanent BraSumm Summary -CSI -B3 -para los amostres nermanentes y refuerzos de los Reinforcement for more information. All other miembros setundarios (webs) para mayor information. EI permanent bracing design is the responsibility resto de arriostres permanentes son la responsabilidad del of the Building Designer. Disenador del Edificio. QThe consequences of improper handling, installing and bracing may be a collapse of the structure, or worse, serious personal injury or death. EI resultado de un manejo, instalaci6n y arriostre inadecuados, puede ser la caida de la estructura o a6n peor, muertos o heridos. Banding and truss plates have sharp edges. Wear 0r gloves when handling and safety glasses when F® cutting banding. Empaques y placas de metal tienen bordes m afilados. Use guantes y lentes protectores cuando corte los empaques. HANDLING - MANE]O QAllow no more No permita mas Q Use special care in than 3" of defiec- de 3 pulgadas de windy weather or tion for every 10' pandeo por sada 10 near power lines of span. pies de tramo. and airports. to• ,y lo• A 6' . -I— +IK• _ T��- 10, I o QPick up vertical Levante de la cuerda bundles at the superior los grupos top chord. verticales de trusses. ONE WEEK OR LESS- MORE THAN ONE WEEK QBundles stored on the ground for one week or more should be raised by blocking at 8' to 10' on center. Los paquetes almacenados en la tiers por una semana o mas deben ser elevados con bloques a cada 8 o 10 pies. QFor long term storage, cover bundles to pre- vent moisture gain but allow for ventilation. Para almacen-amiento por mayor tiempo, cubra los paquetes para prevenir aumento de humedad pero permits ventilaci6n. Utilice cuidado especial en dias ventosos o cerca de cables electricos o de aeropuertos. HAND ERECTION — LEVANTAMIENTOAMANO i BRACING FOR THREE PLANES OF ROOF Qsses 30' or erssses 20' supportr `� Q les , supportat `t1 . EL ARRIOSTRE EN TRES PLANOS DE TECHO at peak. quarter points. f Levante Levante de I I7f This bracing method is for all trusses except 3x2 and 4x2 parallel chord trusses. del pito los los cuartos U Este mftodo de arriostre es para todo trusses excepto trusses de cuerdas paralelas 3x2 y 4x2. trusses de 20 de tramo los pies o menos. trusses de 301) TOP CHORD —CUERDA SUPERIOR es o menos. Trusses up to 20' �I pi� ha Trusses to 30' Trusses hasta 20' Trusses hasta 30' I HOISTING — LEVANTAMIENTO QHold each truss in position with the erection equipment until temporary bracing Is installed and truss is fastened to the bearing points. Sostenga cada truss en poslci6n con la grua hasta que el arriostre temporal este instalado y el 1 truss asegurado en los soportes. 1 I Do not lift trusses over 30' by the peak. No levante del pico los trusses de mos de 30 pies. Greater than 30' Mas de 30 Pies HOISTING RECOMMENDATIONS BY TRUSS SPAN RECOMMENDACIONES DE LEVANTAMIENTO POR LONGITUD DEL TRUSS Toe•inil Spreader bar for {. truss bundles N,,,, Tagline " O O QCheck banding Revise los empaques prior to moving antes de mover los bundles. paquetes de trusses. Q Avoid lateral bending. — Evite la fiexi6n lateral. Do not store No almacene unbraced bundles verticalmente los upright. trusses sueltos. Do not store on No almacene en uneven ground. tierra desigual. a .7 Tagline r T� oe-in Spreader bar 1/2 to 2/3 truss length TRUSSES UP TO 60' TRUSSES HASTA 60' Truss Span Top Chord Temporary Lateral Brace (TCTLB) Spacing Longitud de Tramo Espaciamiento del Arriostre Temporal de la Cuerda Superior Up to 30' 10' o.c. max. Hasta 30 pies 10 pies maximo 30' to 45' 8' o.c. max. 30 a 45 pies 8 pies maximo 45' to 60' 6' o.c. max. 45 a 60 pies 6 pies maximo 60' to 80'* 4' o.c. max. 60 a 80 pies* 4 pies maximo *Consult a Professional Engineer for trusses longer than 60'. *Consulte a un ingeniero para trusses de mas de 60 pies. IN n( See BC51-82 for TCTLB options. 'y u Vea el SCSI -B2 para las opciones de TCTLB. 60' or less ®Refer to IiS�L@Sz Summary Sheet - t Gable End Frame I Braclna. )-7f Repeat diagonal braces. F Approx. 1/2 _� I Vea el restimk LI truss length SCSI -B6 - ArrfRepi[a los arriostres del truss termdiagonales. TRUSSES UP TO 30' de un techo a TRUSSES HASTA 30' aquas• n( Set first five trusses with spacer pieces, then add diagonals. Repeat Ll process on groups of four trusses until all trusses are set. Instale los cinco primeros trusses con espaciadores, luego los arriostres diagonales. Repita este procedimiento en grupos de cuatro trusses hasta que todos los trusses esten instalados. 2) BOTTOM CHORD — CUERDA INFERIOR Locate Spreader bar Attach 1m above or stiffback x. max. mid -height - Temporary and 15 15' o.c. for 4x2 chords Diagonal braces Spreader bar 2/3 to 10' of every 15 truss �— 3/4 truss length Tagline spaces (30' max.) Trusses for more 1° 16.7' f— TRUSSES UP TO AND OVER 60' 1/4" 1' 1-1/8° 188' TRUSSES HASTA Y SOBRE 60' BRACING - ARRIOSTRE QRefer to BCSI-B2 Summary Sheet - Trus Installa- v [ion and Temporary Bracing for more information. Vea el res6men BCSI-B2 - Instalaci6n de Trusses Q v y Arriostre Temporal para mayor informaci6n. Do not walk on unbraced trusses. No Gamine en trusses sueltos. Locate ground braces for first truss directly in line with all rows of top chord temporary lateral bracing. Coloque IDs arriostres de tierra para el primer truss directamente en linea con cada una de las filas de arriostres laterales temporales de la cuerda superior. Brace first truss well �— before erection of additional trusses. Top Chord Temporary Lateral Bracing (TCTLB) nin. Lateral braces 2x4x12' length lapped over two trusses. , 10'-15' max. Diagonal braces every 10 truss spaces (20' max.) Some chord and web members not shown for clarity. 3) WEB MEMBER PLANE — PLANO DE LOS MIEMBROS SECUNDARIOS Web members Diagonal braces every 10 truss spaces (20' max.) 10'-15' max. same spacing as bottom chord Some chord and web members not shown for clarity. lateral bracing 46 DIAGONAL BRACING IS VERY IMPORTANT iEL ARRIOSTRE DIAGONAL ES MUY IMPORTANTE! BRACING FOR 3x2 AND 4x2 PARALLEL CHORD TRUSSES EL ARRIOSTRE PARA TRUSSES DE CUERDAS PARALELAS 3x2 Y 4x2 Q Refer to BCSI-B7 Maximum lateral brace spacing Summary Sheet Bow Max. Truss Bow Length 10' o.c. for 3x2 chords - Temporary and 15 15' o.c. for 4x2 chords Diagonal braces Permanent Bracing 10' of every 15 truss for Parallel Chord QTolerances spaces (30' max.) Trusses for more 1° 16.7' information. 1/4" 1' 1-1/8° 188' Vea el res6men BCSI-87 - Arriostre Tolerancias para I 1/2" 2'-. 1-1/4" 20.8' temporal y permanente de The end diagonal trusses de cuerdas brace for cantilevered o I Plumb paralelas para mayor trusses must be placed Lateral braces informad6n. on vertical webs in line 2x4x12' length lapped 1-1/2" 25.0' with the support. over two trusses. INSTALLING - INSTALACION QTolerances for Out -of -Plane. — Tolerancias para Fuera-de-Plano. Do not exceed maximum stack heights. Refer to BCSI-B4 Summary Sheet -Construction Loadino for more information. No exceda las maximas alturas recomendadas. Vea el res6men BCSI-B4 Cargo de Construcci6n para mayor informaci6n. Do not overload small groups or single trusses. No sobrecargue pequefios grupos o trusses individuales. Material Height (h) Mex. Bow Length m Bow Max. Truss Bow Length 76" -- --- ------- ��ti �— -------.-------- Length 3/4° 12.5' ► 8" Max. Bow Length —►l� 3-4 tiles high 7/8° 14.6' QTolerances for 0/50 D (ft.) 1° 16.7' Out -of -Plumb. 1/4" 1' 1-1/8° 188' Tolerancias para I 1/2" 2'-. 1-1/4" 20.8' Fuera-de-Plomada. n1.3/8 22 9' o I Plumb 3/4" 3' ibob 1„ 4' 1-1/2" 25.0' 1-1/4" 5' 1-3/4° 29.2' D/5o max 1-1/2" 6' 2° 1-3/4° 7' 2" >_ 8' CONSTRUCTION LOADING — CARGA DE CONSTRUCCION 0 Do not proceed with construction until all bracing is securely Maximum Stack Height and properly in place. for Materials on Trusses No proceda con la construcci6n hasta que todos los arriostres esten colocados en forma apropiada y Segura. Do not exceed maximum stack heights. Refer to BCSI-B4 Summary Sheet -Construction Loadino for more information. No exceda las maximas alturas recomendadas. Vea el res6men BCSI-B4 Cargo de Construcci6n para mayor informaci6n. Do not overload small groups or single trusses. No sobrecargue pequefios grupos o trusses individuales. Material Height (h) Gypsum Board 12" Plywood or OSB 76" Asphalt Shingles 2 bund Concrete Block 8" Clay Tile 3-4 tiles high QPlace loads over as many trusses as possible. Coloque las cargas sobre tantos trusses como sea posible. QPosition loads over load bearing walls. Coloque las cargas sobre las paredes soportantes. ALTERATIONS — ALTERACIONES QRefer to BCSI-BS Summary - Truss Damage. lobsite Modifications and In<tallation Error. Vea el res6men BCSI-B5 Danos d trusses. Modifi a ion < n la Obra v rror d Instals ion Do not cut, alter, or drill any structural member of a truss unless specifically permitted by the Truss Design Drawing. No corte, altere o perfore ning6n miembro estructural de los trusses, a menos que este especificamente permitido en el dibujo del diseno del truss. tr QTrusses that have been overloaded during construction or altered without the Truss Manufacturer's prior approval may render the Trus Manufacturer's limited warranty null and void. Trusses que se han sobrecargado durante la construcci6n o han sido alterados sin una autorizaci6n previa del Fabricante de Trusses, pueden reducir o eliminar la garanda del Fabricante de Trusses. NOTE: The Truss Manufacturer and Truss Designer must rely on the fact that the Contractor and crane operator (if applicable) are ca- pable to undertake the work they have agreed to do on a particular project. The Contractor should seek any required assistance regarding construction praNces from a competent party. The methods and procedures outlined are Intended to ensure that the overall constructian techniques employed will put Boor and roof trusses Into place SAFELY. These recommendations for handling, installing and bradng wood trusses are based upon the collective experience of leading technical personnel In the wood truss Industry, but must, due to the nature of responsibilities implied, be presented only as a GUIDE for use by a qualified Building Designer or Erection/Installation Contractor It is not Intended that these recommendations be Interpreted as superior to any design specification (provided by either an Architect, Engineer, the Building Designer, the ErecdoNinstallation Contractor or otherwise) for handling, installing and bracing wood trusses and It does not Pmdude the use of other equivalent methods for bracing and providing stability for the walls and columns as may be determined by the truss Erection/Installation Contractor. Thus, the wood Truss Council of America and the Truss Plate Institute expressly disclaim any responsibility for damages arising from the use, application, or reliance on the recommendations and Information contained herein. C,IL WOOD TRUSS COUNCIL OF AMERICA TRUSS PLATE INSTITUTE One WTCA Center • 6300 Enterprise Lane • Madison, WI 53719 583 D'Onofrio Drive • Madison, WI 53719 608/274-4849 • www.woodtrussxom 608/833-5900 • www.tpinst.org BIWARNllxl7 031125 L�A�' " �� `,�-J;.1::a� 'J ` u�� . '017�uG�'.�5 J.:vl Imo' o r3'L.V�J:Y �1 I i 3�7: Ca]�r�-�:� C1 I?_�1rL