HomeMy WebLinkAboutCOM-ELC-26-0061 Plan Corrections Rev1 Department of Development Services Paula Daneluk, Director Curtis Johnson, Assistant Director 7 County Center Drive T: 530.552.3700 Oroville, California 95965 F: 530.538.7785 buttecounty.ca.gov/dds This cover sheet provides a summary of the concurrent review of the permit application by all applicable County departments and divisions. Each department has independently reviewed the submitted documents for code compliance and project feasibility. The review status for each department is indicated in the checklist below, and any corrections or conditions identified by reviewers are attached for reference. Date: 11/6/2026 Applicant Information: Epic Wireless Group josh.jordan@epicwireless.net Assessor Parcel Number: 029-060-020 Address: 4409 Aguas Frias Rd., Richvale, CA 95965 Building Permit Number: COM-ELC-26-0061 Plan Check Cycle: Review #1 Description: INSTALL (N) 30kw Diesel Generator w/ 200G Fuel Tank *See attached correction letters for the contact information for each department. Department / Division Status Building Division Pending Corrections with comments Planning Division Approved Fire Department Pending Corrections with comments Public Works - Land Development Approved Public Works – Permits Approved Environmental Health Approved with Comments SPECIALIST WAITING FOR THE CUSTOMER TO SEND QUESTIONNAIRE TO AQMD. ONCE THIS HAS BEEN COMPLETED, SPECIALIST WILL CLOSE THIS REVIEW. Department of Development Services Paula Daneluk, Director Curtis Johnson, Assistant Director 7 County Center Drive T: 530.552.3699 Oroville, California 95965 buttecounty.net/dds November 5, 202 Epic Wireless Group 605 Coolidge Drive Folsom, CA Assessor Parcel Number: 029-060-020 Building Permit Number: COM-ELC-26-0061 Plan Check #1 Description: INSTALL (N) 30kw Diesel Generator w/ 200G Fuel Tank Flood Zone: A per 06007C0950E F.I.R.M. dated January 6, 2011 Sacramento River Designated Floodway – E Thank you for submitting your building permit application. We have reviewed your documents and listed the required corrections below. Please provide a written response addressing each comment. Clear and complete answers will help us approve your project faster. When you are ready, please submit a complete digital set of revised plans to DSBuilding@buttecounty.net. You can upload larger files directly to www.bcdds.net/drop. GENERAL COMMENTS: 1. Please respond in writing to each comment by marking this comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the following must be included with each plan review response: 1. Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s). 2. Briefly explain in writing, how the design is intended to comply with the applicable code sections. 3. Revisions must be identified with a cloud and delta symbol. Complete and clear responses will expedite the re-check of this project. 2. The plan check fee covers three review cycles. Reviews beyond the third cycle, deferred submittals, and changes to approved plans will be billed on a time-and-materials basis. NON-STRUCTURAL COMMENTS: 3. Please correct the panel schedule totals and coordinate the engine block-heater load with the manufacturer’s specifications. Update the generator load calculation using the coordinated loads. CEC 702.4(A)(2). 4. Coordinate the equipment grounding conductor size with the No. 8 auxiliary circuit conductors. Provide proportional sizing or substantiate compliance with the exception to CEC 250.122(B). STRUCTURAL COMMENTS: 1. The flood elevation certificate lists the lowest height of machinery and equipment as 84.8’ with the lowest adjacent grade listed as 82.0’. The plans show the generator installed directly on the existing concrete slab. Please demonstrate how the new generator will be raised 2.8’ above the existing ground / slab surface in compliance with the FEMA Flood Elevation Certificate. 2. Calculations assume a concrete slab thickness of 8”. Please note this thickness requirement on the plans. FLOOD ZONE COMMENTS: 1. Please place the following information on the plans: a. Flood Hazard Zone: A b. Base Flood Elevation: 82.5’ c. Lowest Elevation of Machinery and Equipment: 84.8’ d. Lowest Adjacent Grade: 82.0’ 2. The Central Valley Flood Protection Board locates the new generator at 39.4644778, -121.859105. The FEMA Flood Elevation Certificate locates the new generator at 39.458931, -121.859105. Please coordinate. 3. Please indicate in a prominent location on the plans that a finished construction flood elevation certificate is required prior to final approval of the structure. (Butte County Code Chapter 26, Ordinance # 4041) The Department of Development Services is currently open to the public from 8:00 am to 4:00 pm. If you wish to discuss these plan check comments, please call during our business hours or contact us by e-mail at the address below. Jordan Debrunner Michael Main, P.E. Plans Examiner Plan Check Engineer 530.552.3647 530.552.3655 jdebrunner@buttecounty.net mmain@buttecounty.net Butte County Fire Department Office of the Fire Marshal 176 Nelson Avenue Oroville, CA 95965 Office (530) 538-7888 www.buttecounty.net/fire COMMERCIAL PLAN REVIEW LETTER October 27, 2026 Harris Landowning Corp. 4409 Aguas Frias Rd. Richvale, CA 95965 APN: 029-060-020 Building Permit Number: COM-ELC-26-0061 Description: INSTALL (N) 30kw Diesel Generator w/200G Fuel Tank Occupancy Classification: U Dear Applicant, The plans you recently submitted have been reviewed by the Fire Department referencing the 2025 edition of the California Building and Fire Codes (CBC and CFC). The numbered comments listed below in the body of this letter must be addressed in writing prior to Fire Department Approval of your project. 1. Sheet A-1.1, Site Plan, Add a note and illustrate on Sheet A-1.1 the use of a Knox Padlock or Knox Box for fire department access into the compound. Product information and ordering available on www.knoxbox.com or contact the Butte County Fire Marshal Office at 530-538-6320 for more information. The Fire Marshal's Office is open 8:00 a.m.–5:00 p.m. if you have any questions pertaining to this permit. Please call during business hours or email the address below. Permit status may be tracked at the Accela Citizen Access portal: Butte County Accela ACA. Troy Hand Marnie Gedney Deputy Fire Marshal Fire Protection Planning 530.538.6320 530.538.6320 troy.hand@fire.ca.gov marnie.gedney@fire.ca.gov