HomeMy WebLinkAboutRES-ACC-26-0027 Plan Corrections Rev2 Department of Development Services Paula Daneluk, Director
Curtis Johnson, Assistant Director
7 County Center Drive T: 530.552.3700
Oroville, California 95965 F: 530.538.7785
buttecounty.net/dds
This cover sheet provides a summary of the concurrent review of the permit application by all
applicable County departments and divisions. Each department has independently reviewed the
submitted documents for code compliance and project feasibility. The review status for each
department is indicated in the checklist below, and any corrections or conditions identified by
reviewers are attached for reference.
Date: 6/3/2026
Applicant Information: Niels Jacksen
thejackesens@alo.com
Assessor Parcel Number: 027-040-069 Address: 46 Pond View Lane, Palermo, CA
Building Permit Number: RES-ACC-26-0027 Plan Check Cycle: Review #2
Description: BARN (1040) W/ ELEC AND PLUMBING
*See attached correction letters for the contact information for each department.
Department / Division Status
Building Division Pending Corrections with comments
Planning Division Approved
Fire Department Approved with Comments
Public Works – Permits Approved
Environmental Health Approved
Department of Development Services Paula Daneluk, Director
Curtis Johnson, Assistant Director
7 County Center Drive T: 530.552.3699
Oroville, California 95965
buttecounty.net/dds
June 3, 2026
Niels Jacksen
thejacksens@aol.com
Assessor Parcel Number: 027-040-069
Building Permit Number: RES-ACC-26-0027 Plan Check #2
Description: BARN (1040) W/ ELEC AND PLUMBING
Occupancy Classification: U
Construction Type: VB
Stories: 1
Fire Sprinklers: No
Building Total Area: 1,040 Sq Ft
WUI Zone: SRA
Fire Severity Zone: HFS
Thank you for submitting your building permit application. We have reviewed your documents and listed the required
corrections below. Please provide a written response addressing each comment. Clear and complete answers will help us
approve your project faster. When you are ready, please submit a complete digital set of revised plans to
DSBuilding@buttecounty.net. You can upload larger files directly to www.bcdds.net/drop.
GENERAL COMMENTS by: Plans Examiner
1. Please respond in writing to each comment by marking this comment list or creating a response letter. Indicate which
detail, specification, or calculation shows the requested information. At minimum, the following must be included with
each plan review response:
1. Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s).
2. Briefly explain in writing, how the design is intended to comply with the applicable code sections.
3. Revisions must be identified with a cloud and delta symbol.
2. The plan check fee covers three review cycles. Reviews beyond the third cycle, deferred submittals, and changes to
approved plans will be billed on a time-and-materials basis.
STRUCTURAL COMMENTS: by: Michael Main, P.E., Plan Check Engineer
1. The building as presented does not meet the requirements of the conventional braced walls for the lateral system. Please
either demonstrate full compliance with CRC R602.10 for conventional braced wall or provide an engineered design by a
California licensed design professional (engineer or architect).
(PC2) – Braced Wall Panel Layout found on sheet 10 of 11. This layout shows 4’ panels at all the corners as well as
at spacings not exceeding 20’ between panels which is acceptable. However, the building length is 40’ and maximum
spacing between braced wall lines is 35’ per CRC Table R602.10.1.3. This building length will either need to be
reduced by 5’ or an internal braced wall line will be required to reduce the distance between braced wall lines.
7. The plans show a post constructed of four 2x4 studs supporting the ridge beam at both gable end-walls. Please address
the following:
a. COMPLETED
b. Even if one assumes that the column is balloon framed (continuous from foundation to ridge beam) the
column shown on the plans is inadequate. Please revise.
(PC2) – The plans show three 2x6 balloon framed to the post. This still appears inadequate. Please
increase the post to four 2x6 nailed together or a single 6x6 post.
The Department of Development Services is currently open to the public from 8:00 am to 4:00 pm. If you wish to discuss
these plan check comments, please call during our business hours or contact us by e-mail at the address below. Permit status
can be tracked by logging on to http://www.buttecounty.net/dds and clicking Building Permits Status.
Michael Main, P.E.
Plan Check Engineer
530.552.3655
mmain@buttecounty.net